MSA | Part - 7 | What is Linearity study ? | Measurement System Analysis | ௭ளிய தமிழில் விளக்கம் 

New Mechanical Mind
Подписаться 34 тыс.
Просмотров 4,4 тыс.
50% 1

Format download link
drive.google.c...
T - table download link
drive.google.c...
Facebook: www.facebook.c...
Instagram: / newmechanicalmind
Twitter: / nmechanicalmind
Let's improve our knowledge in Industry
Subscribe here : / @newmechanicalmind8818
Your likes and sharing is important to grow our channel.
Kindly do and support.
Other useful links
• what is SPC | Part - 1...
• MSA | Part - 1 | What ...
• Poka yoke | What is Po...
• PFMEA | Part - 1 | Pr...
• What is PPM | Parts P...
• What is 7QC tools | Pa...
• What is Quality Alert ...
• What is One Point Less...
• What is 8D Report ? | ...
• PPAP | Part -1 | What ...
MSA | Part - 7 | What is Linearity study ? | Measurement System Analysis | ௭ளிய தமிழில் விளக்கம்
• MSA | Part - 6 | What ...
Can contact me through
newmechanicalmind@gmail.com
#linearitystudy#whatislinearity#newmechanicalmind

Опубликовано:

 

21 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 56   
@newmechanicalmind8818
@newmechanicalmind8818 3 года назад
Let's improve our knowledge in Industry Subscribe here : ru-vid.com/show-UCbsoHyXxtAelbMYicLaHQGQ
@tn6049
@tn6049 3 года назад
Very well explained sir, million dollar explanation for both fresher and intermediate people. Thanks a lot
@newmechanicalmind8818
@newmechanicalmind8818 3 года назад
Thanks for your support. Keep watching and sharing
@gowthamg5179
@gowthamg5179 2 года назад
GOD GIFTED YOU TO ME. actually i have 4 years of experience in quality department, but no one teached me like you.... you indirectly helping to my future. thankyou sir..... am expecting a video related to IATF all 10 sections explained with excel that we using for functionally. please kindly do this for us sir...
@newmechanicalmind8818
@newmechanicalmind8818 2 года назад
Hi Gowtham, it is already in our list.
@SKShivaKarnan
@SKShivaKarnan 3 года назад
Your explanation are very super. I am waiting for your gd and t video and other videos. Pls boost up your videos. THANK you
@newmechanicalmind8818
@newmechanicalmind8818 3 года назад
Thank you bro.I will try my best
@akashganesan8010
@akashganesan8010 Год назад
THANKS for very clear explanation sir
@newmechanicalmind8818
@newmechanicalmind8818 Год назад
Thank you Akash
@haribabuchandrasekaran2398
@haribabuchandrasekaran2398 3 года назад
Very useful Mohan. Thanks for great effort Can you guide us for central limit theorem please
@newmechanicalmind8818
@newmechanicalmind8818 3 года назад
Will upload soon
@haribabudhakashanamoorthy8875
@haribabudhakashanamoorthy8875 2 года назад
Sir, your explanation is excellent, pls upload MSA ANOVA Method, thank you
@newmechanicalmind8818
@newmechanicalmind8818 2 года назад
OK Haribabu, will be plan in future
@haribabudhakashanamoorthy8875
@haribabudhakashanamoorthy8875 2 года назад
Thank you Sir
@Samynathan_SDM
@Samynathan_SDM 3 года назад
Hi Sir, In 5.52 Minutes, you have calculated 1-alpha/2 by subtracting the one side risk value from 1 But in your BIAS video (MSA Part -3 ) at 17.13 minutes you have mentioned 1-alpha/2 is equal to the confidence level But we already assumed the confidence level is 95% As per the BIAS video, the 1-alpha/2 value is 0.95 But in this video 5.52 minutes, the 1-alpha/2 value is 0.975. Please clarify the doubts Thankyou sir
@newmechanicalmind8818
@newmechanicalmind8818 3 года назад
Hi samynathan, You are right about calculation. But, i have checked and not found that 1-alpha/2 value mentioned as 0.95 (pls tell time in video) Actually confidence level is 95% In Bias study we are taking lower value and upper value by two tail method. So that confidence level is taken as 1-alpha/2.
@Samynathan_SDM
@Samynathan_SDM 3 года назад
@@newmechanicalmind8818 @New Mechanical Mind @New Mechanical Mind thankyou for clarification... Now I am clear sir... You were correct....You didn't not mention 0.95 value to 1-alpha2.? I said you have mention 1-alpha value = confidence level in bias video (MSA part -3 ) At 17.13 minutes. So I had confused at little bit. Now I am clear.. Thankyou for your continuous response.
@arivanandhana583
@arivanandhana583 3 года назад
ANOVA & Range method is coved means - MSA is fully completed
@newmechanicalmind8818
@newmechanicalmind8818 3 года назад
They are not used mostly in industries. Will plan in future.
@imkabilan
@imkabilan 2 года назад
Kindly explain for what type of instrument which type of MSA study has to be conduct. Instrument Vs MSA study
@newmechanicalmind8818
@newmechanicalmind8818 2 года назад
Hi friend, in our msa videos it is clearly mentioned that what are all the msa studies applicable for instrument and gauges.
@imkabilan
@imkabilan 2 года назад
Or kindly explain for what kind of measurement which type of MSA study has to conduct Measurement vs MSA study to carry on
@newmechanicalmind8818
@newmechanicalmind8818 2 года назад
MSA is applicable for any kind of variable and attribute measurement. But, we have to follow the procedure for msa studies during the study
@imkabilan
