Тёмный

Klein Tools CL380 AC/DC Digital HVAC Clamp Meter, 400A Auto-Ranging 

Sparky Channel
Подписаться 221 тыс.
Просмотров 82 тыс.
50% 1

Опубликовано:

 

6 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 83   
@SparkyChannel
@SparkyChannel 5 месяцев назад
Klein Tools CL380 AC/DC Digital Clamp Meter, 400A Auto-Ranging: Amazon: amzn.to/2UCigmU
@robbycumby8019
@robbycumby8019 2 года назад
I have this meter and it is a solid meter. Also to all you tubers especially in all the electrical world. Take a tip from this gentleman and use a wood pointer so we all see exactly what you are showing us . like a dowel or chop stick. Nice touch. Thanks
@SampleroftheMultiverse
@SampleroftheMultiverse Год назад
I have a old rental house built in 1928. I am worried that the Receptacle circuits might be pushing their 30 amp limits is there a way I can check the amps on the circuit without just blowing out fuses. I do not have access to the wires of the fuse box. I am thinking I can replace a fuse with one of those screw in light socket plug adapter and maybe have to plug in line splitter plus a load like a test light bulb or my receptacle tester then I can check the total amps being used in the house circuit. Please give me a sanity check before I blow something up. Do video if it’s a good idea. 9:03
@williamwatson9702
@williamwatson9702 3 года назад
I wonder why folks don't demo DC amp clamps on vids? A lot of meters don't measure DC amps to their owners frustration. Klein says this one does. Good video overall.
@coryulrich6489
@coryulrich6489 2 года назад
I'm here for the same
@stevofromiowa
@stevofromiowa 2 года назад
I agree. VERY frustrating!
@JerryRecords
@JerryRecords 3 месяца назад
I came for the same reason
@williammclaughlin2606
@williammclaughlin2606 4 года назад
Okay Scotty Kilmer
@SparkyChannel
@SparkyChannel 4 года назад
LOL!
@miguelmedina4687
@miguelmedina4687 4 года назад
@@SparkyChannel ha! I was thinking the same thing.
@coils1945
@coils1945 4 года назад
Baaahahahaaa I thought the same thing!!!
@tompickup4722
@tompickup4722 3 года назад
This would have been an awesome review if you would have used it in the DC clamp setting.
@TheCrash0veride
@TheCrash0veride 2 года назад
The dc clamp is shit. The dc amp setting deviates hard back and forth. I just got one and I’m in the process of returning it. I need it for low voltage electronics. And the dc amps even though it has a micro reading. It’s only to 200 micro amps. After that it’s a deadzone no read all the way up to 300 milliamps. As it won’t read anything over 200 in the micro setting. And won’t register anything until .3amps (300milliamps) it appears to have the entire range on the box. But this is untrue. This meter is another feature lacking wash from Klein. Fluke or bust.
@amedreyes1546
@amedreyes1546 4 года назад
Not sure whats the resolution on your old channel but we are glad to have you back!, i hope you can restore the old videos.
@SparkyChannel
@SparkyChannel 4 года назад
I'm praying that RU-vid can restore my channel. Thanks!
@RobinDobbie
@RobinDobbie 4 года назад
At the beginning of the video it sounds like you're equating the max-hold setting of the meter with inrush current measurement. I believe they are very different. Klein offers inrush measurement on the CL450 and the CL900, but not on this CL380. I'm not sure how quickly this meter samples measurements. I'm not sure how easy it is, or if it's even possible to get an accurate inrush measurement with this meter. Since there's some obvious editing at the beginning, I wonder how many tries it took to get that number? It would be interesting to compare side-by-side with one of their meters that specifically offers inrush measurements.
@coils1945
@coils1945 4 года назад
REV UP YOUR ENGINES!!!!
@SparkyChannel
@SparkyChannel 4 года назад
LOL! I know, Scotty sounds like me! 👍😎⚡️⚡️
@sebrofc
@sebrofc 3 года назад
Was thinking the same thing
@DRocker80
@DRocker80 3 года назад
They do sound a lot alike. I'd love to hear them have a conversation one day lol.
@tyylerduurden11
@tyylerduurden11 3 года назад
It does not toggle from ac to dc automatically,it’s on ac by default,you have to manually select dc via sel button
@joemancino9049
@joemancino9049 4 года назад
That capacitor is 10 microfarads (uF), not 10 nanofarads (nF).
@jedjed27
@jedjed27 4 года назад
