The new #PowerWall 2.1 is now LIVE. I've connected the Pool Fence solar to the #Victron MPPT as the incoming energy source to the Victron Lynx 'Peter' Distributor.
On the other side of the Lynx Shunt, I have now connected the #Seplos battery to the Victron Power In. For now, I'm running the batteries in parallel with just one cable connected to the bus bars.
In the last step we connect the only MPPT and the battery to the Cerbo GX which is a true plug'n play task. Immediately, the system shows up on the Victron VRM. But, what do I have to see!? The Seplos BMS already slows down our charging?
Different SEPLOS batteries in parallel, Firmware upgrade, RS485 and CAN comms, DIP switches, Victron
• Different SEPLOS batte...
Victron Lynx System (great):
off-grid-garage.com/battery-a...
Double insulated Solar and Battery cables:
off-grid-garage.com/cables-an...
Tools, I'm using:
off-grid-garage.com/tools/
VE.Can to CAN-bus BMS cables manual:
www.victronenergy.com/live/ba...
VRM Live view Off-Grid Garage and S.P.A.T. Calibration Centre:
off-grid-garage.com/victron-c...
Please subscribe and join me on my journey of the Off-Grid Garage!
For more information, please check out my website with links to all the batteries, materials, devices and products I have used in my videos: off-grid-garage.com
The 'Buy me a Beer🍻'-link is here (on the website, scroll all the way down):
off-grid-garage.com Thank you for your support!
You can also click on the Thanks button under the video to support the channel. Thank you, if you have already!
T-Shirts, caps, mugs and more in our merch-shop:
off-grid-garage.com/merch
**** These are the batteries you are looking for ****
🔋➡EVE LF280/304 LiFePO4 cells 3.2V/280+304Ah: off-grid-garage.com/batteries/
🌞➡Solar charge Controllers, Inverters and accessories: off-grid-garage.com/solar-cha...
🔧➡Tools, Analysers and Testers: off-grid-garage.com/equipment/
📈➡ Battery Tests and Results: off-grid-garage.com/battery-d...
🔌➡Batteries, charger and accessories: off-grid-garage.com/batteries-3/
⚡➡Cables, Inverters and Electronics: off-grid-garage.com/electronics/
Get 5% off when buying Bluetti all-in-one Power Storage Products!
off-grid-garage.com/bluetti/
"Next Gen" AOLithium Batteries (4000 cycles, Bluetooth, CALB cells)
aolithium.com/?ref=offgridgarage
The Sunfunkit DIY battery. Great product to build your own 12V battery. Use OGGA at checkout to get 6% off. Video Review: • The Sun Fun Kit Experi...
New to AliExpress? Use my referral code below to register and earn US$19 store credit. What a great start! a.aliexpress.com/_mrtR9Ux
Take a live sneak peek at the Off-Grid-Garage in the Victron VRM World (link at top of the page):
off-grid-garage.com/victron-c...
My other RU-vid channels:
/ offgridgarageaustralia
Please don't leave any nasty words or links in your reply. RU-vid will not publish your comment in this case.
And no, I don't want you to contact me on Telegram. Look at the channel name, it's not even me!

Наука

Опубликовано:

 

3 янв 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 143   
@showme360
@showme360 Год назад
Looking good, going to access your system now, thanks for the link!!
@leo-nardfreg
@leo-nardfreg Год назад
Afternoon from st croix u s v.i looking good Andy..
@theokorner6237
@theokorner6237 Год назад
Hi Andy, your installations look really professional and cool. 🍻
@wayne8113
@wayne8113 Год назад
Thanks Andy, This Victron system really dose simplify a build, looks very neat and maintains full functionality. (Love it) 👍🐸
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
It is super easy and just works...
@gumpster6
@gumpster6 Год назад
More progress and you keep it tidy as always. Looking forward to seeing the charging issue being resolved.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Thanks. I'm afraid, there are a few more 'challenges'...
