Quoting for Electric Vehicle Charger Installation - How much should I charge? 

Artisan Electrics
Подписаться 250 тыс.
Просмотров 35 тыс.
50% 1

Quoting for Electric Vehicle Charger Installation - How much should I charge?
In this video I talk through the process of quoting for an Electric Vehicle Charging Installation and selecting which charger to install.
Products Used in this video:
Wera Meter Box Screwdriver (set): amzn.to/2ZTdGU6
Code of Practise for EV Charging: amzn.to/2XeIs89
MY ENERGY PROVIDER:
Bulb - Use this referral link and we will both receive £50! www.bulb.me/andrew8530
🏷️ DISCOUNT BUSINESS SUPPLIES 👇
➤ www.amazon.co.uk/tryAB/?tag=a...
-----TRADES INSURANCE DISCOUNT-----
If you need to renew your public liability insurance or need tools in van insurance, I recommend Rhino Trade Insurance, i've just renewed my insurance with them.
🏷️ Use My Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
➤ www.rhinotradeinsurance.com/quote
📞 or call 01162437904.
CAUTION: Never work on live electrical installations. If in doubt always seek the advice of a qualified electrician. This video is for entertainment purposes only please do not attempt to copy or recreate. Do so at your own risk.
✅ Check Out All Our Favourite Tools Here 👇
➤ www.amazon.co.uk/shop/artisan...
🔔 Subscribe to TOOLS4SPARKS RU-vid Channel 👇
I Also Have A Dedicated RU-vid Channel About Tools:
➤ / tools4sparks
-----TESLA REFERRAL CODE-----
🚀 You Can Use My Referral Link To Get 1,000 Free Supercharger Miles On A New Tesla 👇
➤ ts.la/andrew24855
DRIVE ELECTRIC:
If you're thinking of getting an electric car and going with leasing, contact Francesca at Drive Electric, if you tell her you came from Artisan Electrics she will look after you.
www.drive-electric.co.uk or email: francesca.decozar@drive-electric.co.uk
Use my referral code if you get a Tesla: andrew24855
✅ CHECKATRADE:
Get a £50 voucher when you join Checkatrade quoting our Member ID: 505219
join.checkatrade.com/friend
FREE STOCK SHARE worth up to £⁠100:
Create a Trading 212 Invest account using this link www.trading212.com/invite/FAtr and we both get a free share!
AMAZON DEALS:
Amazon Prime FREE for 30 Days:
www.amazon.co.uk/tryprimefree?...
FREE 30 day Membership to Amazon Prime Video is available here:
www.amazon.co.uk/gp/video/prim...
FREE Amazon Music UNLIMITED for 30 days here:
www.amazon.co.uk/gp/dmusic/pro...
FREE 30 Days Audible subscription here:
www.amazon.co.uk/Audible-Membe...
📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
📸 Artisan Electrics Instagram Account 👇
➤ / artisanelectrics
🐦 Artisan Electrics Twitter Account 👇
➤ / artelectrics
📓 Artisan Electrics Facebook Account 👇
➤ / artisanelectrics
This video is for entertainment purposes only please do not attempt to copy or recreate. Do so at your own risk.
#ElectricianLife #EVCharging #ArtisanElectrics
This video is for entertainment purposes only please do not attempt to copy or recreate. Do so at your own risk.

Наука

Опубликовано:

 

7 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 198   
@DanstheEngineer
@DanstheEngineer 4 года назад
I think this highlights how complex EV charge point installtions are. What seems very simple actually isn't. Firstly, if the client told me they want the cable hidden in shingle I would be asking them to dig 600mm deep with marker tape. Or suggest that the cable is clipped direct. It cannot be just hidden under the surface. I also wouldn't put the EV circuit on the RCD side of the board as any DC fault current could interfere with the type AC RCD despite the suggested charger having a built in Type A RCD. I believe a separate consumer unit should be installed dedicated for the EV as to not interfere at all with the existing installation. However this is where it opens up a can of worms. If you alter the tails to the existing consumer unit fir example henley blocks between the two boards, you will have to verify the existing installation. It starts getting a bit out of hand so when you have companies banging out two or three of these a day I wonder what they are actually doing.
@artisanelectrics
@artisanelectrics 4 года назад
Your totally right this is a great comment. Most people think it’s like putting in an outside socket but it’s much more complex than that and there’s no such thing as a “standard” install in my opinion as there are so many factors to take into consideration.
