Тёмный

MS03b. [Siemens Motion Control] TIA Portal Technology Object (TO) Configuration [4/10] 

Electrical Automation Hands-On
Подписаться 22 тыс.
Просмотров 23 тыс.
50% 1

#TO #TIAPortal #MotionControl
Next: MS03c • MS03c. [Siemens Motion...
Playlist: • Motion Control
MS01. Video Series Open Speech
• MS01. [Siemens Motion ...
MS02. 9 Common Questions About Siemens Motion Control
• MS02. [Siemens Motion ...
MS03a. Single Axis Control - Project Introduction
• MS03a. [Siemens Motion...
MS03b. TIA Portal Technology Object (TO) Configuration
• MS03b. [Siemens Motion...
MS03c. Reset, Power, Home, and MoveJog Instructions
• MS03c. [Siemens Motion...
MS03d. Move Absolute, Relative, Velocity, Stop, and Halt Instructions
• MS03d. [Siemens Motion...
MS03e. Download Axis and Program into PLCSIM, OB91 Buffer Overflow Solved
• COM18. ModbusTCP Clien...
MS03f. Online Axis Test via Axis Control Panel
• MS03f. [Siemens Motion...
MS03g. Rotary and Linear Motion Control Online Test
• MS03g. [Siemens Motion...

Наука

Опубликовано:

 

5 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 24   
@selimalan8145
@selimalan8145 3 года назад
Very useful channel. Thank you for being such a channel Greetings from Turkey
@electricalautomation
@electricalautomation 3 года назад
Thanks Buddy, Welcome!
@maza6357
@maza6357 3 года назад
Thank you for great videos
@electricalautomation
@electricalautomation 3 года назад
My pleasure! Thanks! I am working on the encoder/high pulses counter of S71200. Those videos are coming soon!
@AnimSparkStudios
@AnimSparkStudios Год назад
Great effort
@hamzajmili92
@hamzajmili92 3 года назад
Thank you for this effort
@electricalautomation
@electricalautomation 3 года назад
Thanks! Welcome to my channel!
@2tan90
@2tan90 2 года назад
thank you
@electricalautomation
@electricalautomation 2 года назад
Welcome! Enjoy!
@TheGreen18
@TheGreen18 3 года назад
Great Videos Is it possible to Axis that is not from Siemens with the TO? For example Beckhoff?
@electricalautomation
@electricalautomation 3 года назад
99% the Motion control and the servo drive will be the same brand. The key reason is the communication fieldbus protocol as well as the telegram. If you do have to cross the brand, most common way is to use analog output to control the drive speed and read the encoder use the encoder module.
@richardbanda2817
@richardbanda2817 Год назад
Great explanation and that you. Would you perhaps have a video of setting up two synchronous axes?. If so, may you kindly direct me to that please.
@electricalautomation
@electricalautomation Год назад
Hope this video would be helpful ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-hie46Yd37uI.html
@marcshiftsolve2947
@marcshiftsolve2947 Год назад
Is it possible to use s7-1200 cpu instead of s7-1500 cpu's? and as well as to use stepper motor rather than servo motor?
@electricalautomation
@electricalautomation Год назад
You can view the video, it is using the DC motor, but the idea is the similar MS04a. Setup Positioning Axis via Analog Output, DC Motor, and Encoder ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Od4cqjMst4Q.html MS04b. Program DC Motor Positioning Control via S7-1200 and TIA Portal ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-WNVbgi67HfQ.html
@EngOmar-kz9qv
@EngOmar-kz9qv 3 года назад
Thank you very much for your effort . in simotion scout i was using _LineModule_Control function block to enable 36KW SLM infeed but now i am using TIA PORTAL V13 and i don't found this function block . Please how can i find and using this function block ? . Regards
@electricalautomation
@electricalautomation 3 года назад
Simotion is different system comparing with T-CPU or S7-1500T. In TIA Portal, power up a Axis need to use "MC_Power"
@EngOmar-kz9qv
@EngOmar-kz9qv 3 года назад
@@electricalautomation if i want to enable 36KW smart line infeed, also i have to use MC_Power ?
@electricalautomation
@electricalautomation 3 года назад
@@EngOmar-kz9qv No, sorry, MC_Power is used to power up axis. For the Smart Line Infeed enable, maybe search "xx Infeed xx" FB, the "Linemodule" may be changed to "infeed"
@elnursucayev6625
@elnursucayev6625 2 года назад
Thank you. very useful lessons. Please show how you can instal all tia portal version on one PC
@electricalautomation
@electricalautomation 2 года назад
They can be installed together. You'd better install from the lower version V12 to V17 higher version one by one. It is not recommended to install multiple versions of WinCC Professional in one system. Regular Step7 and WinCC advanced should be no issue.
@elnursucayev6625
@elnursucayev6625 2 года назад
@@electricalautomation Thank you very much
@michalkall9206
@michalkall9206 Год назад
Hello, I cant see in my TIA portal option for Virtual Axis, u know where can be problem?
@electricalautomation
@electricalautomation Год назад
Are you using S7-1500 PLC? Which revision of TIA Portal are you using? I assume you are using S7-1200 PLC or old revision of TIA, they don't support virtual axis.
Далее
ЮТУБ БЛОКИРУЮТ?
02:04
Просмотров 544 тыс.
Automation Tasks: V90 Positioning Axis Tuning
7:54
Просмотров 47 тыс.
TIA Portal: OB40+ - Hardware Interrupts (Digital)
11:59
MS09. How to Choose Siemens Telegram For Motion Control
37:12
TIA Portal SINAMICS V90 PN position control
10:20
Просмотров 8 тыс.
Мой новый мега монитор!🤯
1:00
Просмотров 600 тыс.
📱магазин техники в 2014 vs 2024
0:41