@glencooke494
@glencooke494 Год назад
It is obvious why the Victron solar charger is refusing to charge. It has gone on strike! due to the fact that it is not part of the big system, not on the same level and connected to a bunch of second hand panels leaning on a fence!!!!!! Keep up the great work Andy love you inquisitive nature.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Hahaha, didn't think about that. I'll give it some new panels soon...
@maverickmacgyver
@maverickmacgyver Год назад
Brilliant move building a UPS battery for the Cerbo GX, absolutely brilliant!
@beEnegy
@beEnegy Год назад
I am not 100% sure, but I remember that the DC source of the Cerbo GX must be the same as the DC source of a Multiplus.
@koffibanan3099
@koffibanan3099 Год назад
@@beEnegy I don't think so. I have installed a couple of Victron installations and two of them have the cerbo powered from the 230V grid through a 24V DIN power supply. Absolutely fine. I think Andy's solution is just fine, it'll take any DC input, the main thing to watch out for is when performing firmware upgrades; not getting into a loop. With a totally independent PS, you won't have any issues.
@lennieadi
@lennieadi Год назад
Great idea the ups for the cerbo. Keep up the great work Andy. 👊🏾
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Thanks 👍
@excillisbank2611
@excillisbank2611 Год назад
Belle évolution Andy's 😍
@UnkyjoesPlayhouse
@UnkyjoesPlayhouse Год назад
Pulled the trigger today on the EBC-A40L Battery Capacity Tester Charger today, so I can top balance these 8 cells I got the other day. Found a good deal on a unit. Now off to watch your video.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Oh, congrats. The 40L is my favourite tester.
@craigivas4037
@craigivas4037 Год назад
Looks great Andy. I would do what the last comment was as well make a little trolley with inflatable wheels so you can wheel it around your yard to plug mulchter and other things in. But any way it looks really good.
@evil17
@evil17 Год назад
Looks good, & I like ur UPS idea for the Cerbo GX.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Had the situation a few times with the big system and the Raspi went down with it. Very annoying...
@michao6495
@michao6495 Год назад
Very nice job! Regards from Poland 😊
@rajenwilliams
@rajenwilliams Год назад
Great video, as usual. 👍
@thk4711
@thk4711 Год назад
I think it is important to point out that one has to pay attention to the voltage rating of fuses. For instance most Mega fuses are rated up to 24V or even less. Inexperienced people might not be aware of that and just pick the far less expensive fuses from ebay or Aliexpress.
@Dutch_off_grid_homesteading
@Dutch_off_grid_homesteading 8 месяцев назад
Heya that looks very nice again well done
@grumpyjohntxredneckrc6346
@grumpyjohntxredneckrc6346 Год назад
You Could Also Mount The Inverter On Top Of The Batteries Packs To Free Up The Wall Space & Then Have A Roll Around Mobile Power Supply.. 🤔😜🤣😁😎
@chuxxsss
@chuxxsss Год назад
Morning from sunny hot Victoria. lol
@nigelcharles511
@nigelcharles511 Год назад
Sadly I didn't see the forum comment about the Cerbo problem and my Cerbo was one of the units affected. It failed just before Christmas after one year in service. I am now waiting for my retailer to respond. I hope Victron will provide a replacement FOC. Had they informed me directly beforehand I would have sorted out a reduced voltage PSU for the Cerbo.
@NIEPSEN
@NIEPSEN Год назад
Thanks Andy, I was waiting this one for a long time ! You are still the best youtuber for me, far away !!!
@clarencewiles963
@clarencewiles963 Год назад
End of class. Ready for our next session.
@mickm68
@mickm68 Год назад
Andy, On some of my installs i have used a bridge rectifier similar to jaycar ZR-1324. The ones i got off Ali were alloy encased but provided Jaycar reference as i can't provide comments with links to Ali. As a example of one install (note this only works with common ground). 12V Starter Battery (FLA) +ve fused and connected to AC leg 1. 24V House (LiFEO4) +ve fused and connected to AC leg 2. +ve out of bridge connected into Buck Converter to convert to 5v that is connected to RPi etc Using the above, both sources have fail before i loose mgmt power, and the house battery being higher than starter it is preferentially used.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
That's not a good solution. I need backup power to keep the Cerbo alive for 1-2h if the system goes down for whatever reason. And preferable a solution which is isolated..
