OK I'm obsessed with testing batteries! Here's my latest find!
🛒 PZEM-015 Battery Tester DC Voltage Current Power Capacity Internal And External Resistance Meter bit.ly/Capacity...
🛒 PZEM-015 Battery Tester s.click.aliexp...
🛒110W / 60W Constant Current Electronic Load bit.ly/2CsVaI0
🛒 100W Constant Current Electronic Load s.click.aliexp...
🛒 UNI-T UT210E Clamp Meter bit.ly/UT210E_C...
🛒 UNI-T UT210E Clamp Meter s.click.aliexp...
Peacefair PZEM Volt/Amp meter enclosure www.thingivers...
🔗 Please tell me if any of the links provided no longer work!!
👀 Click Here to Subscribe bit.ly/1nformatica
🛠 I buy most of my gear from either bit.ly/_Banggood_ or s.click.aliexp... You can help me by using these links!
👍 Follow on Facebook / 1nformatica
💲 If you would like to buy me a coffee: www.paypal.me/...
DISCLAIMER: Unless otherwise stated all products shown in this video have been purchased personally. The description and video may contain links to products which might be affiliate links, so if you click on one of the product links I could receive a small commission. This does not affect the price you pay. If you do purchase through my affiliate link this will help fund future videos, thank you for your support!
#1nformatica

Опубликовано:

 

1 мар 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 29   
@PatricksDIY
@PatricksDIY 3 года назад
7:52 That is incorrect about it keeping a tally while the screen is off, it goes into a dormant stage. I tested this out on my solar set up reset all the timers, and waiting until the runtime was at 1 hour, then made note of the Ah used and runtime. When I turned the screen off I was at 1.2 Amp hours used after the hour of it being on. I Then turned off the screen, came back 2 hours later and all of the stats remained the same, with the exception of it updating the voltage of course, because that is dynamic update. I then reset all the Ah run time etc and did a test with the screen on. I had the starting point of 1.2Ah used, a runtime of 1 hour and so on. When I came back 2 hours later I was at 3.4Ah used and a run time of 3 hours. I reached out to the seller of this item to confirm because I was not expecting it to work this way, but they stated it is working as intended. I just wanted to put my experience out here. I have the same item with the exception that mine is 200v /300A. When you used your clamp meter to see if it "was still working" The power is sstill being moved though the shunt, the device does not "turn off the load" it just does not keep track of it while off.
@1nformatica
@1nformatica 3 года назад
Interesting! Thanks for sharing your experience. I will revisit this, as you can see in the video when I turn the display off the capacity is 552 mAh when I switch back on it flips over to 553 mAh. I will test for a longer period, maybe they have changed the firmware? Please consider subscribing if you have not done so already!
@62seadog
@62seadog 3 года назад
@@1nformatica My finding are the same as yours, meter held settings till the next time I checked,( 2 days later), maybe Patrick has a faulty unit.
@olivierjankovsky41
@olivierjankovsky41 3 года назад
@@1nformatica Hi, did you test it meanwhile? My device also did not messure anything if i switch of the display :-(
@1nformatica
@1nformatica 3 года назад
@@olivierjankovsky41 Yes, my bad! It does not update.
@diegomarteen
@diegomarteen 3 года назад
hello, great video, a question: is PZEM-015 capable of recort the peak value for the voltage and keep it memorized? I have to monitor a voltare regulator output for several hours and record the peak voltage. Thanks!
@gabrielquarshie94
@gabrielquarshie94 2 года назад
Very usefull info. BUT please how the device be wired between My solar system and battery bank. Next question is will the battery be connect to charger and still to the device ????
@1nformatica
@1nformatica 2 года назад
This device is designed to go between the battery and the load it is driving, it's really not for monitoring solar panel charging systems. Thanks for watching, have a great day!
@louispommel9257
@louispommel9257 3 года назад
Hi there, good review ! I have question though, if you had something that was charging the battery, would it show something like -30W and -1,2A ? letting you know what power is going into your battery.
@1nformatica
@1nformatica 3 года назад
A very good question! I have just setup a test. What happens is that the values do not go negative. They indicate the correct values but not the "direction" also the mAh still increase either way! Please consider subscribing if you have not done so already!
@sumeeths8423
@sumeeths8423 8 месяцев назад
Thanks @@1nformatica
@MCsCreations
@MCsCreations 3 года назад
Really interesting device, man! 😃 It can be really useful!!! Anyway, stay safe there with your family! 🖖😊
@1nformatica
@1nformatica 3 года назад
Thanks Mario, can never have enough toys! Keep safe!!
@freshersofbose456
@freshersofbose456 21 день назад
Bro does it shows the current in 2 direction. I mean . If fix it in my inverter battery side . Does is shows both charging and discharging current? Plz bro . Reply soon .very urgent 😢plz plz plz
@1nformatica
@1nformatica 21 день назад
A very good question! I have just setup a test. What happens is that the values do not go negative. They indicate the correct values but not the "direction" also the mAh still increase either way!
@tenapier
@tenapier 3 года назад
ILS... (I learned something) Well done! Thank you!
@1nformatica
@1nformatica 3 года назад
You're welcome! Please consider subscribing if you have not done so already!
@penncapt
@penncapt Год назад
can you install the shunt backwards. The battery end to the load end?
@1nformatica
@1nformatica Год назад
This device is designed to go between the battery and the load it is driving, it's really not for monitoring things like solar panel charging systems. Thanks for watching, have a great day!
@JM-cl2od
@JM-cl2od 2 года назад
curious how this is stacking up now its been a while? mainly i am wondering about the SOC calculation, as the manual says it is linear voltage calculation, for Lead etc this is fine, but not necessarily for lithium - eg my lifepo4 200AH barely drops any voltage until over 50% discharged
@1nformatica
@1nformatica 2 года назад
The SOC is only applicable to Lead Acid batteries. You could calclate the SOC roughly for your liFe batteries by monitoring the capacity used in discharge. Maybe consider some circuit to disconnect the batteries when the voltage falls below a safe level.
@abbii1661
@abbii1661 3 года назад
does it cut off automatically when reaching the cutoff voltage?
@1nformatica
@1nformatica 3 года назад
No. The "cutoff" voltage is only used to calibrate the state of charge SOC graph. RU-vid no longer shows me if you are subscribed. Please consider subscribing if you have not done so already!
@thirdly5509
@thirdly5509 2 года назад
Why mine shows 000 milliohm internal resistance?
@1nformatica
@1nformatica 2 года назад
Maybe you have a very good battery? Or the load and supply connections are reversed.
@seda14us
@seda14us 2 года назад
Thank you Boss...100% Best.
@1nformatica
@1nformatica 2 года назад
Hey thanks! RU-vid no longer shows me if you are subscribed. Please consider subscribing if you have not done so already!
@GeniusBarLiveMusic
@GeniusBarLiveMusic 3 года назад
good bit of kit
@1nformatica
@1nformatica 3 года назад
Yep! More toys for the boys!!
Далее
❌Ему повезло больше всех #story
00:41
Get 10 Mega Boxes OR 60 Starr Drops!!
01:39
Просмотров 12 млн
Better Battery Modding with your DIYed Meter
14:33
Просмотров 44 тыс.
Battery-Powered Magnetron
14:48
Просмотров 587 тыс.
PZEM-015 TESTER BATERII
17:41
Просмотров 10 тыс.
Как настроить Ваттметр PZEM 0 200
18:01
Cheap eBay battery monitor and shunt
5:53
Просмотров 40 тыс.
❌Ему повезло больше всех #story
00:41