sir JF pag 10kwp po ba ung Solar Panel setup, kailangan 10kw din ung capacity inverter na bibilihin kahit mas mababa sa 10kw ung peak consumption? Di ko kasi sigurado kung sa solar panel capacity or sa demand ba magbabase ng inverter selection
New subs sir,a Question lang sir May 50w na 18.1v / 2.76a + 30w na 18v / 1.66a = 51.34 watts from 80watts (67% loss) Tama sir? Question sir what can I do para maging 80w output nya sir? Need ba isang controller pa?
@@reginalduy3678 Pakipanood nyo po ito. Kalkulasyon po yan ng kung paano mag size up ng solar power system. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-qBS8jrly9Rw.html
@@JFLegaspi sir bat ganun pwm ko nag blink nmn ung charging pero pag uwi ko galing work di man lang tumaas battery ko. Brand new battery ko sir. Naka 30w at 50w po ako parallel gaya ng turo nyo sir. Nakatapat sa araw nasa taas ng bubung Btw salamat po new subs nyo po ako.
in your last example of series-parallel configuration, you can get an efficiency of around 87% if you parallel the two 200W panels in series with your 400W panel.
salamat po sir malaking tulong po ito, actually di ko alam ang watt loss ng magkaibang size ng SP, sana po magtutor din kayo ng size ng wires na gagamitin salamat po ulit God Bless!!! EDITED: meron na palang wire gauges sizes, kakasub ko lang kasi hehe
ang solution sa magkaiba na size ng PV ay gumamit ng blocking diod ito ay pwede lang kung ang PV mo ay magkalapit ng voltahe (VMP) 50w to 200w d masyado mag babawas sa Imp tataas ang harvest so pwede natin pagsamahin ang 160w at 100w pv sa iisang SCC ng d masyado mababawasan ang A sa V sya mag babawas ng around 0.7v per panel so kung nasa 18v magiging 17.3v x ung pinagsamang Imp (A) pag 300+ na ung PV D na pwede kasi malayo na masyado ung voltahe mas ok na mag add nalang new SCC at dun ilagay ung mataas
JF Legaspi Sir...! You are really a brilliant man in this planet, thank you so much for sharing your knowledge I really love and appreciate much. Mabuhay po kayo! GOD BLESS and Long Live...
Napaka galing Ng pagkakagawa Ng video sir jf. May pinanood na Ako before ganitong discussion pero mas madali ito ma gets at madali Rin balikan kapag nalilito Ako.
Thank you Po Sir JF.... MaLaking tulong Po Ang tutorial nyo at madali unawain..lagi ko Po inaabangan mga vlog nyo .. God Bless you Po and more power...
Thank You Sir/Prof. sa mga very informative at very very reliable tutorial videos mo. Malapit kona matapos solar off-Grid set up ko. Maraming Salamat uli!
Maraming salamat sir sa video nyo now we know how to compute different solar panel wattage, hindi kasi maiiwasan kung mag upgrade ka tapos hirap humanap ng ganong solar panel na kagaya ng dati at kung wala ka na mabili ng ganoon.Sir meron lang ako napuna tungkol sa 200 watts specs niya na Imp 5.36A ang nailalagay nyo po 6.56A pero konti lang po ang difference nila.
Good day. Wala pong anuman. Tungkol sa 200W solar panel specs na napuna ninyo. Hindi lahat ng 100W, 200W, 300W, 400, 500W ay magkakapareho ang specs. Iba ibang manufacturer, iba iba din po yan.
Sir good day po,slmat sir sa mga idea moh,marami na akng nkabitan ng mga solar system sir dahil sa mga tuturial moh sir jf,thnk u.alwys watchng sir frm cebu province.
Good day Sir JF. Helpful and informative ang video nyo as always. Ask ko lang po if also possible to connect in parallel ang two toroidal off-grid inverters with the same model (not hybrid)? Maraming salamat for providing as education in a well organized and comprehensible manner. Mabuhay po kayo.
Good day. Kung sa DC side/supply ng dalawang toroidal inverters, pwede. Depende na lang sa C-rate ng battery kung kakayanin ang hugot ng dalawang inverters. Pero kung sa AC side/output, hindi pupwede. Puputok kapag ginawa nyong parallel ang dalawang inverters.
Thank you sir . Malaki tulong ito sa mga bagohan. Para mas safe same specs nlng talaga gamitin or gumamit nlng nang isa pang SCC if gusto mag dagdag nang panel with lower specs. Tama po ba sir?
Panel 1, which is capable of producing 200 W at its maximum power point (MPP), is only producing approximately 165 W because it is forced to operate at the lower current. This results in a loss of potential power generation. The reason for the power discrepancy is due to the series connection limiting the current to the lowest panel's current rating (Panel 2 at 5.41 A). This forces Panel 1 to operate below its MPP, reducing its power output from 200 W to approximately 165 W. The excess power from Panel 1 is not "produced" because the panel is operating at a lower current than its optimal current. This is a common issue in series-connected PV arrays where mismatched panels (in terms of current rating) lead to suboptimal performance. The power output is inherently limited by the panel with the lowest current capacity, leading to the observed total power of 265 W instead of the combined rated power of 300 W.
