New Heating And Air Conditioning System Installation -Start To Finish- 

The DIY HVAC Guy
Подписаться 294 тыс.
Просмотров 153 тыс.
50% 1

All my favorite HVAC tools: www.amazon.com/shop/thediyhva...
#1 Source for HVAC equipment: hvacdirect.com
Use my discount code 1MJTDLG4GM70 for an extra 3% off!
IF YOU ARE IN NEED OF GUIDANCE WITH YOUR HVAC SYSTEM, whether it is diagnosing a bad part, replacing your system, or help with sizing, check out our membership program here: / diyhvacguy
For a small monthly fee of $50, you will get assistance from myself when it comes to your hvac needs, whether it's sizing, diagnosing, or locating the correct equipment.
⚠️ Disclaimer:
This video is for educational purposes. Any and all HVAC repair work is done at your own risk. Before handling any type of refrigerants, an EPA 608 certification is required by law. The DIY HVAC Guy channel is not responsible for any possible damages or injuries caused by the use or misuse of the provided information.
The DIY HVAC GUY is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.
If you are looking for a customer managment software to help fun your business, check out Jobber! This is the software I use every day that saves me time and helps me continue to grow my business.
Jobber: The #1 operations management software for home service businesses - Free 14-day trial + Exclusive discount: go.getjobber.com/diyhvacguy

Опубликовано:

 

11 авг 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 217   
@hitekrednek66
@hitekrednek66 Год назад
Great install sir! You make it all look so easy. Enjoyed as always. Keep up the good work!
@planetvance
@planetvance Год назад
Wrong, he left out the whole charging the system with refrigerant thing.
@VanquishSoReal
@VanquishSoReal Год назад
@@planetvance The ac units come factory charged. when he opened the valves all the way he was releasing the stored refrigerant
@user-gv4tx6lc5v
@user-gv4tx6lc5v Год назад
Keep up the good work you have a gift for this bro cause you make it look easy
@taitran5091
@taitran5091 11 месяцев назад
everything you did in this video is awesome
@larrybell4599
@larrybell4599 Год назад
This was very informative. Thank you.
@wick1952
@wick1952 Год назад
Great team work 👍👍👍👍💯💯💯 very informative, Thank you
@PhanOT11
@PhanOT11 7 дней назад
I have an old Goodman with R-22. Soon I’ll have to replace it with a new 3 ton Goodman and R134A.
@guitarcrappy
@guitarcrappy 10 месяцев назад
Thanks for all of the great videos. I have been watching all of them. I will be swapping out my home AC and Heating units this next spring. The AC is from 1968, sears (still works great), and furnace is not much newer. The evaporator coil is in a huge box above the furnace that also deals out all of the out going ductwork. Would you just replace the evaporator coil and not the box or take down the whole thing and rebuild it all? I am looking forward to the patreon membership a month or two before I start the project. Keep up the great videos!!!
@jeremeyplace1969
@jeremeyplace1969 Год назад
Great Install and Instructional Video, thank you for all the time you invested!
@diyhvacguy
@diyhvacguy Год назад
Of course thanks for watching! Hope you stick around for great informative future videos with the heating season coming up :)
@diyhvacguy
@diyhvacguy Год назад
I just saw your contribution. Thanks so much for your support!! Cheers man
@cahbee123
@cahbee123 11 месяцев назад
Nice install!
@yungsinatra3683
@yungsinatra3683 Год назад
Nice straight to the point
@guitarcrappy
@guitarcrappy 10 месяцев назад
I will be switching out my home heating/ac next spring. I have an old system, the ac is 1968 sears unit and furnace is probably a little newer but not much. The evaporator coil is in a huge box above the furnace that handles all of the outgoing ductwork. How do you handle a situation like that? Just change out the evaporator coil itself and not the box? I will definitely be signing up for the patreon a month or so before I make the purchase and start planning it out. Thanks for all of the great detailed videos.
@janicesmyth2183
@janicesmyth2183 Год назад
hi thank you for the great videos! My grandson who's in trade school loves these videos. He says it needs a filter drier. I have no idea what that is or where it goes. Looking forward to more videos!
@jredbokie1247
@jredbokie1247 11 месяцев назад
There is one inside the condenser
@VisionStance
@VisionStance 10 месяцев назад
Filter Drier not as necessary on a New System, although it would be safer for the evaporator coil in case of rust inhibitor breaking off of the compressor as what took place with a lot of Copland Compressors about 10 years ago. Also solder could affect the refrigerant circuit.
@jcw1197
@jcw1197 Год назад
That’s a cool drill attachment for cutting sheet metal. That would’ve helped me and my bro in law. We just replaced my furnace and AC last week and the sheet metal took a good chunk of time.
@diyhvacguy
@diyhvacguy Год назад
Yea it is a life saver! How did your replacement go??
@jcw1197
@jcw1197 Год назад
@@diyhvacguy it went well! My bro in law works in HVAC so that definitely helped. 😁
@diyhvacguy
@diyhvacguy Год назад
@@jcw1197 right on!
