Micro800 Message MSG to Read a Controllogix or Compactlogix 

Tim Wilborne
Подписаться 84 тыс.
Просмотров 25 тыс.
50% 1

In this lesson we show you how to configure messaging to read data from a Controllogix or Compactlogix PLC into a Micro800 Micr820 PLC in Rockwell Automation's Connected Components Workbench software. We also have lessons on how to do the opposite.
Helping you become a better technician so you will always be in demand
Get the full details of this lesson at controls.tw/yt...
Items used in this video:
PLC Trainer controls.tw/yt...
The above links make these videos possible. Please use them!

Опубликовано:

 

20 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 114   
@TimWilborne
@TimWilborne 3 года назад
Thanks for watching! If you are looking for the complete Connected Components Workbench PLC Training series, visit twcontrols.com/micro800-connected-components-workbench-lessons
@viniciusmarquesalmeida9794
@viniciusmarquesalmeida9794 3 года назад
I really have to thank you for the last tip about "Swap"! Thank you so much!
@TimWilborne
@TimWilborne 3 года назад
You are so welcome!
@alonsohdzf
@alonsohdzf 3 года назад
Thanks for reuploading the video! Great explanations about the USINT and DINT!
@TimWilborne
@TimWilborne 3 года назад
Glad it was helpful Alonso!
@lucianoviana2288
@lucianoviana2288 3 года назад
Thanks, Tim. It helped me a lot. You won a subscriber.
@TimWilborne
@TimWilborne 3 года назад
Thanks for the sub Luciano!
@REXONCROSS
@REXONCROSS 3 года назад
Thanks Tim. great videos good bless your big heart
@TimWilborne
@TimWilborne 3 года назад
You are welcome!
@nando1968can
@nando1968can 2 года назад
Excellent video too clear explanation
@TimWilborne
@TimWilborne 2 года назад
Glad it was helpful Fernando!
@nando1968can
@nando1968can 2 года назад
@@TimWilborne Thank you sir,I did for Micro800 to compact logix in both sides, according to your 2 videos and it worked perfectly. We have a project in where we will use 11-13 plcs,we are checking this option or the other consumed and produced tags,what in your experience, do you recommend? Also in one video (I think the girl in the video is your wife),she said you have a control store(it that means you sell allen bradley stuff?,I´m sending this message from Mexico
@maheshmali9870
@maheshmali9870 3 года назад
We done this work OK thank you
@TimWilborne
@TimWilborne 3 года назад
Great 👍
@kriztopher32metalica
@kriztopher32metalica 2 месяца назад
Hello Tim. Thank you for your videos, they're so informative I have a question, if i want to send a string from a micro850 to a robot using tcp sockets, how could i do that?
@TimWilborne
@TimWilborne 2 месяца назад
I haven't played with sockets on the micro800 and can't recall if they are available.
@brianwallace1247
@brianwallace1247 3 года назад
In this video you talked about writing logic to check for connectivity problems, have you made that video or is that a video you will do in the future. Thanks in advance, Your videos are great!
@TimWilborne
@TimWilborne 3 года назад
Hi Brian, it is a future video, stay tuned.
@brianwallace1247
@brianwallace1247 3 года назад
I tried this and I am getting Status Error 224 SubError 4? Any suggestions?
@TimWilborne
@TimWilborne 3 года назад
@@brianwallace1247 That isn't a common error code, looks like you'll have to dig into the CIP specification to find that one.
@James-oj6lk
@James-oj6lk Год назад
Tim I love your videos! I know its along the same vein, but could you show us how to send 2 separate analog signals via message MSG from L32 compact logix to L71 controller over ethernet? I need to move two speed requests(inputs) from L32e to L71, to use as analog outputs to 2 VFD's at other location in plant, they are on existing network? Thanks!
