Тёмный

PowMr New Version keeper Charge Controller Setup 

PowMr Solar
Подписаться 3,5 тыс.
Просмотров 19 тыс.
50% 1

In this video we will show you how to set up the PowMr new version keeper charge controller. Unlock the full potential of solar power with this easy-to-follow installation tutorial.
______________________________________________________________
Website
powmr.com/
Facebook
/ powmrsolar
Email:
support@powmr.com
See you in my next video! :)
______________________________________________________________
1: PowMr keeper Charge Controller Setup
• PowMr keeper Charge Co...
2: PowMr 60A MPPT Solar Charge Controller Setup
• PowMr 60A MPPT Solar C...
3: Discover the Cutting-Edge Features of the Charge Controller by Powmr!
• Discover the Cutting-E...

Наука

Опубликовано:

 

21 авг 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 172   
@asadahmed4708
@asadahmed4708 11 месяцев назад
Please remake the current manual book with full details and adding this function,i already bought this 20 amp controller and confused about some function because the current manual book don't have written the function's about you told
@Jayromemagtipon07
@Jayromemagtipon07 8 месяцев назад
Hi. If i use 3-3.7 lipo battery still i need bms or no need
@jethroasuncion6080
@jethroasuncion6080 5 месяцев назад
Hi! I am using the 1230 model with a 24V Gel battery bank setup. Note that I am using the preset parameters for GEL type batteries. The charge controllers indicate that I have a 23V power input however it shows that there is no charge current. Batteries are currently at 25.1V, if I am correct, according to the settings, this controller should start charging the batteries. Am I doing something wrong?
@PowmrSolar
@PowmrSolar 5 месяцев назад
Hi, please send your problem to this email: support@powmr.com. Please note that we may not be able to promptly respond to you due to the Lunar New Year. We apologize for the inconvenience this may take and thank you for your understanding. We wish you all the best!
@ronversluys1235
@ronversluys1235 10 месяцев назад
I am trying to figure out the LiFePO4 battery setting . I see in the instructions that they have listed LiPo and LiFe. When I enter that I have a 4-3.2v battery I get the symbol of LiFe. I have never seen the LiPo symbol. My question is do I have it set right? Thanks
@PowmrSolar
@PowmrSolar 10 месяцев назад
Hi, please send your problems to this email: support@powmr.com
@coupleadventure
@coupleadventure 25 дней назад
I already have this same model, but how to activate the rotation display like the old model so i dont have to operate the botton just to see some details on display..
@PowmrSolar
@PowmrSolar 24 дня назад
Please send your problem to this email: support@powmr.com.
@danielbituin4382
@danielbituin4382 9 месяцев назад
Please help how can i set my float votage into 12.6 only beacause im using 3s lithuim ion battery.thanks
@wzjiang856
@wzjiang856 9 месяцев назад
预设的电池类型的参数是默认的, 不能任意调节, 可以选 usr2 用户定义, 大部分参数可以调节.
@matttelz6014
@matttelz6014 4 месяца назад
How to I adjust the Resume charge voltage? With Lifepo4 setting it is 13.0V which is too low.
@PowmrSolar
@PowmrSolar 4 месяца назад
Please set the battery type to USE1 so that you can adjust the parameters yourself.
@danielbituin4382
@danielbituin4382 9 месяцев назад
How can I set up 40A mppt for 3s lithuim battery?I can't see set the float voltage at 12.6
@PowmrSolar
@PowmrSolar 9 месяцев назад
Hi, kindly send your problems to this email: support@powmr.com
@moesuki2810
@moesuki2810 8 месяцев назад
In a 24v load terminal system that supplies 24v, can it supply 12v power?
@aleksandersats9577
@aleksandersats9577 5 месяцев назад
If you set your batteries to 24v then no. You will need a buck converter to convert that to 12v.
@patrickc.3185
@patrickc.3185 9 месяцев назад
Hi, I'm using the POW-Keeper 1220. I selected SLD in the controller because based on the manual, if you are using a Sealed Lead Acid Battery of 12V, you should select SLD. My problem is in the SCC, the LVD is set too low at 10.8V. How can I change it to 12.0V? I long press the MENU button while LVD is selected but nothing happens. I need to increase the LVD to protect my battery.