@glorianunez4923
@glorianunez4923 Год назад
​@@diyhvacguy Hola una pregunta . Es necesario tener permiso de un condado para remplazar e sistema de aire y calefaccion?
@Klarilove
@Klarilove Год назад
@@glorianunez4923depende de su cuidad. Normalmente se requiere un permiso
@franciscotejeda1461
@franciscotejeda1461 7 месяцев назад
Excelents videos n very educationals n have a good day
@norahsmith3320
@norahsmith3320 Год назад
Cutting sheet metal without gloves?!? I’m impressed!
@raindogs451
@raindogs451 Год назад
I've cut sheetmetal for 33 years without gloves, and don't know anyone who does.
@davidbrazell5179
@davidbrazell5179 Год назад
Im hear too watch and learn whatever i can about the trade. Seems like a great business to get into especially as hot as it is getting every year. Thanks for the vid
@philb707
@philb707 Год назад
Videos like this is why RU-vid was created. Plan on replacing my Lennox Pulse furnace with a Goodman. Definitely feel more comfortable after watching this.
@diyhvacguy
@diyhvacguy Год назад
Awesome! If you need any help with sizing or warranty with new equipment, feel free to shoot me an email at diyhvacguy@gmail.com Thanks, Dave
@jimyheffrey7336
@jimyheffrey7336 Год назад
How’d the install go?
@philb707
@philb707 Год назад
@jimyheffrey7336 didnt do it yet, money been tight lately. Haven't bought a new unit yet 😔
@jimyheffrey7336
@jimyheffrey7336 Год назад
@@philb707 feel that, everything hvac wise has gone up a shit ton
@joebashin1162
@joebashin1162 11 месяцев назад
Very ok, excellent show ❤ happy to watching
@Peepsteriffic
@Peepsteriffic Год назад
Do you ever add POE oil into the lines for HVAC replacement jobs like this with longer line-sets? If you have to add R410a into a system that has a longer line-set, it seems like you would need to add POE oil also. Thank you.
@NeoB-Lac
@NeoB-Lac Год назад
That’s some complicated ass work brother, 👏🏽
@eman-3
@eman-3 Год назад
Recently had a complete new set of two inside and outside units installed. Should I be able to feel cold air coming from around the top of the inside unit case (the door in your video with GOODMAN on it) and the place where the refrigerant line enters the unit? Thanks
@diymco2728
@diymco2728 Месяц назад
Awesome video! Respect! Question: I know it's different in every town but aren't there inspections required once completed (at least for the electric and natural gas)?
@latourbrian
@latourbrian Год назад
Loving your videos, thank you for sharing the professional knowledge. I've been doing DIY hvac to install my own heat pumps in AZ for many years. I always thought it was critical to isolate below 500 microns and monitor 10 or 15 mins of decay to make sure it does not rise too much. Do you not need this in any situation? Did you not do this because its a new unit?
@diyhvacguy
@diyhvacguy Год назад
I’ve recently started to implement this, but I hadn’t for a ton of units with no issues whatsoever. Just like I didn’t use nitrogen for alot of units with no problems years down the road. But yes this is definitely a good practice. I’m gonna be picking up the fieldpiece digital gauges this spring that have a built in vacrometer so you can do this decay test with ease. Cheers
@planetvance
@planetvance Год назад
Where's the charging the system with refrigerant part? Lame!
@unbreakablerick8358
@unbreakablerick8358 Год назад
@@planetvance i think most units now with 410a come with refrigerant inside the condenser, so no need but depends how long the lines are
@trucle1859
@trucle1859 Год назад
Thank you so much all of your videos. I just installed 3 tons goodman and it turned out perfect. I have a question though. Why did you need to convert piston to TXV. What’s the advantage and disadvantage? Thanks
@diyhvacguy
@diyhvacguy Год назад
I would have done a piston if it was up to me, but I quoted this customer a 16seer system, and the txv is needed to achieve 16 seer. The efficiency increase is minimal, not worth it in my opinion, but that’s what they wanted so that’s what we did. Txv’s are good, I just prefer the fixed orifice personally :) thanks for watching! If you have any other questions don’t hesitate to ask! Cheers
@jackmcconnaughey4630
@jackmcconnaughey4630 Год назад
Hey Dave love your videos ,would like to see a video about wheat pump install over existing gas furnace air cond. Coil housing above
@diyhvacguy
@diyhvacguy Год назад
I’ve been thinking about creating a video converting my condensing unit to a heat pump. That could very well be in the pipeline! Stay tuned
@Honestandtruth
@Honestandtruth 4 месяца назад
​@@diyhvacguy Why added a TXV....❓❓ Should it came with Evaporator coil
@MrBillsomm2000
@MrBillsomm2000 Год назад
Is the a big difference between a 14 seer and a 16.5 seer in regards to efficiency. How much should I expect to pay to have a pro install a furnace and ac?
@ronie1337
@ronie1337 Год назад
Thanks for the info.
@diyhvacguy
@diyhvacguy Год назад
You bet!