@TimWilborne
@TimWilborne Год назад
Great question James because that isn't along the same vein. You want to use Produced and Consumed tags. Here is a video on that. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-ABOAHyLcgSM.html
@jojoon1937
@jojoon1937 Год назад
Still you did not gave the answer for how to fix that dropping signal back to 0 ? Could you please explain how to fix that data blink to zero
@ayomikunsamuel3715
@ayomikunsamuel3715 3 года назад
Tim, i enjoy watching your videos and they are sincerely informative. I still consider myself a littlw above beginner in terms of PLC programming. For instance, if i want to write a PLC program that controls a conveyor system in terms of package counting. I want to know how you would approach something like this? What are the step by step procedures you would take in solvinv this problem? Do you have any resources you would suggest to me to guide me in solving this problem? I hope you get what i am driving at. I want to be able to relate with my PLC programs from the standpoint of how each rung is populated
@lauragardner9819
@lauragardner9819 3 года назад
I really enjoy watching these videos. I have just started looking into the ML800 series for a couple small projects. I have some questions though, have you converted a MicroLogix 1400 program to CCM using the MicroLogix Library Converter Tool? What are your thoughts? And do you think you might do a video on it?
@TimWilborne
@TimWilborne 3 года назад
Hi Laura. I haven't and based off of the RsLogix 500 to Studio 5000 converter tool, I wouldn't recommend it. The main reason is it makes you skip taking advantage of one of the best features of CCW, the tag based addressing. I've seen some programs that have used these conversions and there is nothing worse then looking in a Studio 5000 or CCW program and finding a tag array named "N7". I hope that helps and thanks for watching!
@Sparkies...
@Sparkies... 3 года назад
Hi Tim thanks for the great video Could you please share us the solution of how to message data from micro Logix 1400 to micro 800 or vise versa Thanks in Advance
@TimWilborne
@TimWilborne 3 года назад
It is on the list, stay tuned.
@frazman187
@frazman187 2 месяца назад
Tim, I have a program where I am using this method to communicate from one main 820 to three sub 820's. I had an issue where I lost communication with the third, but the system did not shut down like I had anticipated. In short, I believe I have a flaw in my comm-loss detection and I am wondering if you have a solid way to detect communications loss.
@TimWilborne
@TimWilborne 2 месяца назад
That would be worthwhile for a video but I don't believe I have ever done it. The issue is, even if you get the error bit, then next time your trigger your message instruction, it will set it back to 0 until it times out again. I would put a Go Look for a 1, examine on, for the error bit then two MOVs with the sources being the errorid and the suberrorid. That way you get the actual error values and they will stay once the error bit is cleared. Then you can use the DN bit of the message and MOV 0s to the stored codes one the connection is reestablished.
@wandersonpereira9884
@wandersonpereira9884 Год назад
Hi Tim. Props on the video. I am a massive fan of yours! I'd like to know why I can not find any information about connecting a Micro820 to a MicroLogix 1100 and making them communicate over Ethernet. I would like to see if it's possible. Thank you.
@TimWilborne
@TimWilborne Год назад
That would be a good one, I should do a general PLC to PLC messaging video.
@wandersonpereira9884
@wandersonpereira9884 Год назад
@@TimWilborne that would be awesome. I've seen only Modbus RTU communication between Micro820 Modbus RTU master and MicroLogix 1100 slave to exchange data. I am afraid it's not possible to use MSG block and ethernet ports to do so. I can do it with a CompactLogix 1769-L32E and a MicroLogix 1100, but not with the Micro820 and ML 1100. I would be very thankful if you help our community.
@TimWilborne
@TimWilborne Год назад
Yes it is possible. I've done it before, I just never made a video on it.
@arz4712
@arz4712 Год назад
Hello,Tim! If l need to get REAL data types, do I do the same using the CIP instruction? Just convert REAL data types in USINT?
@TimWilborne
@TimWilborne Год назад
Copy it to a dint then copy it to a real on the other side. Depending on the brand, you may have to swap bytes or words
@arz4712
@arz4712 Год назад
@@TimWilborne thank you!
@arz4712
@arz4712 Год назад
Hello, Tim! How can I get data from a non-Allen Bradley controller such as a B&R X20CS1030? Do I need to use the MSG_MODBUS command? How to do it?
