Good day my young Padawans! These types of video tutorials take so much time, and effort to make. Not to mention the amount involve to buy all these items you see in the video. You can support my channel by clicking on the “Super Thanks” button ❤ on the top, or by simply sharing my videos on your social media account.
Jusko nasagot nA UN tamang katanungan Ko SA Dame Ng MGA napanood Ko Sir mas nA intindihan Ko taiaga UN content MO... Tama Ka Sir mas maganda taiaga advantage Ng ATS... SALAMAT Sir idol
Thank you Sir!! Sa totoo lang wala po akong alam sa mga ATS at LVD. ung DIY system ko wala nyan. Pero ung explanation nyo ay clear. I'll make sure to include those when i upgrade my system soon. Thank you very much!!!
Maraming salamat Sir sa magbigay kaalaman larangan ng solar power tutorial ang dami kung natutonan sa lahat na vedio at palagi ako nanunuod at ma upgrade na yung ginagawa ko na solar power bank. God bless sir JF salamat.
maraming salamat sir sa walang sawang magbigay kaalaman sa larangan ng solar power tutorial ang daming kung natutunan yan po ang isusunod ko sa aking maliit na setup post ko po sa LPP pag matapos na more power God Bless po
Instead of the SSR, they use a simple installation relay, changeover relay 12-240V DC | DIN rail 10044271 and a TXATS-100/2P. The latter can be controlled with the installation relay.
Very informative Sir JF. Question po, sa may existing na breaker recommended nyo ba na ilabas yung main then papasok sa ATS then pabalik sa breaker ng bahay. Of course, another silly question. Does this need to have a proper electrician to do this process? Or kung alam naman po namin gagawin ay ok na na i-DIY.
Thank you po sa another video na maraming kapupulutan ng aral, Sir JF. Tanong lang po, meron po bang disconnect module na dalawa ang function, bale nagcu-cut off if 20%SOC and 90%SOC na yung batteries? Thank you po.
Question lang po Sir, kung off grid setup po iintegrate to, Saan po banda ipaparallel yung optional monitoring and safety components like SPD's and wattmeter, sa Inverter AC Output AC MCB po ba? bago mag ATS? Yung Over and Under Voltage and Current Protection device, edi parang redundant na po yung undercurrent and undervoltage features since may LVD na po and Solid State Relay, kaya parang di na po kailangan iinstall eto if mag opt out using ATS? Pagkakaintindi ko rin po Sir, mas preferable na gamitin tong ATS setup sa high load high kwh solar pv system tama po ba?
I have a quesion to ask. My set up would be a 24 volts load then im planning to use ATS in case our eletricity goes down. In Normal Power i will use 24volts converter to complement the 24volts load while my Reserved Power would be 24volts battery for the 24 volts load. Will this ATS operate in this set up. Normal Power(220VAC),Reserved Power(24VDC), Load (24VDC)
Diba sir, sa AC output ng inverter naglagay kayo ng LVD at SSR para ma cut ang AC output line, so continues padin aandar ang inverter sir? So kelangan mag dagdag ako ulit ng LVD separately together with DC relay papuntang Inverter para ma power off ang Inverter encase of Low Voltage? Ito sana gusto ko malaman sir.
Thank you sir for this sir. Ang Tanong ko lang po necessary pa kaya lagyan ng lvd at ssr yung mga toroidal off grid inverter like one solar at zamdon kahit may built in na sila? Salamat sir.
Maraming salamat sa tutorial sir. Tanong lanh po, ung inverter is directly connected siya sa battery no? D bale ang purpose ng relay is to disconnect ung line galing sa output ng inverter to load kapag nag trigger na ung low voltage?
Good day. Bilang kompletong kasagutan sa inyong tanong, pakipanood ang aking tutorial tungkol dyan. Eto ang link. Paano Mag-Match ng Solar Panel PV Array at SCC or Hybrid Inverter - Pro Level Tutorial ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Rqjk18L31lg.html
Sir jf maayung adlaw jan,and have nice day.sir my konting tanong lang ako sir.tUngkol sah SSR sir okey lng bah gamitin ang SSR at LVD module sah snat inverter nah 48v nah 3kw sir?.applicable paba ang SSR at LVD module elagay sah snat 3kw sir jf? Ang baba kasi ng low volatge cut off ng snat sir,hindi nah safe sah gel type sir jf.hintay ako sa replay moh sir.solid viewers po ako saiyo sir,from cebu province.