@ahbushnell1
@ahbushnell1 Год назад
Data cables and power cables in the same duct is a no no. Nice video!
@onthelake9554
@onthelake9554 Год назад
Quality data cables have sufficient shielding . We do it all the time in automated machines .
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
No power cable, it's a DC cable and absolutely fine to combine with data cables.
@ahbushnell1
@ahbushnell1 Год назад
@@OffGridGarageAustralia DC power would not be run in duct with controls. Keep up the good work.
@jasonwilkerson7085
@jasonwilkerson7085 Год назад
What is your opinion regarding silicone wire? It has extremely high workinh temperature ranges.
@peterirvine5417
@peterirvine5417 Год назад
Great video again Andy, thank you. What is the digital torque meter you are using please
@patricklyons7683
@patricklyons7683 Год назад
You could also plug the smart shunt of the lynx into cerbo-gx, as a secondary measurement. I would swap the distribution & power in of lynx around. So the battery cable is not at max stretch just incase battery is knocked & moved.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
That won't work. You can nominate only one battery monitor in the system (which makes sense), so either the shunt or the BMS. The Power In always needs to stay left of the shunt and distributor on the right. Otherwise the current measured in the shunt is reversed.
@Ben32768
@Ben32768 Год назад
@@OffGridGarageAustralia I've a bed lvl battery and a lynx shunt in parallel It just works But you must decide which BMS is used for the control loop
@camielkotte
@camielkotte Год назад
Nice. Thx again Although a battery in wheels connected to the wall with high power.... What can possibly go wrong?
@xavier5262
@xavier5262 Год назад
Thankx Andy for all your information and insparation, please keep up the videos , they inspire me in the design of my apartment balkon solar with Victron multiplus II design , if you are intrested I can send fotos when I'm finiched the Ikea Pax closet solution. If you need somting from Victron I'm close to the factory. Best regards Rodney Aardse from The Netherlands..
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Thanks a lot for your support! It's, please, send some photos when your finished. IKEA and Victron, two of my favourite companies☺️
@PierredeVilliersLife
@PierredeVilliersLife Год назад
Hi Andy Why do you not turn of the Seplos BMS when making the connection? I believe the Seplos BMS have built in pre charge circuit when switching on the BMS
@danmfeist
@danmfeist Год назад
Do you plan to add a class T fuse (or a noark breaker?) prior to the power-in? The ANL fuse in the lynx shunt module is quite far from the battery to provide short protection. Or are you happy that the 400A fuse in the battery enclosure is fast enough and got high enough interrupt current to suffice for this purpose?
@roadeycarl
@roadeycarl Год назад
I had the a similar issue. It turned out to be the BMS was stuck in Pre-charge mode even after 10% SOC... even after a BMS reset and set to default settings the issue occurred. Seplos sent me a new config file which I uploaded onto the BMS which fixed the issue although I'm convinced it'll happen again.
@jasonwilkerson7085
@jasonwilkerson7085 Год назад
Off subject... I struggle with knowing what breakers to use from battery to Inverter/ loads. I want the ability to turn off the power but also have some protection all in one. So much yo choose from out there and not enough education to know what is ok and what is not and why... I'm working with 12v in a RV. If you have any suggestions where I can learn this or maybe make a video :)
@SeanMoore2008
@SeanMoore2008 Год назад
I suspect your 150/30 will start derating due to temperature, you might want to move the inverter or fit a heat deflector.
@centerrightproudamerican5727
I like to keep the fuses on the battery closer to the batteries. It's too late now, but perhaps the Distributer-Shunt-Peter should have been mounted on the bottom of the wall.
@ShaneFromSA
@ShaneFromSA Год назад
The BMS and circuit breaker are basically those fuses. You don't actually need fuses on the Power In Distributor, hence why they don't come with them.