@TimWilborne
@TimWilborne Год назад
I'm not familiar with that service but modbus is a protocol that many brands support.
@serkanuysal682
@serkanuysal682 2 года назад
thank you for telling , but i will ask you , can we use same things from micro8xx to micro8xx? if we can't use this shape how is the use?
@TimWilborne
@TimWilborne 2 года назад
Yes, you can
@Redwolf11555
@Redwolf11555 3 года назад
I really enjoy all the videos you make. I am having a problem and it is setting the communications setup in the Micro820 to talk to a ControlLogix Rack. Currently the IP address of the ethernet card in the PLC Rack is 192.168.1.40 and is in slot 9 with the Processor in slot 0. Im new to working with the 820's and so far the communication path setup is where im struggling. I do have it setup on the ControlLogix side where it reads from the micro820.
@TimWilborne
@TimWilborne 3 года назад
Make sure you use the complete path which would be 192.168.1.40,1,0
@nando1968can
@nando1968can 2 года назад
Hello Tim, good morning how can we solve the blinking issue ? we added more time and the control voltage increases, with less time it goes too low but with much time it increases almos the control vdc voltage(24), is there another solution, you mentioned you will do a video with a possible solution but I can not finding,thanks for you amazing help.
@ProfessorMurray
@ProfessorMurray 3 года назад
Have you done connections between Raspberry Pi and M820 using Modbus IPC? I am quite sure it is possible, but there are no videos about it.
@TimWilborne
@TimWilborne 3 года назад
It is possible. I know some people that have done it. I'm playing with a raspberry pi right now, I'll see how much extra time I have on the project.
@jokatz740
@jokatz740 3 года назад
Hi Tim, thanks for all the helpful videos! I was wondering if it is possible to write to a oampactlogix controller from a micro820? Or is it not possible because of mismatch in data types? Thanks!
@TimWilborne
@TimWilborne 3 года назад
It is possible to write but I prefer to read because it makes to easier when looking at the program too determine where the data is coming from.
@khoanguyen4780
@khoanguyen4780 3 года назад
good game
@ronzzz30
@ronzzz30 3 года назад
Thanks for the video... Though I have one doubt how did you select port as 4? What's the logic behind... Thanks. ✌
@TimWilborne
@TimWilborne 3 года назад
That tells the message instruction to go out the Ethernet port.
@iotamation
@iotamation 2 года назад
​@@TimWilborne After comparing the read message path between this video and its counterpart, I noticed that in the CompactLogix the port was set to 2 versus 4 in the Micro820. Would that difference in port number be the primary difference in messaging with the Micro820 and a CompactLogix? I am having an issue with allowing a third party device to write to three array tags in a Micro820. The manufacturer advertises the device communicating to CLX/CPX and when asked about the Micro800 line, they said it wouldn't be an issue. Now that I have the devices connected and not communicating, I had them inspect the three array tags in the Micro820 program to verify they were as instructed, their "Allen-Bradley" expert only could replay with "maybe it can't talk to the Micro820 like the Control and CompactLogix" and left it at that.
@kolyangod2715
@kolyangod2715 Год назад
Hello! with DINT and SINT is understandable. And if you need to read the BIT value? How to do it?
@TimWilborne
@TimWilborne Год назад
A bit value is simply 1 of the 16 bits of an INT or 1 of 32 bits of a DINT
@kolyangod2715
@kolyangod2715 Год назад
@@TimWilborne THX!
@TimWilborne
@TimWilborne Год назад
You are welcome!
@michaellee4986
@michaellee4986 2 года назад
Hey Tim, great video! Is it possible to read and write between 2 micro820's?
@TimWilborne
@TimWilborne 2 года назад
Yes, you do it the same way. One thing I didn't realize when making this video is you can specify the data type instead of doing the conversion, it is on the list to cover.
@bowhunt9968
@bowhunt9968 Год назад
What would the target config path be if you have to connect through an Enet module that resides in a chasis with the processor that you are trying to read?