I missed you sir. Is your original channel hacked? Glad you are now back sir.
@SparkyChannel
@SparkyChannel 4 года назад
Hi Jed! Yes, the original Sparky Channel got hacked and I lost 934 videos and 182K subscribers so I'm starting over. I'll be uploading a really neat new video Saturday that I hope is going to be really popular. I'm hoping that it will be fun for viewers and very educational as well. It's very unique and I worked really hard on it but it was fun. I hope you can check it out :)
@stanislavstan4150
@stanislavstan4150 4 года назад
Thank you Sparky
@SparkyChannel
@SparkyChannel 4 года назад
No problem, thanks!
@neilrankin9945
@neilrankin9945 2 года назад
I just bought a Klein CL390. For some reason I'm getting .32 V on a 120 Volt circuit. My killawatt is showing 117 Volts. Any ideas? I think it must be defective. Thanks.
@atomicorang
@atomicorang 2 года назад
You sort of sound like Scottie Kilmer which is a good thing.
@SparkyChannel
@SparkyChannel 2 года назад
LOL!
@atomicorang
@atomicorang 2 года назад
@@SparkyChannel I think the resemblance is uncanny… “rev up your engines!!”
@unionse7en
@unionse7en Год назад
similar minus scotts clickbait & yelling, thank goodness. Good video Sparky.
@MrRubenrivera9649
@MrRubenrivera9649 2 года назад
I have the cl390 and reads the same things this one does klein is some great meters as is their hand tools 🔧
@canadiantrucker9574
@canadiantrucker9574 4 года назад
Klein makes some good stuff but I really like Amprobe
@Galaxy-ez8mh
@Galaxy-ez8mh 2 года назад
Hi..i don't know wtf is ac dc a v or oem.. can you please help me find a meter clamp for a car which reads automatically the shit I'm putting the clamp multimeter on ?! Thanks!
@douglasbattjes3991
@douglasbattjes3991 Год назад
Does the 380 or 400 read DC nice video , they show the same in description as the 1000, only list AC thanks so much I did see at the 2:00 mark you checking AC & DC but only shows in the description as AC
@byroncordovabalcazar2448
@byroncordovabalcazar2448 3 года назад
I have a clamp meter model CL380 like the one in the video and the screen cannot read the numbers, only in dark places they read well. Is yours the same?
@JesusIsGod222
@JesusIsGod222 4 года назад
Great review . Thanka. I bought one.
@SparkyChannel
@SparkyChannel 4 года назад
Excellent, good choice.
@LoneStarPrepping
@LoneStarPrepping 3 года назад
Will this record the peak amps or watts during a clothes washing machine cycle, for example for me to see at end of cycle? I dont want to have to stare at my kill a wstt meter making mental note of when I might see peak watts or amps.
@rickytruong5994
@rickytruong5994 4 года назад
Thank you for the detailed review! I am close to making up my mind to purchase this meter. Is the Klein rare earth magnet accessory compatible with this? I'm wondering how it attaches to the back of the meter. Thanks!
@rasolis89
@rasolis89 4 года назад
Hey bud... the Ferads thing.. you see the symbol change from n to that other ų thing....lol... it became 10 to the 6.. MICRO ferads
@vcomments3484
@vcomments3484 3 года назад
Hello, I noticed that you use different Klein Tools clamp meters in different videos; which would be more than sufficient for typical house wiring/voltage?
@justanotheryoutuber5228
@justanotheryoutuber5228 3 года назад
Anybody know how to recalibrate temp? Mines off
@yrtuag
@yrtuag 4 года назад
Thanks for the review, Bill. I just purchased one yesterday. I lost my main meter so I picked up this one. Hoping my other one turns up. I have a couple of Fluke meters and both are on the fritz. The clamp meter, I'm not going to have repaired but the multi meter, fluke 77 series 2 has a display problem. What's your opinion as far as sending one in for repair that has some age to it?
@johncasor9698
@johncasor9698 Год назад
temp in ice water should be 32 DEG... not what you have i think... my book tells me to check temp meter with ice water should be 32 deg ???
@SparkyChannel
@SparkyChannel Год назад
Yes, but you would need to leave the probe in the ice water for a while.
@BretWrightSTUFF
@BretWrightSTUFF 4 месяца назад
@@SparkyChannel supposed to have equal ammounts ice and water by weight to calibrate and should be 32 deg F
@mpxz999
@mpxz999 3 года назад
Can I use that thermal probe inside my steaks? Very cool video! Thanks!
@OffGridandOutdoors
@OffGridandOutdoors 3 года назад
