Тёмный

Ladder Diagram Basics #2 (Safety Control Circuit) 

Pete Vree
Подписаться 69 тыс.
Просмотров 129 тыс.
50% 1

This video walks you through one of your shop projects called Safety Control Circuit. Before you make a million comments on how bad this circuit design is... it is just a basic control circuit that helps students grasp the basics of how to design a rudimentary control circuit. Hope you enjoy it.

Опубликовано:

 

1 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 59   
@meganordz4336
@meganordz4336 7 лет назад
usefull. i think this control use for a machine that needed to push the button at same time to energized. like a press machine or any othe application base on the function.
@PeteVree
@PeteVree 7 лет назад
Hi Megan, Yes, that is the premise of the circuit. However, this is just a primer to get students used to wiring an 8 pin relay. The controls for a press have to be completely fail safe. Here is another video on the "Anti-Tie Down" Circuit for a press. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-5jT60c4UOyE.html
@robbe8858
@robbe8858 6 лет назад
The step by step info and diagram including the real relay helps . This is better explained than my tech teachers did at school . Thank you!
@MXTVidz
@MXTVidz 6 лет назад
You’re way better than my professor ! Keep up the videos !
@richardweimer7949
@richardweimer7949 5 лет назад
Pete you present a intermittent level class structure on circuitry (design, construction, component understanding and reasoning). It's very visual in scope, you only need ground level knowledge and a open mind. Please continue to enlighten us.
@bonnylasu7665
@bonnylasu7665 Год назад
Sir thank you very much. Can you explain which terminal numbers for the relay and contactors connecting?
@daveb9370
@daveb9370 3 года назад
It doesn’t specify, but I would wire both red lights in parallel after the second PB so you know if both are being held closed. Just my opinion, like you said, everyone does it their own way and the instructions are not very specific on certain things. 🙂
@Lebron3d
@Lebron3d 2 года назад
Do you know of any good references book that one can get to have handy at the shop to references to if one for get these steps. Thank you.
@paulcamacho9923
@paulcamacho9923 7 лет назад
Pete, thank you for the excellent explanation. I'm still learning more about motor control and my question is how about using both of CR2 normally open as aux. contact for PB2 and PB3 , jumper CR1 N/O to red lights?
@mundellengineeringlimited5703
@mundellengineeringlimited5703 7 лет назад
Great tutorial!
@flyingroo83
@flyingroo83 4 года назад
Your a legend mate ... explained so well thank you
@FM-bo1un
@FM-bo1un 3 года назад
Excuse me Mr.Pete but can you please explain why you are using contacts 2 and 7 for both coils? Shouldn’t you have two relays, one for each coil? Also when you energize the coil (2&7) both N/O contacts (1&3) (8&6) will close turning on both red lights. I read some questions and comments regarding this but still did not see my mistake. Can you please elaborate.
@xDlolpatrick
@xDlolpatrick 4 года назад
Thank you, Mr. Pete, for all the tutorial videos you made.
@cloudnine1499
@cloudnine1499 6 лет назад
Thank you very much Sir Pete
@franknielsen3562
@franknielsen3562 7 дней назад
I don’t see where is the second coil c2?
@michaelcostello6991
@michaelcostello6991 7 лет назад
Great video.
@brutuswarrior3732
@brutuswarrior3732 4 года назад
This and these tutorials are what I have been needing #Thanks
@whysoserious7914
@whysoserious7914 2 месяца назад
Where you get these text boxes?
@Liam-j6y
@Liam-j6y Год назад
it's good to see someone actually work to a specified checklist as opposed to just rambling on about how ladder works. puts it into a bit of perspective. thanks
@alexup7437
@alexup7437 5 лет назад
Hi, I didn’t get why with green lights you used only parallel without any contact from CR1, but with CR2 you made another and said that this only one way to do this. But what’s the difference?
@gregkail4348
@gregkail4348 10 месяцев назад
Thanks good video
@wakkawakka7624
@wakkawakka7624 Год назад
Great job!
@trevormckee8701
@trevormckee8701 3 года назад
I've been having trouble understanding this in my apprenticeship until now. Thanks man!
@dperez-tv1lr
@dperez-tv1lr 3 года назад
wire it up!
@mikeadler434
@mikeadler434 6 месяцев назад
👍👍
@marshallstephens7356
@marshallstephens7356 Год назад
Nice
@donjuan7427
@donjuan7427 5 лет назад
peter you are a very good guy teaching electrical control I really love and understand your puzles maybe dont cant explainme because Im not speak very good thankyou
@niqu1983
@niqu1983 5 лет назад
