Good job Noy! LonBicool, together with your team...however, based sa aking sad experience, ok naman lahat ang water lines/plumbing installations na ginawa ng contractor, until such time/more or less ten years, ay nagsimulang mag-leaks o bumigay na siguro ang mga joints/connectors underground/concretes. Therefore, wala akong choice but to have the waterlines be exposed of which, syempre...naging panget na sa paningin. Also, that was the common causes rin dito sa mga rental apartments sa Saudi, not all, but several buildings have suffered of sudden flood damages due to busted water lines/pipes/plumbing joints/connector. Moral lessons, unless otherwise you will use a PP-R is “Polypropylene-Random” in short. Polypropylene (PP) is a type of polyolefin plastics plumbing kind of products... eto yong walang putol ang pipe at ang connectors ay heated to be able to joint/connect without using any adhesives where perhaps the main culprits of the leaks. Note, medyo pricey nga lang pero sa palagay ko dito ay mey Forever na walang sakit ng ulo. Peace.
Tama k po kabayan mas matibay po ang PPR Gumagamit po kme nyan kabayan. Sa mga ibang project. Dumidepende ren po sa nag papagawa kabayan. Sa kaya ng budget. Samalat po kabayan
Marunong ka talaga pumili ng gamit mo Manoy top of the line ang napansin ko mula sa iba mong vlog. Pero dapat nagpressure hindi mo pa natakpan lahat o na semento. Ksi once nagleak di mo alam kung saan at bakbak ka nman. Pero full confidence ka nman sa installation mo cgurado din lahat. Sa ibang kontratista hindi nila ginagawa yn. Talagang pulido ka gumamawa at organized. Keep up the good work. GOD BLESS.
bro plumbing contractor ako sa ibang bansa pero di ganyan ako mag check ng pressure simple lang at do mo ma check ang underslab cementado na kung may leak dapat ginawa mo yan nun di pa naka concrete
11:46 SALAMAT sa sagot sa aking katanungan, dapat bago buhusan ng semento nag pressure test muna para kung may leak ay magawan agad ng solusyon, 'yun naman pala ang sitwasyon kaya nahuli ang pressure/leak test
Tama mas sure ball pag ppr pipes. Mas matibay ang ppr. Lumulutong ang pvc kalaunan. Di na kailangan solvent. Yan kasi Ang weak points ng pvc compared sa ppr na fusion,mas sulit.
Ang gagawin mo kabayan hahatiin mo sa dalawang parte ung water line Kaya dapat alam mo kng san dumaan ang tubo para madali lng sinsilin. Tas chk mo ung isang parte. Sa dalawang parte n yun ung isa dun makikita muna kng nasaan ang may tagas. Tas ung isang parte n may tagas hahatiin mo nanaman ganon po kahirap. Kaya dapat lage pasiguro. Mensan natatamaan ng pako ng mga pason pag mababaw pero madali mahanap ung mga ganun kc mag tutubig. Ang mahirap ung nasa ilalim ng flring.
Mr Edwkev 🤬They practice the pressure leak chk prior and after the concrete application problema nga daw nag covid lock down at alang mabilhan ng tools...kundi sa manila lang.. Buti nga ginawa ni bosing at alam.. tanungin mo lahat ang isang daan na tubero alang pang chk..🤪🤪🤪😂😂
I absolutely agree!!! it is a must prior done concreting. However, like my personal experience kahit pasado at OK-ok ang pressure tests... sa munting pinag-ipunang bahay, it took several years bago nagbigayan ang mga joints/pinag-couplingan o dugtungan ng PVC pipes in an underground. I hope this won't happen to anyone na magpapagawa pa lang now or sooner... avoid these mistakes, dahil wala tayong pwedeng pag-charge-dyan ng sablay... but to Experience :) Peace mga kabayan's
Pano pang tester sa main pipe line kung may existing water ba or wala.... Pano malalaman sa loob ng pipe line kung may tumatakbong water with in subdivision po....
Hindi ko alam na meron akong kailangang bilhin, mag-kano naman Sir ang ganitong equipment ? Salamat Sir , ngayon may idea na ako kung papa-ano mag-leak test.
Normally ang ginagawa ko kapag mag leaktest/pressure test, dapat before magbuhos, plaster at backfill para kung me leak, madali lang mahanap at marepair.
Ah ganyan pl mag check NG pressure manoy sain k sa bicol pade ako sa sorsogon but ofw electrician ako dito sa Qatar nowp shout out namn at pa dikit ha ha ha ha dito ginagamit namin dito pipe sa waterline is ppr pade
Bkt kabayan kang bleder dpat lagyan m ng bleder pra mawala un hangin ..psenya n kabayan plamer kc ako d2 s saudi ...btu ngajan cold lang wlang hot madalilang..
Kung sakaling may leak kabayan sinsil po yan cmpre. Kahit naman po n pressure test yan bago buhosan pag nag k leak parehas lng po kalalabasan nyan sinsil. Nasa video naman po sinabi k kng bakit hnd n test yan bago buhusan. Cmpre pinacguro namin yan dahil hind nga hnd n test ganun lng po kabayan salamat
Maraming salamat po kabayan. Sa hydrotest namin gumagamit na lang kami pressure washer para mas mabilis mapuno tubo. Ok lang po kaya yun? O makakasira ng gauge pag mabilis tumataas pressure?
Asph hind k p po nasubukan yan pero sa tingin k hind masisira yan kabayan wag lang lalagpas sa capcty nung pang pressure test nyo yang kc gamit k 440psi
7:21 kung wala kayong pang leak test after nyo mapuno yan balikan nyo kinabukasa, kapag nabawasan ibig sabihin may leak hehe joke lang po. Mas maganda bago sementuhan ang water pipe line mag leak test na para madali mag repair. Salamat po
Bad idea - your pressure test after the putting the cement in the pipe...It should be tested before the concrete was poured...your test is too primitive....this test will not pass in my area...Also the drain line should also be tested at low pressure ....The pressure test in my area, all joints should be spray with pipe test bubble.....Your pressure gauge cannot detect a very small leak...tiny bubble leak....And what if there is a leak underneath that concrete?...
Bakit ngayon ko lang nakito to. May mali kasi sa testing nato. Una, dapat naglagay kayo ng tubo para labasan ng hangin at mapuno talaga ng tubig yung mga tubo at Pangalawa, dapat ang testing ay oobserbahan ng hndi baba ng 24 hours