@bobbinbob
@bobbinbob Год назад
Bear in mind the BMS itself have ANL fuses inside them also, so this is fine 👍
@Ben32768
@Ben32768 Год назад
Hey Andy Where did you get these mega fuses? Are they rated for the 48V battery voltage Normally these generic ones are only suitable for 32V or less.
@d3claes
@d3claes Год назад
yes, for a 48V system, there are megafuses that are rated 58V. They are (much) more expensive!
@onthelake9554
@onthelake9554 Год назад
Victron
@Ben32768
@Ben32768 Год назад
@@onthelake9554 I bought mine from victron they look completely different, that's why I asked
@onthelake9554
@onthelake9554 Год назад
@@Ben32768 Oh sorry , he may have got them somewhere else , I just assumed they were Victron .
@jimmyg6215
@jimmyg6215 Год назад
Yea I would like to know as well. The 58v seem ridiculously expensive vs the 32v versions.
@giorgos1975m
@giorgos1975m 5 месяцев назад
Hello i wonder if on the victron bus bar connecr second set of cables with another battery (eg. Your big set ) will it be able to control it with the cervo too or not ?
@kevinouterbridge3300
@kevinouterbridge3300 8 месяцев назад
Good afternoon thanks for the information but I have a few questions I need to know were do I get the cable 🦆 tray the wire are nice and neet I like to get the link please if you can help me in the video power wall 1 and 2
@DanBurgaud
@DanBurgaud Год назад
0:18 . . .hmmm.. 😒not fond where it is right now... hope you can get a nice place for it.
@manuelel1964
@manuelel1964 Год назад
Hi Andy, I'm planning the system with integrated Victron and Seplos battery packs, but I wondered about this. What is the point of placing the Victron shunt in the system when we already have a Shunt on the Seplos BMS board? If so, which would be the priority? We can do without the Victron shunt, what would we miss? Thanks for your kind reply.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Exaclty. That's what I explained int he video. You need either or. I've left the shunt in the system as we may not use the Seplos BMS communication nightmare for too long. I'm still working on that though...
@cyberplebs6577
@cyberplebs6577 Год назад
🐸🐸🐸
@Wolfihouse
@Wolfihouse Год назад
Greetings from the Czech Republic! My Cerbo GX is from a series that has a 48V power supply, so it is connected to the Lynx Power bus from the beginning. I use Pylontech US2000C batteries and everything runs perfectly. I'm keeping my fingers crossed for reviving the combined BMS batteries, I hope you can get it going. I wish you good health and inspiration until 2023. Thanks for your videos..small question please: From which manufacturer do you use those orange DC cables between MPPTs, batteries, etc. I couldn't read it in your videos...
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Thanks a lot for sharing and your kind words, Jan. I get my cables from a local company but have links to similar cables on my website from AliExpress and Amazon.
@theshepard22
@theshepard22 Год назад
Quick question I've been pondering guys- If I'm using a Renogy DC to DC charger between my lifepo4 battery and my vehicle's battery - would I need to have the "on" switch connected to the relay area or is it enough to use the switch that is already connected in my vehicle which controls the power from the van battery to the pos and neg that are going back to the cargo area? (It had an isolator setup to an auxiliary battery when I bought the vehicle, controllable through this switch to charge through the alternator power.) Thanks much! I know you guys love the batteries and solar setups! Much appreciated
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
The switch is fine. It's just a manual option rather than the relay which would be automatic when your start the vehicle.
@PeterMilanovski
@PeterMilanovski Год назад
We have the same inverter, my son got an AC shunt for the AC output which plugs into the raspberry pi and now shows the AC usage on the victron app.... I'm not sure where he got the AC shunt from but I think that it's on the victron website.... It would be great to connect the inverter to the raspberry pi via the remote switch connector on the inverter to be able to remotely turn on or off the inverter as needed, not sure if a relay would be needed or the raspberry pi could directly do the switching? Someone with more experience with the raspberry pi would know better than me, I'm not sure what voltage or current would be at the remote switch for the inverter either..... But the AC shunt is well worth it... I highly recommend it.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
It's an AC energy meter connected via Modbus to the Cerbo. It can measure the output of non-Victron inverters.