@PowmrSolar
@PowmrSolar 8 месяцев назад
Please change the battery type to USR1 or USR2 before setting it up. If SLD is set, the system will automatically default LVD to 10.8V and cannot be modified.
@patrickc.3185
@patrickc.3185 8 месяцев назад
@@PowmrSolar Thank you. I will try setting it on USR2 and let you know if it will be successful.
@PowmrSolar
@PowmrSolar 8 месяцев назад
@@patrickc.3185 Okay.
@TonsTV13
@TonsTV13 10 месяцев назад
good day mam., LVD/under volatage protection settings that is ok for GEL 10.1?
@PowmrSolar
@PowmrSolar 9 месяцев назад
Yes, it's Ok.
@user-tm7ee1hu9z
@user-tm7ee1hu9z 5 месяцев назад
What 10.1 low voltage disconnect? GEL is 50/50
@jabaguealfredo
@jabaguealfredo 3 месяца назад
you can set the lvd to 12.3 using the usermode 1, when you choose the gel type mode, you cannot configure it manually
@MdSumon-ii9zr
@MdSumon-ii9zr 21 день назад
A few days ago, I bought the 30 amp machine that connected a Jinko 580-watt 24-volt panel. I am not getting any response from this machine, although the weather in my area is not good, the sun has not risen due to rain. Will I get no output from this controller if it's not sunny?
@PowmrSolar
@PowmrSolar 21 день назад
Please send your problem to this email: support@powmr.com.
@MdSumon-ii9zr
@MdSumon-ii9zr 21 день назад
@@PowmrSolar How to turn on photovoltaic input?
@PowmrSolar
@PowmrSolar 21 день назад
@@MdSumon-ii9zr Kindly check your email.
@MdSumon-ii9zr
@MdSumon-ii9zr 21 день назад
@@PowmrSolar please send
@eltonveras
@eltonveras 2 месяца назад
Eu tenho um 1230 com a versão 1.4. Como atualizar para a versão 1.7?
@ronversluys1235
@ronversluys1235 10 месяцев назад
Can anyone tell me if by picking the 4-3.2v battery then the LiFe symbol shows on the screen, are the charging parameters picked for me? I have a LiFePO4 battery and i dont need the resume, the constant voltage, equalization and absorption charge. All I need is the Low voltage protection and Float charge, Please correct me if I am wrong. Please tell me how to set this controller up correctly. Are the charging parameters user adjustable? Thanks
@PowmrSolar
@PowmrSolar 10 месяцев назад
Hi, please send your problems to this email: support@powmr.com.
@martinwragg8246
@martinwragg8246 6 месяцев назад
Hi, did you get an answer to your questions, I am going around in circles here !
@ronversluys1235
@ronversluys1235 6 месяцев назад
@@martinwragg8246 I got no help from powmr support. I studied every you tube I could find and eventually put my project on a shelf for later. I did feel by trying different button pushes I did get better at it but in the end I dont know if its set up right. I have an Epever MPPT that has a remote programer (M50 i think) that is much more user friendly and not much more money.
@bustersbashers2280
@bustersbashers2280 3 месяца назад
Same here….!
@Jayromemagtipon07
@Jayromemagtipon07 8 месяцев назад
And at LVD. Its says 9v cutoff voltage. But i want to increase the LVD to 11.1 or 3.7v per cell. But it can't edit. Its off. How. Can i turn it on to customize LVD 3s Lipo battery. Please help
@PowmrSolar
@PowmrSolar 8 месяцев назад
Hi, please send your problems to this email: suppoort@powmr.com
@faruksarder5096
@faruksarder5096 6 месяцев назад
I have pow keeper 1220 new version but not changing display data automatically in stanby. Like battery voltage, pv voltage, load etc. Not displaying automatically frequently.
