Тёмный

PowerFlex 750-Series Drives I/O Setup 

Rockwell Automation
Подписаться 50 тыс.
Просмотров 46 тыс.
50% 1

In this video, we show how to configure the I/O for the PowerFlex 750 Series Drives. We cover the analog and digital I/O port locations, and which parameters in the drive to modify those I/O ports.

Опубликовано:

 

13 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 13   
@robertonogueira9874
@robertonogueira9874 2 года назад
It´s perfect. Ever for me, a Portuguese speaker, I was able to understand . Congratulations.
@Liamv4696
@Liamv4696 3 года назад
Completely intuitive.. I swear, control engineers must get off on making this stuff practically impossible to understand..
@georgehosny1427
@georgehosny1427 3 дня назад
How to installation a new encoder card type 20-750-ENC-1 ? and how to programming its parameters ?
@heraldomoscoso9237
@heraldomoscoso9237 3 года назад
perfect information
@alexandremaia200
@alexandremaia200 2 года назад
Boa noite Tenho um powerFlex 753 e gostaria de saber quais parâmetros preciso configurar para definir o Di1 como sentido de giro horário e o Di2 sentido de giro anti-horário. Configurei o Di1 no parâmetro 163 entrada digital 1 e está funcionando normalmente, já o Di2 no parâmetro 162 vai para 1 mas não gira como se faltasse referência de velocidade, ambas as entradas digitais serão acionadas por botoeira.
@onkarnathtiwari
@onkarnathtiwari Год назад
Where we can set up under load time protection in power flex 753
@muufcem8962
@muufcem8962 2 года назад
Can you make a video on how to download or upload parameters files from a PC.
@juniorelectrical499
@juniorelectrical499 10 месяцев назад
Hello, how to set the digital output (R0) to start and turn off the brake system on an AC motor?
@dhljin9222
@dhljin9222 9 месяцев назад
R(0) is use as an alarm relay if you want to active u need to use R(1)
@midhunvm11
@midhunvm11 2 месяца назад
Yellow led blinking, drive don't accept any command
@jamesdew8
@jamesdew8 2 года назад
I'm having trouble changing the parameter level from Basic to Advanced so that I can access Parameters 10, 51, 52,52 and 53
@roymetzger4862
@roymetzger4862 9 месяцев назад
Port 0 Parameter 301
@roby3603
@roby3603 2 года назад
Basicaly
Далее
How to Program an Allen-Bradley PowerFlex 753 Drive
9:47
ДЖЕФ  ЕЩЕ ПОМОГАЕТ!
09:37
Просмотров 365 тыс.
Power Flex 753 partida local e remoto | EducaDrives
29:17
PowerFlex 750 Series HIM Copy Cat How To
3:09
Просмотров 10 тыс.
Allen-Bradley PowerFlex 755 AC Drive
6:29
Просмотров 94 тыс.
PowerFlex 753 and 755 Parameters Upload Download
6:12
Просмотров 4,1 тыс.
PowerFlex 755TS Hardware Identification
2:57
Просмотров 3,4 тыс.
PowerFlex 753 Three Wire Control
5:31
Просмотров 14 тыс.
ДЖЕФ  ЕЩЕ ПОМОГАЕТ!
09:37
Просмотров 365 тыс.