Insulation Testing Fluke-1507 - Fluke Fridays - Episode 106 

Fridays With Brandon
Подписаться 3,9 тыс.
Просмотров 58 тыс.
50% 1

All Fluke Insulation Testers - www.amazon.com/shop/fridayswi...
Fluke-1507 - amzn.to/43G8wJX
www.fluke.com/en-us/product/e...
Fluke-1503 - amzn.to/3xesFeb
www.fluke.com/en-us/product/e...
Fluke-1587 FC - amzn.to/4cEzlCg
www.fluke.com/en-us/product/e...

Опубликовано:

 

26 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 22   
@enriquealvarez2045
@enriquealvarez2045 17 дней назад
Thank you sir
@gazyoung8490
@gazyoung8490 3 месяца назад
very good, thank you
@randyboden6087
@randyboden6087 11 месяцев назад
Thanks for the 1507 tour! I just started using one. Suggest just taking one reading to ground though. The winding continuity was proven in the first test. If there is a ground, it will be on all of them.
@tracyzhang7999
@tracyzhang7999 11 месяцев назад
Very useful, and clear! Thank you
@jimmybarnes2753
@jimmybarnes2753 9 месяцев назад
Dont touch them gator clips while that red light is on it will make tears run down your legs !
@markm0000
@markm0000 9 месяцев назад
He did at 7:15? Did you break yours doing that?
@jasonfoster9118
@jasonfoster9118 8 месяцев назад
It'll shock the pee out of you lol
@davidebiagi9941
@davidebiagi9941 7 месяцев назад
Thanks a lot, I thought mine was fried😂😂😂😂😂😂😂😂
@ChrisHVAC
@ChrisHVAC 10 месяцев назад
How about a video with the 1507 testing hvac compressor in the real world?
@josephstanio4219
@josephstanio4219 Год назад
Thanks for the Great video. Curious what would be an unacceptable ohm reading on the 500 volt meg test. Is it a motor specific value? Or is anything under 550 meg ohms not acceptable. Thanks
@fridayswithbrandon
@fridayswithbrandon Год назад
It is manufacture specific. But the main rule of thumb is you want them all to be very close. If one is different you probably have a problem
@chrissanchez6675
@chrissanchez6675 9 месяцев назад
From my factory training, FANUC motor spec is anything above 100Mohms is good. Anything below and you could start to cause damage servo amplifiers
@luckydiaz5479
@luckydiaz5479 6 месяцев назад
Ser, question for voltage test. How to change from Vdc setting to.Vac? Is it automatically change over while testing on AC voltage?
@fridayswithbrandon
@fridayswithbrandon 6 месяцев назад
The insulation testers only output DC voltage. You can test an AC system but it will be with DC Voltage out of the meter. If you wanted to put AC voltage to test a system you would need whay they call a high pot tester. Fluke does not make this type of tool.
@TheEspinoza-hf1xf
@TheEspinoza-hf1xf 6 дней назад
What happens if a 3ph compressor fails the insulation test???
@fridayswithbrandon
@fridayswithbrandon 6 дней назад
@@TheEspinoza-hf1xf it could indicate it will stop working very soon or it's already no longer able to run. As far as how to repair it would need to be replaced or sent to motor shop for re-winding.
@mikeadler434
@mikeadler434 10 месяцев назад
👍👍
@ResuelveFilms
@ResuelveFilms 4 месяца назад
I have a question. If I’m trying to megger a 480v 3phase motor, should I use 500v or 1000v for the insulation test?
@fridayswithbrandon
@fridayswithbrandon 4 месяца назад
I've heard in the industry most will do twice the operating voltage. Thus 1000v
@H.A..
@H.A.. 9 месяцев назад
5.5 Mega Ohms??!!! are you sure that wasn't 550 Mega?
@fridayswithbrandon
@fridayswithbrandon 9 месяцев назад
Not sure
@H.A..
@H.A.. 9 месяцев назад
@@fridayswithbrandon Yeah bro, I think it was 550 Mega, but I could be wrong. Thanks for the post, it's great.
Далее
How to use a multimeter like a pro, the ultimate guide
12:55
Fluke Insulation Tester In Action, (AKA Megger)
4:19
POWER CABLE TESTING - WITH FLUKE INSULATION TESTER
8:05
Using the FLUKE 1507 to Identify a bad motor.
3:18
Просмотров 106 тыс.
Using a Megger
17:34
Просмотров 81 тыс.