@PowmrSolar
@PowmrSolar 6 месяцев назад
Hi, please send your problems to this email: support@powmr.com
@sunethpriyankara3524
@sunethpriyankara3524 Месяц назад
hi ! I have powmr powkeeper mppt 1220 controller Firmware version v1.7 . i have problem with this controller. i used 12v LiPO4 battery pack. battery is normaly charging ok. but after few hours battery fully charged the controller stoped charging. and i using the battey in day time the battery just keeps going drain and the controller doesn't charge the battery no matter how much sunlight there is. There is no such problem with my other controllers. I have a powmr mppt 60A controller, Even after the battery was fully charged during the day. The amount of amperes obtained from the battery is not reduced by the battery and is given from the panels through the charging controller. Now this 1220mppt after fully charging it cut off the solar panels and do not give any output to useing load . Then in the evening, the battery is half depleted. The battery will not be left to use at night.. my english is not good butI hope you understand. how can i fix this. thanks
@PowmrSolar
@PowmrSolar Месяц назад
please send your problem to this email: support@powmr.com. Our technical staff will handle it for you.
@martinwragg8246
@martinwragg8246 6 месяцев назад
Can 3 of these work in parallel connected to the battery with separate solar panels connected to each solar controller?
@PowmrSolar
@PowmrSolar 6 месяцев назад
Hi, this model can't be used in parallel.
@kazishazedakarim2006
@kazishazedakarim2006 10 дней назад
Hi... May I limit the ampere i want to charge the battery.... I want my battery will be charged at 5 amp and extra ampere, is it possible from user setting?
@PowmrSolar
@PowmrSolar 10 дней назад
Nope, this cannot be set.
@ritchiegarcellano8382
@ritchiegarcellano8382 9 месяцев назад
Hello maam. Im already bought powkeeper 1230. Same as your MPPt. Can i ask?. How about reserved settings if long press the MENU,will shown 19.2 directly. Its ok for that. My battery is 12v system. Sealed Lead Acid battery
@amyliu5169
@amyliu5169 9 месяцев назад
Hi dear sir, could you tell me which setting parameter you are asking? (the charging voltage? or the battery type?) Let me have a check for you.
@ritchiegarcellano8382
@ritchiegarcellano8382 9 месяцев назад
The last settings that i have shown, no01 or reserved settings, or nevermind that settings, because if put press MENU 3s will shown, other settings
@wzjiang856
@wzjiang856 9 месяцев назад
this setting is for RS485 comunication baudrate, 19.2 means 19.2K , this fuction reserve for future only @@ritchiegarcellano8382
@okpalamichael4162
@okpalamichael4162 10 месяцев назад
How can i set the charge controller for 6S (3.7v 18650 lithium battery) lithium battery? Pls reply ASAP
@PowmrSolar
@PowmrSolar 10 месяцев назад
You can set USEr1 or USEr2.
@lufemendes
@lufemendes 7 месяцев назад
Hi, I'm having an issue with my Keeper 1230 controller. The display isn't cycling through the different screens like current, voltage, and temperature. Any advice on fixing this? Thanks!
@PowmrSolar
@PowmrSolar 7 месяцев назад
Hi, kindly send your problems to this email: support@powmr.com
@luizhenriquemerhy1640
@luizhenriquemerhy1640 6 месяцев назад
É a versão do software instalado. O meu é U1.4 é também não fica trocando e os icones no display no LCD são diferentes dos que ficam mudando os dados, è igual ao deste video acima que também não muda .
@lufemendes
@lufemendes 6 месяцев назад
@@luizhenriquemerhy1640 Valeu, amigo!
@harrydelara413
@harrydelara413 10 месяцев назад
Hello, Can you help me? I have your product Powmr Keeper Mppt 20A, I am trying to change the Resume Charge to higher voltage like 13.6V but I am not able to set it. This is what I am doing. From Main Page > 3seconds Menu button > Resume Charge On Resume Charge page I am trying to press Menu for 3 seconds but nothing is happening. Battery type is already set to Usr1
@PowmrSolar
@PowmrSolar 10 месяцев назад
Please send your problems to this email: support@powmr.com
@harrydelara413
@harrydelara413 10 месяцев назад
​@@PowmrSolarI already sent to support, no answer until now.