Sir love this content po dagdag kaalaman sakin to, tanong lang po since magkakaibang Panels po ang gamit Pano po kung separate SCC sila tas isang battery lang(Off-Grid). thank you sir
Gud am,magttnong po kung myron kyong mai-recommend n complete guidebook abt solar power system installation from designing (computation or formulas) & up to the completion of installation).Tnx.
against ako sa pmax computation, kung different Ampere ang panel oks lang yun as long as parallel at yung lowest volts ng panel ay pasok sa charging requirements ng battery. e.g lowest voltage ng panel is 18v pero 12v lang naman ang battery, papatong parin yan unless 24v na ang battery na gagamitin. sa series connection hindi talaga recommended pag different Ampere since dun sa mababang Ampere na panel mag kaka bottleneck dahil hindi dadaloy ang mataas na Ampere sa lowest Amp na panel, solution iparallel ang dalawa or tatlong lowest Ampere na panel para mag match sa biggest panel na nais i parallel. make sure na in good running condition ang panel kung mag parallel, pag hindi cgurado pwede gumamit ng high Ampere diode sa positive or negative side ng each panel para forward lang ang direction ng supply at hindi babalik ang supply sa may issue na panel. expect a 0.5Voltage drop pag may diode but you are safe to go mag parallel kahit iba ibang specs wag lang mas mababa sa charging requirements ng battery.
Sir gud day, pra walang agam agam ang gawin n lang ay puruparehas lahat ang specs, lalot diyers ka lang . Di ba poh . Inuulit ko mga video mo at natuto nman ako slamat god bles...👍
Tanong ko po sir JF kung tama ako. Mayroon akong pv 2x 100w Vmp 17.6 at imp 5.71na naka parralel connection at sineries ko sa isang 200w na may Vmp 19.69 at imp 10.21. Ang reading sa scc elejoy 600w. PV volt:48V at CHG current is 16a. Kapag imultiply ay maging 768 out of 400w.
Hi sir. Pwd po makabili ng scc mppt nyo ung low prof lang po at lowprice😀😀😀 NB lang po s solar diy maraming slamat po sir jf legaspi.. more vlog pa po.. pra maraming matutunan...
good morning sir JF pasensya na po sa abala, sa busy ninyong time, Sir clarification lang sa PV calculation, series parallel connection of 8 pcs na 400w with Voc 41.2 at Isc 12.28A at ang Inverter ay may max na Voc na 150v at Mppt SCC na max 80A, kung ang connection ng 2 series at 2 parallel 123.6v at Isc naman ay 24.56A sa anim na PV paano ung natirang dalawa na 800w, isasama ko rin ba siya sa naunang 2S/2P para maging 3S/3P, wala bang overload or exceeding sa Voc ng Inverter na 150v, salamat sa mga reply ninyo po at god bless.
May tutorial ako paano mag match ng solar panels, scc at hybrid inverter. Eto ang link. Paano Mag-Match ng Solar Panel PV Array at SCC or Hybrid Inverter - Pro Level Tutorial ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Rqjk18L31lg.html
Good Am Sir JF, inquiry about latest Trina solar panel same wattage but different specs. New Model Trina Solar VMP-33.3v IMP-15.03A 500w output Old Model Trina Solar Vertex VMP-42.8v IMP-11.69A 500w output Solis 3.6kw inverter Ang sabi kasi sa store sa angeles di daw pueding i mix sa old model kase mababa ang VOC tas tumaas ang ISC and IMP. Puedi ba itong i connect and mix kasi i did the math pero pareho lang ang output nya kung dadagdag pa kami ng 2 solar panel, 1500w ang first 3 previous commection kung dagdag pa kami ng 2 na solar para 2500w output power sa inverter. Correct me if i made it wrong ang computation. (3) vmp 33.3v = 166.5 voltage series (2) vmp 42.8v = 83.6voltage series 11.69A X 195 V = 2,279.55 wattage output Or puedi bang gawan nalang ng separate string papunta ng inverter sa PV 2 input? Magakakaroon ba ng problem regarding sa set up. Ano po ba ang pueding gawin na solution or connection sa aming set up.salamat po in advance, please help and advise. God bless po!
sir kapag po nag parallel. yung IMP po mag po no ? dipende parin po ba sa inverter kung pasok sa total IMP po ng dalawang panel sa maximum na kaya ng inverter ?
Good morning po Sir JF itatanong q lang po pwedi bang iparallel 590w sa naka series na 280wx2 parallel q ung 590w ano ang magiging epecto sa naka series 2x 280w
Sir, wat if 3pcs 550w panel. Tas ang koneksyon po is nka series ung dalawa tas pinarallel po sa isa? Pwd rin po ba yan ung same lang po sir na hnd po magkakaiba ang watts po?
Sir JF is it posible po ba na if meron akong inverter na operating dc voltage 45-90v. is it posible po ba na gagana sya sa 50v voc series with 30 voc na panel? in short , magkaibang VOC ang each panel in series?
sir jf may tanong lang po ako meron po kasi akong 8 solar panel na tig 200 watts bale nakabit na po ito sa aking hybrid inverter ang bale ginawa ko po ay series connection ok naman po gumana po naman siya ng maayos at nagagamit na po namin kaya lang po nag dagdag po ako ng 2 piraso na tig 550 watts pano ko po gagawin ang connection kadi hindi na po balanse ang watts at voltage ng bago at yong luma salamat po sir
Sir, may 4 panels po ako na 200 watt each.. same specs lahat. Plan ko mag 2s2p connection pro 24v system po set up ko, pwede ba po ung 2s2p sa 24v system set up? Help namn po, baguhan lang po sir eh..