Тёмный

Inverter Refrigerator Compressor Direct Start & UVW Testing | Embraco Fridge Board 

Forever Tech English
Подписаться 79 тыс.
Просмотров 215 тыс.
50% 1

Опубликовано:

 

29 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 81   
@rolanddejesus8685
@rolanddejesus8685 Год назад
thanks a lot sir for sharing...God bless.
@forevertechenglish
@forevertechenglish Год назад
God Bless you
@uru-freemind7711
@uru-freemind7711 3 месяца назад
Los motores trifásicos se pueden operar como monofásicos con capacitores... Se podría operar el motor inverter con capacitores sin placa?
@vadimtyutyunnik353
@vadimtyutyunnik353 Год назад
You said at 3:40 - it works on 220VDC 40-160Hz. Why we call it DC when it has some frequency??
@TheNYgolfer
@TheNYgolfer Год назад
He misspoke. He meant 220VAC.
@ateseteknik621
@ateseteknik621 29 дней назад
Merhaba videolarımız Çok bilgilendirici ancak size bir şey sormak istiyorum kırmızı kablonun yanındaki siyah kabloya anakarttan kaç volt geliyor acaba ya da o siyah kablo ile anakart arasındaki iletişim hakkında da bir video çekerseniz çok memnun olurum Saygılarımla
@strimearts6998
@strimearts6998 7 месяцев назад
Hello, great video. I have a gn162430x - 5645512900 Inverter PCB. Is there a way to start it manually? My compressor seems to be fine, just there is no volatage output at the UVW pins. thank you
@mhandrabat331
@mhandrabat331 Год назад
سلآم عليكم ورحمة الله وبركاته استادي الكريم هل ممكن تشغيل الضاغط انفرتر بدون كارت الكنترول
@sofroniocarranza6064
@sofroniocarranza6064 Год назад
Thank you for all you done I seen your mother board trouble shooting is a near place where to buy New mother board of Samsung inverter how much cost most client rush to fix.
@forevertechenglish
@forevertechenglish Год назад
This A Good question But I Usually repair them, Buying a new one you could ask the samsung's service center for the motherboard
@nick-firstest
@nick-firstest 11 месяцев назад
Is regular gas generator(without inverter) can run refrigerator without any harm?
@forevertechenglish
@forevertechenglish 11 месяцев назад
Yes it do run the refrigerator without any harm, But it is not Bill or electricity friendly.
@jgc12154631
@jgc12154631 27 дней назад
This inverter board can't change the frequency? Just on & off?
@HeartyLindo
@HeartyLindo 11 месяцев назад
How about the single wire from speed switch it is the same?also connect in neutral the red wire from speed switch?
@godalmighty-lm2yt
@godalmighty-lm2yt Год назад
Please I like the way you explain things, am a Technician in refrigeration and air conditioning and also washing machine aspects but sir I have little problem with HITACHI twin refrigerator, The compressor will start and goes off immediately please may I know the courses of this problem . Emmanuel.
@forevertechenglish
@forevertechenglish Год назад
Well dear I could not say anything this way, But if this refrigerator has a PCB board, it could be faulty, Check for a lose wiring connections, check the compressor, the relay. If everythings ok, If it has a PCB, Then the PCB board could be bad. Let me know then.
@SNBBank
@SNBBank 25 дней назад
I have one question same way to check dc fcu fan moter also
@robeltsegaye1505
@robeltsegaye1505 Год назад
Thanks 4 the uvw tester im using it its effective if u can i would like u to explain winding of washing machine motor and how to know the truns of the burned coil and the other thing is this week i bought fixit ic programmer please make some videos how to install the fixit programmer software on pc and where to find the programs
@WildHilary
@WildHilary 13 дней назад
Davis Margaret Rodriguez Frank Lee Sandra
@wasimedoo7994
@wasimedoo7994 Год назад
Good information friend but I don't get any part to replace on that board but I saw a video on tube some guys run the invertor compressor with acopositor 4uf and 220 vote can it work thanks God bless 👍
@troubleshooter1975
@troubleshooter1975 9 месяцев назад