@DanstheEngineer
@DanstheEngineer 4 года назад
@@artisanelectrics yes mate! Definitely no such thing as standard and you have mentioned a couple of things the client has requested such as hiding the cable and potential for additional EV car in the future. Both things as an electrical contractor you should factor in instead of banging in a one size fits all service/product. But that is where is can be difficult because cost comes into play. Some of the EV charge point manufacturers cause a problem with poor install standards because they 'dictate' really poor unrealistic rates. Honestly, some manufacturers have hated me in the last because I would prove to them for a compliant installation, their rates do not allow for it in many cases.
@loosecannon5813
@loosecannon5813 4 года назад
Digging 600mm under that shingle would involve breaking the foundations which could extend 150mm out from the wall.
@VillainGang.
@VillainGang. 4 года назад
Why 2ft digging?? Sufficient depth by 18th is enough
@DanstheEngineer
@DanstheEngineer 4 года назад
@@loosecannon5813 exactly, don't do it.
@muzikman2008
@muzikman2008 4 года назад
Zappi!...all day long after your recent videos on EV and other YT clips Ive seen. No Earth rod is always a bonus.
@rattlehead85
@rattlehead85 4 года назад
I agree with your thinking Jordan. Question is is that consumer unit high integrity? which will allow you to juggle the MCB’s about so you can place one north of the two RCDs in service otherwise you may have Selectivity type issues going on between the cu rcd and the Zappi.
@muzikman2008
@muzikman2008 4 года назад
Looks like originally a TN-S supply but converted to TNCS by DNO?...
@MMG_MoonManGuitar
@MMG_MoonManGuitar 4 года назад
Love your insight into this!
@ArcanePath360
@ArcanePath360 4 года назад
Just get a solar panel hooked up. Job done :P
@Froggability
@Froggability 3 года назад
Whet are peeps doing for load shedding? If max demand pushes you over the supply limit?
@acelectricalsecurity
@acelectricalsecurity 4 года назад
rates vary from area to area but where i live i would expect to get £1350 plus vat, thats converting the existing board to accommodate a spare way on the main switch side.Adding separate boards for things just makes the installation cluttered.
@dynaman1600
@dynaman1600 4 года назад
Fitted Two EV points in two houses . Will be looking PV after lockdown. Are you going to the fully charged show when we get back to some kind of normal Justin.Great You Tube Podcast.
@artisanelectrics
@artisanelectrics 4 года назад
Thanks! Yeah I get free VIP tickets to fully charged live every year! Can't wait.
@chrisday8072
@chrisday8072 3 года назад
(Chris Day, Mayday Electrical) Thanks to your videos i have started to install the My Energi Zappie units
@artisanelectrics
@artisanelectrics 3 года назад
Excellent!
@mickelmcc
@mickelmcc 2 года назад
Can the cable be installed under the pebbles with a strip of 4mm stainless over it and then warning tape over that? Cost of the S/S is better than digging the required depth and if the customer is willing to pay a bit extra for it, I can’t see the issue. Any thoughts anyone
@kemots455
@kemots455 3 года назад
I have no issues with demand of charger just use it on economy7 at that time whole house load is around 100W
@paulmorrey733
@paulmorrey733 4 года назад
Thanks
@AlexWillmer
@AlexWillmer 4 года назад
Regarding the charger location, I wouldn't be too thrilled about the charge lead dangling across my front door when in use. On the other hand if for a single unit to reach both parking spots, it'll cross the front doorway no matter where you put it.
@eric4709
@eric4709 4 года назад
Would agree with that. For me that would preclude putting it on the LHS of the door way.
@ToddOvSheff
@ToddOvSheff 3 года назад
You could use a pedestal and some underground ducting to have it sat in the middle of the two. Not ideal situation and bumps the price up for a solution to your problem?
@timknapp2587
@timknapp2587 2 года назад
So you move the cat to the side with the charger on while charging. Swap places if they get another EV. Not rocket science
@terryselectricalservices8234
@terryselectricalservices8234 4 года назад
You love a ev install 😊
@chrislaing7153
@chrislaing7153 4 года назад
32a ring in the loft - that is one hell of a model railway layout!!! Can't be weed as it is the wrong side of the meter.
