Part 2: Installation of new domestic water heater - which one did they chose? Tankless, Indirect or Traditional Tank?
Let's Make The Trades Great Again! Join Mikey Pipes Philanthropy, Inc., an IRS 501(c)(3) non-profit public charitable organization. Our mission is to offer free or low-cost plumbing, heating and cooling services to those in our community who can't afford to hire a professional. Help us here: www.paypal.com...
Curious on our dispatching and invoicing app? Check out HouseCallPro: tinyurl.com/Mik...
What’s in your Veto? Here is mine:
Veto TP-XXL amzn.to/3zX10vg
Testo Combustion Analyzer: amzn.to/3Zd7naH
Digital Manometer: amzn.to/3EDt5ey
Milwaukee M18 Blower: amzn.to/46iTo6j
Milwaukee M12 Fuel 1/4" Impact Driver amzn.to/3I9yLfI
Milwaukee PVC cutter: amzn.to/3sbrdUc
Mini Waterproof Storage bin: amzn.to/3yfgsEv
Wiha Allen Keys: amzn.to/33ipGmb
HIKMICRO B20 amzn.to/33iGklx
Furnace Switch amzn.to/31X89PT
Milwaukee Light amzn.to/3I38Lmh
Wagos amzn.to/34QoiaU
Milwaukee Set amzn.to/33vnQOz
Torpedo Level amzn.to/3no1oOk
Crescent set amzn.to/3GtZeV8
Wiha 7 piece set amzn.to/3rkISaK
Milwaukee step bit amzn.to/3I395Bv
Thermocouple Flare wrench: amzn.to/3noJZ8s
Ridgid 10” wrench amzn.to/3GvRnqa
Fluke non-contact tester amzn.to/31VQgAQ
Klein drivers amzn.to/3qoe21W
Knipex Wrenches amzn.to/3trzFjS
Klein 11-1 amzn.to/3tpsPLD
12” crescent amzn.to/3A0CZ6S
Gerber Gear Pocket Knife amzn.to/3foaW7I
Yellow Jacket Hand Ratchet amzn.to/3nrDgup
I am on Discord & WhatsApp!
Discord: / discord
WhatsApp Group: chat.whatsapp....
Mikey Pipes Uncensored: / @mikeypipesuncensored
New oval raised silver stickers are from:
Armored Decal Company Inc.
35 Victoria St. E, Unit 9
Alliston, Ontario L9R 1T3
(p) 705-435-6665
(e) ken@armoreddecal.com
(Tell them Mikey Pipes sent you)
Please support this channel and Mikey Pipes and consider the following…
Pipe Doctor FlexFit Embroidered Caps
Minimum donation of $37 is appreciated
(If you are international - please add a minimum of $40 for shipping/postage)
Shopping on Amazon? Please use my referral link amzn.to/2PjjS4v
Sticker Requests:
Do you want a sticker to show your support of this channel? Email your request to me! mike@mikeypipes.com
Name
Address
City, State, Zip
Consider making a donation of $5.00, or ANY amount, to the postage fund! I literally mail out stickers all over the globe. I've sent stickers to HVAC guys in Afghanistan, New Zealand & all over Europe.
PayPal is: office@pipedoc.net
Venmo: @PipeDoctor
CashApp: $mikeypipesny
Zelle: mike@mikeypipes.com
Want to send a love letter, note or gift? Our mailing address is:
Mikey Pipes, Inc.
1010 Central Avenue
Woodmere, NY 11598
#plumber #hvac #mikeypipes

Опубликовано:

 

7 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 122   
@thomasdeluca3711
@thomasdeluca3711 6 месяцев назад
Gas pressure after the regulator in the National Grid service area (Long Island) is set at between 5 - 7" WC which is 1/4 lb of pressure not 1/2".
@tjlovesrachel
@tjlovesrachel 6 месяцев назад
Depends on if it’s elevated pressure or not
@aaronkoster3940
@aaronkoster3940 6 месяцев назад
When calculating gas pipe sizing, you need to add equivalent length of fittings
@eldoradoboy
@eldoradoboy 6 месяцев назад
another great mikey pipes install!! Fit / Feel / Finish - when i worked for frigidaire years ago... those were the things we had to make sure customers felt were high quality.. of course things that worked were paramount.. but assuming everything worked, a customer's fit / feel / finish is really what would determine whether they used you again in the fiuture / and or recommended you to their friends
@TheRAMBO9191
@TheRAMBO9191 6 месяцев назад
I have been slacking on videos due to life. Great video! I think I'm caught up finally, was behind like 4 videos
@PipeDoctor
@PipeDoctor 6 месяцев назад
Welcome back!