@TimWilborne
@TimWilborne Год назад
Not following you, the Micro800 isn't a chassis based PLC. Each communications port on it has a assigned number, then the IP address of the destination device.
@bowhunt9968
@bowhunt9968 Год назад
@Tim Wilborne I set up a Micro850, with a message exactly like in your video, to read data from a Controllogix processor on the same network. The controllogix processor is connected to the network through an Ethernet module. The enet cable is not hooked directly to the Controllogix processor, like it is in your lab setup. I set the target config path to the IP address of the Controllogix processor, but the Micro850 is not reading the data. I am guessing that it is because I am going through an Enet module on the way to the Controllogix processor. I started the address with "4," like you stated. I am just wonder what the address should be when routing through the Enet module that resides in the Controllogix chasis. Will it be different if I am not connecting the Enet cable directly to the Controllogix processor?
@TimWilborne
@TimWilborne Год назад
@@bowhunt9968 I was going through a module too. What's your full path?
@JohnSmith-lv8xk
@JohnSmith-lv8xk 3 года назад
I don't see a link in the description for the opposite video ??
@TimWilborne
@TimWilborne 3 года назад
Here is how to read from a Micro800 to a Controllogix. twcontrols.com/lessons/how-to-read-data-from-an-allen-bradley-micro800-plc-to-a-controllogix-compactlogix-plc-using-message
@ofc2463
@ofc2463 2 года назад
Hi Tim thank you for these wonderful tutorials. I am new to PLC. I am struggling with concept of tags vs classid/instance-id/attributename-id. Somewhere i see tags and somewhere i see a combination of classid/instance-id/attributename-id. Both used to read/write to memory location. Can you explain this?
@TimWilborne
@TimWilborne 2 года назад
Class instance and attribute have to do with communicating to other devices through CIP. For the most part, the manufacturer will tell you which ones to use to communicate with their particular device.
@eizzuddinnawawi5349
@eizzuddinnawawi5349 3 года назад
Hi Tim. Tq for the video. I want to ask you regarding TCIP to PC data transfer. My project is to collect analog data from Analyzer and transfer it to Micro 870. after that, the data analog will be transferred to PC. Is the command is the same?
@TimWilborne
@TimWilborne 3 года назад
Probably not the same. You will need to see what compatible communication methods there are between your analyzer and the Micro870.
@osvaldolorenzo6835
@osvaldolorenzo6835 Год назад
Hello, is there a way to read real tags out of a compactlogix without using the copy instruction? Really great video btw!
@TimWilborne
@TimWilborne Год назад
No, you would need to convert them on both ends
@osvaldolorenzo6835
@osvaldolorenzo6835 Год назад
@@TimWilborne Actually, i found a way to do it, using the copy only on the micro820 that i was using to read. i could send you the pdf i used if you like.
@TimWilborne
@TimWilborne Год назад
Yes post it for us please
@osvaldolorenzo6835
@osvaldolorenzo6835 Год назад
drive.google.com/file/d/1Imr9xUEg1XTTDD3u7JeBgljX0KR0QCFC/view?usp=sharing
@OldePhart
@OldePhart 2 года назад
Exactly which HMI platform is developed in the background there ?
@TimWilborne
@TimWilborne 2 года назад
It is a Panelview 800. Here is a series I did on it. twcontrols.com/allen-bradley-panelview-lessons
@nmgarcia0330
@nmgarcia0330 3 года назад
Hey Tim! Thanks for the videos! I'm having trouble accessing my Micro800 remotely. Could you please help
@TimWilborne
@TimWilborne 3 года назад
Hi Nathan, I'm short on time this week so I would post your question at plcs.net
@daltoncavinsbassin3889
@daltoncavinsbassin3889 Год назад
I am looking to msg some bool bits between 2 micro 850 controllers do you have anything on that?
@TimWilborne
@TimWilborne Год назад
For some reason I never have. You would use the CIP read. I'll put it on the list to do something with
@lucassegoviaolan5370
@lucassegoviaolan5370 3 года назад
Thanks for your videos,they are very helpful, I have a question, How do I convert data from the MSG_MODBUS funcions that stores itself into two spaces of the array? example, I read a register that is allocated in modbus device by tag 400001-400002 and arrives to master and sotores in Local_Addr [1] and Local_Addr[2]? How do I make a value from that? Thanks in advance Mr.
