Тёмный

Jandy JXI Pool Heater - Brand New Not Running Check Ignition Steps & Flame Sensing Failure 

Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Подписаться 158 тыс.
Просмотров 4,5 тыс.
50% 1

Frequent mistake preventing pool heater operation resulting in Check Ignition Steps
Let's Make The Trades Great Again! Join Mikey Pipes Philanthropy, Inc., an IRS 501(c)(3) non-profit public charitable organization. Our mission is to offer free or low-cost plumbing, heating and cooling services to those in our community who can't afford to hire a professional. Help us here: www.paypal.com/donate/?hosted...
Need a website for your contracting business? Check out Footbridge Media for their amazing special on not only a website but SEO services for only $249/month! www.footbridgemedia.com/?ref=...
Need a CRM or dispatching and invoicing app? Check out HouseCallPro: tinyurl.com/MikeyPipesHCP
What’s in your Veto? Here is mine:
Veto TP-XXL amzn.to/3zX10vg
Testo Combustion Analyzer: amzn.to/3Zd7naH
Digital Manometer: amzn.to/3EDt5ey
Milwaukee M18 Blower: amzn.to/46iTo6j
Milwaukee M12 Fuel 1/4" Impact Driver amzn.to/3I9yLfI
Milwaukee PVC cutter: amzn.to/3sbrdUc
Mini Waterproof Storage bin: amzn.to/3yfgsEv
Wiha Allen Keys: amzn.to/33ipGmb
HIKMICRO B20 amzn.to/33iGklx
Furnace Switch amzn.to/31X89PT
Milwaukee Light amzn.to/3I38Lmh
Wagos amzn.to/34QoiaU
Milwaukee Set amzn.to/33vnQOz
Torpedo Level amzn.to/3no1oOk
Crescent set amzn.to/3GtZeV8
Wiha 7 piece set amzn.to/3rkISaK
Milwaukee step bit amzn.to/3I395Bv
Thermocouple Flare wrench: amzn.to/3noJZ8s
Ridgid 10” wrench amzn.to/3GvRnqa
Fluke non-contact tester amzn.to/31VQgAQ
Klein drivers amzn.to/3qoe21W
Knipex Wrenches amzn.to/3trzFjS
Klein 11-1 amzn.to/3tpsPLD
12” crescent amzn.to/3A0CZ6S
Gerber Gear Pocket Knife amzn.to/3foaW7I
Yellow Jacket Hand Ratchet amzn.to/3nrDgup
I am on Discord & WhatsApp!
Discord: / discord
WhatsApp Group: chat.whatsapp.com/CHZWtZe4KMG...
New oval raised silver stickers are from:
Armored Decal Company Inc.
35 Victoria St. E, Unit 9
Alliston, Ontario L9R 1T3
(p) 705-435-6665
(e) ken@armoreddecal.com
(Tell them Mikey Pipes sent you)
Please support this channel and Mikey Pipes and consider the following…
Pipe Doctor FlexFit Embroidered Caps
Minimum donation of $37 is appreciated
(If you are international - please add a minimum of $40 for shipping/postage)
Shopping on Amazon? Please use my referral link amzn.to/2PjjS4v
Sticker Requests:
Do you want a sticker to show your support of this channel? Email your request to me! mike@mikeypipes.com
Name
Address
City, State, Zip
Consider making a donation of $5.00, or ANY amount, to the postage fund! I literally mail out stickers all over the globe. I've sent stickers to HVAC guys in Afghanistan, New Zealand & all over Europe.
PayPal is: office@pipedoc.net
Venmo: @PipeDoctor
CashApp: $mikeypipesny
Zelle: mike@mikeypipes.com
Want to send a love letter, note or gift? Our mailing address is:
Mikey Pipes, Inc.
1010 Central Avenue
Woodmere, NY 11598
#hvac #mikeypipes #pipedoctor
Music from #InAudio: inaudio.org/
Other music from MOVAVI STUDIO SUITE 2024 under license by 3:10 Global Holding, Inc.

