Pioneer SX-780 kept blowing the main fuse. found one of the power packs to be bad. replaced both power packs to fix unit Here is a link to the power packs I used STK0050+ Pioneer SX-780 www.ebay.com/itm/125596917973
Appreciate this video, own 1 of these for about 21/2 years now and I know this will happen to me in Time. My opinion, cool white LED lighting is best way to go for this unit.
Can you provide me with the source for those custom STK-0050 modules. Dealing with same issue. I was wondering in F4 was a slow blow type mains fuse. Its not uncommon for the mains fuse to primary to be slow blow type. Packs removed no blow. Checked pins on both packs, one appears directly shorted, other one not. Replaced both with packs with new from ebay. Still blows. I understand most of these so called aftermarket modules are junk. Was going to test both new and see if one is shorted, if only one tests bad I will pair it with the one original that tested as un shorted with resistance test. If both of my new aftermarket STK packs are bad, I would like to buy those custom modules you installed. Source please, thanks my friend. 😎👍
@@tomaszzyzdorf9862 thanks, yes same fuse here. The 4amp tied to the input of primary winding of power transformers. Unit does not blow fuse with the one channels new STK pack removed, will install the one un shorted original I have and cross my fingers. Thanks for the link. Have a great week. 😎👍