@mattl643
@mattl643 6 месяцев назад
Nice job Mike and Mike.
@PipeDoctor
@PipeDoctor 6 месяцев назад
Thanks! We're like the dynamic duo of RU-vid, but with the same name!
@jamesrecknor6752
@jamesrecknor6752 6 месяцев назад
Good, educational video. Excellent training.
@PipeDoctor
@PipeDoctor 6 месяцев назад
Glad you enjoyed it!
@Cyprusdoctor
@Cyprusdoctor 6 месяцев назад
Excellent videos Mike ,keep up the good work !
@PipeDoctor
@PipeDoctor 6 месяцев назад
Thanks 👍
@scottmaz4063
@scottmaz4063 6 месяцев назад
Fantastic Woodmere water.
@user-rf4ps5co8r
@user-rf4ps5co8r 6 месяцев назад
Learn something new every day never knew you needed 12 inches or should have 12 inches above the water heater for a better draft
@PipeDoctor
@PipeDoctor 6 месяцев назад
Suggested
@throttlebottle5906
@throttlebottle5906 6 месяцев назад
yeah, but you rarely see it in the field, it's most often an adjustable elbow slammed direct on top the vent hood and minimal pitch to the chimney, which has the openings far too low. leftover dinosaur junk from many years ago. lol
@GoldenPlumbingNaples
@GoldenPlumbingNaples 6 месяцев назад
Excellent job. Excellent customer service. Excellent branding. Congratulations to the team for the hat trick 👏👏👏
@kat2641
@kat2641 6 месяцев назад
Nice work Pipe Dr!!! But I am disappointed ☹️ big ol’ Tank. For the rest of that unit life they will have to pay to keep ALL that water volume heated. I was so sure a wall mount unit 😢 don’t take a lot of space an the biggest plus is over their lifetime they only heat water when needed. But? With the older Gen. It is harder to sell them coz they are used to having tons of stored hot water.. but sweet install job!!❤❤ (edited fur a spell 👻 boo)
@PipeDoctor
@PipeDoctor 6 месяцев назад
It is what it is.
@scottmaz4063
@scottmaz4063 6 месяцев назад
Thank God you didn't touch that pipe in the ceiling.
@johnmeore2153
@johnmeore2153 6 месяцев назад
Love the way you work!! What about their kitchen stove for the overall BTU's?
@peter-pg5yc
@peter-pg5yc 6 месяцев назад
Lived with 2 tankless water heaters..id go with tanked all the way.
@junkyardspecial9608
@junkyardspecial9608 6 месяцев назад
I hope your customers realize the respect you have for there home ...
@bahopik
@bahopik 6 месяцев назад
8:48 FYI half a pound is 14" WC. You guys have unusually high pressures there in new York
@danfalvey6292
@danfalvey6292 6 месяцев назад
Hi from Boston
@compactc9
@compactc9 6 месяцев назад
I've had a pipe-undoing mystery for a while with central vacs, glued connections parting later on. Apparently I wasn't supposed to just de-burr the thing, but there's a lip on the outside that prevents the glue from working, and I have to shave this down as well. I don';t know if that's a PVC thing, or due to the special cutter used on central vac stuff, but I'm doing it, so we'll see how it goes.
@throttlebottle5906
@throttlebottle5906 6 месяцев назад
you VAC fellas need to learn to use cleaner(or primer). that junk is always falling apart, poorly supported, no room for expansion/contraction and shoddily ran... 🤣
@MrDmadness
@MrDmadness 6 месяцев назад
I was always tought to take combustion analysis above the flu collar.. i agree with your way, and this is how ive been doing them for a long time. I dont care what the gasses are doing after they get excess air , i want to know what the appliance is doing during combustion. :)
@PipeDoctor
@PipeDoctor 6 месяцев назад
👍
@aaronkoster3940
@aaronkoster3940 6 месяцев назад
Combustion should be tested before the diverter. Draft should be tested after.
@RGNHomeSolutions
@RGNHomeSolutions 6 месяцев назад
Traditional water heater is a great choice. The extra expense of yearly flushes and expensive parts negate any savings from a tankless unit. Indirect puts too much wear and tear on the boiler.
