Тёмный

MS05c. [Siemens S120 #2] SINAMICS S120 Configuration and Commissioning via Startdrive TIA Portal 

Electrical Automation Hands-On
Подписаться 22 тыс.
Просмотров 25 тыс.
50% 1

#STARTER #Startdrive #S120
Before: [S120 #1]. S120+STARTER • MS05b. [Siemens S120 #...
Next: [S120 #3]. One Button Tuning SINAMICS S120. • MS05d. [Siemens S120 #...
Siemens Control Playlist: • Siemens Controls
Motion Control Playlist: • Motion Control
TIA Portal drive integration with SINAMICS Startdrive
new.siemens.com/global/en/pro...
SINAMICS Startdrive V17 Download
support.industry.siemens.com/...
Application example Entry ID: 109743270 Configuring a SINAMICS S120 with StartDrive
support.industry.siemens.com/...
Which hardware and functions of SINAMICS G130, G150, S120, S150 and SINAMICS MV are supported by SINAMICS Startdrive V15, V15.1, V16 and V17 ID: 109761180
support.industry.siemens.com/...
----------------
MS05a. [Siemens S120 #0]SIMAMICS S120 Motion Control Series Open Speech (S7-1500 + S120)
• MS05a. [Siemens S120 #...
MS05b. [Siemens S120 #1] SINAMICS S120 Configuration and Commissioning via STARTER
• MS05b. [Siemens S120 #...
MS05c. [Siemens S120 #2] SINAMICS S120 Configuration and Commissioning via StartDrive TIA Portal • MS05c. [Siemens S120 #...
MS05d. [Siemens S120 #3] One Button Tuning S120 via STARTER and TIA Portal Startdrive
• MS05d. [Siemens S120 #...
MS05e. [Siemens S120 #4a] Setup PROFINET Connection Between S7-1500 PLC and S120 Servo Drive
• MS05e. [Siemens S120 #...
MS05f. [Siemens S120 #4b] Setup Motion Technology Object (TO) to Control S120 Servo Drive
• MS05f. [Siemens S120 #...
MS05g. [Siemens S120 #5] SINAMICS STO Safety Torque and SS1 Safe Stop vis Safety PLC
• MS05g. [Siemens S120 #...
MS05h. [Siemens S120 #6] How to Tune the TO Positioning Closed Loop Gain Kv in TIA Portal
• MS05h. [Siemens S120 #...
MS05i. [Siemens S120 #7] Use Motion Control Function Blocks to Control S120 Servo Drive
• MS05i. [Siemens S120 #...
MS05j. [Siemens S120 #8] S120 Servo Drive - Changing Velocity On the Fly
• MS05j. [Siemens S120 #...
MS05k. [Siemens S120 #9] SINAMICS S120 Torque Limitation, Torque Reduction
• MS05k. [Siemens S120 #...
MS05l. [Siemens S120 #10] SINAMICS S120 Velocity GearIn
• MS05l. [Siemens S120 #...

Наука

Опубликовано:

 