@dc1544
@dc1544 Год назад
have you seen those dc fuses catch fire when you cutoff power from solar when 10 amps are going through them. They now use disconnect solar switches as that fuse will do nothing but cause a fire. I seen 2 videos showing that and they are made by Australians. The disconnects have a greater distance so the arc is not able to keep firing like with that PV breaker you have. Just want you to not burn down your garage/house etc.
@adamrucker3268
@adamrucker3268 Год назад
Andy, would you share your setting on the bms? i have 3 of them. Would help make sense of the terms they use. i have 280ah, 310ah, and a custom build 450ah
@onthelake9554
@onthelake9554 Год назад
I think he already made that video .
@pettorinpettorin3249
@pettorinpettorin3249 Год назад
Ciao Andy, I have same problem with my primary Cerbo GX + Inverter RS Solar + SOK 48v100 and Secondary Muliplus II GX + MPPT250/100 MC4 =SOK 48v100, when battery is connected MPPT is charging at 52.4V in both systems. I start to think that might be affected due to the Pylontec protocol typically working on 15 cells rather than 16 of the common 48v battery....
@tiborchren
@tiborchren Год назад
Hi, great video of you using the exact same Victron components I’m thinking about for a smaller solar system, thank you. I can't wait for the next video. For me the Victron Multiplus or Phoenix inverters 48V/5000va are so expensive. Also, you will be using a Non-Victron inverter and you won't have load data in the system. I was thinking if in this case it would be possible to connect a Victron Energy meter ET112 behind the Non-Victron inverter, which can be connected to the Victron Cergo GX and deliver load data to the system that way even when using the Non-Victron inverter. What do you think about this?
@ShaneFromSA
@ShaneFromSA Год назад
If you are going to spend the money for ET112 you might as well just get a Victron inverter. Which will give you that load data and remote control. And Victron reliability and low stand by power consumption.
@cskeise
@cskeise Год назад
💙🙏😎
@slackytom
@slackytom Год назад
Hi Andy I saw that when the seplos BMS comes into balancing mode a led comes on in a previous video. Would you be able to use circuit to turn on the active balancer?
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Which LED would that be? I haven't noticed one...
@slackytom
@slackytom Год назад
@Off-Grid Garage Hi can't find the video now. from looking again at the front of the battery and what I remember it may have been the red alarm led. Does this come on at high and low cell voltage?
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
@@slackytom Yeah, right. That was definitely the alarm LED because at least one cell was over 3.5V. Interesting thinking using that to trigger an active balancer... On the other hand, it would also do it, if one cell is low and you definitely don't want that...
@anthonyrstrawbridge
@anthonyrstrawbridge Год назад
Is solar reflective greenhouse paint good on PV panels? I like the idea of being able to spray it on with the hose.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Yeah, good luck 😂
@anthonyrstrawbridge
@anthonyrstrawbridge Год назад
@@OffGridGarageAustralia Yes, thank you. My initial plan of resorting to consuming copious heaps of sugary drinks and foods has not worked.😪
@niktak1114
@niktak1114 Год назад
Hopefully all the issues are figured out before I setup communication with my 280Ah mason kits when the remaining 3 arrive (4 total).
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
I'm afraid there is more...
@davidb.5544
@davidb.5544 Год назад
This is why I don't like the idea of a BMS controlling my system or at least a BMS from a company that I don't have faith in has fully tested all scenarios.
@onthelake9554
@onthelake9554 Год назад
Exactly , If Victron would make us a 16s bms with comms and all their adjustability , it would sell like hot cakes .
@hmarc417
@hmarc417 Год назад
And now that you have installed a 12volt system for the Cerbo, you now have power for pc fans and put your air con somewhere else, like in the house. I knew at some point that you would have to have 12v somehow in the system. Just a hunch.
@Full-of-Starships
@Full-of-Starships Год назад
I think that battery v2 really needs fan cooling (one fan on intake per shelf behind the BMSs), and it already has an internal 12v DC-DC converter. Problem today is that it seals in any hot air.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
The dust, guys, the dust... and insects... The battery shelf is fully sealed. We had this discussion when I built it.