@harrydelara413
@harrydelara413 10 месяцев назад
​@@PowmrSolar I'm good now. i used Usr2 instead. I cannot change parameters on Usr1
@jayveealvaro8518
@jayveealvaro8518 6 месяцев назад
hi im using powmr 1220. Im using GEL battery I set the mppt to gel but the LVD is too low at 10.8V cannot be change to 12.0V how can i change it to 12.0? thank you
@PowmrSolar
@PowmrSolar 6 месяцев назад
Please send your problems to this email: support@powmr.com
@user-tm7ee1hu9z
@user-tm7ee1hu9z 5 месяцев назад
Me too.. the GEL type is 50/50 DOD.. 10.8V is too low.
@PowmrSolar
@PowmrSolar 5 месяцев назад
@@user-tm7ee1hu9z Please send your problems to this email: support@powmr.com
@edilbertoego-ogan
@edilbertoego-ogan 6 месяцев назад
My Pow keeper1220 new version is not changing display is it good or not ?
@PowmrSolar
@PowmrSolar 6 месяцев назад
Hi, kindly send your problems to this email: support@powmr.com
@01lovemusic01
@01lovemusic01 4 месяца назад
Hi! I have two 260AH LifePo4 batteries 🔋🔋 Can you please me how to set into Powmr Power keeper 30A for this? 14.6V what mode? Is that USER2? Thanks.
@PowmrSolar
@PowmrSolar 4 месяца назад
Hi, please send your problems to this email: support@powmr.com. Our Technical staff will handle it for you.
@01lovemusic01
@01lovemusic01 4 месяца назад
@@PowmrSolar I did send it on March 08 but I got no response!
@PowmrSolar
@PowmrSolar 4 месяца назад
@@01lovemusic01 Can you send us your email?
@koioskobesarmiento9521
@koioskobesarmiento9521 27 дней назад
how to nake the display scroll?
@maheshindrasingha5923
@maheshindrasingha5923 8 месяцев назад
Can I use 7s Lithium-ion battery packs(18650) with 250w solar panels(VMP 30.3v)(voc 38v)?
@SpSolar
@SpSolar 6 месяцев назад
Nem eles sabem!
@vitortavares6443
@vitortavares6443 Месяц назад
Kkkkkkkk
@allanenopiaae
@allanenopiaae 6 месяцев назад
i use lifepo4 battery and choose setting 4:3.2v..my problem is..error when the voltage are 14v when charging
@PowmrSolar
@PowmrSolar 6 месяцев назад
please send your problems to this email: support@powmr.com.
@mohammadniaz1986
@mohammadniaz1986 2 месяца назад
I can use 40 amp mppt for my 280 ah tubleal bettery
@PowmrSolar
@PowmrSolar 2 месяца назад
Yes.
@odeiocomunistas
@odeiocomunistas 3 месяца назад
I bought one of these and put it on a stationary 12v battery but it doesn't charge all the way, the battery doesn't last long and turns off the inverter, give me the settings for this type of battery please.
@PowmrSolar
@PowmrSolar 3 месяца назад
Please send your question to this email: support@powmr.com.
@mostiboysvlog5695
@mostiboysvlog5695 11 месяцев назад
How to set float voltage mine is maintain to 13.8 for Lifepo4 battery
@amyliu5169
@amyliu5169 11 месяцев назад
Hi, before you set Float votage, you need to set your battery type "US r1", then set Constant charge voltage and Absorption charge voltage first. Keep the Constant voltage and Absorption voltage are higher than Float votage.
@amyliu5169
@amyliu5169 11 месяцев назад
When you see the interface you want to change the set or parameter, you can long press the "up" button for over 3 seconds, then press "up" or "down" to select the parameter you want to choose. After you selected the parameter you need, long press "up" button again to save the setting selection.
@moesuki2810
@moesuki2810 10 месяцев назад
The maximum value of the output load terminal is approximately how many amps?
@PowmrSolar
@PowmrSolar 10 месяцев назад
5A.
@adofatma2400
@adofatma2400 Месяц назад
​@@PowmrSolarthe manual book says DC output rated discharge current is 20A for 1220 and 1230, and 30A for 1240. Which one is correct?
