We have installed a Lightning protection from this company last year, really convinced with the product quality and customer service. Still remember the support from Mr. Manish and Kiran. You can trust them.
ESE lighning protection and Spd are very needed where sensitive electronics items are used. These days surge through kseb lines and ligntning are increasing day by day and most electronics/ ac companies will deny warranty due to issues caused by lightning /surge. Install these devices from a proper company with right devicee and good workmanship....
Bro, please note in India as per NBC-2016 ( National building code ) Lightning protection system like ESE air terminal are banned because it's not scientifically proven to provide protection for radius of 50 meters or more .Also there is no backup from IEC - 62305 standards for ESE Air terminal. So kindly don't mislead people, ESE air terminals are promoted just to make huge profit since ESE are made of stainless steel not copper
അവതരണം അത് വേറെ വിഷയം ഒരു paid promotion ആണോ എന്ന് സംശയിച്ചാല് തെറ്റാകില്ല ഇത് എന്റെ മാത്രം അഭിപ്രായം ഒരു 15000 വരെ ചിലവിനു 85000 വരെ ചാര്ജ് ആവുന്നതായി അറിയുന്നു
@@anarysaji നിർബന്ധമായി ഈ പ്രൊഡക്ട് തന്നെ വാങ്ങണമെന്നില്ലല്ലോ . പ്രധാനമായും ഇൻഫർമേഷൻ അല്ലേ നമ്മൾ പങ്കുവെക്കുന്നത്. ഇതിനെ പറ്റി അറിയാൻ ആഗ്രഹിക്കുന്നവർക്ക് ലളിതമായി കാര്യങ്ങൾ പറഞ്ഞു കൊടുക്കാനാണ് വീഡിയോ ചെയുന്നത് .
ESE units perform no better than a simple, standard, lightning rod of equal height. The “protected zone” for a 20’ tall device turned out to be approximately 25 meters, not 100 meters as claimed.
ESE” (Enhanced or Early Streamer Lightning Protection) This type of lightning protection is likewise not accepted or recognized by US code authorities. Even though several appeals by supporters of these products including an independent scientific review panel and multiple appeals, NFPA refused to approve a separate standard for this equipment and continues to exclude it from the recognized NFPA 780 lightning protection code. Further, in field test caused by a lawsuit initiated by ESE proponents, it was found that ESE units perform no better than a simple, standard, lightning rod of equal height. The “protected zone” for a 20’ tall device turned out to be approximately 25 meters, not 100 meters as claimed. Subsequently, in that suit a US Federal Court ruled (Ruling No. CIV 96-2796 PHX/ROS) that this equipment did not perform as claimed and by ruling prohibited them from advertising any enhanced “zones”. Finally, even in Europe where these products started, I.E.C. Codes and European Standards no longer allow the use of this equipment.
രണ്ടു മീറ്ററിൽ താഴത്തേക്ക് കോപ്പർ റോഡ് ഇറക്കുന്നത് പുഴ, കായൽ, കടൽ, ചതുപ്പ് നിലം എന്നിവിടങ്ങളിലെ ഒറ്റ ഗ്രൗണ്ടിങ്ങ് വേണ്ടിടത്ത് മതിയാവും, അവിടെ ഒരടി പോലും മതിയാവും. ജലാശം കുറഞ്ഞ തലങ്ങളിൽ പാരലൽ എർത്തിങ്ങ് ( റാഡ് ) വേണ്ടി വരും. അവിടെ 2 മീറ്ററിൽ കൂടുതൽ ഗ്രൗണ്ട് റാഡ് അടിക്കരുത്. റാഡുകളുടെ നീളം, കനം, തമ്മിലുള്ള അകലം ഒക്കെ പരിഗണിക്കണം. LP യുടെ വാറൻ്റി 50 വർഷമാണ്.
Explained nicely. But ESE is not a proved technique. Better don't waste money on it. Franklin rod or Faraday net is practically very effective. Also please check the effectiveness plate earthing and rod earthing
Bro, please note if lightning hits a train, people inside it are safe because train has a metal body and electricity will flow through exterior metallic body of train, not because of railway track is properly earthed. Boeing and Airbus passenger airlines are hit by lightning in the sky and people inside it are safe because of exterior metal body through which electricity passes smoothly
10 ലക്ഷം രൂപയുടെ വീടിന് insurance എടുക്കാൻ ഒരു വർഷം ചെലവ് 350/- രൂപയിൽ താഴെ മതി. പൊതു മേഖലയിൽ ഉള്ള 4 insurance കമ്പനികളിൽ നിന്ന് ഇത് എടുക്കാം . ഇത്തരം insurance policy ക്ക് ഇടിമിന്നൽ , വെള്ളപ്പൊക്കം , ഭൂകമ്പം ഉരുൾപൊട്ടൽ തുടങ്ങിയ പ്രകൃതിക്ഷോഭങ്ങൾ നിന്ന് സംരക്ഷണം ലഭിക്കും ഇതാണ് ഏറ്റവും ചെലവുകുറഞ്ഞ സംരക്ഷണം രീതി . ഞാൻ എടുത്തിട്ടുണ്ട്
@@sijothomas8925 1.The new India assurance company 2. United India insurance company 3. National insurance company. 4. Oriental insurance company ഇവ എല്ലാം പൊതുമേഖല സ്ഥാപനങ്ങൾ ആണ് ( Central Government)
@@hemajohn9006 ഒരു സാധാരണ കുടുംബത്തിന് താങ്ങാവുന്ന നിരക്കിൽ ഉള്ള ഒരു ഉപായം പറഞ്ഞു എന്ന് മാത്രം 350 രൂപയ്ക്ക് 10 ലക്ഷം രൂപയുടെ coverage ലഭിക്കുന്ന മറ്റൊരു scheme പറയൂ
Brother ഞാൻ നിങ്ങളെ duscourage ചെയ്യുവാന് പറഞ്ഞത് അല്ല 🙌 ആദ്യം life safety അല്ലെ important lightning ഇല് ഒരു വീടും അതിലുള്ളത് നശിച്ച് പോയിട്ട് insurance claim ആന്നോ അതോ അതു prevent ചെയ്യുന്ന lightning arrester വയ്ക്കുന്നത് ആണോ better 😊 വീട്ടില് ഉപകരണങ്ങൾ fan അടക്കം കത്തിയ അനുഭവം അതാണ് ഒരു മുന്കരുതല് എന്ന പോലെ comment ഇട്ടത്🙌please don't misunderstanding
Hey man, this ESE system is not allowed in India as per IS ( even some engineers recommend this due lack of knowledge ( also want to increase the cost of installation, so more commission🤪) and studies says that , building with ese lightning system attract strikes to home, so house without😡 ese arrester is safer .... And these companies are using a threathening marketing method to sell 16000 rated products at a rate of 70000 to lakhs.