@muratozdemir6308
@muratozdemir6308 4 месяца назад
Great video! My ac unit is 20 years old need to replace I am thinking of getting Goodman GSZC 18 SEER any thoughts? Thanks
@mikemorgan5600
@mikemorgan5600 Год назад
Hello I love it my respect sir
@raulcarrillo3219
@raulcarrillo3219 5 месяцев назад
Dude you are good
@TeslaFan_007
@TeslaFan_007 11 месяцев назад
What black controller did you push down the hole and connect to the Google Nest E? I don't think it comes with Google Nest E.
@VisionStance
@VisionStance 10 месяцев назад
No Conduit on the High voltage Wire to the Condenser? Good Job, but I'd put 1/2" Conduit & Romex Connector on the High voltage wire going to the Condenser. Great Job on the Venting, very nice!
@Sirenity01
@Sirenity01 4 месяца назад
I just recently started school for hvac but a lot of the things were learning has me intimidated. Is it really that hard or am I just learning a whole bunch of things I most likely won’t even need
@tc0330
@tc0330 3 месяца назад
Great video. 7:47 was my favorite part.
@diyhvacguy
@diyhvacguy 3 месяца назад
🤣🤣🤣🤣 didn’t even notice that until just now
@joseherrera4227
@joseherrera4227 2 месяца назад
in order to open up the refrigerant lines, does the compressor need to be on?
@kexala2001
@kexala2001 Год назад
Love and tks
@ArnelleX-us9yo
@ArnelleX-us9yo 21 день назад
Nice Job.....Question for you....I have a Trane XR80 Gas Furnace...My house already has Duct System...What A/C unit is compatible with my existing Furnace?? Or would I need to upgrade??
@mrcleanofhvac
@mrcleanofhvac 3 месяца назад
This was fucken sick man thank you for this video 🎉🎉🎉
@knight1591
@knight1591 Месяц назад
good video:) why in some video do you install TVX ? some video not ? what is rules?
@Kevin-mm6xm
@Kevin-mm6xm 3 месяца назад
Why did you fold down the flanges on top of the furnace? Aren't they there to keep the matching coil case secured to the top of the furnace? I'm pretty sure when I did my Goodman 4 years ago that's how it went together and I definitely know I didn't fold anything down like that. Also, here's a tip. Start your screws on the bulb strap from the top next time. That will make it much easier to tighten. But actually, do not connect your steel TXV bulb to the aluminum on the evaporator coil. These are 2 very dissimilar metals and create galvanic corrosion between them. The TXV instructions show to connect it to copper either inside the coil casing or outside the coil casing, but you must connect to copper, not aluminum. Over time there's a good chance corrosion will develop on the aluminum coil due to steel on aluminum and a leak will occur. Steel to copper is way more compatible and should last the life of the unit.
@user-ei2mh7il2p
@user-ei2mh7il2p Год назад
why did you place the bulb before the TXV? I thought it needs to be after the meetering device?
@Verycrazychimken
@Verycrazychimken 3 месяца назад
I gonna put the same thermostat for my amana
@pml1807
@pml1807 Год назад
you make it look so easy sir ,thank you! How can I find an air conditioner size which have no name plates - sun fade out and no records? thank you!
@diyhvacguy
@diyhvacguy Год назад
You can look at the evaporator coil and it should have a model/serial on it. The Evap coil should match the condenser. If you are looking to replace the system though you can go in hvacdirect.com and look at their sizing chart and it will tell you what size system you need 👍🏽
@pml1807
@pml1807 Год назад
thank you sir you are the man
@VisionStance
@VisionStance 10 месяцев назад
Count the Return air ducts and their sizes, check the Breaker Size, the Square Feet of the house, check the size of the evaporator coil, look at the supply air capacity of the duct system, look at the top of the compressor and see if you can read the model number, Thats the best way.
@carltucker5254
@carltucker5254 Год назад
You didn't show the install of the fast-stat 5000. I like your channel you have tons of great information so thanks for that. I was also looking for a link for the 5000 I need this for my install.
@diyhvacguy
@diyhvacguy Год назад
The Easiest Way To Add A Wire | Google Nest / Ecobee Smart Thermostat C Wire ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-lHOmL65k_3U.html This one shows the add a wire not sure if that’s what you were looking for but thought it was worth a shot 👍🏼
@jakewesley6404
@jakewesley6404 Год назад
When brazing do you Ream sand and Flux your pipes? Also I'd love to see how you decide to do the through from the unit outside to the unit inside. Do you cut into siding or what? Also is nitrogen neccisary when brazing to prevent the pipe from getting too hot?
@clarencew8163
@clarencew8163 Год назад
Nitrogen is used to prevent carbon build up on the inside of the copper tubing from brazing.
@WinstonFlorent
@WinstonFlorent Год назад
Hello, very informative video I must say, however I wish you would show the process of recharging the system after you pull a vacuum.
@diyhvacguy
@diyhvacguy Год назад
Watch some of my other videos I show that process. But I’ll for sure be showing that part in greater detail soon! Cheers
@kurtwithaj6634
@kurtwithaj6634 Год назад
To be fair, that requires certification. You should know how to handle refrigerant very deadly.