@PowmrSolar
@PowmrSolar Месяц назад
@@adofatma2400 Yep, the rated charge current is 20A for 1220; 30A for 1230; 40A for 1240.
@marklenrodolfo5030
@marklenrodolfo5030 9 месяцев назад
How can i reset my powmr mppt same as your video. Becouse my unit is charge at 12.8 in daytime but in 6pm around the voltage shuld drop to 11.9
@PowmrSolar
@PowmrSolar 9 месяцев назад
Hi, kindly send your problems to this email: support@powmr.com.
@alanpc16
@alanpc16 3 месяца назад
Tenho uma dúvida.... quando ele entra no modo mppt em 12v qual é a voltagem mínima dos painéis para que ele entra no modo mppt. Meu sistema é 12v duas placa de 155w em paralelo e ele não arma o modo mppt é o 1230
@PowmrSolar
@PowmrSolar 3 месяца назад
For 12v system: the voltage range is 12V-75V, Max. Input Power: 390w.
@eltonveras
@eltonveras 2 месяца назад
Eu acredito que você tem que colocar as duas placas em série para o mppt entrar em ação. Boa sorte.
@mshah5325
@mshah5325 10 месяцев назад
Please tell the maximum DC load watts. thank you
@PowmrSolar
@PowmrSolar 10 месяцев назад
Which model?
@PowmrSolar
@PowmrSolar 10 месяцев назад
24V X 5A = 120Watts.
@mannynoleal7521
@mannynoleal7521 7 месяцев назад
Is this have a LCD backlight?
@PowmrSolar
@PowmrSolar 7 месяцев назад
Hi, this model doesn't have a LCD backlight.
@bakalito4601
@bakalito4601 9 месяцев назад
What are the default values for 24v Gel Battery?
@PowmrSolar
@PowmrSolar 9 месяцев назад
Equalized charging voltage: GEL: No Absorption charging voltage:GEL: 14.2 Floating charging voltage:GEL, Lead acid flooded battery: 13.8 Low voltage re-connection:GEL, Lead acid flooded battery: 12.6 Low voltage disconnection:GEL, Lead acid flooded battery: 10.8
@ThanWin-nn9un
@ThanWin-nn9un 2 месяца назад
I am using POW MR, POW Keeper 1240, SOLAR CHARGE CONTROOLLER. The box is showing 'ERRO' and how I can solve this error, please help.
@PowmrSolar
@PowmrSolar 2 месяца назад
Please send your problem to this email: support@powmr.com. Our technical staff will handle it for you.
@martinwragg8246
@martinwragg8246 6 месяцев назад
Can the firmware be updated? I have V1.4
@PowmrSolar
@PowmrSolar 6 месяцев назад
Please send your problems to this email: support@powmr.com
@markrichardmabalay6750
@markrichardmabalay6750 11 месяцев назад
Hello, how to set for 8s lifepo4?
@amyliu5169
@amyliu5169 11 месяцев назад
You can choose "USr 1"
@user-hershey_2015
@user-hershey_2015 5 месяцев назад
This scc protect HVD,LVD....?
@PowmrSolar
@PowmrSolar 5 месяцев назад
Please send your problem to this email: support@powmr.com.
@johncarlobernardo866
@johncarlobernardo866 10 месяцев назад
how to see PV WATTAGE OUTPUT? IN THE NEW CONTROLLER
@PowmrSolar
@PowmrSolar 10 месяцев назад
HI, can't see the PV Wattage directly, but you can see the volts and amperes.
@lexiengapngagap2752
@lexiengapngagap2752 Месяц назад
how can you activate the two usb portals
@PowmrSolar
@PowmrSolar Месяц назад
The controller has an operation mode setting item, which can be set on the Ld4 interface.
@guilhermesilva9280
@guilhermesilva9280 5 месяцев назад
Gostaria de um tradução para o português Brasil, estou com dificuldade para configurar o meu pow keeper 1230.
@PowmrSolar
@PowmrSolar 5 месяцев назад
Hi, please send your problem to this email: support@powmr.com
@eumesmo-kd1tr
@eumesmo-kd1tr 7 месяцев назад
What are the default values for 24v LiFePO4 Battery?