@artisanelectrics
@artisanelectrics 4 года назад
Actually it was weed... house used to be weed factory in the loft but got repossessed after police raid! haha
@Lewis_Standing
@Lewis_Standing 3 года назад
@@artisanelectrics "used to be"
@biaelectric9066
@biaelectric9066 2 года назад
5:00 - that was the old TN-S but they now use the “upgraded” PME.
@CosmosRays
@CosmosRays 4 года назад
I’m not an electrician so it may be obvious to others but having an interest in EV’s I have looked at Ed18 regs along with latest amendments. What I’m wondering is how you get past the regulations where it requires the actual charging unit to be isolated? The next question I have is to do with Earth rods, again may be obvious but I have extremely little knowledge in these areas but would like to understand what’s going on etc... What is the point of an earth rod if it is going into the same GND as the PME? Surely same Earth and if PME fault was to exist the earth rod isn’t actually going to do anything and RCD wouldn’t trip either? This is why I thought I’ve read in Ed18 that the actual charger has to be able to be isolated with some ‘unicorn device’ such as Matt:e SP-EVCP-T. Now I know some newer charger units have some built in fancy electrics but from my complete novice read of ED18 I read it as the actual charging unit had to get isolated (power into the charging unit itself) and that the actual charging unit self isolating is not sufficient or at least catered for in the regulations? As said I’m complete novice with no experience, I’ve done no more than read the regs to get an understanding so I’m more than happy to be educated by real experts.
@dermotcullen5263
@dermotcullen5263 4 года назад
Who else guessed Zappi at the start then?🤪
@cjmillsnun
@cjmillsnun 4 года назад
From the angle of that gas service entry into the meter box, it's PE. So no bond was required anyway.
@SME_Ste
@SME_Ste 4 года назад
Thinking this myself, age of property is a good clue too.
@Bin216
@Bin216 4 года назад
You can't suggest that they run the charging cable across the front door. It would be best if they park where your van is front of the gate to charge the car; it would also be on the correct side of the car of they reverse in.
@artisanelectrics
@artisanelectrics 4 года назад
Bryn Jones yeah good idea
@stuartcraigon2003
@stuartcraigon2003 4 года назад
Andersen charger Jordan?
@montythakur2682
@montythakur2682 3 года назад
How much the price for installation?
@matthewhantschar8408
@matthewhantschar8408 4 года назад
My old boss used to add up all the breakers and times by 0.4 for max demand.
@conorcummings21
@conorcummings21 4 года назад
You have to apply that to all but one, the largest one shouldnt be multipled also, ev charge points cannot be down graded when working out maximum demand
@MrAustin241080
@MrAustin241080 4 года назад
Why is the outlet standpipe for the washing machine tight against the consumer unit hate to be there if that pipe ever gets blocked and backflows in to the consumer unit. Surely it is a strict no no?
@MorzakEV
@MorzakEV 4 года назад
I would probably make a note of it on the certificate, but it would be up to the customer to rectify.
@jamescameron5472
@jamescameron5472 2 года назад
I noticed that too .... what was the plumber thinking?
@ianlocke6125
@ianlocke6125 4 года назад
Separate CU is the way to go unless you change the existing RCD for a type A as the AC ones may be saturated by any DC leakage.
@acelectricalsecurity
@acelectricalsecurity 4 года назад
How would that affect the existing RCD, they won't trip with DC leakage current, and the zappi has built in type A RCD protection.
@ianlocke6125
@ianlocke6125 4 года назад
@@acelectricalsecurity If the EV equipment is producing some residual DC fault across phase and neutral - even if not enough current to trip the Type A in the Zappi, this current could blind the upstream type AC and render it inoperative should a fault occur on one of the other circuits it protects - Extract from IET Website - What are the effects of DC residual fault current on RCDs? To help explain, it might be worth thinking about some older models of earth fault loop impedance testers, which could cause the RCD to operate unintentionally. To prevent this, some types of earth fault loop impedance testers imposed a DC current on the AC test current. This DC current saturated the magnetic core of the RCD preventing it from tripping under the test condition. Where equipment produces an element of residual DC, for example, variable-speed drives is connected to the electrical installation, the DC component can saturate the magnetic core and effectively blind or locks the RCD. This is known as ‘blinding’ and could either prevent the RCD from operating or reduce the sensitivity resulting in a dangerous situation. That's where I'm coming from unless I'm interpreting it wrongly?