@dankcount
@dankcount Год назад
@@kurtwithaj6634 lol no it’s not stfu
@xdolosolox511
@xdolosolox511 5 месяцев назад
Do you do any live training? Interested if so
@edkight6447
@edkight6447 Год назад
What's the theory of running nitrogen while braizing? I did residential appliance system work with just acetylene for 40 years so watching was a "what the heck ? " moment. All of those fittings on the evap. looks like potential leak sources. My 18 year old Rheem coil had nothing like that when I installed it. Nothing external on mine but refrigerant lines. Thanks for video.
@diyhvacguy
@diyhvacguy Год назад
Yea they wanted a higher efficiency system. I prefer the standard piston metering device instead of the txv that you saw on the Evap coil. The theory on the nitrogen is that if you braze without a nitrogen flow, it will creat soot inside the lines that will mix with the refrigerant. Supposedly it wasn’t a big deal with r22 but it is with 410a. That’s what they say. I have another video on Staybrite 8. An awesome alternative to brazing and no nitrogen flow is needed because soldering takes way less heat then brazing. Check it out! Cheers
@xavierrodriguez726
@xavierrodriguez726 10 месяцев назад
So much experience that he doesn’t cut he’s fingers with all the sharpest metals
@Bravo_L
@Bravo_L 3 месяца назад
I cut my fingers just looking at him handle the sheet metal lol
@yoyo7856
@yoyo7856 Год назад
Great videos first off! Do you ever check the gas inlet and manifold pressures or is the regulator always properly set from factory regardless of inlet pressures?
@diyhvacguy
@diyhvacguy Год назад
Yes, I always check that at startup
@planetvance
@planetvance Год назад
Where's the charging the system with refrigerant part? Lame!
@glorianunez4923
@glorianunez4923 Год назад
​@The DIY HVAC Guy In which City do you work? I need HVAC system replace.
@biggregg5
@biggregg5 Год назад
Quick questions.... In a central AC unit, I know you can braze, but I'm drawn to the pro-fit connectors even though they are pricey as a one off since they seem to be idiot proof. I've also seen compression fittings used....but the tool seems to run at least $1000. On mini-splits, flare fittings seem popular. Can you also do flare on conventional AC like Goodman? Also, soft solder...Staybrite 8 I think with minimal flux. Any thoughts. Brazing seems like it can be screwed up.
@diyhvacguy
@diyhvacguy Год назад
With anything other then brazing you are taking a risk, many people won’t do anything but brazing but I’m open to other alternatives. The zoomlock and rls fittings do require a tool that’s more like 3k which isn’t an option for most DIYers. They do have the push to connect fittings similar to shark bite fittings, most don’t trust them but I’ll install them on the next install I do and document everything! Another gentleman said that he only uses solder and flux and it doesn’t need nitrogen since it’s much lower heat. I’m going to look into that also and maybe give that a try sometime! Anyways thanks for the questions, it gives me something to try on the next install and if there is success then I can recommend it to diyers like yourself. Thanks for the support! Cheers
@biggregg5
@biggregg5 Год назад
@@diyhvacguy You're awesome! Thanks!
@diyhvacguy
@diyhvacguy Год назад
@@biggregg5 you got it!
@Tillyface89
@Tillyface89 Год назад
Staybrite #8 not plumbing solder I've seen used before.
@glockem1641
@glockem1641 Год назад
Brazing will consume you! Or it's just me. Kickin my xxxx in the 105° Texas heat. Chasing bubbles...
@LowellVanOs
@LowellVanOs Год назад
Great Video young man. Can you tell us the brand name of the unit you removed?
@VisionStance
@VisionStance 10 месяцев назад
Luxaire!
@mervyncorrales2876
@mervyncorrales2876 Год назад
What kind of wash in was that???? Easily can be moved or leak through that tape
@stanleykania7184
@stanleykania7184 Год назад
What do you say adverage per hour? $75-85 Seems fair where im at in western pa
@stevenst1
@stevenst1 Год назад
Hi, I have so much trouble running youtube on my ipad. I appreciate the responses to my hvac questions. I now know that my 1987 Tecumseh AV 168ET 005 Compressor runs but has stopped compressing the R22 freon. Do you have any ideas on how to replace or rebuild it? Thanks, Steve
@diyhvacguy
@diyhvacguy Год назад
It’s a pretty technical job. If your compressor is just locked up, it can be replaced by itself. If it had a burnout it might be better replacing the whole system. If you aren’t sure just google compressor burnout
@VisionStance
@VisionStance 10 месяцев назад
Give it up! that's like driving a Model T Ford on the German Autobahn.
@jessevasquez8323
@jessevasquez8323 4 месяца назад
Doesn't the manufacture recommend to insulate the sensing bulb.