Хобби

Опубликовано:

 

28 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 57   
@scottvolage1752
@scottvolage1752 Месяц назад
Make the trades great again Mikey Pipes. Smash that Like Button Folks. Smash it for Peter. That first coupling is a shipping coupling. Hacks.
@MokenaBob
@MokenaBob Месяц назад
Mike, You are the man.
@jonwillis9075
@jonwillis9075 Месяц назад
The REAL moral of the story is if you are NOT calling Mikey Pipes, you are getting screwed!!
@PipeDoctor
@PipeDoctor Месяц назад
Yet the haters say the opposite. Go figure.
@jasongeo2
@jasongeo2 Месяц назад
I'm stumped. The heater was already wired and power was present? Changing the voltage should not had required reconfiguring source power wires. 😳
@kat2641
@kat2641 Месяц назад
😱🤦‍♂️🤦‍♂️🤦‍♂️ seriously? What the F were they thinking?? Running a mechanical unit non-grounded talk about liability plus 🤦‍♂️🤦‍♂️ but serious great troubleshooting skills right there❤
@YouzY666
@YouzY666 Месяц назад
Wouldn't have known that it sucks in the gas so the lower number is okay. Learnt something!
@jasongeo2
@jasongeo2 Месяц назад
Mike but the heater was running prior correct? Or did someone come before you and switched voltage settings and walked away?
@neilcvids2583
@neilcvids2583 Месяц назад
no comments yet
@Samlol23_drrich
@Samlol23_drrich Месяц назад
How about now?
@nickc6399
@nickc6399 Месяц назад
That’s not even a coupling on the gas line. That’s a thread protector.
@jasongeo2
@jasongeo2 Месяц назад
I mean they didn't have the right size pipes so they kept extending them. Obviously sloppy work no details. The electrical conduit poorly connected or say not even secure to the chasis leaving exposed wires. Thats why Mike likes to as he says observe the surroundings and how it all looks before taking next steps. It was easy to see Amateurs rigged it up
@Trainman0401
@Trainman0401 Месяц назад
Did you have to contact tech support to resolve the electrical connection issue?
@PipeDoctor
@PipeDoctor Месяц назад
No, I knew the issue. I've seen this many many times before.
@jasongeo2
@jasongeo2 Месяц назад
I was checking the service manual and there is nothing pertaining to the L1 and neutral wires needing to be reversed when selecting 120 volts on the voltage selector board. Idk...not sure what you found?
@Poolmedic
@Poolmedic Месяц назад
That is a thing with Jandy. If you switch the hot and neutral the heater will not work properly.
@jasongeo2
@jasongeo2 Месяц назад
@@Poolmedic I'm going take this as the line and neutral were improperly connected from the get go?
@Samlol23_drrich
@Samlol23_drrich Месяц назад
I guess when it was 240 it’s 2 hot leads with no neutral. When someone switched it to 120 one of the legs is hot and the other is neutral and to fire the igniter it’s polarity specific, so if it’s done backwards it won’t fire.
@jasongeo2
@jasongeo2 Месяц назад
@@Samlol23_drrich So if Mike would had switched the voltage selector back to 220 would it had fired up?
@Samlol23_drrich
@Samlol23_drrich Месяц назад
@@jasongeo2 I don’t think so cause there was only 120 coming in. Same 3 wires as 240. 240 is HHG 120 is HNG. Guess there were the 2 lugs where the wires go whether 120 or 240. But if 120 one of the wires is N and it’s gotta be on the right lug.
@swaterman08
@swaterman08 Месяц назад
If you had to rewire it, why not terminate the liquid tight correctly and correct the ground wire? since you were the last to touch it, could they blame you for leaving it that way, if someone got hurt, or I guess as long as you tell the customer then you are in the clear? it looks like they could have removed that black grommet to fit the liquid-tight connector if they did not want to drill it out.
@baratono
@baratono Месяц назад
That gas line looks like it's made up with a "thread protector" rather than a proper coupling. They have straight threads and aways leak.
@harryschrysan3183
@harryschrysan3183 Месяц назад
You are right looks like one of those they put to protect the threads. It's all the way threaded. Whatever works right?! 😅 🤣
@StevenGage
@StevenGage Месяц назад
Re Bonding - Why is their a concern of electricity traveling from the heater to the pool, if the connections from the heater are all PVC. There is no metal.
@GoogleMe-en9sg
@GoogleMe-en9sg Месяц назад
Water is a conductor of electricity.
@StevenGage
@StevenGage Месяц назад
