Тёмный

Other Remedy sa LOW VOLTAGE SUPPLY ng DISTRIBUTION UTILITY! 

Sola Renz
Подписаться 54 тыс.
Просмотров 5 тыс.
50% 1

Remedy sa LOW VOLTAGE SUPPLY ng DISTRIBUTION UTILITY!

Хобби

Опубликовано:

 

5 апр 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 23   
@severinodamra
@severinodamra 3 месяца назад
Kahit na di na siguro e tap sa gen port si grid sir bwasan pang lvd ni deye pra di mag totally black out kung sakali ma lowbat. Dagdag bill lang yung grid charge..
@jemeldelacruz6435
@jemeldelacruz6435 2 месяца назад
Sir my video ka ba Ng paglatag at pageiring Ng panel to inverter
@kennyjamesdenila4306
@kennyjamesdenila4306 2 месяца назад
Sir ano pa difference ng lifepo4 bateeries na deepcycle, powerwall and stackable. Sana mgawan nyo ng video. 😍
@user-yy5hh2cz1v
@user-yy5hh2cz1v Месяц назад
sir Renz pag 180v bolts po Ang batelek pwede po Kya sya sa grid tie deye 10kw? salamat
@markarca6360
@markarca6360 2 месяца назад
So ibig sabihin nito po, kung meron po akong 3000w na inverter at 25.6 V ang nominal at ang amperage ay 117.1 A, ibig po nitong sabihin ay pwede po ang 100A hanggang 125A na MCCB?
@teamtulungan2023
@teamtulungan2023 2 месяца назад
Sir tanong lang pwede bang i series connection dalawang higee 120ah?
@dockievlog
@dockievlog 25 дней назад
Sir idol paano yun settings sa low voltage kapag na ipasok yun low voltage ng grid sa deye gen port sana magawa po yan ng video or pwede paturo sir idol salamat.
@livingoffgridinthecity5546
@livingoffgridinthecity5546 3 месяца назад
sir magandang umaga... ok ang setup mo... ung diskarte pede na... i believe na sa gridtied eh need ng 3 element para mag sync 1.phase 2.voltage 3.frequency so sa tatlo prang problema mo ay voltage (obvious naman :) ) ung kinabitan mong lugar ay single phase na malayo sa transpormer or wlang transpormer, then ung sa genset, n diskarte same lang ng du ang sycn process so useless pa din good thing at may ats ka.. pag naubos ang load ng client matic na sa du... dapat ay nag pre inspection ka bgo nag install
@livingoffgridinthecity5546
@livingoffgridinthecity5546 3 месяца назад
opps teka reply sa sarili kesa edit... sorry di ko npanood ng buo sa una.. ats bakit may ats pla, so kung hybrid na system my setting yan na pra mag set sa du, offgrid or sabay...hmmm binasa ko n rin ung specs ng inverter mo sir w/c is available ang option ng auto switching and ung sa genset pala line 1 and 2 is 110v preho... kindly explain sir bakit may ats at ginamit mo ang genset line???
@tyjonesd
@tyjonesd 25 дней назад
@@livingoffgridinthecity5546 pag hybrid, pang isolation ang ATS para gumana ang backup battery automatically. kasi ang normal ng ATS sa grid talaga. so nilipat niya sa Generator port ang grid para maging stand by na lang siya, at solar+battery ang magiging main supply for stable voltage.
@franssantos9417
@franssantos9417 3 месяца назад
Sir, is it right to conclude that to remedy the low ac grid voltage prevent causing problems, what you did is connect the intermittent low ac grid voltage to the Deye - generator input port? Such method then could still re-charge the battery from the grid (even if it's sometimes lower than 220v), but the house will totally rely on the battery for the stable 220 volts ac electricity? I hope my understanding is right and many thanks for your highly valuable information.
@robertdatario85
@robertdatario85 2 месяца назад
This is my understanding too. I'm having a hard time following the connection of the Gen to where it's connected.
@lolonglomocso5753
@lolonglomocso5753 3 месяца назад
Hi Sir Renz. How much this 8kw solar installation cost your client?
@solarenz
@solarenz 3 месяца назад
460
@kokikz05
@kokikz05 2 месяца назад
Sir, pede gawa rin kayo video ng set-up para sa pull-start/manual start generator connected sa GEN port (possible po ba un sa gen port kapag pull-start?). or pede sya connect sa grid port with ATS (generator as back-up?. salamat po. gusto ko pa rin kasi gamtin ung generator lalo kapag matagal ung brownout kapag may bagyo dito sa probinsya
@solarenz
@solarenz 2 месяца назад
Pwede
@kokikz05
@kokikz05 2 месяца назад
@@solarenz salamat sir, may nakikita kasi ko sa GEN port setting (GEN connect to Grid input)
@stevevarberg8005
@stevevarberg8005 3 месяца назад
Hi Renz, how will your systems survive overnight if the battery gets too low? Will it charge off of the grid and keep on running? I once had an idea I was wondering if you feel this is a practical solution that would be: to rectify the grid power to DC and install a charge controller to constantly be charging the batteries off of the grid. Since the system will not be affected by the low-voltage fluctuations of the grid.
@solarenz
@solarenz 3 месяца назад
If the battery gets low, and reaches the cur off voltage, the Automatic transfer switch (ATS)will change over to DU, afterwhich, the gen port will pass through the DU line to have the static charging, and maintain the low voltage but not giving out AC output until the next morning and the solar panel could be able to strongly charge the battery and regain voltage of 52V, that’s the time that the power from solar will take place, thus ATS will go back to normal side. I hope you have understood what I meant .
@solarenz
@solarenz 3 месяца назад
From what country are you?
@VanjoeArreglo
@VanjoeArreglo Месяц назад
good day sir,,pwede po ba 24v ang system v 3kwhybrid offgrid inverter at dalawang 540wtt solar panel,gumagana ba ang inveter?salamat
@jericolopez7452
@jericolopez7452 3 месяца назад
posible pag gumamit ng AVR sa grid..?
@livingoffgridinthecity5546
@livingoffgridinthecity5546 3 месяца назад
mlking avr yan sir lmao