@Bamacher59
@Bamacher59 Год назад
Hello great videos been watching a lot them can you solder them or do you have to braze and what is the difference
@diyhvacguy
@diyhvacguy Год назад
You actually can solder them but you must use Stay Brite 8. I’m in the process of creating a video on how to solder linesets and will be posting that before this spring when a lot of brazing will be happening. The Staybrite 8 has been field tested and is actually stronger then brazing, but requires the use of flux which some people don’t like. Brazing melts the copper together actually fuzing them, whereas soldering fills the joints. Stay tuned for the Staybrite 8 video! There are a few out there, but the guy Steven Lavamoniere here on RU-vid has been using it for 30 years and won’t use anything else.
@Bamacher59
@Bamacher59 Год назад
Thanks very informative Keep up the great videos and thanks again
@commando7707
@commando7707 Год назад
Why did you spray the brazing joint with water? Doesn't rapid cooling risk cracking the brazing joint? Would it be better to let it cool down slower?
@diyhvacguy
@diyhvacguy Год назад
I never had an issue with it but from what folks have said, it’s better to just keep the king valves cool and let the joint cool on its own. If you use Staybrite 8 it creates way less heat.
@Honestandtruth
@Honestandtruth 4 месяца назад
​@@diyhvacguyWHy added a TXV..❓❓. It should came factory installed
@lawrencedigiovanni9004
@lawrencedigiovanni9004 9 дней назад
​@@diyhvacguy Does the manufacturer approve the use of stay Brite 8 ?
@brandonslater2987
@brandonslater2987 7 месяцев назад
so why do you need nitrogen in the lines when brazing? And I'm guessing that using a methane torch wont work? Ans what metal are you melting? Is it different from water pipes?
@48bigmark48
@48bigmark48 11 месяцев назад
Like the video. One recommendation is when you put the bulb on it should be on the outside of the case. The installation manual says to. Also i dont know where your located but here in CO you gotta secure the coil box to the supply plenum.
@VisionStance
@VisionStance 10 месяцев назад
I agree, Metal with drive strips should have been used instead of that tape. It's not even Heat Tape. Won't last! Ive seen hundreds of tapped connections coming loose after time, always have to correct it.
@antman1206
@antman1206 Год назад
I have an EVAP coil on top of my furnace but have never had a/c. Why would that be and do I need to replace it with my furnace or just get rid of it? Thx
@diyhvacguy
@diyhvacguy Год назад
Alot of new construction they will put the evap coil on top of the furnaces and run the lineset, so if in the future it is desired, it is less work. However, if it is an old furnace with the coil attached, more then likely it is designed for r22, you can read what refrigerent it takes on the stamp on the front of the coil. So if it says r22, you will have the replace it with a new one anyways. I just recently did this for a customer. System had a coil from 2008, never used. And lineset and electric for condenser, but nothing was finished, so I installed a new condenser and replaced the evap coil with a 410a coil, connected my lines and electrical and it was in business! If you have any more questions, feel free to ask! Cheers
@VisionStance
@VisionStance 10 месяцев назад
Sounds like the Builder cut corners many places, probably went out of business. Cheap Cheap Cheap. Although I have seen that, it is usually on a basement system that is unfinished and required heat only.
@bheshamkumar2670
@bheshamkumar2670 8 месяцев назад
Hi , I m new in HVAC business , where do you buy furnace and AC
@trucle1859
@trucle1859 Год назад
Can I please ask you another question? I have a Lenox system about 6 years old that is still under warranty. The system is not getting cold at all. At first, I thought it was low on freon but I didn’t see any ice buildup on the system. I called the CO and they inspected it. They told me that the system needs freon which is not under warranty and I have to pay out of my pocket. I plan to charge the freon tomorrow. I just wanted to run by you to see why this system is low on freon but there is no ice buildup?
@diyhvacguy
@diyhvacguy Год назад
A system that is low on Freon will freeze the evaporator coil because the pressure at the low side gauge correlates to a temperature, when it gets too low, that temperature readout gets below 30 deg and the ice will eventually just block the air handler from blowing any air at all. You must have SOME temperature drop from your return air to your supply vents if it’s low on Freon but not freezing. It doesn’t necessarily have to be freezing to be low. Your pressures on a hot day should be around 150-170 on the low side and 300-315 on the high side. If it’s not super hot those numbers will be a little lower. Hope this helps!
@trucle1859
@trucle1859 Год назад
@@diyhvacguy So when I charge the freon, how do you determine that's full? is it based on the pressure range above that you recommended or based on SH & SC number? I looked at the factory sign. it's only shown the freon weight (5lb 13 oz).
@diyhvacguy
@diyhvacguy Год назад
@@trucle1859 Does it have a txv? If so you would measure the subcooling. If it has a piston, measure the superheat. Typically you want about 10-12 degrees of superheat, and around and the same for subcooling. If there is no heat coming out of the condensing unit like above the fan when you get started, and after you pump it up to around 150 low, 300 high and you get some hot air coming out, you know the condenser is working now. It should always be blowing warmer then ambient air out of the condenser. Email me for a quicker response tomorrow if you need help. Stojicrepair@gmail.com
@acmm50
@acmm50 Месяц назад
Whats the difference (pros & Cons) between a TXV vs Piston
@diyhvacguy
@diyhvacguy Месяц назад
Txv regulates up and down how much liquid to let into the evaporator. Piston lets a set amount of liquid through a tiny opening or orifice. Txv is more efficient and much quieter then a piston.
