Тёмный

My septic air pump will not turn on! 

Wholesale Septic Supply
Подписаться 2,8 тыс.
Просмотров 33 тыс.
50% 1

Опубликовано:

 

22 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 33   
@johnacord6224
@johnacord6224 Месяц назад
Best vedio yet. All the others showed the older version. So thank you, thank you, thank you. I thought I was from another planet 😊
@and0uille
@and0uille 11 месяцев назад
Thank you, I had changed the Diaphragms and was puzzled at why it was not working... Fixed it in 5 minutes after watching your video!
@brentellender8651
@brentellender8651 6 месяцев назад
Great video. I just replace my pump diaphragms but the pump still wasn't working. Watched your video and went and reset the switch and the pump works perfectly. Saved me having to buy a new pump for $400! Well done.
@melissaharpster3835
@melissaharpster3835 Год назад
Thanks for your help! Knowing about the plastic safety switch just fixed my Hiblow!
@wholesalesepticsupply9801
@wholesalesepticsupply9801 Год назад
So glad the video helped you.
@mcrawfordinc.1422
@mcrawfordinc.1422 Год назад
You’re awesome. I learned something new and got my unit running after watching this.
@wholesalesepticsupply9801
@wholesalesepticsupply9801 Год назад
Thank you our goal is to educate people on each individual part.
@franginmhd
@franginmhd Год назад
Thanks for the video, really helped me out and was about to buy a new unit but only needed to order a replacement kit👍
@dannydaniel623
@dannydaniel623 Год назад
Great video and did a great job explaining everything.
@MrErpman
@MrErpman 7 месяцев назад
Mine went out and i rebuilt it using a kit. What no one told me was the "screw" on top was a breaker and i had to align the slot with the arrow. Once I did that it worked. Only took about 20 minutes.
@RaleighRonsClassics
@RaleighRonsClassics 7 месяцев назад
Any links to the safety switch and diaphragm kits? I have that exact unit.
@kfelix2934
@kfelix2934 Год назад
Thanks for this video , I just fix my unit but was used to the scew type. I had replaced my aerator like 3 years ago and this new unit split the diagphams. So I got 3 years out of the unit. My aerator sits under a big concrete cast shield. Do you think this is causing the hiblow80 to get two hot? I see other systems where the aeratopr is sitting out in the open. So I'm assuming they will run much cooler.
@wholesalesepticsupply9801
@wholesalesepticsupply9801 Год назад
Test where actually done couple years ago and we sent some housing for aerators and out in the open was actually the best result followed by a open on both ends cover. None of the aerator manufacturers actually know who started the cover idea but it wasn’t a good one. On the old rotary vane units it was but in diaphragm units it’s not necessary.
@RaleighRonsClassics
@RaleighRonsClassics 7 месяцев назад
Maybe I missed it but model and brand you are working on in the video?
@rosanneschillings254
@rosanneschillings254 Год назад
Mine came on & worked for an hour or so. I took it apart again and it looked like the new diaphragms were already warping around the edges! I bought a Hiblow XP 80 instead. It is replacing the Hiblow HP 80. I don’t see where there is a place for the air tube on the XP though.
@wholesalesepticsupply9801
@wholesalesepticsupply9801 Год назад
Possible you bought a fake rebuild kit. The real ones will be engraved on the diaphragm and chamber block.
@Mr.PeabodyTheSkeptic
@Mr.PeabodyTheSkeptic Год назад
Thanks for the help
@srconceptscomau
@srconceptscomau 8 месяцев назад
Great video, thanks
@letyoscarcornejo5365
@letyoscarcornejo5365 Год назад
Can you provide the link of the replacement slide switch I’m trying to find it on y’all website but I can’t seem to find it
@wholesalesepticsupply9801
@wholesalesepticsupply9801 Год назад
www.wholesalesepticsupply.com/products/hiblow-top-safety-switch-assembly-with-screw www.wholesalesepticsupply.com/products/hiblow-sw03-slide-switch Two different kinds of
@twayne62
@twayne62 8 месяцев назад
The plastic screw broke on mine can i replace it with a regular screw
@wholesalesepticsupply9801
@wholesalesepticsupply9801 8 месяцев назад
No if it broke the diaphragm is tore as well. Screw comes with the kit to fix the unit. I have yet to see a screw broke on a running unit and the diaphragm no needing to be replaced.
@majorsounds
@majorsounds 2 года назад
What turns the Aerator on and off? Does it stay on 24 hours a day?
@arnaldo35
@arnaldo35 Год назад
Yep, 24 hrs unless you use a timer.
@majorsounds
@majorsounds Год назад
@@arnaldo35 is there a video that shows how to setup with a timer?
@arnaldo35
@arnaldo35 Год назад
@@majorsounds Just buy a wall plug timer from the hardware store and connect the pump. Bear in mind, your septic will start to smell if you don't have enough aeration.
@VegasRT500
@VegasRT500 Год назад
Video didnt show how to replace the magnet diaphragm.
@wholesalesepticsupply9801
@wholesalesepticsupply9801 Год назад
We have a different video for that.
@erictherrien6174
@erictherrien6174 2 года назад
Hi , i have a hiblow HP-80 that i got from you guys and it only lasted 4 years and the diaphragms ruptured so i changed them and now onces it's fixed (with new diaphangms) the pump will stop after two hours of running and the core is blazzing hot. can you help me out ..Thanks
@wholesalesepticsupply9801
@wholesalesepticsupply9801 2 года назад
Where did you get the kit. If it wasn’t from a hiblow dealer you might have got a fake kit. You could need a new diffuser as well.
@arnaldo35
@arnaldo35 Год назад
I tried the cheap Chinese diaphragms from ebay and they lasted about 3 days. The rubber goes rock-hard and it doesn't pump air causing the pump to overheat. I replaced them with genuine diaphragms and it worked for about another week. Then the actuator rod broke in half, no doubt from the stress caused by the inflexible rubber in the cheap diaphragms. The genuine parts are a total rip off, but they are the only ones that use epdm rubber.
@wholesalesepticsupply9801
@wholesalesepticsupply9801 Год назад
@@arnaldo35 the Chinese ones are epdm it’s just that there is thousands of different kinds of epdm. The units run 24/7 and flex 30 times a second that’s 946,080,000 a year that’s roughly 2-4 billion times in there average life. Just cleaning the air filter and sometimes not even that. Cheaper than a moth on city sewer so it all depends on how you look at it.
@wholesalesepticsupply9801
@wholesalesepticsupply9801 Год назад
@@arnaldo35 the Chinese ones probably ruined the unit.
Далее
Hiblow HP-80 aerator rebuild - How to
13:53
Просмотров 93 тыс.
Ребенок по калькуляции 😂
00:32
Просмотров 148 тыс.
Your Septic System: Worst Mistakes
16:44
Просмотров 1,7 млн
HIBLOW Air Pumps - Checking Electrical Continuity
6:47
Aerobic Septic System Air Pump Replacement
15:36
Просмотров 11 тыс.
Warning About Septic Tank Aerators
3:34
Просмотров 155 тыс.
DIY Replace a Septic Tank Pump
17:39
Просмотров 242 тыс.
Ребенок по калькуляции 😂
00:32
Просмотров 148 тыс.