@@GoogleMe-en9sg Thats the concern? That a pump or heater will have some type of short, and electricity will flow thru the water in the pvc pipe to the pool?
@GoogleMe-en9sg
@GoogleMe-en9sg Месяц назад
What about the PRV and ground? GFI protection? Who paid for the repairs?
@PipeDoctor
@PipeDoctor Месяц назад
Homeowner
@Samlol23_drrich
@Samlol23_drrich Месяц назад
Is this the same guy as the indoor heater?
@kens.3729
@kens.3729 Месяц назад
LMAO 😬👍
@steveg5576
@steveg5576 Месяц назад
That's funny !
@Jasheon
@Jasheon Месяц назад
Why didn’t the home owner just contact Jandy directly? It’s under warranty, it’s a brand new heater. They could have gotten it taken care of free of charge
@JesseDoesHVAC
@JesseDoesHVAC Месяц назад
Jandy would have come out, voided the warranty and charged a call out anyway. Thats why id bet Pipe Doctor got called out to bring it up to code and get it running…
@Jasheon
@Jasheon Месяц назад
@@JesseDoesHVAC gotcha
@robertjoseph1592
@robertjoseph1592 Месяц назад
Word of advice: require the pool contractor to subcontract out the heater installation to a qualified and licensed company like Pipe Doctor.
@jasongeo2
@jasongeo2 Месяц назад
Mike where do i park my car if I come into work ? Parking seems tight there and there's a Woodmere parking ticket maid running around.
@jasongeo2
@jasongeo2 Месяц назад
No punt to you Mike. But all anyone needs to rig up a pool heater is basic plumbing and electrical skills and common sense. Plus knows how to read instructions. That's all you need
@STXVIEC
@STXVIEC Месяц назад
The sound the heater made when firing the last time did not sound healthy. JXIs fail on a regular basis. We went through 2 of them. First time was through warrenty and second time I switched brands. Even if the install is correct the heat exchanger will still fail within a year regardless of water chemistry...
@ThumperKJFK
@ThumperKJFK Месяц назад
👍✌
@ianwally818
@ianwally818 Месяц назад
Teflon tape on gas pipe , great.
@PipeDoctor
@PipeDoctor Месяц назад
Yeah. No shi*
@TheRAMBO9191
@TheRAMBO9191 Месяц назад
🥃👍🏻
@aaronkoster3940
@aaronkoster3940 Месяц назад
NYC fuel gas code. 403.9.3. Tape is allowed. But not at pressure regulator. Would certainly not consider it good practice.
@PipeDoctor
@PipeDoctor Месяц назад
Wrong 😑
@aaronkoster3940
@aaronkoster3940 Месяц назад
@@PipeDoctor was pretty shocked myself when I saw that, but it is in the New York City code. Apparently new to 2022
@aaronkoster3940
@aaronkoster3940 Месяц назад
Look it up. It's there
@everettstevenson2111
@everettstevenson2111 Месяц назад
Hey Mikey, of Mikey Pipes Plumbing not easy being cheesy. There should be a number six copper bonding wire going from gas fired equipment to the main electric panel. And the equipment should be a GFI circuit. Again, a Class one, Hazaardous two location? "people, water and electric do not mix well. 42 volt can kill. But again, you are just a dumb plumber. Love you buddy, you be safe out there.
@PipeDoctor
@PipeDoctor Месяц назад
Love you. No homo gene
@williamloder9194
@williamloder9194 Месяц назад
What a screwed up install. Hope the owner has some recourse and needs to find another pool company. Installer needs to learn how to install it correctly
@throttlebottle5906
@throttlebottle5906 Месяц назад
morale of the story, don't let fools work on pools? 🤣
@kens.3729
@kens.3729 Месяц назад
How is a Pool Company allowed to Install a Natural Gas Pool Heater ? Pool Company College Intern Program Special ? 🤪👎
@Poolmedic
@Poolmedic Месяц назад
If an actual pool professional installed it, it would have been done properly and to code. Obviously this was not a professional company. As a pool professional we install pumps, filters, heaters, chemical control systems, automation and other equipment per manufacturer recommendations and to code. Telling my industry to stay in my lane and clean pools is offensive.
@kens.3729
@kens.3729 Месяц назад
If your Company is Qualified and Competent, you have every Right to Install the Items you Listed in your Comments. The Issue is there are a Lot more Unqualified Companies. 👎
Далее
МЕГА ФОКУС С ЧИПСАМИ
00:42
Просмотров 108 тыс.
Угадай МОБА 1 🥵 | WICSUR #shorts
01:00
Просмотров 1,7 млн
How to Dynamically Test a Capacitor: Tips and Tricks
24:22
I Built a Wood Fired Pool Heater!       (Raging Hot)
43:45
Просмотров 491 тыс.
CAA Conversion kit at ZAHAL 🎯
0:14
Просмотров 73 млн