@NTSBxtter
@NTSBxtter Год назад
Why do you need nitrogen blowing in both the low side and high side as you braze.? Is it necessary .?
@KayfabeKingdom
@KayfabeKingdom Год назад
I was taught to braze first then blow nitrogen in both sides to see if there’s any leaks
@davidlangley6671
@davidlangley6671 Год назад
I started having problems with my furnace last year. Most recent thing they “think” it is is inducer motor. About $500 fix. House is 20 years old. I want to replace furnace. All a/c stuff was replaced 2 years ago w Goodman unit. Not sure what to do. I’m handy with home improvements but…. Btw. Hi efficiency furnace
@diyhvacguy
@diyhvacguy Год назад
As you can see, replacing the furnace is not something that’s crazy technical. If you feel confident doing it, I can help you find the right furnace for your house. They come pretty dialed in on the gas pressure. I haven’t had a single one that was way off on the gas pressure. $500 sounds reasonable for an inducer replacement if that’s the part and labor.
@diyhvacguy
@diyhvacguy Год назад
Thanks for reaching out by the way. If you’d like to email for a quicker response, my email is stojicrepair@gmail.com Cheers, Dave
@Verycrazychimken
@Verycrazychimken 3 месяца назад
I gonna do the same
@NickB1121
@NickB1121 Год назад
So what is the reasoning for using the vacuum pump after the nitrogen pressure test? If you're showing no loss of pressure after the nitrogen test, Im assuming its standard to test for outward pressure on the pipes, and the inward suction on the pipes as well?
@diyhvacguy
@diyhvacguy Год назад
No the vacuum is to remove any moisture and oxygen from the lines. Then when you introduce your refrigerant into the pipes, you are going from a vacuum to positive pressure. No air or moisture should ever enter those lines.
@VisionStance
@VisionStance 10 месяцев назад
There is no outward pressure on the refrigerant lines! You only pressurize the coil during leak search, but that practice has long been abandoned as no one removes coils anymore to find leaks and then reinstalls the same coil. too expensive
@onemoreboat
@onemoreboat Год назад
Is there any way to rent the tools rather than buy them like the vacuum pump, nitrogen bottle and evacuation pump? It's a lot of expense for a one time use.
@diyhvacguy
@diyhvacguy Год назад
Not really. They’re specialty tools but even if you were to buy the tools and resell them you’d be in it a lot cheaper then paying a company. You can also do everything up to the brazing and vacuum procedure and just have a small HVAC company do that last portion for relatively cheap and that way you don’t have to buy a vacuum pump, brazing tanks, nitrogen etc. etc.
@VisionStance
@VisionStance 10 месяцев назад
Your waisting time and money! You must have a License to handle refrigerant and know what the Hell your are doing. It's not easy unless you are a trained tech.
@nelsonquintero269
@nelsonquintero269 8 месяцев назад
So, is there any problem is you open the vapor line first and the liquid line second in your condensing unit?
@diyhvacguy
@diyhvacguy 8 месяцев назад
Doesn’t make any difference IMO
@diyhvacguy
@diyhvacguy 8 месяцев назад
I always do suction first
@MrInkotime
@MrInkotime Год назад
Why can't you use map gas to solder the joints? Also why do you need to have the nitrogen on to solder?
@MrInkotime
@MrInkotime Год назад
ok nevermind, just googled it. Need hotter flame than map, and then you dont want copper oxide, thats why we need the oxygen! You're doing a great job!
@diyhvacguy
@diyhvacguy Год назад
Actually I’m going to be testing a soft solder for hvac lines that’s called staybrite8. A lot of hvac guys swear by it and it only gets to 400 degrees so you don’t need the nitrogen flow. Will be doing some testing with that soon so stay tuned! Cheers
@MrInkotime
@MrInkotime Год назад
@@diyhvacguy Can you also do a video on how to capture freon from a unit? Like say a condensor has to be removed to install new concrete. Need to capture the freon and re-charge the unit.
@edmihovsky4404
@edmihovsky4404 7 месяцев назад
How much do you have to be able to lift to be an HVAC tech?
@MV-ep1ks
@MV-ep1ks 7 месяцев назад
What about the addition of coolant? Used to be freon?
@The1realro
@The1realro 5 месяцев назад
Most Condensers come pre charged with enough for a 15 ft line set
@tundrawhisperer4821
@tundrawhisperer4821 Год назад
For the outdoor unit, do you run a 10/2 or 10/3 with ground romex wire? Thx
@diyhvacguy
@diyhvacguy Год назад
10/2 👍🏼
@VisionStance
@VisionStance 10 месяцев назад
The size of the wire is determined by the amp draw or as the manufacturer says on the data plate. you might need 6-2 w/ Ground depending on the length and amp draw.
@tundrawhisperer4821
@tundrawhisperer4821 10 месяцев назад
@@VisionStance Just needed 10/2 and ran it 90’, system is up and working. A/C never felt so good! 😁👍🏻
@excellinc.9951
@excellinc.9951 Год назад
It is possible to do that with a propane torch ?