Yes, testing a 3-phase motor on single phase power 'can' be done, in certain circumstances (with a capacitor sized properly for the motor being tested). BUT, the power will be badly unbalanced, and power factor and currents will be way off from safe design ratings. (another words, the current through the windings will not match, will likely be excessive, and the timing of the current flow will be out of sync - it will be 'out-of-step' with the rotation!). [also, if you phase it wrong, the motor WILL run backwards... It may run fine, but not oil itself!] This almost always will create excess heating of the motor, quickly overloading it. You could possibly burn it out in minutes! Test it this way only long enough to determine that it is rotating and producing flow and pressure (like a few seconds to half a minute). -To confirm that the motor can run... Then find the other reason the motor is not getting proper power. Mr K L
@LibbyMarshal-r1h
@LibbyMarshal-r1h Месяц назад
Thomas Sandra Lee Sandra Lopez Betty
@lasanthabandara7455
@lasanthabandara7455 2 года назад
How to check the timer side to see if the timer is working properly
@forevertechenglish
@forevertechenglish 2 года назад
Dear in the video we do not talk about any timer we talking about thermostat if you want to know about thermostat let me know
@mikefreedom5612
@mikefreedom5612 Год назад
Thank you How can I get that boarx?
@gerryyulo
@gerryyulo 7 месяцев назад
The voltage on the 220v compressor reads only 150v coming from the inverter of Electrolux freezer-fridge, what do you think seems to be the problem, can it be on the inverter module or on the main module? I'm a DYI'er
@conradogoodwin8077
@conradogoodwin8077 Год назад
Incredibly clear explanations, thanks!
@forevertechenglish
@forevertechenglish Год назад
You're very welcome!
@wasimedoo7994
@wasimedoo7994 Год назад
Is there any way else to start and run the invertor compressor with out the board if the board damage
@broncheemims8493
@broncheemims8493 2 года назад
Sir I like the way you explain things electrically. I have a degree in electronics,so it helps troubleshoot the board more accurate.
@forevertechenglish
@forevertechenglish 2 года назад
Best of luck
@nols3726
@nols3726 11 месяцев назад
I Exactly.
@anassyria5176
@anassyria5176 6 месяцев назад
Hello sir from Syria Is it safe to run a refrigerator with inverter-driven compressor with a square wave AC?
@Adam90155
@Adam90155 Год назад
Super film 😁gdzie moge kupic taka płytke sterującą?
@Waldemar_Pachol_official
@Waldemar_Pachol_official Год назад
Fejk! Film ukradziony z indyjskiego kanału. Płytka też fejkowa - brak modułu SD30Mxxxx.
@Adam90155
@Adam90155 Год назад
​@@Waldemar_Pachol_officialwitam może Pan wie gdzie mogę kupić płytke sterująca sprężarkę inwertorową na krótko? Pozdrawiam
@charlesnokae6987
@charlesnokae6987 Год назад
Your explanation is very helpful 💯👍🏾. Please would you please kindly help me out with a Cubigel Compressor - NUT125FSC is not working and it's PCB green led light blinking and my colleagues were assuming that the compressor is faulty due to voltage changes during startup and compressor not cut in.
@forevertechenglish
@forevertechenglish Год назад
Send me its Pictures with diagram on my social media
@AnUnapologeticApologist
@AnUnapologeticApologist Год назад
If you have the inverter connected normally, except for the female connectors that connect to the compressor windings, once the unit is plugged in what voltage should you expect to see from the female connector on any lead to another? My condenser fan will power on but the compressor will not. Resistance is good on every winding, no short to ground. Power from the female connector that goes to compressor reads 14VAC applied. I believe the inverter is the issue
@forevertechenglish
@forevertechenglish Год назад
Which Inverter Refrigerator Is it??
@nols3726
@nols3726 11 месяцев назад
I have a inverter fridge 30 cubic 5 yrs ago it just stop cool. My technician said I need a compressor and Control Board. I am in Carribbean I buy it at pc Richard USA. I am learning you explain it so good I understand very well.
@forevertechenglish
@forevertechenglish 11 месяцев назад
That's great
@EveSherman-x1j
@EveSherman-x1j День назад
Dulce Forges
@thomasoconnor-cs3ee
@thomasoconnor-cs3ee 3 месяца назад
So when you join the 2 points of the optocoupler the thermostat doesnt need to be connected?
@martingates6501
@martingates6501 Год назад
One question, I'm testing an LG inverter compressor like you did in this video and the compressor start and everything's ok, but the discharge is too weak, it's because doesn't has refrigerant or the compressor is not good?
@jaybala7493