How many decimal points will it read down to in DC Voltage? I need a meter that will do 3 behind the decimal. Like 3.654vdc
@nathanaelwelch3551
@nathanaelwelch3551 3 года назад
It reads four sig figs
@mostlikelywedoitservices6926
@mostlikelywedoitservices6926 2 года назад
Does it have a magnet on the back?
@keanusofa
@keanusofa 4 года назад
I got the same meter and this is my first time using a meter. I was wondering is it normal for a meter to not zero out on the voltage setting?
@elena6516
@elena6516 4 года назад
That is explained in the instruction manual. It is electrical noise within the unit and is normal.
@MultiMeterChannel
@MultiMeterChannel 4 года назад
Ice water was 50 degrees?? It should have been 32.
@SparkyChannel
@SparkyChannel 4 года назад
Try it. You might find that it takes a while for the ice to cool the water. Have a great 4th of July!!!
@touche9239
@touche9239 3 года назад
For the future: fill a glass full of ice, then add just enough water to cover the ice. That way is a quicker and better freezing/melting point reference.
@cfldriven
@cfldriven 3 года назад
It defaults to AC voltage display unless you press the SEL to switch over to DC voltage. Might want to make better notes next time.
@Walter466
@Walter466 3 года назад
Cry me a river
@wt5390
@wt5390 4 года назад
Can you do current test with the leads?
@SparkyChannel
@SparkyChannel 4 года назад
Yes, but you have to break into the circuit. It's much easier with a clamp meter.
@mrblonde1231
@mrblonde1231 4 года назад
Can you test 110v
@wt5390
@wt5390 4 года назад
@@mrblonde1231 7
@urge251980
@urge251980 4 года назад
use it to test an dc current on alternator?
@canadiantrucker9574
@canadiantrucker9574 4 года назад
Yes, the dial knob has the symbol for both DC and AC amps.
@kwametwumasi8543
@kwametwumasi8543 3 года назад
That is what i was wondering could it be used for automotive applications ?
@mrblonde1231
@mrblonde1231 4 года назад
Can I use this to test phone lines?
@SparkyChannel
@SparkyChannel 4 года назад
Yes, it will work great for phone lines for continuity but I would suggest the new Klein Scout Pro 3 for voice, data and video testing.
@mrblonde1231
@mrblonde1231 4 года назад
Thank you
@SparkyChannel
@SparkyChannel 4 года назад
@@mrblonde1231 No problem, thanks!
@hebertglauber7503
@hebertglauber7503 4 года назад
Is CL2300 good?
@SparkyChannel
@SparkyChannel 4 года назад
The Klein CL2300 600A TRMS AC/DC Clamp Meter with Temperature is an excellent meter.
@Honk_Clank
@Honk_Clank 3 года назад
Direct sunlight is a no go on that screen 💩
@SparkyChannel
@SparkyChannel 3 года назад
Bummer!
@Pipefitr18201
@Pipefitr18201 2 года назад
💯 pretty much unusable in sunlight! It sucks because it’s a great meter otherwise.
@hitmakerscollective
@hitmakerscollective Год назад
rev your engines
@theastuteangler
@theastuteangler Год назад
Lol I get it
@abelvazquez6012
@abelvazquez6012 4 года назад
Unreadable Screen in Sunlight.
@SparkyChannel
@SparkyChannel 4 года назад
Thanks!
@susan7627
@susan7627 3 года назад
Hi 💥💥💥HOW DO I CHECK A 12 VOLT BATTERY ?💥💥💥
@TheCrash0veride
@TheCrash0veride 2 года назад
The fact that this tests diodes and capacitors and other things used in low voltage electronics is disgustingly offensive. Especially since this amp has a deadzone when reading dc amps from 200micro to 300 milliamperes. That’s a hefty zone. This meter is a trash. Klein has fallen off the wagon and is on the greedy warpath.
@gantfrost7749
@gantfrost7749 2 года назад
"The fact it tests diodes and capacitors is offensive"? Why? thats a good thing.
@TheCrash0veride
@TheCrash0veride 2 года назад
@@gantfrost7749 because it makes it seem like a perfect tool for small electronic projects. But you can’t even read anything under 1A. And if you want one that does that’s another $100 sum for a new meter.
@Fenderstratosphere98
@Fenderstratosphere98 Год назад
I disagree, these are marketed toward electricians and hvac techs. Not electronics engineers.
Далее
How to use a multimeter like a pro - Clamp meter
24:52
Просмотров 196 тыс.
5 Electrical Tools Every Homeowner Should Have
12:19
Просмотров 264 тыс.
4 Basic Electrical Testers & HOW TO USE THEM
15:24
Journey to the Temple: How to use a Line Splitter
4:21
Which Multimeter? New Techs ONLY!!!HVAC!
7:31
Просмотров 23 тыс.
Klein CL450 Differential Temperature HVAC Meter Review
13:45
Klein vs Fluke Clamp Ammeter | One CLEAR winner!
6:43