@pete4778
@pete4778 8 месяцев назад
On the Victron shunt you’re using a 300 fuse so depending on the battery size my is 675 AH must be fused according.
@OffGridGarageAustralia
@OffGridGarageAustralia 8 месяцев назад
It depends on your cable size primarily.
@vfast007
@vfast007 Год назад
Mega fuses seem to have voltage ratings and Victron are the only 48v ones I can find in Aus. Have you ever tested them? What brand are you using here?
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
I have cheap ones from eBay for this test setup. I considered a piece of busbar for the ANL fuse in the shunt but was afraid of all the comments... 😁
@vfast007
@vfast007 Год назад
@@OffGridGarageAustralia ha! I assume the higher voltage ones (of which only Victron seem to provide) are able to break ark. I believe T class the best but they are so expensive.
@gavinnoname1424
@gavinnoname1424 Год назад
Does anyone have any ideas on how to dual power supply the Cerbo? (Or RaspberryPi) Would be good to have it powered from Grid and Battery for redundancy
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Soon on the channel here...
@janetmorris6792
@janetmorris6792 Год назад
It would be nice to have a couple of Fixed digital meter's fixed on the back wall by your Blue boxes and make it look more like a power station without having to use the mobile phone all the time or better still a fixed tablet on the wall to display all the info
@ShaneFromSA
@ShaneFromSA Год назад
You can just get the Victron Touch 50 display for the Cerbo
@Irilia_neko
@Irilia_neko Год назад
I have an indigestion of seplos
@stevenfeavearyear7567
@stevenfeavearyear7567 Год назад
Slightly off topic but victron based, What are your thoughts on the Easy Solar integrated boxes? Seems the only thing you would need to add if using it in say a motorhome/caravan would be a shunt monitor. Would there be much point in going for one with a Colour Controller?
@Lulastyle
@Lulastyle Год назад
Hi Andy, greetings from your Italian fan, a curiosity, I only find 32v Anl fuses, are they good on a 48v system? What fuse did you buy? thank you
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Victron has 80V ANL fuses : www.victronenergy.com/upload/documents/Datasheet-Midi,-Mega-and-ANL-fuses,-and-fuse-holders-EN.pdf
@dennisbrok9335
@dennisbrok9335 Год назад
You put the nut upside down on it has a flat side and a side with rounded edges rounded edges should be upwards
@beEnegy
@beEnegy Год назад
Servus Andy, today I also write a comment. You have installed an ANL fuse in the shunt, a CNN fuse belongs in there. Can you possibly measure the resistance of the two fuses that you have installed? I would like to compare it with the original CNN and MEGA fuses. Greetings from Öttingerheimat.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Victron sells 80V ANL fuses for this device. CNN or CNL are an option too.
@paulcurtis5496
@paulcurtis5496 Год назад
Like# 524???
@Mr1Spring
@Mr1Spring Год назад
Andy, I have a similar issue. Using a Raspi with louisvdw/dbus-serialbattery plugin. There is a hard limit in his driver. Look at his github installation page. Max voltage 3.45V/cell. Perhaps Victron did somthing similar? Post a message at the Victron community. Perhaps someone will know what's going on.
@tx75e94
@tx75e94 Год назад
My Seplos BMS give the CVL to 55,5V to my cerbo gx and it set that on my multiplus, giving me 3,46875 cell voltage. In the 2.8FW I can't control this voltage but in 2.7 I could. So could be down to the programming in the BMS.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
I don't use the driver on the Cerbo. It works without it... I know about the limit but you can modify the file and increase the limit. 3.45V is perfect by the way 😉
@johnsteamer828
@johnsteamer828 Год назад
Hi old mate can you give me the brand and name of the three Isolators you use in battery 2.0 John
@koffibanan3099
@koffibanan3099 Год назад
Blue sea systems switches? The red ones?