Honestly, i dont't understand of this idea and maybe i'm wrong, but: I think you are mixing ladder programming in PLC (LD) with electrical ladder diagram. (CR1/CR1 should have graphical symbols of electrical contacts instead of coils symbols which were used). Also, even if You stop pushing PB2/PB3, CR2 will be still energized because of CR1 hold contact, which will be still energized because of CR1 self-hold contact.
@PeteVree
@PeteVree 5 лет назад
Please read my comment below the video before throwing shade.
@Hohmies86
@Hohmies86 6 лет назад
Graduated with instrumentation deg in 2012 and never got a job in the field, stayed doing residential and minor commercial. These videos are definitely “jogging” my memory!
@jacobmediavillo367
@jacobmediavillo367 3 года назад
Keep it coming Pete...very informative indeed!
@ekhaamattar4400
@ekhaamattar4400 5 лет назад
Great video But I have a question !? When energizing the coil of relay 1 then will both contacts of 1 and 2 close simultaneously ? (Since they have the same coil)
@PeteVree
@PeteVree 5 лет назад
Yes 1 and 3, and 8 and 6 will change state and be closed simultaneously when the coil energizes.
@nglistrik
@nglistrik 4 года назад
Thank
@salehfarman3879
@salehfarman3879 6 лет назад
how do you connect a 400w 1ph capacitor run motor to a start/stop button?
@dannielgarcia4337
@dannielgarcia4337 3 года назад
Thanks for your videos!
@donaldcoulter6017
@donaldcoulter6017 6 лет назад
Thanks for all of the useful information. I find it easy to listen to listen and learn. Although I really like the references to "this bad boy", and showing your Canadian roots with "Beauty and Eh" Subscribing now - Take off Eh !!
@PeteVree
@PeteVree 6 лет назад
Thanks you hoser
@henrybartlett1986
@henrybartlett1986 5 лет назад
These are very useful. Many thanks.
@sherifhamed4095
@sherifhamed4095 7 лет назад
hello brother First of all thank you for this helpful session I have questions .. what if we directly put realy's two NO contact connected from feeld then the NO contact then the two red lights I think it also will work because the two lights wont switch on untill relay two is energized
@PeteVree
@PeteVree 7 лет назад
For sure. That would work as well. Thanks for the feedback.
@sherifhamed4095
@sherifhamed4095 7 лет назад
thank you so much
@saurabh9ism
@saurabh9ism 7 лет назад
Pete, really nice explanation. please upload more tutorials
@javierferrer4634
@javierferrer4634 4 года назад
Nice video!
@edburr3227
@edburr3227 4 года назад
BEAST!!!
@lukastaerk3933
@lukastaerk3933 4 года назад
Thanks!
@alexguna1675
@alexguna1675 6 лет назад
Thank you sir
@davidhaines4173
@davidhaines4173 7 лет назад
Thanks Pete.
@fatimah2878
@fatimah2878 5 лет назад
Thank you!!
@M0stBlunt3d
@M0stBlunt3d 7 лет назад
How can control relay 1 use COMMON 8 and NO 6? I thought you said in your last video both relays are independent? I thought CR1 can only use COMMON 1 and NO 3 and CR2 can only use COMMON 8 and NO 6. Great tutorial, man. Appreciated.
@PeteVree
@PeteVree 7 лет назад
Comm 1 goes with either 3 or 4, and Comm 8 goes with 5 or 6. Each relay (i.e. CR1 or CR2 has these two available contact pairs. Have a look at the diagram in the centre of the video beside the base for the contact placements.
@M0stBlunt3d
@M0stBlunt3d 7 лет назад
Pete Vree thanks for the quick reply. I think you meant to type Comm 8 goes with both 6 and 5. I agree that each relay has two sets of available contacts NO and NC for each. I'm just pointing out in the video it looks like mixing CR2 contacts with CR1 because you marked CR2 as utilizing 1 and 3
@PeteVree
@PeteVree 7 лет назад
No mixing up going on. CR1 has both 1 and 3 used on rung 2, and 8 and 6 on rung 3. CR2 has only 1 and 3 used on rung 4.
@M0stBlunt3d
@M0stBlunt3d 7 лет назад
CR1 and CR2 both can use 1 and 3? I thought 1 and 3 are specific to CR1 only and CR2 has to make use of 6 and 5.
@PeteVree
@PeteVree 7 лет назад
www.galco.com/images/mgcr/tdrsoxp-12v_cd.jpg
Далее
Ladder Diagram Basics #1
15:01
Просмотров 538 тыс.
Ladder Diagrams
36:46
Просмотров 17 тыс.
Провал со стеклянным хлебом…
00:41
Как снимали мой клип POLI - Котик
00:37
Motor Controls - Contactor and Power Circuit
13:18
Просмотров 137 тыс.
Basic Ladder Logic (Full Lecture)
36:05
Просмотров 422 тыс.
What is Ladder Logic?
8:19
Просмотров 600 тыс.
Motor Controls Tutorial - How to Read Ladder Diagrams
13:37
Radio Antenna Fundamentals   Part 1 1947
26:09
Просмотров 398 тыс.
PLC Basics: Ladder Logic
26:20
Просмотров 379 тыс.
Introduction to the Holding Circuit
6:37
Просмотров 47 тыс.
What is a PLC? PLC Basics Pt1
1:02:34
Просмотров 2,3 млн
Провал со стеклянным хлебом…
00:41