ഞാൻ 2016ൽ ആണ് ഇത് വെച്ചത്.. TVM ലെ ഒരു കമ്പനി വച്ചു തന്നു..... Imported copper.. Belt ആണ് അവർ കണ്ടക്ടർ ആയി ഇട്ടത്..... ഒരു വലിയ കുഴി എടുത്തു അതിൽ ഒരു മോട്ടോർ പോലെ ഉള്ള device അതിൽ വച്ചു പിന്നെ.. ഒരു കെമിക്കൽ ഇട്ടു.. മണ്ണിട്ട് മൂടി...20മീറ്റർ radius കിട്ടും എന്ന് പറഞ്ഞു... സോളാർ പാനൽ കൾ.. Roof topil ഉള്ള ത് കാരണം.. Thunderbolt.. Attraction വന്നേക്കും എന്ന് തോന്നി
Hi bro, njan kettirikunathu lightning arresters nu down conductor ayi itil kanichapolathe insulated thin stranded copper conductors use cheyila ennanu.. onukil solid copper strips of specific thicknes and width(like the one in this video) or single or multiple strands of high gauge solid copper cables (insulated or non insulated ) . reason is current carrying capacity a typical lightning is assumed to be around from atleast 40KV to 200KV or more and a current rating of atleast 5kA or above. So these thin stranded cables individually will overheat or melt/break instantly or overtime even if the overall gauge of the wire is higher. and from the video the printing on the wire says rating of upto 1100V so the risk of failure is higher while the solid copper stip can handle such high surge of current and voltage :).. next best option is aluminium but only as down conductors, and connecting aluminium down conductor to copper air terminal and copper ground terminals should be galvanically coupled to avoid corrosion and increasing resistance. benefit is price, availability and no risk of theft. ESE is not needed at all no extra benefit for customer or their home but only for the dealer and the company.. normal conventional spiked air terminal is more than enough :)
Very informative video, one of the best.. I was looking for this information, can you please clarify we will get subsidies for this installation from government or not...
കോപ്പർ ബോണ്ട ഡ് റോഡ് ഉപയോഗിച്ചാൽ ഒത്തിരിക്കും പിന്നെ ഒരു ബക്കറ്റ് വെള്ളം ഒഴിച്ചു ന്ന് വിചാരിക്കുക നിങ്ങൾ തടഞ്ഞ് നിർത്തു. ഒരു പമ്പ് ഉപയോഗിച്ചു നിങ്ങൾ തടഞ്ഞ് നിർത്തും ഒരു ഡാം പെട്ടി വന്നു എന്ന് കരുതുക ഉടൻ ഒരു പാട്ട് കേൾക്കാം ആമ്പൽ ആമ്പൽ എന്ന് പറഞ്ഞാൽ മിന്നൽ അത്രയേ ഉള്ളു
These are non standard lighting protection system. Please don’t promote these kind of non standard systems which is already banned as per Indian standards. Use a system based on IS/IEC 62305 standard.
ലൈറ്റനിംഗ് അല്ല bro. ലൈറ്റ് നിoഗ് എന്ന് പറയുക. Lightning = ഇടിമിന്നൽ Light E ning = കത്തിക്കൽ enlighten (ment) = ജ്ഞാനോദയം. video മോശമല്ല . informative ആണ്.
ഒരിക്കലും അല്ല... വഴിയിൽ കൂടെ പോവുന്ന മിന്നലിനെ പിടിച്ചെടുക്കുന്ന ഒരു സംഗതിയല്ല ലൈറ്റനിംഗ് അറസ്റ്റർ ..ഡയറക്ട് ഹിറ്റ് വരുന്ന കരണ്ട് മാത്രമേ അതില് പാസ് ചെയ്യൂ.
Inside wiring protection from lightning, Single phase Surge Protection Device is enough for single phase and three phase 3P SPD avail. An electrician can wired easily in main distribution board. For house external protection use earth spike in highest portion of roof and drop to earth connect in a copper earth plate
*_ഇത് ചെയ്തതിനു ശേഷവും വീട്ടിൽ ഉള്ളവർക്ക് ഇടിമിന്നൽ ഏൽക്കാൻ സാധ്യതയുണ്ടോ..!!?? വീട്ടിലെ ആളുകൾക്കും സുരക്ഷ കിട്ടുമോ..!!?? അതിനെ കുറിച്ച് ഒന്നും പറഞ്ഞു കേട്ടില്ല..!!_*