Medium voltage drives and synchronous transfer control 

Eaton
Подписаться 124 тыс.
Просмотров 8 тыс.
50% 1

Опубликовано:

 

8 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 9   
@sasanzeraati6248
@sasanzeraati6248 Год назад
Thanks a lot for the great video.
@lukeslingher6043
@lukeslingher6043 Год назад
Very informative.
@sohailjanjua123
@sohailjanjua123 Год назад
Hi, I like your video. Thanks
@hi-io6ry
@hi-io6ry Год назад
Hello, I have a question regarding VFD to mains synchronization. 1. Is mains reference signal taken from the VFD power supply? 2. The output waveform of VFD is PWM square with full DC voltage. Even if you van synchronize the voltage phase of the mains and the VFD output, how can you connect them together, without short circuiting?
@eatoncorp
@eatoncorp Год назад
Thank you for reaching out. Please visit shorturl.at/pKMY4 for more information on VFD power supply.
@AltKuyperian
@AltKuyperian Год назад
kW is actually 75% of HP, I would not consider those even "roughly" the same, and that's at unity PF. The amount of HP delivered to a load would be even worse, seeing as how many motors draw decent VARs.
@volodumurkalunyak4651
@volodumurkalunyak4651 2 месяца назад
You mixed up kW and kVA. For motor running with VFD, appproximate motor effiency * motor power factor (both at full load) should be close to 1HP/1kW. If result is > 1HP/1kW, users get some safety factor (like using buses rated at 400A with at most 350A).
@AltKuyperian
@AltKuyperian 2 месяца назад
@@volodumurkalunyak4651 Perhaps power factor may not play into HP calculations but the actual conversion of kW to HP is 0.746, so 75% like I said.
@volodumurkalunyak4651
@volodumurkalunyak4651 2 месяца назад
@@AltKuyperian power factor isnt incleded in the output HP number, but it is included in input Amps. All input conductors must be rated for sufficient current (power factor plays a role there).
Далее
Low-voltage switchgear
19:29
Просмотров 63 тыс.
Grounding and bonding: Definitions and details
12:42
Просмотров 90 тыс.
Они захватят этот мир🗿
00:48
Просмотров 502 тыс.
Нарвался на сотрудника ФСБ⚡️
01:00
Will A Guitar Boat Hold My Weight?
00:20
Просмотров 87 млн
Low vs Medium Voltage VFDs Webinar
43:22
Просмотров 357
Medium voltage motor controls | Eaton PSEC
9:17
Просмотров 2,2 тыс.
What is the Difference between VFD and Soft Starter?
7:30
How to choose a medium voltage VFD (Buying Guide)
16:41
VFD 101 Basics
15:52
Просмотров 920 тыс.