@craigbutler6243
@craigbutler6243 2 года назад
@@ianlocke6125 a bit late in the day responding to your comment above Ian, but thats 10 out of 10 mate
@nicholaspratt7934
@nicholaspratt7934 4 года назад
Is the concrete gatepost not bolted to the wall, maybe leaving a route under it.
@artisanelectrics
@artisanelectrics 4 года назад
Possibly I will have to check but think I’m gonna clip direct anyway for regs
@CarlosArruda77
@CarlosArruda77 3 года назад
Why would you say PME earth system? I mean that's what I too learnt at college that a TNCS is the same as PME. Having said that, I have called the dno once and reported it as PME and once the lads were onsite they said it wasn't. They said a TNCS is not a PME unless there's a sticker saying PME. I was surprised. Keep them videos coming please and thank you.
@anthonybragg
@anthonybragg 4 года назад
I would just take the cover off just to check there is nothing in that marked spare. Could you not change the RCD to a 100A RCD and put in the appropriate MCB as you should be able to get them for that Control Gear consumer unit?
@stuartcraigon2003
@stuartcraigon2003 4 года назад
Its switched on so I'm not convinced its spare at all.
@philip426
@philip426 4 года назад
There are quite a few national companies that install Zappi with 10m of SWA cable for £750 after the OLEV grant has been taken off. They must have a good deal going on with My Energi as i can't get the Zappi, Hub & Harvi for less than £900 & that's being Zappi approved.
@artisanelectrics
@artisanelectrics 4 года назад
Yeah I don't know how those companies do it, they must be either cutting corners or running at a loss in my opinion.
@vwes
@vwes 2 года назад
@@artisanelectrics Efixx had an interesting video on this. It appears the rate stated on some national sites is a "Starting at" rate and then further in the websites they state whats included (or not as becomes all too apparent).
@niallgilmore2411
@niallgilmore2411 4 года назад
Should the gas bond not be within 300mm of entering the building?
@alhughes9698
@alhughes9698 4 года назад
where practicable, within 600mm of the meter outlet union or point of entry to the building if the meter is external. (Source, Electricians guide to the building regs page 47) So realistically that bond should have been installed in a different position but seeing it as it is wouldn't keep me up at night.
@niallgilmore2411
@niallgilmore2411 4 года назад
Ahhh you're right it's 600mm. In this case would that be a fail as it's at the boiler? Not that it's anything to do with artisan himself
@alhughes9698
@alhughes9698 4 года назад
@@niallgilmore2411 If i saw that gas bond in an EICR situation i'd probs just give it a C3 so overall the installation wouldn't fail from that defect, some guys might code it C2 some might not code it at all but i wouldn't see it as potentially dangerous as the safety connection is there its just slightly in the wrong place
@MrTobex21
@MrTobex21 3 года назад
What about wallbox? Is it same as zappi in price and quality?
@xxwookey
@xxwookey 2 года назад
Slightly different functionality, but physically much smaller. Better attitude to doing your own control with OCPP, but still not really open. I think both companies do all their own design and build in the EU.
@havocgeneral
@havocgeneral 4 года назад
I took advantage of the free charging point when I purchased my EV which was a BP ChargeMaster box and requires an earth electrode. The electrician they sent to install it just drilled a hole through the block paving and whacked in an massive earth rod, I did wonder how he checked there was nothing below, I guess he got lucky. How deep are gas/water/electricity mains typically buried? I assume that even if they are “typically” a certain depth there are always exceptions.
@artisanelectrics
@artisanelectrics 4 года назад
Yeah that sounds quite risky to me. I always use a cat scanner if I really have to put an earth electrode in.
@sbmorris2k6
@sbmorris2k6 4 года назад
Cat scanner would be useful in these situations used for finding underground cables and pipes 👍
@SME_Ste
@SME_Ste 4 года назад
Thats why the installation was free, the electrician who completed it didn’t give a toss
@cjmillsnun
@cjmillsnun 4 года назад
@@SME_Ste He would've given a toss if he hit a service cable/pipe.
@paulhayles6947
@paulhayles6947 4 года назад
Driving earth rods is always anxiety provoking for me. If you hit the mains service cable you are in for a world of pain. A fellow sparks drove one (without knowing) into an old porcelain sewage main on a military base and knew nothing till the inevitable happened. He got to know what he did when he was sent a still black & white photo from the drainage CCTV camera. The pipe had backed up within a few weeks.