@diyhvacguy
@diyhvacguy Год назад
I’m going to be doing a few videos on using Staybrite 8 which is a solar solder made for hvac application and you will be able to use a mapp gas yellow small torch to do it. Stay tuned for that!!! Cheers
@rollawy
@rollawy Год назад
is it available in precharged and precharged lines...i don't want to mess with brazing or freon....
@diyhvacguy
@diyhvacguy Год назад
There are some mini splits that come with pre-charged winds, but not for regular residential split systems. You can always have a contractor come in and braise the joints and pull a vacuum on the system possibly. I did this for a customer not too long ago. He fitted everything and had it ready to go so I put my nitrogen flow on it braised it pulled a vacuum and tested out the system. it was a pretty easy process. If you have any more questions, don’t hesitate to ask. Cheers, Dave.
@rollawy
@rollawy Год назад
@@diyhvacguy thanks for the response...
@shreesiwa9311
@shreesiwa9311 Год назад
Where do we buy ac unit and heating unit. I mean which store or online. Can you give me the link and also which brand is best AC unit and furnace please
@diyhvacguy
@diyhvacguy Год назад
Hvacdirect.com Or Amazon.com
@diyhvacguy
@diyhvacguy Год назад
For a homeowner, I’d say Goodman. They have a good product. If you need help finding the right system, let me know and I can help you out. Shoot me an email at stojicrepair@gmail.com
@shreesiwa9311
@shreesiwa9311 Год назад
@@diyhvacguy Thank you so much. I hope you will make video how we will buy AC or furnace. Which brand is good, what is ton and seer. every things please
@codyrussell4844
@codyrussell4844 Год назад
Maybe a dumb question can you not use a map torch to braze?
@VisionStance
@VisionStance 10 месяцев назад
Need higher temperatures to braze effectively
@Bartman610nhmkfdsf
@Bartman610nhmkfdsf 7 месяцев назад
Why did you cut 1.5 inch off of the plenum to slide the coil? Now there’s a big gap between the coil and plenum and only securing it with metal tape. Sucks for the person that has to come back to replace the furnace only cuz that coil has a high chance of falling.
@lawrencedigiovanni9004
@lawrencedigiovanni9004 9 дней назад
Not the way to close up a large gap, medal table used for sealing joints not closing large gaps, not professional.
@Xavierpropertyshow
@Xavierpropertyshow 11 месяцев назад
Why does no one post putting the freon in the machine does it come with the machine?
@The1realro
@The1realro 5 месяцев назад
Yes it comes pre charged usually with enough for 15 ft line set. After installation charge should be checked and adjusted or line set length should be measured before releasing the charge. Then you can add refrigerant amount and then release the charge.
@bounnongkhoukone7234
@bounnongkhoukone7234 Год назад
👍👍👍👍
@Verycrazychimken
@Verycrazychimken 3 месяца назад
In my house I gonna install an amana
@Laoxxufiiccjjsdjcjcj
@Laoxxufiiccjjsdjcjcj Месяц назад
Buddys a hack fills gap with tape 😂
@jeffsworld2
@jeffsworld2 Год назад
I liked your video but I did not like how you filled in the gap between the duct and the top of the coil box with tape. Should have used sheet metal to fill in.
@diyhvacguy
@diyhvacguy Год назад
Yes this was when I was still learning. As you can see in my newer videos I build a nice transition with a cross break. But this does still work and will seal just fine. Thanks for the input! Cheers
@davidfrisch5538
@davidfrisch5538 Год назад
Just got a new goodman looks alot like this one .. when I started it up today for the 1st time , it smelled like something was burning and made the whole house smell .. Is that normal? .. I shut it off only let it run for about 1 min ... wondering if it's a new furnace thing ?!
@diyhvacguy
@diyhvacguy Год назад
Yep, perfectly normal. Sometimes the fire alarms will go off. Just monitor it, it should dissipate in a couple hours
@davidfrisch5538
@davidfrisch5538 Год назад
@@diyhvacguy okay cool that's good news .. I was wondering is there any package or something I missed that I needed to remove .. my plan was to leave the a coil as is an let a pro do that part in the spring .. I did notice just now you mentioned they ship with nitrogen .. I did not bleed that out yet .. should I or is that okay to just leave alone ? .. thanks for your time !
@diyhvacguy
@diyhvacguy Год назад
@@davidfrisch5538 they say to take the nitrogen out so I’d probably bleed it. I’ve seen them with nitrogen used before plenty of times. So if you put a new Evap coil there is a packet in there that has the manual and the brass elbow for the liquid line. you took that out right?
@davidfrisch5538
@davidfrisch5538 Год назад
@@diyhvacguy yeah I removed that stuff .. ill try it again tomorrow with the windows open and yet it run for a few hours , lucky its been warm the past couple of days so wanted to get the furnace portion taken care of .. ill bleed it the a coil too b4 .. I didn't see it in this video but your other ones you brushed on duct seal .. I think I should do that too .. right now the 1/2 in gap between the a- coil and Platinum is just foil taped with a few layers
@diyhvacguy
@diyhvacguy Год назад
@@davidfrisch5538 yea the duct sealant gives it a nice rigid surface that can’t tear.
