Powerflex 525 Controls In Studio 5000 V32 | Start & Stop Commands With Speed Controls 

Shane Welcher
Подписаться 26 тыс.
Просмотров 16 тыс.
50% 1

Adding Powerflex 525 Start/Stop controls with speed reference using a speed pot with eh drive speed commanded through ethernet is exactly what is shown in this video.
Building off of the last three videos, now we start to program the Powerflex 525 drive for a simple control set-up of start & stop logic using our finite state machine.
Video Content:
Minute: 0:00 Adding a New Task in Studio 5000
Minute: 2:24 Adding our Main Routine
Minute: 3:00 Adding our Powerflex 5252 routine
Minute: 4:00 adding Powerlex 5252 logic controls on ladder logic
Minute: 9:30 Powerflex start/stop bits explained
Minute: 10:20 Adding Powerflex 525 speed controls in ladder logic
Minute: 13:10 Adding Speed Monitoring logic
Minute: 15:00 System testing using FactoryTalk SE HMI app
Minute: 17:35 Why we use the drive active bit for speed controls
I hope you enjoyed the video.
Thank you for watching the video.
Learn, Implement, Succeed
If you are interested in getting serious about your knowledge & learning how to better your career then check out our training center.
Visit:
allen-bradley-plc-training.te...
#Powerflex525 #Poweflex525LadderLogic

Опубликовано:

 

4 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 18   
@ShaneWelcher
@ShaneWelcher 3 года назад
Join Us & Learn More: allen-bradley-plc-training.teachable.com
@johnathonsummers2135
@johnathonsummers2135 3 года назад
Could you please explain why you have to multiply the speed input by 100?
@ShaneWelcher
@ShaneWelcher 3 года назад
​@@johnathonsummers2135 It's based on the parameter file of the VFD you are using. Or in other words, the parameter file of the Powerflex drive that is being used in the system. Sorry if I missed that in the video but I know I cover this in this series of videos. I understand that watching videos can be interesting at times & not so at others, with that said, it is important to watch all of my videos because I do cover details of whatever I talk about throughout. Also, note that I will be adding timelines to the videos in the future to better help anyone trying to find what they are looking for. I hope that helps...have a great day.
@jonathonlock361
@jonathonlock361 3 года назад
your videos are great thank you for your time and doing these videos i am just learning studio 5000 and these are great
@ShaneWelcher
@ShaneWelcher 3 года назад
Thank you
@autoworks.design5668
@autoworks.design5668 3 года назад
Do you have an example of control speed using high/low limit switches and timers? Such that if the low level is on and speeds up for every second it is on? Slows done when at the high level. Thanks
@ShaneWelcher
@ShaneWelcher 3 года назад
That is fairly simple to do if you would like for me to make one. I have similar logic controls in my training courses at www.allen-bradley-plc-training.com/
@SCADAExperts
@SCADAExperts 9 месяцев назад
Hello sir, I am facing one issues we have dam gate control application using PF 525 VFD. While gate opening we don't get any fault but when we start down operations VFD gives Overvoltage F005 alarm after 1 to 2 feet down from actual position. There are two cases 1 decelation time is 1 sec. Second 120Ohm 2.5kW DBR is used DBR Parameter is also selected Normal duty cycle also I checked with different duty cycle . Still problem is there so please guide me. Thank you.
@ShaneWelcher
@ShaneWelcher 9 месяцев назад
Sounds like you need to decrease the decel and if that doesn't help then you need to add a braking module to burn off any regeneration power from what you described.
@keeponwalking_2024
@keeponwalking_2024 3 года назад
Is it possible to control the powerflex without plc? Only Modbus tcp?
@ShaneWelcher
@ShaneWelcher 3 года назад
It's possible to control a Powerflex 525 with no plc controls.....yes You can use push button controls wired to the digital inputs or just use the keypad
@jrdz009
@jrdz009 2 года назад
Hi Prof, do you have an email address I can contact you? I need some quick help with a PF525 on LogixDesigner 32.11
@ShaneWelcher
@ShaneWelcher 2 года назад
Hello, thank you for your support. I have a one-on-one coaching program I made to help with custom things that anyone has trouble with. Mainly because of demand, I have limited time so if you are interested then please visit the link below for a one-on-one coaching session. www.allen-bradley-plc-training.com/p/factorytalk-view-studio-site-edition-training-live-with-q-a
@jrdz009
@jrdz009 2 года назад
Thanks prof, I checked your website yesterday, but couldn't find on it what I needed. My problem is I have 4 VFDs running and I need to read the current, I'm using LogixDesigner 32.11 and I changed the device definition so I can read the current, but when I downloaded the program to the PLC, the drives got faulty and can't connect to PLC, I can't find the buttons and tabs LogixDesigner 30 and 31 have to download the changes to the drive configuration tab, because no tab for drive in version 32, and can't download it online cause drive isn't connecting
@ShaneWelcher
@ShaneWelcher 2 года назад
@@jrdz009 If you need to read current then either add it to the drive configuration on the PLC IO for yh drives then download so the tags are used or just use that message instruction in the current program to read information front he drives.
@ShaneWelcher
@ShaneWelcher 2 года назад
@@jrdz009 The link I providing is for personal one-on-one training via a zoom meeting, you are aware of that correct?
@ShaneWelcher
@ShaneWelcher 2 года назад
@@jrdz009 I just made a video if you want to see it. For the message instruction setup. Email me at Shane@OnlinePLCSupport.com
Далее
Nice hiding.
00:43
Просмотров 3,5 млн
Лайфхак с колой не рабочий
00:16
Просмотров 297 тыс.
MC TAXI: АК-47
35:14
Просмотров 336 тыс.
PowerFlex 525 Position StepLogic
12:53
Просмотров 7 тыс.