@@JFLegaspi good day sir jf,yung cut off voltge ng snat 3kw invrtr sir ay nasa 11.5v sir jf.pag naabot dya ng 11.5v jan nah sya mag o,off sir. Pro kung gamitin koh ang ganyang built in ats sir,ay hindi sya aabot sah 11.5v sir,magcut off sya sah 12.ov nah settings koh sir.
Sir jef. Dc to dc po gamit q ng ssr po . Pag on q n po c inverter at may supply n po sys s aplainces low voltage po sya agad pero pag nkarekta sya s battery mataas po rating output ng inverter anung prob q po dun sir jef slamst po
Bakit pho tumotonog Ang Ats kung na disconnect nah Ang low voltage disconnect sah inverter q KC s 110v 110 v so kung madisconnect Ang isah may 110 pah natira yng Ang nag papatunog sah Ats?
hello po new subs here, tanong ko lang po pwede kaya pagpalitin ung wiring ng N at R ng ATS kung ang normal source mo ay ung from meralco at reserve lang ang galing sa battery bank? idea po ay kusang gagana ang inverter/battery bank kapag brownouts. salamat!
Good day. Ang sagot sa inyong tanong ay pwede. Eto po ang kompletong tutorial tungkol sa inyong tanong. Paano Mag-Install Automatic Transfer Switch Mula Solar Off-Grid To Distribution Utility ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-FvuGrnAPJDg.html
maraming salamat sir JF....pwede ba yung SSR ko ay dc-dc tapos ang papatayin ko ay yung inverter input para kasama si inverter mag off pag lowbatt? may chance ba na masisira si inverter pag ganun na bigla off na lang sya?
Walang anuman. Pwedeng SSR DD ang gamitin, sa DC side ang cut-off. Mataas ang switching current, mas maganda. Lagyan din ng heat sink kasi umiinit yan, at meron ding voltage drop ang DC to DC SSR. 😊👍
Good Day Sir, i just want to ask regarding with LVD MODULE XH M609. Do you have any idea if is it possible to connect it with any device for communication purpose or monitoring purposes. Meron kasi open port sa side nya mga apat ata yan. Plano ko kasi e monitor ang LVD module remotely if possible.
Sir ano po kaya solusyon para d kukurap ung mga ilaw or mamatay ang tv during transfer ng ats? Kailngan po bang lagyan lhat ng ups? Slamat po and more power..
Hi Sir Sana mapansin po ninyo, Ibinase ko po yung offgrid ko sa lectures ninyo. Yung MCB ko po 10A from power inverter to load, Kakabitan ko po ito ng ATS Yun po bang MCB 10a ay papalitan ko ng 63A o i-parallel ko lang? Salamat Po
Good day. Yan po ay magandang tanong dahil karamihan po kasi sa mga seller online ay over rated ang mga binibentang SSR. Ibig sabihin, ang mga rated 100A ay hinda talaga 100A. Pero kung genuine na 100A ang rating, i mmultiply nyo lang sa voltage at ang resulta ay ang power rating in watts.
May ATS na po na may built-in a battery voltage sensor. Smart cya to transfer to DU power when battery LV set-point is reached. Can you compare its reliability to a separate LVD module?
Paano Mag-Install Automatic Transfer Switch Mula Solar Off-Grid To Distribution Utility ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-FvuGrnAPJDg.html
Pwede po ba na ilagay sa Normal power is 220v from Mainline DU, at sa reserve power naman ay 12v from the battery? Bali sa out put po ng Normal power para sa mga 220v bulbs, at sa out put naman po ng reserve power ay Para sa mga ilaw lng po at Cliff fans na 12v.
Sir pwede ko din po ba icharge sa SCC MPPT. ang nkaparallel.na set 1 sinopoly 90ah 12volt w/ bms 60. Set 2 32650 batteries 70ah w/. Bms 100ah. Balance lang po kaya magiging charge at pwd po b syang mapull charge. Slmat po s sagot..