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
These? off-grid-garage.com/battery-accessories/
@edwardvanhazendonk
@edwardvanhazendonk Год назад
I think you could replace the Seplos BMSes with JK's for ease of mind.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
But how do they communicate to the Victron system then? This is the main problem of the battery shelf: if one BMS is turning off the MPPTs keep pumping power into the remaining batteries. Communication should tell the MPPTs to slow down before it is too late and all BMS have shut down.
@edwardvanhazendonk
@edwardvanhazendonk Год назад
@@OffGridGarageAustralia I need to think about this as well. Maybe the Node Red Victron addition can tell the charge controllers to slow down. Based on either reaching max voltage or from what the BMS will use. I still am not ready myself with my setup, still working on battery enclosures etc.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
@@edwardvanhazendonk I'll cover this again in a video soon. Lots to think about and to discuss.
@4GoChris
@4GoChris Год назад
First🎉😊
@GapRecordingsNamibia
@GapRecordingsNamibia Год назад
I have a feeling that DVCC may have some influence on your charging problem, I have a sneaky feeling, I had to disable DVCC on my system, it was messing around with my setup.... Well see though.
@ShaneFromSA
@ShaneFromSA Год назад
What was your problem? DVCC should not be disabled if you have BMS coms.
@GapRecordingsNamibia
@GapRecordingsNamibia Год назад
@@ShaneFromSA DVCC was causing major charging problems with my BMS's, it was limiting current and as in Andy's case and it was messing with my top end voltages in batteries. I disabled it and just set my MPPT logic to follow set charge curves and have been running for 4 months flat and zero issues. DVCC does NOT play nicely with all BMS's, software or firmware wise that is. Understandably though, and in all fairness to Victron, whom I have quite a few products of, the DVCC logic was developed to run on their systems, they can't (and should not) have to guarantee 100% operation or interface with other manufacturers BMS's it should be the other way around. That being said though, once DVCC was disabled Bob was running 100%.
@deepu083
@deepu083 Год назад
hello Sir, Please check the DVCC Setting , please disable Share Voltage Sense and temp. and check it
@deepu083
@deepu083 Год назад
Go Setting then DVCC then SVS, STS , SCS disable then try
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Why should I disable that? Just checked, only SVS is active...
@zxrjimmy1
@zxrjimmy1 Год назад
Are those 58v or 70v mega Fuses
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
24V, I believe. Maybe 36V.
@zxrjimmy1
@zxrjimmy1 Год назад
@@OffGridGarageAustralia will they do in a 48v system if fuse is 32v
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
@@zxrjimmy1 it's just for my test setup. For a real system, I would get the correct voltage rating fuses.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
@@zxrjimmy1 Yes, they will work.
@Sanwizard1
@Sanwizard1 Год назад
I am not a big proponent of daisy chain batteries. Make them all parallel.
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
I will as I said in the video 😉
@nn858121q
@nn858121q Год назад
300 A istn it too much, Ándy?
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
Too much for what. It's a 1000A busbar it protects, so it should be right.
@onthelake9554
@onthelake9554 Год назад
SEPLOS sounds like a virus I don't want to catch . How come no comms on Lynx shunt ?
@OffGridGarageAustralia
@OffGridGarageAustralia Год назад
We don't need the Lynx shunt when using batteries with a Smart BMS.
@onthelake9554
@onthelake9554 Год назад
@@OffGridGarageAustralia Yeah that's what I thought you were up to , but can you still have it on the vrm for a reference of soc if you don't trust the bms without causing a problem?
@offgridwithpojectham
@offgridwithpojectham Год назад
Seplos! 🤦‍♂
@vickipps6821
@vickipps6821 Год назад
Hello Andy how do I get hold of you PM you what's up or Telegram thanks
@evil17
@evil17 Год назад
It’s a SCAM, Andy is not on TELEGRAM.
Далее
IT'S FINALLY DONE! | DIY Massive Off-Grid Power System
27:21
Custom VICTRON
15:19
Просмотров 61 тыс.
Sodium Ion Battery Vs Lithium Iron Phosphate Battery
7:08
Solar Panel Wiring vs Volts and Amps
10:19
Просмотров 360 тыс.
iPhone socket cleaning #Fixit
0:30
Просмотров 17 млн