Тёмный

PC Q&A: 4-Piece Bathroom Rough-in & Venting MasterClass! 

PlumbingsCool
Подписаться 9 тыс.
Просмотров 823
50% 1

Thoroughly understanding proper plumbing drainage & venting rules creates FLEXIBILITY!
Every plumber knows how to rough-in and install the typical 3-fixture bathroom group, consisting of a toilet, lavatory and sink or bathtub. Almost always, the de facto solution would be to wet vent them together!
But what happens when you throw a FOURTH fixture into the mix...in this case a 2-inch floor drain serving a sauna room?
This is the situation a recent viewer posed to me with respect to plumbing work in house they were renovating...which led down to a whole rabbit hole of Basic Plumbing 101 goodness respective to drain waste and venting plumbing systems!
This twenty-minute video is chock-full of plumbing goodness and know-how...and touches on all kinds of topics imperative ways on how to rough in plumbing properly, from wet venting & individual venting rules, to air admittance valves (affectionately known as "cheater" vents in the trade), and even to sewage ejector...and all kinds of other plumbing rough in basics!
Hope this brings you all some value, and you enjoy it as much as I did making it for you all! 🙏
PRODUCT LINKS:
Precision Plumbing Products (PPP) P2-500 Trap Primer:
www.pppinc.net/products/trap-...
Oatey SureVent Air Admittance Valve:
www.oatey.com/products/air-ad...
____________________________________
CHAPTERS:
0:00 - Introduction
2:20 - Isometric Drawings
3:10 - Minimum Pipe Sizing
3:30 - Toilet Fixture Drain and Minimum Size
4:08 - Toilet Wet Venting the Rough-in
4:45 - Lavatory ("Sink") Rough-in and Connection
5:45 - Lavatory Wet Venting Rules & Requirements
6:20 - Ontario and Canadian Wet Venting Rules vs. US/UPC Code Rules
7:20 - Installing and Properly Venting the Sauna Floor Drain
8:12 - Floor Drain Trap Arm/Fixture Drain Requirements
9:10 - Priming a Floor Drain's Trap Seal with a Mechanical Trap Seal Priming Device (PPP P2 P500)
10:22 - Shower Drain Minimum-sizing and Venting
11:21 - Rules for Properly Back-Venting a Fixture
12:32 - Configuring the Shower Drain as a Wet Vent
14:07 - Substituting Real Proper Vents with Air Admittance Valves (AAV's) or "Cheater Vents"
15:22 - Air Admittedly Valve Installation Requirements
15:49 - Creative Venting: Using the Floor Drain as a Wet vent for the Shower
16:56 - Sewage Ejector Installation, and Drainage & Venting Size Requirements
18:22 - Warning Against Using Air Admittance Valves to Serve Ejectors or Closed Pump Systems
18:47 - Sewage Ejector Discharge Line Requirements: Union, Check Valve & Isolation Valve
19:14 - Outro
____________________________________
IMAGE ATTRIBUTION:
Province of Ontario Vignette Map - Wannapik.com
#plumbing #renovation #vent #drainage #bathroom #apprentice #Oatey

Опубликовано:

 