@UkSkin
@UkSkin 3 года назад
Didn't it freak you out that someone had copied your house inside and out exactly?
@jamesallen21
@jamesallen21 4 года назад
Probably originally a TN-S system then Outer sheath failed so they've changed to a TN-C-S maybe? Great Video
@sbusweb
@sbusweb 4 года назад
+James Allen I can see that... but this doesn't explain the Outer sheath being *completely* disconnected, I would surely expect it to be bonded/connected, what do you think ??
@marshallelectricalservices2986
@marshallelectricalservices2986 4 года назад
Agreed James.
@SME_Ste
@SME_Ste 4 года назад
Usually if the supply is PME the DNO like to plaster the cutout with warning labels. I know what i’d be doing to check,😉😉
@dudleyguy42
@dudleyguy42 4 года назад
Looks like service head as been replaced which was originally TNS and they upgraded supply to TNCS whilst they were at it.
@artisanelectrics
@artisanelectrics 4 года назад
dudleyguy42 Nice thanks
@cjmillsnun
@cjmillsnun 4 года назад
@R-77 It's probably earthed at the other end. Though this should be tested.
@crismacpherson1549
@crismacpherson1549 4 года назад
£1250 plus vat. Are you going to tell us your price? Do you not fit surge protection when you do EV sockets? When I did my EV course, the lecturer said that you should provide Surge protection
@take-a-hikke
@take-a-hikke 7 месяцев назад
Is that price including charger
@brad30
@brad30 4 года назад
The Rolec Smart chargers do have a type A RCD fitted.
@artisanelectrics
@artisanelectrics 4 года назад
Brad ah ok that’s new I missed that
@MorzakEV
@MorzakEV 4 года назад
Hi Brad, are you sure. All the one's I've purchased are supplied with a type A RCD, but they have to go in a separate consumer unit which is also supplied.
@brad30
@brad30 4 года назад
@@MorzakEV Yes, you are right. The newer models (smart) Rolec chargers have separate RCD, its the older models that have a type A RCD fitted. 👍
@artisanelectrics
@artisanelectrics 4 года назад
Yeah that’s what I thought
@MorzakEV
@MorzakEV 4 года назад
@@brad30 Cheers. I thought i was being given some obsolete version by my distributor for a second! 😂
@owrang9756
@owrang9756 2 года назад
For ev charging does the RCD have to be type B?
@sfmelectrical
@sfmelectrical 2 года назад
Type A
@emsservices6090
@emsservices6090 4 года назад
ok, so what's in the CEF box at 3:32 when you open the gate and quickly kick it away then !..... is this a job you have already got and are about to do ?
@dg2908
@dg2908 4 года назад
pretty sure that box belongs to the tenant and isn't necessarily connected with the charging point
@pault4793
@pault4793 4 года назад
well spotted ,he most probably has got the job , but wants to see whether hes fucked up price, cant blame him we never stop learning
@artisanelectrics
@artisanelectrics 4 года назад
You will find out more soon! Watch this space...
@Fishbait075
@Fishbait075 4 года назад
Hello Mr Sunburn!!!
@artisanelectrics
@artisanelectrics 4 года назад
😂
@nigellewis4686
@nigellewis4686 4 года назад
Can it be wired to a commando plug so if client move house he can take it with him
@artisanelectrics
@artisanelectrics 4 года назад
Nigel Lewis no definitely not allowed
@masonchapman148
@masonchapman148 4 года назад
How come these exist then Jordan? Seems like a 3KW charger straight from a commando to me. evconnectors.com/EV-Portable-Mode-2-16A-J1772-EVSE-16A-COMMANDO-Plug
@kittsdiy
@kittsdiy 4 года назад
@@masonchapman148 my friend has something simular ( little bigger ) in his frunk of model S .. every where he finds a Red socked .. he plugs in :-)
@masonchapman148
@masonchapman148 4 года назад
Indeed. They also make 32A single phase one for 7KW chargers... Two discreet 32A commandos seems like a Stella Soloution to the 'two places' charging issue.
@nigellewis4686
@nigellewis4686 4 года назад
Looking like is upto his max demand so second phase
@stuartcraigon2003
@stuartcraigon2003 4 года назад
6:32 in and I'm already thinking an IP rated adaptable box external to the meter box with a CU supplied from a Henley block in the meter box. Your on the right lines with the pea shingle I think Jordan but I will keep watching and see what happens.
