Purpose of the NEC [90.1, 2020 NEC] 

MikeHoltNEC
Подписаться 111 тыс.
Просмотров 10 тыс.
50% 1

This video is extracted from Mike Holt's 2020 Changes to the National Electrical Code Video Library, for more information visit www.MikeHolt.com/code​ or call 888.632.2633.
For almost 50 years, Mike Holt Enterprises has been providing quality electrical Code training to help electrical professionals learn the Code, prepare for exams, and improve their electrical knowledge. Visit www.MikeHolt.com​ for exam preparation tips and training, instructor and curriculum support, continuing education options, free videos and graphics, and so much more.

Опубликовано:

 

17 июл 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 17   
@ecospider5
@ecospider5 9 месяцев назад
Mike Holt recognizing the detail of his tie and correcting is a great example why he is so good at his job. Details details details.
@bruceangeloszek5303
@bruceangeloszek5303 Год назад
Ever since I started my journey in this industry "1997" Mike and his team made learning much easier to understand and make me more money than I thought I could ever make. Big thank you to Mike and team.
@MikeHoltNEC
@MikeHoltNEC 9 месяцев назад
You are most welcome.
@jorgeruiz3802
@jorgeruiz3802 Год назад
I will waiting to see the public input. Thanks for sharing this videos
@B81Mack
@B81Mack 5 месяцев назад
Very well stated.
@garbo8962
@garbo8962 9 месяцев назад
Wish the NEC would just make it mandatory to install a ground wire inside of every metal conduit, race way, trough , wire mold etc to provide a much more reliable ground. Too manner times I have seen EMT conduit without a ground wire pull out of a connector. Same thing with sealtite & greenfield. Have seen water leaking for awhile onto a conduit causing it to rust thru. In my area they stopped allowing inferior type AC ( YEA BX ) in most commercial buildings over 35 years ago. Have to use type MC cab!e. Last time that I did not run a ground wire in EMT or metal rigid conduit was probably 50 years ago. Better safe then dead.
@MikeHoltNEC
@MikeHoltNEC 9 месяцев назад
And your suggestion would serve no value. Please watch my video MikeHolt.com/Fundamentals. Then you'll understand.
@hornetd
@hornetd Год назад
IF you have legitimately used a larger conductor to compensate for voltage drop you can do several things that you already covered. My question is there such a thing as a Nationally Recognized Testing Laboratory listed and labeled wire gauge reducer which will provide the smaller diameter without compromising the connection?
@mastaplanna
@mastaplanna 8 месяцев назад
Did the "haircut" change get added to the 2023 code?
@MikeHoltNEC
@MikeHoltNEC 8 месяцев назад
No...
@ThobiasMarandu
@ThobiasMarandu 2 месяца назад
What if I am installing 3 LED Pole Lights which Needs Just NO 12 AWG and I Pulled Nu 8AWG What Scientific reason Yall Will Give me that it will affect the Wire, Plus You are Not Shaving the entire Length only less than an inch. I think Its Not Workmanship to shave wire but if its bigger than needed I don't see any Practical Problem.
@MikeHoltNEC
@MikeHoltNEC 2 месяца назад
What is your question?
@felipea1844
@felipea1844 6 месяцев назад
@ Mike, you and your team should create better visual aids to represent the term/s or concepts you are trying to explain. I'm a future electrician helper with dyslexia and dyscalculia. Thank you in advance.
@MikeHoltNEC
@MikeHoltNEC 6 месяцев назад
Please let me know of a video that provides better visual aids that explain NEC 90.1. Thanks.
@CC-jv3wm
@CC-jv3wm 9 месяцев назад
As far as we are concerned if the NEC genuinely cared they would GFI the entire service main.
@MikeHoltNEC
@MikeHoltNEC 9 месяцев назад
That is permitted (215.9), but nobody would be that stupid to turn off the power to the entire house because of a simple fault on a branch circuit.
@ecospider5
@ecospider5 9 месяцев назад
What if someone was revived 2 minutes after being electrocuted. They could be watching this video. 😋
Далее
Understanding System Voltages, NEC 2020, (46min:29sec)
46:29
How To Use The NEC, NEC 2020, (29min:15sec)
29:15
Просмотров 158 тыс.
УРА! Я КУПИЛ МЕЧТУ 😃
00:11
Просмотров 461 тыс.
Flo Rida - Whistle НА РУССКОМ 😂🔥
00:29
Просмотров 904 тыс.
AFCIs, Clearing Series and Parallel Arcing Fault
17:47
Multiwire Branch Circuit Done Wrong.
3:38
Просмотров 12 тыс.
Neutral at Switch Locations [404.2(C), 2020 NEC]
22:02
Dangers of Multiwire Circuits 28.6
11:40
Просмотров 7 тыс.
Condo Panel Upgrade - Simon Electric LLC
18:17
Просмотров 2,1 тыс.
УРА! Я КУПИЛ МЕЧТУ 😃
00:11
Просмотров 461 тыс.