25 июн 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 14   
@ToastedToast21
@ToastedToast21 3 месяца назад
Nice video, sir. Brings me back to intermediate plumbing theory with you.
@PlumbingsCool
@PlumbingsCool 3 месяца назад
Ah, good times!!!
@TjMaclean-mb4kx
@TjMaclean-mb4kx 2 месяца назад
He is a very good shop teacher and isometric drawing too
@PlumbingsCool
@PlumbingsCool 2 месяца назад
Thank you! 🙏 You guys make it all worth the effort!
@Futureawaits178
@Futureawaits178 Месяц назад
Great video please make more
@PlumbingsCool
@PlumbingsCool Месяц назад
Thanks so much! 🙏 I promise you that I'm working on it!
@Inquisitor6321
@Inquisitor6321 Месяц назад
In the U.S. you cannot run a flat dry vent until you are 6 inches above the flood line of the highest fixture being vented.
@PlumbingsCool
@PlumbingsCool Месяц назад
I'm not sure which part of my video you're referring to, but here in Canada, an INDIVIDUAL dry vent can run horizontally on its way up to open air - although it does obscurely state that "all vents shall run as direct as possible to open air". The important thing is that the dry back vent connects to the trap arm ABOVE the drain's horizontal centerline (to minimize water from backing up into the vent). It's also important that any other connecting vents (thereby creating a Branch Vent, connect "above the flood level rim of the highest-connected fixture" (to prevent an unintended bypass). Otherwise, there are times when you'd NEED to run the vent horizontally below the FLR, such as when back-venting a bathtub or an island sink, which has its trap below the floor. The only exception where two vents CAN connect below the fixtures' FLR is for WET vents. Thanks for your feedback!
@socem2301
@socem2301 2 месяца назад
Legendary
@PlumbingsCool
@PlumbingsCool 2 месяца назад
🙏
@peybak
@peybak Месяц назад
Hello, I was wondering if you can answer my question. I had an outside bib that needed to be replaced. When I cut it, the pipe retracted into the wall. Just my luck. I can pull it out with my finger (it's a 2 inch hole in the wall). I want to hold the pipe or clamp it for a few seconds to solder on a fitting. Is there a product that does this? I don't want to use regular clamps because they might mess up the pipe. The other option I guess is to break a little bit of the concrete. I would appreciate any tips!
@PlumbingsCool
@PlumbingsCool Месяц назад
Hi there, and thanks for inquiring. Hopefully I can help you out with your dilemma. In that situation, I often to using Vise Grip locking pliers (preferably the mini ones, which are smaller and thus take up less space) to lock onto the pipe and stop it from slipping into the wall once you pull it out, and as you attempt to solder it (it will also free up your other hand! 😊). I acknowledge that you don't want to damage the pipe, but if you open the vise grip wide enough so that it squeezes the pipe ever so snugly, you shouldn't have a problem with the pipe becoming damaged. You don't want to apply so much pressure so that the pipe becomes oval when you squeeze it; you only want it snug enough so that when you let go of pulling the pipe, there is enough resistance from the vise grip to stop the pipe from slipping into the wall. If purchasing mini Vise Grips, try to find rounded Jaws as opposed to the straight ones, which will do a better job at holding the pipe more uniformly and minimize potential pipe damage. Here's an example of the mini Vise Grips I'm referring to: images.app.goo.gl/Mx9PYLFJXuGZexL68 (and next time, don't cut off the pipe unless necessary; that's the beauty of copper pipe compared to plastic pipe: Copper fittings can be sweat off and easily replaces, whereas with the latter, you're stuck with cutting off portion of pipe.) 😉
@peybak
@peybak Месяц назад
@@PlumbingsCool Thank you very much. I hope I can pull it off. I didn't know it would slip back into the wall to be honest. I won't do something like that ever again. I'll try the vice grip. Appreciate your advice.
@PlumbingsCool
@PlumbingsCool Месяц назад
Awesome. Let me know how it goes. Another perhaps quicker option might be to pull it out and temporarily wedge a piece of wood between the wall and the pipe. Just make sure the torch flame doesn't come into contact with the wood wedge to prevent it from catching fire. Good luck! 👍
Далее
Повага | GOVOR TikTok #govor #shots
00:53
Просмотров 290 тыс.
Mama Bear Helps Babies Across Road
00:30
Просмотров 1,2 млн
Wet Venting Video:1 - Wet Venting Basics
5:16
Просмотров 116 тыс.
Plumbing a bathroom
30:35
Просмотров 69 тыс.
Plumbing Vents
8:24
Просмотров 171 тыс.
PC Q&A: Expansion Tanks for Tankless Water Heaters
13:18
Wet Venting a Bathroom Group {PLUS MORE}
4:24
Просмотров 33 тыс.