Тёмный

Limit of Blank (LOB), Limit of detection (LOD) and Limit of quantification (LOQ) | LOB,LOD and LOQ 

live biochemistry
Подписаться 6 тыс.
Просмотров 5 тыс.
50% 1

Hello all.. In this video I have explained about Limit of Blank (LOB), Limit of detection (LOD) and Limit of quantification (LOQ)
For PPT follow the link : docs.google.co...
#limitofblank
#limitofdetection
#limitofquantification
This channel would be helpful to MBBS, PG, NEET preparation, USMLE preparation , EXIT exam, NEXT exam, Nursing ,Physiotheraphy, Dental ,MSc, Biotechnology and B.Pharm students to understand the basic medical subject
My youtube link : / livebiochemistry
Don't forget to LIKE,COMMENT SHARE & SUBSCRIBE ...
Subscription link : www.youtube.co...
Chemistry and Metabolism of Carbohydrates : • Carbohydrates
· Chemistry and Metabolism of Proteins : • Proteins
· Chemistry and Metabolism of Lipids : • LIPIDS
· Enzymes : • Enzymes
· Vitamins : • Vitamines
· Minerals : • Minerals
· Hemoglobin Metabolism : • hemglobin metabolism
· Genetics/Molecular Biology : • Genetics | Molecular B...
· Molecular techniques : • Molecular techniqes
· Nucleotide Metabolism : • Nucleotide metabolism
· Organ Function tests : • Organ function tests
· Metabolism of xenobiotics : • Metabolism of xenobiot...
Follow me on
instagram :- / aggravat1616
Facebook - / ashish.agravatt
Twiitter : / ashu_dr
Telegram : t.me/livebiochemistry
Linkedin : / dr-ashish-agravatt-a15...
email : drashishagravatt@gmail.com
THANKS FOR WATCHING #biochemistry #livebiochemistry#drashishagravatt

Опубликовано:

 

11 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 7   
@KaloferChushkov
@KaloferChushkov 2 года назад
Thank you very much for making these, your tutelage is amazing and I'm sure everyone who has seen these videos is very grateful. I will be recommending them to my chemical pathology trainee colleagues here in Scotland. I was curious if you could answer why for LoQ you say CV can be 50% of TAE but then in the subsequent slide you say that within-run CV can be 25% and between-run CV can be 33%. Would it not be acceptable to get any combination of these values provided that the square root of the sum of their squares (i.e. total CV) remains 50%? Thank you again for your time and effort in making these!
@livebiochemistry
@livebiochemistry 2 года назад
Hi Sava Handijev. Thank you for your comment About CV of 50 % of TAE will be in case of assumption of 0 % bias Between CV 33% we can apply for between run and keep remaining 34 % for bias... I agree with you in doing square root of sum of squares to within run and between run . it will be total standard deviation.. but can not keep it to 50% as we have to keep space for bias also
@livebiochemistry
@livebiochemistry 2 года назад
if you have further query kindly mail on drashishagravatt@gmail.com and discuss further
@mohammedalseraji5342
@mohammedalseraji5342 2 года назад
I have old instrument Atomic Absorpance shimadzu 6800.How I can determine LOD of metals. I know Rang of standars.
@livebiochemistry
@livebiochemistry Год назад
Concepts remains the same .take 0 calibrator near by low calibrator
@mohammedalseraji5342
@mohammedalseraji5342 2 года назад
Thnx
@livebiochemistry
@livebiochemistry 2 года назад
Thanks for comment !!
Далее
Verification of reference interval
5:16
Просмотров 1,6 тыс.
Что думаете?
00:54
Просмотров 790 тыс.
A small kitten was dumped #cat #kitten #cutecat
00:41
LOD and LOQ
16:20
Просмотров 18 тыс.
Detection Limits
6:49
Просмотров 10 тыс.
LOD & LOQ/Validation Parameter/Vikrant Dhamak
6:42
Просмотров 10 тыс.
Что думаете?
00:54
Просмотров 790 тыс.