@Mainly_Electrical
@Mainly_Electrical 4 года назад
Definitely the way to go
@acelectricalsecurity
@acelectricalsecurity 4 года назад
Interesting, the out going tails and incoming tails are the opposite way around. If your using a zappi you won't need to worry about the max demand as they ramp up and down. Looks like a mixture of earthing systems, but to be honest nowadays it's all pme no matter what you actually see at the head.
@brad30
@brad30 4 года назад
What about if it's a TT?
@acelectricalsecurity
@acelectricalsecurity 4 года назад
@@brad30 when the earth is provided by the electric supplier
@paulneary703
@paulneary703 3 года назад
Why doesn’t everyone use a zappi for every job , curious as to why even bother looking at other charge points, if this de rates demand as and when it needs to, plus it’s protected by type A RCD
@acelectricalsecurity
@acelectricalsecurity 3 года назад
@@paulneary703 your right, and if I were asked to install a charger that's the one I would go for, but on the other hand there's always people that are just cost focused, and will always go out install the cheapest product it there, regardless of the positives they offer
@paulneary703
@paulneary703 3 года назад
also do we know if the DNO are informed pre Installation? if works have to be carried out and new board installed how are installers doing this if there is no isolation at the Main fuse, getting the DNO out to carry out works would take an age and slow up all the jobs, or are installers cutting the network operators tags and removing 100A fuse themselves???
@BP-td5gv
@BP-td5gv 4 года назад
Can’t wait for the test Centers to re open so I can do my 2391
@rocketretro7200
@rocketretro7200 2 года назад
It looks like the EV grant of £350 is the cream on top of the EV fit cost for an installer, happy days for them, not so for the consumer.
@ashmanelectricalservices4318
@ashmanelectricalservices4318 4 года назад
Without knowing what fixed equipment is connected to the installation, I can't give you a maximum demand 🤷‍♂️
@chucky1077
@chucky1077 4 года назад
Leaving a clamp meter with a min max setting connected to the one of the tails for a few days. Could give you a good indication.
@huyongquan6554
@huyongquan6554 4 года назад
For me, would like to quote round about £650 plus vat except EV charging equipment.
@meganstokes08
@meganstokes08 4 года назад
Don't forget Sun cream on your nose 😄
@titmando1199
@titmando1199 4 года назад
Hi, Jordan what are you thoughts on Lay-Z Spa hot tubs?, I'm seeing a lot of people installing them on outside sockets that are being installed by "erectricians" these outside sockets are being run off a ring in the house and are plugged into a socket outlet and they cost the customer £55 to install. There are so many risks involved with this because the customers are going to run other stuff off these outside sockets and potentially upgrade the hot tubs and no account for the diversity of the circuits are considered seems a lot of people are racing each other to the bottom, washing their hands and walking away.
@anthonyridgley1819
@anthonyridgley1819 4 года назад
I asked chris the same question... i watch these channels not to do any work mainly coz i do want to go for a corse but just not got the brains lol.. i recently got a lazy spa hot tub (for the wife) n at min its plugged in to the kitchen with window being open, i rang a few electricians to do an outdoor socket, they gave me quotes all stating around the 60 pound mark. 1 said they was going to take it from a fused spur that was an old fan in the kitchen. One said they was gonna spur it from a socket n one said do a 16amp rcd n from the CU. now out of all 3 i would say the last one but what are the recommendations for this coz surely you cant spur it if the ring can you ??? Btw im nit doinv it myself as knowing me ill do it wronv but also i dont think the landlord will be happy if i did it n fucked everything up haha
@robswingler
@robswingler 4 года назад
Anthony Ridgley A lay-z spa has a max load of 2kw which is just over 8amps and is thermostatically controlled . Wouldn’t see a problem spurring off a ring finale personally.
@lawrencegakure116
@lawrencegakure116 4 года назад
@@robswingler however , with a pump, you should allow startup current. Unfortunately, many of those rings are not correctly installed or broken.
@LauGar69
@LauGar69 3 года назад
Seems you never answered, what would you have charged if this was not your house and a paying customer ? All those comments about how people’s quotes are too expensive, please please stop racing to the bottom (I do understand about different areas of the country though) however, how long have we had to train? Ever filled out a OLEV document? Travelling to suppliers? First quoting visit? Full EIC to be provided etc etc perfect example is the current EICR joke, largest estate agent group in the country offering £75 inc VAT and want 3/day minimum.