@tcoradeschi
@tcoradeschi 6 месяцев назад
One man’s data on the subject. “Extra expense” is a couple gallons of white vinegar and an hour of my time. My tankless is 6 years old and has required no parts, expensive or inexpensive. But then, I got 22 years out of the original 50 gallon tank, simply by flushing annually and replacing anode rods (hmm “expensive parts”?). Northwest NJ - not the hardest water I’ve ever dealt with, but still…
@RGNHomeSolutions
@RGNHomeSolutions 6 месяцев назад
I was thinking more like a tech coming to the house and charging $200-$300 to do the flush. @@tcoradeschi
@kwhite145
@kwhite145 6 месяцев назад
I've used The Techtanium without problems
@PipeDoctor
@PipeDoctor 6 месяцев назад
Thanks for sharing
@dgeoffreyfitton2836
@dgeoffreyfitton2836 6 месяцев назад
nice follow up paperwork Mikey
@pizzareviewwithkarrighione5576
@pizzareviewwithkarrighione5576 6 месяцев назад
M&M Nice clean job.
@PipeDoctor
@PipeDoctor 6 месяцев назад
Thanks 👍
@robertmartinez1228
@robertmartinez1228 6 месяцев назад
You remind me of John Goodman my boy. from that TV show from the 1990's Rosanne. Dan Conners. we west coast plumbers from Southern California love trippin' on them east coast New York plumbers. it's all good bro.just hackin'.
@richcarter9476
@richcarter9476 6 месяцев назад
Nice job getting that new water heater set up in that space. One question I have always wondered about is why do plumbers always use copper pipe on the pressure relief valve? PVC seems to have advantages such as not drawing heat out of the tank. Is it a code requirement to use copper? Is it just quicker since you have the copper on the truck? Thanks
@tccoggs
@tccoggs 6 месяцев назад
Not a fan of the Techtanium heaters. They are almost as expensive as stainless but are glass lined steel with anode rods. Pulled one recently that was 12 yrs old and heavily rusted inside.
@Irishgreen56
@Irishgreen56 6 месяцев назад
Excellent services indeed.
@greekmaster1001
@greekmaster1001 6 месяцев назад
it’s crazy I don’t know where you did this work but here in New York City you would have to pull a permit pressure test the entire gas piping in the house and have a physical inspection by DOB (gas rough pressure and finish inspection) RIDICULOUS
@PipeDoctor
@PipeDoctor 6 месяцев назад
Yup 👍
@Irishgreen56
@Irishgreen56 6 месяцев назад
God Bless you Mikey.
@dmitrynetes3102
@dmitrynetes3102 6 месяцев назад
Great work Mike! With a 160k boiler they could run a fairly large indirect. Is it the price of an indirect vs conventional water heater that tipped the scale? Thanks for great videos!
@raymondjacobs8429
@raymondjacobs8429 6 месяцев назад
Mike on your drip tubes, have you ever cut the bottom end at an angle? around 45* +/-, to keep the home owner from capping it off?
@PipeDoctor
@PipeDoctor 6 месяцев назад
No I haven’t thought of that
@raymondjacobs8429
@raymondjacobs8429 6 месяцев назад
One of my classmates back in 1997 HVCC, HVAC-R class@@PipeDoctor
@ktmrider707
@ktmrider707 6 месяцев назад
Is t it lined though. It has a clay liner I thought that’s all you need.
@MrDmadness
@MrDmadness 6 месяцев назад
Codes vary all over the place. I can only speak to my local codes ( Canada) here you pretty much must pull a chimney liner ( accordion style stainless steal or aluminium ) .. there are very very few exceptions as the condensate will compromise any mortar joints it encounters
@petepete3389
@petepete3389 6 месяцев назад
You mention at 8:25 in your video that the boiler was "grossly oversized". Wouldn't removing the indirect water heater make the boiler even more oversized? Are there any disadvantages to a grossly oversized boiler?
@throttlebottle5906
@throttlebottle5906 6 месяцев назад
the boiler should be sized for the total radiation elements in the home(and/or it's BTU needs), the indirect tank is never factored into the BTU requirement and if need be, placed as a priority zone with time limit failover back to heating. exception to that is a commercial setting where the indirect will run frequently to continuously to keep up with water heating demand, but in that case they usually go with standalone water heating setups.
@Steve-bm2zm
@Steve-bm2zm 6 месяцев назад
Love AO Smith
@PipeDoctor
@PipeDoctor 6 месяцев назад
Me too
@aaronkoster3940
@aaronkoster3940 6 месяцев назад
What guage was that flue Y
@gerard46ify
@gerard46ify 6 месяцев назад
how many do you find with the tank heat exchanger with a leak?
