PLC Programming MOV Instruction - Move Ladder Logic RSLogix Studio 5000 Example Tutorial System 

SolisPLC
Подписаться 49 тыс.
Просмотров 34 тыс.
50% 1

Опубликовано:

 

22 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 20   
@plcgeneralcontrol2880
@plcgeneralcontrol2880 2 года назад
keren banget pemaparannya, saya dari indonesia thank to chanel learn PLC Advance.
@aadilferoze3621
@aadilferoze3621 5 лет назад
Awesome Stuff! Well Explained!
@Automationacademytv
@Automationacademytv Год назад
Nice one
@chrisjay5127
@chrisjay5127 5 лет назад
So the equal box is just comparing the source A and B values and if the imported value (B) matches the source value (A) the rung becomes true? What are these boxes called?
@SolisPLC
@SolisPLC 5 лет назад
Chris, that's 100% correct. The EQU instruction is just there to indicate TRUE if both values are identical. They're called Ladder Logic Instructions. In this case, it's a conditional instruction since it resides on the left side of the ladder and is a condition for the rung to execute.
@chrisjay5127
@chrisjay5127 5 лет назад
@@SolisPLC Perfect thank you for all the help man. I'm am an electrician in the auto industry so I will be using the plc for minor program changes, testing and troubleshooting.
@cruzadanortenacn7092
@cruzadanortenacn7092 5 лет назад
DO they have to both same tag location? EX..controller tag to controller tag?(same controller) or can they be any program tag to main program..etc. because i a cannot move any DINTs (both program tags) . i am trying to move a zero to a dint and it will not change
@SolisPLC
@SolisPLC 5 лет назад
No, most instructions don't have this limitation. Only certain CONTROL based tags need to be specified as controller only. I can only think of the PID and MSG instructions right now, but there are several others.
@cruzadanortenacn7092
@cruzadanortenacn7092 5 лет назад
@@SolisPLC thank you for the reply! it ended up being the new routine i created was not added as a subroutine in main program! thanks again.
@tanmaysathaye5195
@tanmaysathaye5195 5 лет назад
Very nice algorithm! Its simple but a really usful one. Thank you for the knowledge😊.
@evggan2685
@evggan2685 2 года назад
Spasibo!
@DSNCB919
@DSNCB919 5 лет назад
Hmm I did this for temperature set point changing the temp from 150 to 125 all I changed was the destination and it worked I'm confused
@nelsonvermilyer8941
@nelsonvermilyer8941 4 года назад
Very helpful stuff, Thanks
@wilsonaguokolo3757
@wilsonaguokolo3757 Год назад
Nice
@altabaie
@altabaie 4 года назад
How to copy "Hello world" to MyString which is a variable of type STRING?
@azamghamari2737
@azamghamari2737 3 года назад
Thank you of your exciting video, how we can have access and read the amount of the register system_INT[2]?
@SolisPLC
@SolisPLC 3 года назад
It depends on what you want to do with the value. You can for example use an HMI to read this register and display the value on the screen. You can compare this value to another on the PLC using something like the GRT. Example: When Temperature Actual (GRT) Temperature Setpoint DO something.