@jamiemarsh7439
@jamiemarsh7439 4 года назад
£900 for zappi and hub, MCB, glands, cleats and swa ect £60 and £250 labour + vat - OLEV grant
@whitbreadz
@whitbreadz 3 года назад
Maximum demand is what annoys me most about EV charging. Calculate it as much as you want, however you want - 100% of largest and 40% of remainder, or diversify cooker circuit and 1x ring then 40% of remainder and 66% rule for lighting adjusted for a more modest 20watt per lamp holder per fitting. Where I am SSE want the max demand WITHOUT diversity. The total of all MCBs added together. So it’s almost impossible for someone to have one with a service upgrade around my way. And then I find customers getting annoyed with me as a contractor that they can’t have one without an upgrade when some of their neighbours do.
@Mmmjustme
@Mmmjustme 4 года назад
£350 plus vat for labour. Effectively paid for by HMRC 😂
@rickybeans8504
@rickybeans8504 4 года назад
We talkinng £500 proffitt an install?
@stuartwilliams8315
@stuartwilliams8315 4 года назад
looking at the cost of a zappi at around £900 plus labour be at the £1300 i think with materials
@artisanelectrics
@artisanelectrics 4 года назад
Stuart Williams thanks
@paulaldous6410
@paulaldous6410 4 года назад
Hi , Supply a zappi & Materials - the £350 grant. Total £ 810 including the vat 👍
@artisanelectrics
@artisanelectrics 4 года назад
Wow that’s cheap!
@kittsdiy
@kittsdiy 4 года назад
that looks to me like a faire price ..
@SME_Ste
@SME_Ste 4 года назад
Paul Aldous christ mate, is your calculator bust?
@tuboid001
@tuboid001 4 года назад
The Zappi and the Hub come to £723 alone!
@starseed5275
@starseed5275 3 года назад
Plumbers don't work for nothing but electricians do.. Put your prices up and stop destroying the trade
@lukemason4883
@lukemason4883 4 года назад
That consumer unit looks very familiar 🤔
@artisanelectrics
@artisanelectrics 4 года назад
🤫
@benbradbury3665
@benbradbury3665 3 года назад
I thought the same..
@fredstarkey3425
@fredstarkey3425 4 года назад
Why are you quoting for your own house? Hahaha
@theodorenelson9509
@theodorenelson9509 2 года назад
Will you come to London to do a job?
@RWATraineeElectrician
@RWATraineeElectrician 4 года назад
I didn't realise that you could use other chargers with a tesla?
@artisanelectrics
@artisanelectrics 4 года назад
Yeah you can use any charger with any vehicle as long as the socket is correct.
@p00pipe
@p00pipe 4 года назад
@ on domestic install?
@MorzakEV
@MorzakEV 4 года назад
This is a real common misconception. In all honesty, the Tesla wall charger is a bit rubbish - it has no 6ma DC protection so an expensive type B RCD is required, and it is a dumb charger so you cannot set the charger to work when electricity rates are lower costing. People seem to be under the impression that it works better with teslas than other charge points but the opposite is actually true!
@StJamesChurchMangotsfield
@StJamesChurchMangotsfield 3 года назад
Not sure I like the ida of a cable running across the main doorway of the building, that really is a trip hazard.
@nigellewis4686
@nigellewis4686 4 года назад
I don't know how long the flex is on the zapi put it would look good hidden behind the gate I see the unit price is about £600 I'm not an electrition so I will guess about £1500
@kittsdiy
@kittsdiy 4 года назад
700 pound for some cable & braker & some labour .. is not cheap.. but it depends on situation ..cable length .. and how long you work on it .. full day work + cable & supplies .. i guess UK Electrician is also much more expensive then Belgium ..
@stevebeal73
@stevebeal73 3 года назад
Looks like the lady of the house is keeping the detergent measuring scoop on top of the CU ...
@crismacpherson1549
@crismacpherson1549 4 года назад
What was your price for this installation?
@artisanelectrics
@artisanelectrics 4 года назад
I did it for free... you will find out why soon.