6 фев 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 38   
@gelearn2362
@gelearn2362 2 года назад
Thank you very much for the lesson
@electricalautomation
@electricalautomation 2 года назад
Welcome!
@bartw4245
@bartw4245 2 года назад
very, very helpful:) thx
@electricalautomation
@electricalautomation 2 года назад
Glad it helped! Welcome!
@derina.maleek9408
@derina.maleek9408 2 года назад
You nailed it
@electricalautomation
@electricalautomation 2 года назад
Thanks! My friend!
@bhagyodayasinghjadhav7951
@bhagyodayasinghjadhav7951 2 года назад
Very good...
@electricalautomation
@electricalautomation 2 года назад
Thank you! Cheers!
@aminfathy216
@aminfathy216 2 года назад
Thank you good one 👍.....>3
@electricalautomation
@electricalautomation 2 года назад
Thanks! I am very busy these days, the next video will be launched slightly delay, but will be.
@vorapobautomation9760
@vorapobautomation9760 2 года назад
Good Thank you
@electricalautomation
@electricalautomation 2 года назад
Welcome 😊
@movies1774
@movies1774 2 года назад
Very good Sir
@electricalautomation
@electricalautomation 2 года назад
Thanks and welcome
@user-ch1ep4hi7q
@user-ch1ep4hi7q Год назад
goooood
@electricalautomation
@electricalautomation Год назад
Thanks! Enjoy
@damianhl5448
@damianhl5448 2 года назад
Very nice video. I have one question. The CU320-2 PN can only be used with S7-1500 CPU if i want commission in stardrive (i'm using stardrive v17)? If i want connect to a s7-400 i need to commission the sinamics in starter?
@vorapobautomation9760
@vorapobautomation9760 2 года назад
How can do it in TIA ?
@electricalautomation
@electricalautomation 2 года назад
If you are using S7-400, you can not use the 'TO'. You can use the position loop in the CU320, then the S7-400 just send position command.
@vorapobautomation9760
@vorapobautomation9760 2 года назад
Is the CU320 can use in startdrive with S7-400 ?
@alejandrojulian804
@alejandrojulian804 9 месяцев назад
It can works with the S7 1200 PLC too@@electricalautomation
@ariancontrol2430
@ariancontrol2430 Год назад
hello thank you for useful video! i have a sinamic cu320 version 2.6.2 with CBE profinet card and i want to have it in TIA portal but there is not such model in TIA hardware catalogue!! is it possible to add this model in tia portal ? if yes how?
@electricalautomation
@electricalautomation Год назад
I would recommend using Starter software and ' auto config' function, you can view from ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-9odur-A1_lI.html
@alejandrojulian804
@alejandrojulian804 9 месяцев назад
So good your tutorial series, i have a question, how i know what kind of memory cp works with the CU 320-2 PN, please help me :)
@electricalautomation
@electricalautomation 9 месяцев назад
'memory cp'? not sure what do you mean. Thanks watching!
@veys9655
@veys9655 9 месяцев назад
how to prevent when we stop and start the cpu or cut off the power of control panel to loss home position ? I want that when I set home position once, then I wanna keep it always. it doesn't matter then whether I cut off the power or cpu stop. Can you please help ?
@electricalautomation
@electricalautomation 8 месяцев назад
Using multiple revolutions absolute encoder for your servo drive.
@veys9655
@veys9655 8 месяцев назад
@@electricalautomationBut I'm already using absolute encoder ? can't I do it with Control unit?. I mean CU320 in startdrive side ?
@devendrachowdary2333
@devendrachowdary2333 14 дней назад
I am not able to connect the plc S7-1212C with the drive S120 CU310-2 Pn
@electricalautomation
@electricalautomation 13 дней назад
S7-1200 (v4.x) can not use 'TO' to control S120. You can use 'GSD' method and EPOS telegram 111 to control S120.
@vatsalthaker2122
@vatsalthaker2122 2 года назад
Hello sir... please resume the series....
@electricalautomation
@electricalautomation 2 года назад
Thanks watching, yes, the Step3 will be launched tomorrow. I am very busy these days, sorry for releasing delay.
@shahzaib1994
@shahzaib1994 Год назад
Hello I am Using 1 CU with 2 Drive of Servo. I am using telegram 1 for Both Drive & Telegram 390 for CU. I am using profibus connection with s7300. With Programming Blocks sfc14 & sfc15. With DB. I have a Problem that only One Drive is Sending & receiving Data. Both CU & Drive 2 Show No Telegram in Interconnection setting. Could you please help me
@electricalautomation
@electricalautomation Год назад
Have you set the telegram 1 at the drive side? Why you are using the telegram 1 (the speed control) for S120(a high end servo drive). Aslo your question is far away from this video topic, I would recommend contact Siemens support for your application, my feeling is that you are directing not quite direction for using your control devices.
@shahzaib1994
@shahzaib1994 Год назад
@@electricalautomationYes I am using Telegram 1 for both 2 Drive. But in My Program I call sfc14 & sfc15 3 Times. 1 for CU, 2 for 2nd Drive, 3 for 3rd Drive but it only read Sfc of Drive One CU & Drive 2 Register not Sending & receiving. is there any Method to Increase Profibus Cycle. I think it is Profibus Cycle Issue.
@electricalautomation
@electricalautomation Год назад
@@shahzaib1994 This link should be helpful support.industry.siemens.com/cs/document/8894584/micromaster-4-(mm4)-sinamics-g120-(cu240s-d-dp-dp-f-pn-pn-f)-essentials-for-profibus-and-pkw-mechanism-?dti=0&lc=en-CA
@dmitrijbozhok
@dmitrijbozhok 2 года назад
Good afternoon. Does anyone have a SINAMICS Startdrive V14 SP1 S120 under TiaPortal V14 SP1?
@electricalautomation
@electricalautomation 2 года назад
support.industry.siemens.com/cs/document/109746466/sinamics-startdrive-v14?dti=0&lc=en-WW support.industry.siemens.com/cs/document/68034568/sinamics-startdrive-v14-sp1?dti=0&lc=en-DE
Далее
ЮТУБ БЛОКИРУЮТ?
02:04
Просмотров 544 тыс.
SINAMICS S120 Setup in TIA Portal (STARTDRIVE)
21:41
Просмотров 4,4 тыс.
Why The Windows Phone Failed
24:08
Просмотров 226 тыс.
Мой новый мега монитор!🤯
1:00
Просмотров 600 тыс.
КРАХ WINDOWS 19 ИЮЛЯ 2024 | ОБЪЯСНЯЕМ
10:04