@TimWilborne
@TimWilborne 3 года назад
Have a look at the COP instruction.
@lucassegoviaolan5370
@lucassegoviaolan5370 3 года назад
@@TimWilborne Thank you for helping Mr. This COP function works greately!!
@willpowerfan
@willpowerfan 3 года назад
Tim, I'm working with a Micro820 and need to convert the RTC time to seconds, I'm trying to keep track of how long a machine has been cycling so I can calculate a rate/time. I can read the RTC but can't figure out how to convert that to a DATE data type (number of seconds since 1-1-1970). Is there an easy way to do this that I'm missing? Thanks for the video's, they have helped me on more than one occasion.
@TimWilborne
@TimWilborne 3 года назад
Hi Rob, that would take some work and while it might be a fun challenge, but I'm not following how you are going to use it to see how long a machine has cycle. Why not just use an RTO instruction that is enabled whenever the machine is cycling? The hours, minutes, and seconds are easy enough, then you would have to use IF then's to determin the value to put in for the month since each month doesn't have the same amount of days. Then you have years...which are doable through an equation to account for leap years but good grief...that's a lot of work.
@willpowerfan
@willpowerfan 3 года назад
@@TimWilborne Thanks Tim, I did the whole seconds thing fairly easily in a Compact Logix by calling GSV with a 'currentvalue' argument (but it's in microseconds), I was hoping the Micro820 might have the same thing that I didn't know about. I'll probably touch base with Tech Support and if I don't get the answer I want I'll go with your RTO suggestion.
@willpowerfan
@willpowerfan 3 года назад
@@TimWilborne FYI, I found a workaround: format the RTC date data into a string using ANY_TO_STRING (formatting YYYY-MM-DD), then do ANY_TO_DATE on that and follow that with ANY_TO_DINT. It returns the number of seconds since 1-1-1970 to that day. Then add it to the time variable formatted in seconds of day.
@TimWilborne
@TimWilborne 3 года назад
@@willpowerfan That is a a good one, thanks for sharing Rob. What are you doing with it from there? I'm still trying to follow the reason to do this compared to the RTO.
@willpowerfan
@willpowerfan 3 года назад
@@TimWilborne We're feeding a continuous process and need to keep track of running time as well as down time or 'time between jobs' so we can properly put a 'gap' between jobs. For 14 years I've been working with a Micrologix 1400 and actually did the number-of-seconds-since 1-1-2000 on that processor due to the limits of timers on that platform. Now that I know a TON can handle a preset of over 49 days I'll probably work with that on the Micro820.
@Findley_Tyler
@Findley_Tyler Год назад
Hey Tim, due to the maxumum TCP connections of 16, would I be able to cycle through differnt IP strings on the LogixTargetConfig.Path to send and recive data to more then 16 devices? I'm not woried about scan time.
@TimWilborne
@TimWilborne Год назад
You don't need to change the path, you simply need to stagger your messages. Check out this video on cascading timers to give you some ideas. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-xcLdacN3SZs.html
@Findley_Tyler
@Findley_Tyler Год назад
@@TimWilborne Lets say I wanted to talk to 20+ devices, are you suggesting 20 staggared messages to these 20 IPs?
@TimWilborne
@TimWilborne Год назад
@@Findley_Tyler Yes
@Findley_Tyler
@Findley_Tyler Год назад
@@TimWilborne Just curious if you have ever tried to manipulate the Tag with the IP Address on each scan by changing the 4th Octet with a micro 820 to have more than 16 modbus connections?
@TimWilborne
@TimWilborne Год назад
You might be able to but you are making life difficult on yourself. If you do that, you'll have to manage all the error IDs to troubleshoot the system. If you stagger the MSG instruction, when one isn't working, then you'll just have to lookup the error ID. What are you hoping to gain?