@jaybala7493 2 года назад
Sir thank you very much
@tambejohn7382
@tambejohn7382 Год назад
Thanks alot for the lessons
@SilvioTomazdeAquinoTomaz-sc2mi
@SilvioTomazdeAquinoTomaz-sc2mi 7 месяцев назад
Know a lot, congratulations!
@debdymilanez9418
@debdymilanez9418 Год назад
Parabéns pelas explicações 👏👏👏👏🇧🇷🇧🇷🇧🇷🇧🇷🇧🇷🇧🇷
@JaysonPagador-gd5mm
@JaysonPagador-gd5mm 7 месяцев назад
How can I find the compressor wuv no sign in compressor sir
@nhiduong1040
@nhiduong1040 6 дней назад
Thanks
@sonu.labrez
@sonu.labrez 2 года назад
sir ye video hindi me dalo na
@forevertechenglish
@forevertechenglish 2 года назад
It is available in hindi
@zawrialangosman6804
@zawrialangosman6804 2 года назад
Best video
@kumudiniwasanthi1952
@kumudiniwasanthi1952 Год назад
Super
@hugocornejo5757
@hugocornejo5757 9 месяцев назад
Cómo saber de qué lado puentear el optoaclopador?
@ugochukwu-uf6iv
@ugochukwu-uf6iv Год назад
Thanks very rich in content sir
@forevertechenglish
@forevertechenglish Год назад
So nice of you
@josecarlosmejia9632
@josecarlosmejia9632 7 месяцев назад
GREAT INFORMATION FOR IMPLEMENT ON SCHOOL OF TECHNICIANS ABOUT INVERTES THANK YOU
@tesfahungetahunargachew4328
Tnx sir for your presentation have a good new year
@forevertechenglish
@forevertechenglish Год назад
Same to you
@francoisguyot9770
@francoisguyot9770 10 месяцев назад
Just the info I needed.! Thx
@hadjnabil4811
@hadjnabil4811 Год назад
than you lot's😘
@troubleshooter1975
@troubleshooter1975 9 месяцев назад
Very good video. I learned a lot! Only mentioning some minor technical, or translation errors so that no one gets confused: @3:30 Just to clarify, the inverter board generates "3-phase" AC power, in the vicinity of 230VAC [not DC]. @TheNYgolfer also posted this already - thank you. I'm not sure what he is showing in the drawing of a board output waveform, but there are many excellent diagrams of 3-phase power on the internet. As he drew that, it would represent a single phase (of the three). [It also slopes 'backwards in time' at one place, but it is hand drawn. I just didn't understand what aspect he is illustrating.] @4:45 To clarify, he is using 240VAC, not DC, to power the board. Brown is more properly referred to as 'hot' or 'live', and not 'positive', which is misleading and can be confused with DC where the term 'positive' actually means 'positive' DC polarity. [I also came across someone calling the live as 'phase', and the other as neutral.] He has 240VAC showing on his meter, but refers to it as 220V; doesn't matter -they rate them for 220V-240V input anyway. [What country are you in fine sir?] I only mention it because I have had some people get confused by voltage ratings... 1:40 3:09 3:57 Mr K L
@forevertechenglish
@forevertechenglish 9 месяцев назад
Well Thanks! Man For this Comment!! It will Surely Help Others.
@forevertechenglish
@forevertechenglish 9 месяцев назад
I will clarify you in another video.
@16valve64
@16valve64 2 года назад
Thanks a lot for sharing your thoughts
@forevertechenglish
@forevertechenglish 2 года назад
My pleasure 🥰
@ferozenoordeen3711
@ferozenoordeen3711 Год назад
Thanks for the training... Please explain the input DC voltage to the compressor in your next lesson . Regards...
@katchutarao4313
@katchutarao4313 9 месяцев назад
This video very use full thank you sar
@softsilver2346
@softsilver2346 2 года назад
Good
@forevertechenglish
@forevertechenglish 2 года назад
Thanks
@muhammadatifsafdar
@muhammadatifsafdar 4 месяца назад
Much informative!!
@abdohajj5135
@abdohajj5135 10 месяцев назад
Nice thx to you❤❤❤
@harunrashid8796
@harunrashid8796 9 месяцев назад
Thanks a lot.
@venkateswarludantha6702
@venkateswarludantha6702 Год назад
Hi sir very nice video. Iam venkatesh 🇮🇳india
@forevertechenglish
@forevertechenglish Год назад
Thanks and welcome
@seshachary5580
@seshachary5580 6 месяцев назад
very educative. Thank you
@forevertechenglish
@forevertechenglish 6 месяцев назад
You're welcome
@LMR5826
@LMR5826 11 месяцев назад
Quality Distributor #2 Westminster Road.kingston. all inverter Parts are there.
Далее
FATAL CHASE 😳 😳
00:19
Просмотров 1,4 млн
Inside Out 2: BABY JOY VS SHIN SONIC 4
00:16
Просмотров 4,6 млн
Bearwolf - GODZILLA Пародия Beatrise
00:33
Просмотров 193 тыс.
How to Convert OLD Normal Refrigerator To Inverter
25:11
FATAL CHASE 😳 😳
00:19
Просмотров 1,4 млн