@imkabilan 2 года назад
Ok sir , understand
@SKShivaKarnan
@SKShivaKarnan 3 года назад
Bro what is Ppap tolerance Mass control tolerance How the above tolrance related to six sigma and then 3 sigma Pls explain.
@newmechanicalmind8818
@newmechanicalmind8818 3 года назад
Bro, i think you are asking Cpk for initial process & ongoing process. For initial process study it should be >1.67 after that for ongoing process it should be >1.33. Total process variation is equal to 6 sigma. Hope i have cleared your doubt. Otherwise ask in detail.
@arivanandhana583
@arivanandhana583 3 года назад
sir , pls upload the ANOVA method
@newmechanicalmind8818
@newmechanicalmind8818 3 года назад
It is not used mostly in industries. Will plan in future.
@aruns4243
@aruns4243 Год назад
Sir, Some gauges are only used to measure a single part. In this case how to calculate linearity study?
@newmechanicalmind8818
@newmechanicalmind8818 Год назад
As informed Linearity study will be checked by selecting various range of products. If instrument is used for a single product, that instruments to be changed (exchanged from one part to another as a defined period) for uniform wear and tear.
@mgraj15
@mgraj15 Год назад
Hi sir my doubt is ybar , if calculate the ybar is 2e-5 ,. How to calculate 5.59e-15 explain sir
@newmechanicalmind8818
@newmechanicalmind8818 Год назад
Hi Govindarajan, your doubt is correct. When taking 4 decimal places your answer may come. But the excel sheet is taking more than 10 decimal points and sum is coming 2.797e-14 (very very negligible difference between + and - values) When taking average to that value 2.797e-14/5, the answer will be 5.59e-15. Pls check with format by adding more decimal points in y values.
@imkabilan
@imkabilan 2 года назад
Sir, through browsing I had found, MSA Manual 4th edition. The procedures you used to explain and content, method to conduct each studies were obsolutely matched. But I have also found BOSCH measuring manual sir. In that,the way of study conduct and procedures, method and even formulas were very different from MSA MANUAL4th edition. They calculating Cg and Cgk for measuring instruments. Query-1: Is this method of MSA Manual is correct or both of the MSA and Bosch approach are correct? Query-2: What is Cg and Cgk for measuring instruments and why that are calculating? Kindly explain it sir.
@newmechanicalmind8818
@newmechanicalmind8818 2 года назад
Hi friend, following MSA manual is correct and valid during IATF audit. I will plan to explain about Cg and Cgk in future.
@imkabilan
@imkabilan 2 года назад
👍
@uthayawinner1988
@uthayawinner1988 2 года назад
Sir, How about Range method and ANOVA method? Pls explain
@newmechanicalmind8818
@newmechanicalmind8818 2 года назад
Hi Uthaya ANOVA method will come in future
@uthayawinner1988
@uthayawinner1988 2 года назад
@@newmechanicalmind8818 Ok sir, Thank you.......
@akashganesan8010
@akashganesan8010 Год назад
i have one doute sir . how to find summation of y and y bar value sir my doute is summation of y = 2.79776E-14 . WHAT is E , PLS explain sir also Ybar value is 5.59552E-15 what is E
@newmechanicalmind8818
@newmechanicalmind8818 Год назад
Hi Akash, E-14 means 10 power minus 14. ie, 5E-14 means, 0.00000000000005
@akashganesan8010
@akashganesan8010 Год назад
@@newmechanicalmind8818 t.q sir
@SKShivaKarnan
@SKShivaKarnan 3 года назад
And so Document no lam yappdi kudukuranga In-qa-wi001 How these number is made
@newmechanicalmind8818
@newmechanicalmind8818 3 года назад
It is based on our wish, no restriction
@sangitbanik513
@sangitbanik513 6 месяцев назад
Probability for what?
@newmechanicalmind8818
@newmechanicalmind8818 4 месяца назад
Near to accurate value
@sushilk3464
@sushilk3464 Год назад
Sir please explain in English also
@newmechanicalmind8818
@newmechanicalmind8818 Год назад
Hi Sushil, i am doing this work part time only. So it is difficult to upload videos in English version. Will try to increase the English word in future.
@arivanandhana583
@arivanandhana583 3 года назад
Y bar average value is not come
@newmechanicalmind8818
@newmechanicalmind8818 3 года назад
Hi Anbu Ariva, download the format again and enter the value correctly. Already format is checked before uploading.
@SHANKARSHANKAR-pz6jq
@SHANKARSHANKAR-pz6jq 3 года назад
Bro T test table link kudukala?
@newmechanicalmind8818
@newmechanicalmind8818 3 года назад
Hi shankar, now check in description box. Download link is added
@SHANKARSHANKAR-pz6jq
@SHANKARSHANKAR-pz6jq 3 года назад
Tq so much bro
@invincibleman1258
@invincibleman1258 Год назад
How to read goodness of fit and acceptance of slope?
@newmechanicalmind8818
@newmechanicalmind8818 Год назад
Hi friend, your content is noted. will try in future
@muralidharamb5238
@muralidharamb5238 2 года назад
Sir very clear explanations thank you
@newmechanicalmind8818
@newmechanicalmind8818 2 года назад
Thank you Murali for your support. Keep watching and sharing our videos
Далее
ACCURACY OF MEASUREMENT: BIAS, LINEARITY & STABILITY
12:00
Beginning Engineers: Gage R&R ANOVA
26:09
Просмотров 16 тыс.
Measurement of Uncertainty  (MU)
29:15
Просмотров 20 тыс.