Mitsubishi A800 vfd parameter setting system. 

S.m. Electrical work
Подписаться 548
Просмотров 4,1 тыс.
50% 1

Видеоклипы

Опубликовано:

 

29 окт 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 12   
@mdabulhasan2912
@mdabulhasan2912 Год назад
nice parameter satting
@s.m.electricalwork8475
@s.m.electricalwork8475 7 месяцев назад
thanks
@uzzalhossainrana2038
@uzzalhossainrana2038 10 месяцев назад
Super❤
@s.m.electricalwork8475
@s.m.electricalwork8475 7 месяцев назад
Thanks
@MESSAGEOFBOOKS-24
@MESSAGEOFBOOKS-24 4 месяца назад
Terminal mode,keypad mode set korbo kibave?
@s.m.electricalwork8475
@s.m.electricalwork8475 4 месяца назад
P 79 group a giye. 0 r 1 set korlei hobe
@MESSAGEOFBOOKS-24
@MESSAGEOFBOOKS-24 4 месяца назад
bahi akhane,79 a je 1,2,3, kon number set korle ki mode a kaj korbe?jemon 1 - set korle keypad naki tarminal etc.are A series sob parameter ki same
@s.m.electricalwork8475
@s.m.electricalwork8475 4 месяца назад
Vai amader office a akta dekhlam...terminal mode 2 te set kora ase
@zniwtiblbox2608
@zniwtiblbox2608 4 месяца назад
السلام عليكم Please OL error
@s.m.electricalwork8475
@s.m.electricalwork8475 4 месяца назад
Stall prevention (overcurrent) When the output current of the inverter increases, the stall prevention (overcurrent) function activates. The following section explains about the stall prevention (overcurrent) function. During acceleration When the output current (output torque under Real sensorless vector control or vector control) of the inverter exceeds the stall prevention level (Pr.22 Stall prevention operation level, etc.), this function stops the increase in frequency until the overload current decreases to prevent the inverter from resulting in overcurrent trip. When the overload current has reduced below stall prevention operation level, this function increases the frequency again. Description During constant-speed operation When the output current (output torque under Real sensorless vector control or vector control) of the inverter exceeds the stall prevention level (Pr.22 Stall prevention operation level, etc.), this function reduces frequency until the overload current decreases to prevent the inverter from resulting in overcurrent trip. When the overload current has reduced below stall prevention operation level, this function increases the frequency up to the set value. During deceleration When the output current (output torque under Real sensorless vector control or vector control) of the inverter exceeds the stall prevention level (Pr.22 Stall prevention operation level, etc.), this function stops the decrease in frequency until the overload current decreases to prevent the inverter from resulting in overcurrent trip. When the overload current has decreased below stall prevention operation level, this function decreases the frequency again. Check that the Pr.0 Torque boost setting is not too large. The Pr.7 Acceleration time and Pr.8 Deceleration time settings may be too short. Check point Check that the load is not too heavy. Check for any failures in peripheral devices. Check that the Pr.13 Starting frequency is not too large. Check that Pr.22 Stall prevention operation level is appropriate. Gradually increase or decrease the Pr.0 setting by 1% at a time and check the motor status. (Refer to page 577.) Set a larger value in Pr.7 Acceleration time and Pr.8 Deceleration time. (Refer to page 278.) Corrective action Reduce the load. Try Advanced magnetic flux vector control, Real sensorless vector control, or vector control. Change the Pr.14 Load pattern selection setting. • The stall prevention operation current can be set in Pr.22 Stall prevention operation level. (Initial value is 150%.) The acceleration/deceleration time may change. Increase the stall prevention operation level with Pr.22 Stall prevention operation level, or disable stall prevention with Pr.156 Stall prevention operation selection. (Use Pr.156 to set either operation continued or not at OL operation.)
@mdshantoisiam9750
@mdshantoisiam9750 7 месяцев назад
এটা অটোমেটিক অফ হয়ে যায় করনীয় টাপিপিং কোন সিগনাল আসে না চলতে চলতে হঠাৎ অফ হয়ে যায়, প্রত্যেকটা কন্ট্রোলিং এবং পাওয়ার টার্মিনাল ঠিক আছে, এবং কন্ট্রোল এবং পাওয়ার ব্রেকার ট্রিপ হয় না, শুধু ইনভার্টার চলতে চলতে অফ হয়ে যায়?
@s.m.electricalwork8475
@s.m.electricalwork8475 7 месяцев назад
ইনভার্টার এর ডিসপ্লে অফ হয়ে যায়, নাকি রান সিগন্যাল অফ হয়ে যায়?
Далее
PORTAL SPAMMER🤬🤬🤬| Doge Gaming
00:19
Просмотров 1,9 млн
Smart Sigma Kid #funny #sigma #memes
00:26
Просмотров 7 млн
Mitsubishi A800 VSD settings uss Remote & manual
4:40
A800 and SSCNET
4:33
Просмотров 901
Stray Kids "Stray Kids" Video
3:25
Просмотров 3,3 млн