@oneshot_onekill4618
@oneshot_onekill4618 Год назад
Do you have an email where i can ask a few questions regarding a goodman 2 ton GSX14?
@diyhvacguy
@diyhvacguy Год назад
Diyhvacguy@gmail.com 👍🏼
@ericvelasquez1282
@ericvelasquez1282 11 месяцев назад
Let the brazed joint cool down slowly
@KayfabeKingdom
@KayfabeKingdom Год назад
Did you remove the valve core before brazing?
@FortErieFireFighter
@FortErieFireFighter Год назад
I’m just curious as to why you didn’t get a custom return drop to fit the 16 x 25 1 filter
@VisionStance
@VisionStance 10 месяцев назад
I believe that was a 20 x 25 x 1 filter rack!
@cruzgonzalez5079
@cruzgonzalez5079 Год назад
Do you only use Goodman
@diyhvacguy
@diyhvacguy Год назад
Yes I am a Goodman dealer.
@ToyTubeReviews
@ToyTubeReviews Год назад
How much to install this
@diyhvacguy
@diyhvacguy Год назад
I believe this full install was about 7k for furnace and ac. But that was back when I was lot cheaper. Typically this system would cost 15k if you had a big company do it.
@ds1755
@ds1755 Год назад
Is the nitrogen really needed to perform the job?
@diyhvacguy
@diyhvacguy Год назад
No, it wasn’t used for many years but supposedly a unit will live longer if brazed with a nitrogen flow. I’ve installed many units without doing it and I’ve never had a problem.
@hitekrednek66
@hitekrednek66 Год назад
Gotta ask...your helper...is that home owner, spouse or hired hand?
@diyhvacguy
@diyhvacguy Год назад
That’s my better half 😅
@hitekrednek66
@hitekrednek66 Год назад
@@diyhvacguy that's very cool! She is not only a good helper but an attractive one at that! I think it is an awesome thing when couples can work together and find success. Yall keep up the good work!
@jerrynonofbss2588
@jerrynonofbss2588 10 месяцев назад
Did you run Hydrogen when brazing the pipes on the evaporator coil?
@PolarisBaBA
@PolarisBaBA Год назад
They don't show videos like this in schools?
@RamandeepSingh-ru3hi
@RamandeepSingh-ru3hi 17 дней назад
Hiii
@MattJonesYT
@MattJonesYT Год назад
Slight typo on description; "principals still apply" should probably be "principles still apply"
@diyhvacguy
@diyhvacguy Год назад
I’m on it! This is why I never won the spelling bee 😂
@freddiewiley1017
@freddiewiley1017 Год назад
Wow really??
@giozez4521
@giozez4521 Год назад
How much will cost for a 3 ton with furnace will cost i leave in California iam planning to replace mine
@diyhvacguy
@diyhvacguy Год назад
Hey! If you need help getting pricing, finding equipment, help with the install and warranty info, check out our Patreon membership at Patreon.com/diyhvacguy where for 25 bucks you will get one on one support and quick response times 👍🏼 cheers
@EP1CNELSON
@EP1CNELSON Год назад
In California it will cost between 8-13k for a standard efficiency furnace
@toddwhaley77
@toddwhaley77 Год назад
Vac gauge in line with pump 😂.
@diyhvacguy
@diyhvacguy Год назад
Yes I have made a lot of changes since doing this video, but this system is running great!
@toddwhaley77
@toddwhaley77 Год назад
Ok. Appion core tools, appion hose, pump, and a blue-vac micron gauge is all I use. Your video about sizing equipment properly. Are you doing manual j now?. I'm not sure how old that video was maybe you do it differently now but it kind of seemed like a copy paste, or leaning on square footage Do you have a HVAC contractor license, or handyman license?
@planetvance
@planetvance Год назад
Uh yeah. Where's the 410a to make it work? Lame!
@diyhvacguy
@diyhvacguy Год назад
It’s is precharged in the condenser 👍🏼 everyone asks this question
@planetvance
@planetvance Год назад
@@diyhvacguy I only meant lame in the sense that I really wanted to see you do that part. Great video. Sorry for my lame wording.
Далее
Аминка ❤️
00:16
Просмотров 595 тыс.
🌊🌊🌊
01:01
Просмотров 465 тыс.
🛑 до конца!
00:12
Просмотров 68 тыс.
Save THOUSANDS Replacing Your Gas Furnace Yourself.
54:49
How Air Conditioning Works
3:53
Просмотров 1,4 млн
How To Replace Your HVAC System From Start To Finish
45:15
Air Conditioning isn't free... but we're close.
25:45
"Flammable" Refrigerant Facts for Residential HVAC
1:02:01
How To Replace Your HVAC System And Save THOUSANDS.
31:14
Аминка ❤️
00:16
Просмотров 595 тыс.