AC Panasonic 3/4PK air conditioner is blinking on the indicator timer lights on the indoor AC, if the timer light is blinking indicating that there is damage to the air conditioner, damage can occur to the indoor AC or to the outdoor AC. So after checking the AC, it turns out that the damage that occurs in the outdoor air conditioner is the outdoor AC fan does not want to spin while the compressor is on, after checking the cause of the outdoor AC fan does not rotate is the outdoor fan capacitor is weak / damaged which causes the outdoor fan cannot rotate. Then it is replaced with a new capacitor and after that the AC outdoor fan can spin normally again, the air conditioner can cool down again and the timer light doesn't flicker again.
Good luck and success always ... cool greetings !!!!
* Receive AC service (wa: 081 999 021 433)
Denpasar-Bali Region.
7 май 2020