@joed9908
@joed9908 6 месяцев назад
Why would they let the water drain towards the gas meter and the side of the house.
@JeffEikenberry
@JeffEikenberry 6 месяцев назад
Those Fenix headlamps are awesome! 🔦😎😀
@PipeDoctor
@PipeDoctor 6 месяцев назад
I think so too!
@scottmaz4063
@scottmaz4063 6 месяцев назад
The man Mike G
@swaterman08
@swaterman08 6 месяцев назад
how do you like the Mini Therm? I was thinking about getting my Dad one. Small 900sq foot house. Ther math tells me 40k BTU, but I was going to buy the 60k
@compactc9
@compactc9 6 месяцев назад
Am I crazy for saying I'd have chosen to install an indirect that was designed to make use of that boiler's output? To me it seems the 136,000 BTU output of that thing will heat more water faster than the 40,000 in the tank unit. The houses I've been in that had indirect water heaters on big boilers, the hot water never seemed to run out, it felt like a tankless.
@compactc9
@compactc9 6 месяцев назад
I will say, sadly our tank heater just isn't suited to my taste in shower heads...
@hollidaydoc45
@hollidaydoc45 6 месяцев назад
Maxwell House, (not Folgers) good to the last drop. I wonder what's wrong with the last drop? It must taste like s...? 🤣🤣
@aaronkoster3940
@aaronkoster3940 6 месяцев назад
The old tank did not fail. The coil in the tank failed. The anode rod does not protect the copper coil.
@PipeDoctor
@PipeDoctor 6 месяцев назад
👌
@ezramamiye5522
@ezramamiye5522 6 месяцев назад
Good decision ' I'm against with tanklace heaters had bad experience with a navain tankless they the worst ever
@PipeDoctor
@PipeDoctor 6 месяцев назад
Thanks for sharing. Anyone else care to comment?
@deanguando1335
@deanguando1335 6 месяцев назад
Nice job.
@MarkNehemiah
@MarkNehemiah 6 месяцев назад
Feed me Mikey pipes! Have a great week!
@markamcampbell5795
@markamcampbell5795 6 месяцев назад
as you drain it shack it a couple of times.
@michaelx_usa1
@michaelx_usa1 6 месяцев назад
NYC code: Boiler and H2O tank should vent seperately. Need to drill another hole in the wall.
@PipeDoctor
@PipeDoctor 6 месяцев назад
This isn’t NYC
@user-rf4ps5co8r
@user-rf4ps5co8r 6 месяцев назад
Did you also include the stove is that gas
@PipeDoctor
@PipeDoctor 6 месяцев назад
No stove
@takearidewithme3589
@takearidewithme3589 6 месяцев назад
Water heater pans aren’t required in your jurisdiction?
@PipeDoctor
@PipeDoctor 6 месяцев назад
No
@takearidewithme3589
@takearidewithme3589 6 месяцев назад
The 2020 New York State plumbing code is the same as the ICC in 504.7 a pan must be installed if any damage could be done when installing a tank style water heater or water storage system. In my opinion damage could be done due to that water heater being in a tiny unfinished mechanical closet with finished space next to it. I wasn’t aware of this until we failed an inspection a few years back.
@ac-mech1265
@ac-mech1265 6 месяцев назад
Why no expansion tank ?
@hdshows8704
@hdshows8704 6 месяцев назад
Saludos Mikey’s
@JoshuaSHogg
@JoshuaSHogg 6 месяцев назад
Does the cooking stove factor in the btu equation too?
@PipeDoctor
@PipeDoctor 6 месяцев назад
All gas appliances do. Whatcha think, I wouldn’t include ALL gas appliances in a load calculation????????
@JoshuaSHogg
@JoshuaSHogg 6 месяцев назад
@@PipeDoctor I’m not a plumber, I was just wondering.
@Shawn_RHVAC
@Shawn_RHVAC 6 месяцев назад
You don’t need vac breaker?
@PipeDoctor
@PipeDoctor 6 месяцев назад
Nope
@Shawn_RHVAC
@Shawn_RHVAC 6 месяцев назад
That’s amazing. I would have figured New York of all places would require a vac breaker on the cold water line.
@PipeDoctor
@PipeDoctor 6 месяцев назад
@@Shawn_RHVAC I’ve never installed a vacuum breaker and I’ve never seen one on Long Island or NYC.
@Jessedog11
@Jessedog11 6 месяцев назад
do they have a gas stove?
@chuckq54
@chuckq54 6 месяцев назад
No gas stove?
