Тёмный
No video :(

IS Code 456:2000 Specifications for Deflection Control of beam /Deflection control of beam 

Valley to Ridge
Подписаться 2,9 тыс.
Просмотров 19 тыс.
50% 1

Aaj k is video me hum dekhenge ki deflection kya hota h,according to IS Code 456:2000 kisi bhe beam me maximum deflection kitna ho sakta h, Beam k deflection ko contol karne k liye kya kiya jaa sakta h, Deflection of beam ya beam ka deflection span to effective depth ratio par kaise depend karta h,Kisi bhi beam k liye span to effective depth ratio kitna hona chahiye, simply supported beam ke liye span to effective depth ratio kitna hona chahiye,Cantilever beam ke liye span to effective depth ratio kitna hona chahiye,Continious beam ke liye span to effective depth ratio kitna hona chahiye, Reinforcement pr deflection kaise depend karta he, tension reinforcement ke liye modification factor kitna hota he, Compression reinforcement ke liye modification factor kitna hota he,Modification factor kya hota h,
In todays lecture we will study that what is deflection,What should we do to controle the deflection of a beam ,What is the limit of maximum deflection of a beam,What is the limit of maximum deflection of a Simply supported beam,What is the limit of maximum deflection of a Cantiler beam,What is the limit of maximum deflection of a continious beam,what is span to effective depth ratio,what is modification factor

Опубликовано:

 

24 сен 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 30   
@user-pp8wl4kq9p
@user-pp8wl4kq9p Месяц назад
Best 🎉
@himanshunotiyal9269
@himanshunotiyal9269 9 месяцев назад
Bahut khub
@ssconsultants1750
@ssconsultants1750 2 года назад
good information, make more videos
@keshavkishorsahay1515
@keshavkishorsahay1515 2 года назад
Very well explained 🙏 Thank you 😊
@kennedy-zs1go
@kennedy-zs1go 2 года назад
Outstanding contribution just carry on
@engineerirfancheema9328
@engineerirfancheema9328 2 года назад
Great video sir carry on
@aamir6976
@aamir6976 2 года назад
Tq
@msrinivasakannan
@msrinivasakannan 2 года назад
Nicely explained sir
@sudiptachaudhury9820
@sudiptachaudhury9820 2 года назад
well explained..
@axatrathod
@axatrathod 8 месяцев назад
👌🏼👌🏼👌🏼
@somnathkarmakar1801
@somnathkarmakar1801 2 года назад
@8.53 check span / d value. Upto 10m
@valleytoridge9821
@valleytoridge9821 2 года назад
It was a mistake in summery, kindly ignore it I have explained earlier in this video. Thanks for you valuable response.
@somnathkarmakar1801
@somnathkarmakar1801 2 года назад
@@valleytoridge9821 wlcm Sir
@Demonslayer-lt4qf
@Demonslayer-lt4qf Год назад
Span is effective or clear span?
@PintuLal-wf7mj
@PintuLal-wf7mj 2 месяца назад
Sir last me values wrong kr diye ho cantilever or simply supported beam ki..app change kr diye ho ak dusare ki values...pls correct it
@valleytoridge9821
@valleytoridge9821 2 месяца назад
Yes dear , sorry for that . last me Jo summary batai usme mujhse mistake ho gyi. Uploaded video me correction mushkil h ,,please consider dear.
@Arsiddique.RPM.doctor
@Arsiddique.RPM.doctor 2 года назад
Sir contiliver beam span 10m length hai to L D fix column me Kitna Hoga कंटिलिवर बीम में स्पान 4 मीटर आगे तक है तो उसका एंकर लेंथ LD development , पिछे कालम में कितना जाएगा formula explain करे और मुझे बताइए सर इंटरव्यू में पुछा था Please reply me sir
@valleytoridge9821
@valleytoridge9821 2 года назад
Aapka question thik se samjh nhi aaya,please question clear kare mujhe, aap development lenth k liye puch rhe h ya L/D ratio k liye.
@vishvasmeshram6094
@vishvasmeshram6094 2 года назад
69d or 1.5 times lenth whichever is greater
@rahulmaurya9003
@rahulmaurya9003 2 года назад
Baki ka videos banao sir plz🙏
@valleytoridge9821
@valleytoridge9821 Год назад
Definitely
@sj55gh
@sj55gh Год назад
When will we take l/350
@ashishvishvakarma1132
@ashishvishvakarma1132 2 года назад
More imp video for CE
@diplomajunction176
@diplomajunction176 2 года назад
Kindly check at 8:47
@foundationtopeak7451
@foundationtopeak7451 2 года назад
What should i check?
@diplomajunction176
@diplomajunction176 2 года назад
@@foundationtopeak7451 sir you have interchanged the l/d ratio for cantilever and simply supported
@valleytoridge9821
@valleytoridge9821 2 года назад
Sorry for the mistake and thank you to realiz my mistake.actually at the end it was a summery kindly ignore it.
@Ravikundalwal
@Ravikundalwal Год назад
Span overall h ya effective?????
@arun-kumar78
@arun-kumar78 11 месяцев назад
Effective depth bro
@valleytoridge9821
@valleytoridge9821 9 месяцев назад
Effective Span will be safer side
Далее
Beam Short and Long Term Deflection in ETABS
12:44
Просмотров 11 тыс.
Insane Coffee trick EXPOSED 😱☕️ #shorts
00:20
Fancy VS Classic #shorts  @CRAZYGREAPA
00:33
Просмотров 1,3 млн
The actual reason for using stirrups explained
9:01
Просмотров 777 тыс.
Open Beams Have a Serious Weakness
11:02
Просмотров 863 тыс.
Insane Coffee trick EXPOSED 😱☕️ #shorts
00:20