@PowmrSolar
@PowmrSolar 7 месяцев назад
Equalized charging voltage Maintenance-fee lead acid battery: 14.6V; GEL: No; Lead acid flooded battery: 14.8 Absorption charging voltage Maintenance-fee lead acid battery: 14.4V; GEL: 14.2; Lead acid flooded battery: 14.6 Floating charging voltage Maintenance-fee lead acid battery, GEL, Lead acid flooded battery: 13.8 Low voltage re-connection (LVR) Maintenance-fee lead acid battery, GEL, Lead acid flooded battery: 12.6 Low voltage disconnection (LVD) Maintenance-fee lead acid battery, GEL, Lead acid flooded battery: 10.8
@eumesmo-kd1tr
@eumesmo-kd1tr 7 месяцев назад
@@PowmrSolar thanks a lot but what about LiFePo4 battery at 24 V , BR
@PowmrSolar
@PowmrSolar 7 месяцев назад
@@eumesmo-kd1tr Generally, you can find the specific reference value of the battery in your lithium battery manual. Then set the battery type to USE on the controller, and you can customize the lithium battery parameters according to the reference values ​​in your battery manual.
@eumesmo-kd1tr
@eumesmo-kd1tr 7 месяцев назад
@@PowmrSolar yes thanks, i was looking for the values and how to change it, but now i could find it, now i will connect with my other controller in parallel with the same values than my epever controller BR
@diedampfbrasse98
@diedampfbrasse98 3 месяца назад
Update your user manual downloads!!!! also would be nice to allow setting the Li capacity in exact values instead of just giving 5AH steps
@MdSumon-ii9zr
@MdSumon-ii9zr 23 дня назад
How to enable equalization mode?
@PowmrSolar
@PowmrSolar 22 дня назад
Automatic equalization every 28 days
@a.arestovich
@a.arestovich 3 месяца назад
Is it possible to connect the 220 inverter to the controller load instead of the battery?
@PowmrSolar
@PowmrSolar 3 месяца назад
You can only connect to the battery.
@cenonvillanueva3045
@cenonvillanueva3045 10 месяцев назад
How to set at low voltage disconnect for lead acid battery
@PowmrSolar
@PowmrSolar 10 месяцев назад
Hi, please send your problems to this email: support@powmr.com.
@cenonvillanueva3045
@cenonvillanueva3045 10 месяцев назад
@@PowmrSolar the lvd of scc is 10.8 , i change of 12.9 but i se the but 10.8 is dont blink i press for 3 second or long press botton up to menu
@maheshindrasingha5923
@maheshindrasingha5923 7 месяцев назад
Hello ..can I use 7s Li-ion battery packs with this ?
@PowmrSolar
@PowmrSolar 7 месяцев назад
Yes.
@szkarlatny_pumpernikiel
@szkarlatny_pumpernikiel 3 месяца назад
Hello, to the refreshed product should attach a new manual. I in my product got the old one and it caused me no small problem. I also have reservations about the menu on the display, it is so terribly unintuitive until a person is pissed off how to touch it. It is user unfriendly!😤
@PowmrSolar
@PowmrSolar 3 месяца назад
Hi, sorry for the inconvenience. Please send your questions to this email: support@powmr.com
@01lovemusic01
@01lovemusic01 11 месяцев назад
No option to see PV voltage?
@PowmrSolar
@PowmrSolar 11 месяцев назад
This video is not connected to PV. You can see it directly after connecting to the PV.
@amyliu5169
@amyliu5169 11 месяцев назад
Hi, have you bought the Keeper 1240?@@NeverMind-pk4wz
@user-mg5uf9cb1i
@user-mg5uf9cb1i 9 месяцев назад
My dear sister...My have 30A PowMr Mppt Soler charge controller... But I Don't no setting ... You halp me ...
@PowmrSolar
@PowmrSolar 9 месяцев назад
Hi, kindly send you problems to this email: support@powmr.com
@josephaltona724
@josephaltona724 11 месяцев назад
Pa send nga po ng vedio yong new version ng mppt30amper kc herap ng settings nya po
@lufemendes
@lufemendes 7 месяцев назад
Is this a MPPT or a PWM?