Pwede na naka-parallel ang dalawang battery bank. Sa tanong nyo na kung mapupuno ba ay ibang usapin yan. Depende yan sa inyong solar panels at scc. Pakipanood ang video na’to para malaman nyo ang kalkulasyon para matiyak na puno ang battery bank sa maghapon. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-g-ABVnKArss.html
Sir mag tanong lng paano kung ganyan ang design Ng set up pwd bang kpg humina Ang battery dahil hapon na wla ng suply ang solar panel. Pwd po ba na AC ang mag supply para ma full charge ulit Ang battery?
Mga 188watts po.. balak ko kase naka ATS. Naka grid s magdamag.. bale priority ko ung grid if ever mag brownout lilipat lng sa solar automatic. Tapos sa araw naman isswitch ko sa manual naka solar. Palage kase brownout sa Mindoro. Mukhang maganda kase sir naka ATS kse kung magkakuryente sa magdamag di nako babangon pa para ilipat ung electricfan sa outlet kusa na sya mgswitch s grid since naka priority sa AtS ang grid.
Kung tutuusin ay ganito lang. Divide inverter power rating by system voltage, multiplied by safety factor na 1.25. Per dahil sa karamihan ng mga binibenta na SSR ay under rated, mas mainam na mas mataas ang bilhin.
Hello po si JF good day po meron po akng 5.5kw hybrid solar inverter Ask ko lng po kng ilang AMPERES po ang kailangan sa mga safety devices From solar panel: DC ISOLATOR SWITCH,DC MCB and DC SPD From Battery to Inverter: DC MCB From INVERTER to LOAD: AC ISOLATOR SWITCH,AC SPD and AC MCB THANKS A LOT SIR JF MORE POWER AND GODBLESS
Good day. Ang DC and AC circuit breaker lang ang magbabago ng value. Eto ang tutorial para sa circuit breaker. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-fte7cyZnHZU.html
Ang LVD module ay ginagamit kapag ang cut-off voltage ng inverter at battery na ginagamit ay hindi magkatugma, para hindi masagad ng 100% DOD (depth of dischrge) ng battery.
Good day. Kung babasahin nyo po ang specs ng SSR na gagamitin nyo, ay nakasulat po doon ang supported voltage maging AC man o DC. May nakasulat po mismo sa SSR kung anong voltage ang supported neto. 😊👍
Paano ang paraan Sir pag malalaki mga wire size na ginamit sa AC output Ng Inverter (SNAT 3kw) at batteries para maikabit sa LVD module at SSR ang wires. Maraming Salamat po
Sir ang ginamit ko yon jqx 62f 2z relay at lvd. Buti syang gamitin kc pag transfer sa du from solar hindi namamatay ang desktop computer pag ats kc namamatay ang desktop once na pumasok na ang power sa du.
@@JFLegaspi good day sir pa try yung ginamit ng ating ka LPP sir @Joel Rosales, 62f 2z relay at lvd. pang palit ba yun sa ats or dagdag lang gaya ng ssr relay. More power sir and God Bless
Sir ano po ba maximum current na kaya ng Lvd na gaya po ng gamit dito sa tutorial nyo po? Bibili na po sana ako kaso me mga nababasa po kasi akong mga reviews sa lazada na mabilis daw po syang mag init at baka daw po di tatagal. Wala naman po kasing naka indicate na current rating even po sir sa tutorial nyo po.
Good day. Ang dahilan kung bakit may mga "buy links" sa video description ay para mapag-aralan ang mga specs ng mga parts na nasa video tutorial. Ngayon, sa tanong na kung ilang amps ang kayang i-handle ng LVD mismo. Ang sagot ay 10A, nakasulat mismo sa maliit na relay ng LVD module. Pero kapag ginamit mo ang LVD module na walang external relay tulad ng SSR (solid state relay) mabilis masira yan, dahil ang trabaho nyan ay switching or triggering lang. So kailangan ng SSR or mechanical relay. Hindi ko alam kung sapat na ba etong paliwanag ko, kung hindi, manood ka lang sa iba ko pang mga tutorial videos. 😊👍
@@JFLegaspi ok na sir, naintindihan ko na po dahil napakalinaw po ng explanation nyo, sensya na sir very limited lang po nalalaman ko sa electrical at bago lang po ako sa solar, salamat po sir ng marami.🙏🙏🙏