@MaNemUmar
@MaNemUmar 3 года назад
Hey Tim, i have a somewhat specific question. For my application, i have an array of BOOLs holding my HMI input bits. As i want to reset them at the end of every scan cycle to mimic momentary operation, i would want to zero all the bits in the array systematically rather than resetting every bit with an unlatch instruction. Previously, i was intending to use micrologix and had found a work around with the MOV instruction by moving a Zero integer (N7:0) to the (B3:0) (this worked, my application is small-scale so 16 bits was sufficient). Any suggestions for a similar approach in CCW?
@TimWilborne
@TimWilborne 3 года назад
You could create a dint data type and have 32 bits in it to address individually and use the same mov instruction. But why not configure your buttons on your HMI for momentary operation?
@MaNemUmar
@MaNemUmar 3 года назад
Tim Wilborne I plan on using the micro 820 with the remote lcd for other purposes (cheap means to adjust timer parameters, and product type without online edits through CCW). I’m not sure on how flexible/user friendly the unit is in terms of creating basic HMI inputs functionality (start/stop functionality, alarm acknowledge). Furthermore my client wants to keep the HMI logic/alarming programmed within the PLC (that’s how it’s done for other PLCs on-site).
@nicolastoro6826
@nicolastoro6826 Год назад
Hello Tim, thank you for the video, i have a trouble trying to connect a control logix 5561 with micro 850 and i see in the rslinks request a EDS file for the micro800, can be that the problem? Because i have not connection yet
@TimWilborne
@TimWilborne Год назад
No, the EDS file is just so your PC can communicate with it. Check your path, it is the most likely problem. Also look up the error code you are getting.
@nicolastoro6826
@nicolastoro6826 Год назад
Thanks for the answer, the error in the instruction is errorid 224 suberrorid 5, I talked to people at rockwell and they don't know how to solve the problem
@TimWilborne
@TimWilborne Год назад
@@nicolastoro6826 That usually had to do with the instance or object. Check your tag and data type
@nicolastoro6826
@nicolastoro6826 Год назад
ok, I solved it, in the route, in addition to 4,192.168.X.X, it is necessary to add the rack number and the destination slot, therefore it remains something like 4,192.168.X.X,1,0 in my case, all this because the PLC controllogix it is very old.
@poritoshkundu6974
@poritoshkundu6974 2 года назад
I having Conserve EM6400EM meter Communicating through modbus RS485 How to convert two word data into one double word
@Sastavlog007
@Sastavlog007 6 месяцев назад
Dear sir,how to data transfer energy meter to micro 850 ,micro 850 to controllogix please make the video to this topic (energy meter →micro 850→controllogix) please
@TimWilborne
@TimWilborne 6 месяцев назад
Many of them are Modbus, here is a playlist on that. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-qcF4m7rPjkw.html
@jeanellepillay7596
@jeanellepillay7596 3 года назад
Hi, how are you? I need some urgent help. I am using a Micro850 plc and I have a banner iVu camera. I can not seem to establish communication (read/write) using the MSG instructions. Any assistance would be great. PS. The address is correct . I have doubled checked.
@TimWilborne
@TimWilborne 3 года назад
I'm running a training class this week. I would post your question at PLCs.net
@jeanellepillay7596
@jeanellepillay7596 3 года назад
Thank you
@adhamshorafa5338
@adhamshorafa5338 3 года назад
iam trying to read data from onther plc but it dosent read anything any help pls
@TimWilborne
@TimWilborne 3 года назад
What error code are you getting?
@adhamshorafa5338
@adhamshorafa5338 3 года назад
@@TimWilborne Error id 33 Sub error id 48
Далее
Новый фонарик в iPhone с iOS 18
00:49
Просмотров 181 тыс.
Turn a Micro800 into a Modbus TCP Server
10:25
Просмотров 18 тыс.
Lesson 1- Introduction to Micro850 PLC
29:54
Просмотров 47 тыс.
Setting up a MSG instruction Studio 5000
11:31
Просмотров 13 тыс.