@PipeDoctor
@PipeDoctor 6 месяцев назад
No
@JohnR9965
@JohnR9965 6 месяцев назад
4 finger banger
@PipeDoctor
@PipeDoctor 6 месяцев назад
Deep inside
@JohnR9965
@JohnR9965 6 месяцев назад
@@PipeDoctor lol
@neilcvids2583
@neilcvids2583 6 месяцев назад
in cider ?@@PipeDoctor
@markamcampbell5795
@markamcampbell5795 6 месяцев назад
mike and ike.
@mariusm3595
@mariusm3595 6 месяцев назад
Converting from indirect to a gas-fired tank made more financial sense ??
@PipeDoctor
@PipeDoctor 6 месяцев назад
Yes
@hunner9500
@hunner9500 6 месяцев назад
Having an indirect on a %80 gas fired boiler is basically useless. Only reason an indirect is financially better is if it’s connected to a condensing 90 plus percent gas boiler.
@mariusm3595
@mariusm3595 6 месяцев назад
@hunner9500 #1 indirect will have a higher 1st hour recovery rate. #2 no need to run additional gas line and vent. #3 stainless steel tank will outlast black steel every single time. As a direct replacement, I would definitely go with indirect.
@drodriguez394
@drodriguez394 6 месяцев назад
No, my company uses praxis I think it’s total dog shit
@DevinHVACInc
@DevinHVACInc 6 месяцев назад
No gas stove in house?
@PipeDoctor
@PipeDoctor 6 месяцев назад
No
@watomb
@watomb 6 месяцев назад
I didn’t think you would need to replace the tank. You had condensation on water intake line and no priority control board. I’m thinking I would have added that before putting a water heater. Maybe I missed something and being stupid
@RonR-pd9si
@RonR-pd9si 6 месяцев назад
What page is 4 fingers on in the manual?
@PipeDoctor
@PipeDoctor 6 месяцев назад
Ask your sister
@RonR-pd9si
@RonR-pd9si 6 месяцев назад
@@PipeDoctor lol
@martyober4833
@martyober4833 6 месяцев назад
Oversized to produce hot water in the winter?
@MrDmadness
@MrDmadness 6 месяцев назад
Water always gas priority circuit. A over sized boiler means less cycling of the boiler == less fatigue on the system. SMe same for a water tank, they lose some efficiency after they form a mineral ja, you can hear the pop pop crackle sounds when older tanks fire, it's the gasses expanding under the mineral dropout, we call it "kettleing" in the trade You'd rather have too many btu ( reasonably) than not enough. The lack of the chimney liner also makes the boiler less efficient as it doesn't vent properly, plus the condensate will eat away mortar and can compromise the chimney structure
@throttlebottle5906
@throttlebottle5906 6 месяцев назад
@@MrDmadness actually, oversizing a boiler will cause it to hit high limit very fast and short cycle.... the radiation elements can only put out so much heat(baseboard, radiators, coils, whatever), chance are that house has about half the output capability of the boilers output.
@MrDmadness
@MrDmadness 6 месяцев назад
@@throttlebottle5906 i hear ya and dont disagree, i was not referring to a grossly oversized
@karolbrzozowski4688
@karolbrzozowski4688 6 месяцев назад
Where is expansion tank?
@PipeDoctor
@PipeDoctor 6 месяцев назад
Not needed
@ThumperKJFK
@ThumperKJFK 6 месяцев назад
👍✌
@WilliamConway-pi5vy
@WilliamConway-pi5vy 3 месяца назад
Mike needs to to read dictionary
@PipeDoctor
@PipeDoctor 3 месяца назад
Okay 👍
@tedbell4416
@tedbell4416 6 месяцев назад
That's too much cocky 🤢
@eduardorodriguez-ei4mw
@eduardorodriguez-ei4mw 6 месяцев назад
The best drain pump.lyberty
@harryschrysan3183
@harryschrysan3183 6 месяцев назад
Chinizium lmao this guy 😅😂😂
@PipeDoctor
@PipeDoctor 6 месяцев назад
lol
Далее
Butch REACT to Creative way to fix damaged tile!
00:46
Leaking Boiler Disaster: House Flooded Emergency Call
18:16
30 Minute Secret Makes Your Water Heater Last Decades
13:03
Myth Busting! Tank -vs- Tankless Water Heaters
11:41
Industrial Cooler Major Problems
22:53
Просмотров 14 тыс.
Butch REACT to Creative way to fix damaged tile!
00:46