@PowmrSolar
@PowmrSolar 7 месяцев назад
Hi, MPPT.
@kmrubel308
@kmrubel308 11 месяцев назад
What is the way to reset Please tell me a little...
@amyliu5169
@amyliu5169 11 месяцев назад
Hi, there is no reset setting selection on the LCD display.
@kmrubel308
@kmrubel308 10 месяцев назад
Thanks for the reply, it would be nice to have a restart system...
@kmrubel308
@kmrubel308 10 месяцев назад
The product is very good...
@charlesgayon8738
@charlesgayon8738 10 месяцев назад
Why cant i change the parameters for my batery
@PowmrSolar
@PowmrSolar 10 месяцев назад
What parameters?
@charlesgayon8738
@charlesgayon8738 10 месяцев назад
@@PowmrSolar the equalization charge the resume charge constant voltage charge and the float charge
@charlesgayon8738
@charlesgayon8738 10 месяцев назад
Im using lifepo4
@PowmrSolar
@PowmrSolar 10 месяцев назад
@@charlesgayon8738 Is your battery type set to usr1 or usr2?
@charlesgayon8738
@charlesgayon8738 10 месяцев назад
4-3.2
@marklenrodolfo5030
@marklenrodolfo5030 10 месяцев назад
What is mean E-11
@PowmrSolar
@PowmrSolar 10 месяцев назад
Hi, E11: 12V system battery low voltage protection.
@terk7121
@terk7121 10 месяцев назад
The ! symbol always shows what does that mean? what I did wrong.
@PowmrSolar
@PowmrSolar 10 месяцев назад
Hi, are there any other fault codes? Only ! symbol?
@terk7121
@terk7121 10 месяцев назад
@@PowmrSolar Yes and i also cann't set any parameter when i press the button.
@moesuki2810
@moesuki2810 10 месяцев назад
ไม่สามารถตัเงค่า พารามิเตอร์ได้เช่นกัน
@poppybusiness
@poppybusiness 10 месяцев назад
yes, me too can't set up
@user-tm7ee1hu9z
@user-tm7ee1hu9z 5 месяцев назад
Me too .. complected new version 😢
@lucianotavares9378
@lucianotavares9378 5 месяцев назад
Preciso de um em português
@PowmrSolar
@PowmrSolar 5 месяцев назад
Hi, this model(POW-Keeper1220)?
@ryuhayabusa3510
@ryuhayabusa3510 Месяц назад
pano mag set up ung latest mppt
@PowmrSolar
@PowmrSolar Месяц назад
what the latest mppt?
@MyintSwe-h3z
@MyintSwe-h3z 21 день назад
မြန်မာလိုရှင်းပြပါလားခင်ဗျာ
@rkradhakrishna5612
@rkradhakrishna5612 5 месяцев назад
It is better to give video in Bengali for Bengali
@royfitrah8507
@royfitrah8507 8 месяцев назад
New version controller
@PowmrSolar
@PowmrSolar 8 месяцев назад
New version Keeper.
@royfitrah8507
@royfitrah8507 7 месяцев назад
I like this pow keeper ❤
@8126926
@8126926 6 месяцев назад
keep your finger off the controller until you are actually ready to press a button. you are confusing the crap out of me.
@andersonaraujo5333
@andersonaraujo5333 6 месяцев назад
wow, this version is very complicated, please go back to the previous version, this one is very bad.
@PowmrSolar
@PowmrSolar 6 месяцев назад
please send your problems to this email: support@powmr.com.
@user-tm7ee1hu9z
@user-tm7ee1hu9z 5 месяцев назад
Yeah
Далее
How to Size a Solar Charge Controller
8:44
Просмотров 69 тыс.
Surprising Power Gains By Cooling Solar Panels
9:52
Просмотров 533 тыс.
ОШИБКИ НА ANDROID 2
5:13
Просмотров 28 тыс.
APPLE дают это нам БЕСПЛАТНО!
1:01
Просмотров 731 тыс.