@crismacpherson1549
@crismacpherson1549 4 года назад
Artisan Electrics you don’t own a nice new white Tesla by any chance??!!😁
@kinross24
@kinross24 3 года назад
That’s your house ! Cheeky
@neilbridgeman7768
@neilbridgeman7768 4 года назад
One days work for two IMO. I would cut the tails and install an IP67 rated box next the the meter box with a small DB inside. Shingle is not wide nor deep enough so would clip direct. £1975 + VAT - £350 OLEV = £1675 + VAT
@artisanelectrics
@artisanelectrics 4 года назад
Thanks! I did the job this afternoon by myself took me 4 hours
@neilbridgeman7768
@neilbridgeman7768 4 года назад
@@artisanelectrics Smashed it... How was my price guess?
@iknowmyfootball3901
@iknowmyfootball3901 4 года назад
6.00mm 2.5mm CPC on the cooker?
@artisanelectrics
@artisanelectrics 4 года назад
Yeah why?
@Cumbrianbushcraft
@Cumbrianbushcraft 4 года назад
That’s what 6mm cpc is 2.5 mm
@artisanelectrics
@artisanelectrics 4 года назад
Cumbrianbushcraft yes that’s correct. Why do you mention that?
@dhkelectrical2308
@dhkelectrical2308 4 года назад
😂
@olec8978
@olec8978 4 года назад
2.5mm 1.5mm CPC on the ring circuits? This place just keeps on surprising us
@wilfgrant2945
@wilfgrant2945 3 года назад
£199.00 all in and give back 151 from the grant
@nigellewis4686
@nigellewis4686 4 года назад
399 from Toolstation
@artisanelectrics
@artisanelectrics 4 года назад
😂
@nigellewis4686
@nigellewis4686 4 года назад
Would be so much easier if charger is built into the car then all is neaded is a normal out door socket
@kittsdiy
@kittsdiy 4 года назад
@@nigellewis4686 in a Tesla the charger is build in .. those wall chargers are just the electronics to negociate with the car how much current it can take :-)
@cjmillsnun
@cjmillsnun 4 года назад
@@nigellewis4686 The charger is actually in the car. However the safety systems are in the point.
@APlusES
@APlusES 4 года назад
I would charge around £1200 after Olev discount 👍🏻
@onthego2004
@onthego2004 3 года назад
Ok, we all know this is your house now. How much labour would you have charged? Just labour not making on materials.
@StephenBoyd21
@StephenBoyd21 3 года назад
Oh you card, I watched the videos in the wrong sequence 😃
@stuartwilliams8315
@stuartwilliams8315 4 года назад
plus vat
@ryancalderwoodnelson2411
@ryancalderwoodnelson2411 4 года назад
£1100 for install plus your hourly rate and a bit extra😉
@ulvielive9597
@ulvielive9597 4 года назад
I am frankly astonished at these prices, I have just been gathering quotes for a basic install, excluding the Zappi 10m of SWA plus 3 hours labour and a test cert came to £100 , how much per hour labour are you all charging ??? It looks like you are all enjoying the OLEV feeding frenzy - hang your heads in shame - looks like Paul Aldous is the only decent bloke here.
@Thegardener87
@Thegardener87 3 года назад
I don't know any electrician that would do 3 hours of any electrical work for less than £100. It takes a lot of training, experience and running costs to be a competent electrician. You'd be lucky to get a sparks for less than £50 an hour in or around London. You're paying for someone to undertake safe and thorough work. Someone that chucks an EV charging point on a wall for £100 and walks away probably isn't doing it properly.
@CarFinanceSimplified
@CarFinanceSimplified 3 года назад
I’ve just priced up all the bits I would need, including a PEN device and 25m of 10mm SWA (as I want some extra capacity down the line) and it’s about £550 including an Ohme smart charging cable. That’s for all bits for the meter split, new consumer unit in the garage and all other bits. So £750 all in perhaps?
@chrisdavies6633
@chrisdavies6633 3 года назад
£1450 +vat
@paul_my_plumbs_uk
@paul_my_plumbs_uk 4 года назад
All the BSHT training and money for what is effectively an outside charging socket 🙄🙄🙄
@leonblittle226
@leonblittle226 4 года назад
Class example of how under prepared and badly thought out (ie not at all) this electric car revolution will be for the UK and these are the people who have driveways!
@artisanelectrics
@artisanelectrics 4 года назад
Yeah it’s gonna take some working out but today I did the install and it went smoothly with the Zappi!
@barryturner1146
@barryturner1146 3 года назад
10000
@evguysltdianlawrie2274
@evguysltdianlawrie2274 4 года назад
£1240
@artisanelectrics
@artisanelectrics 4 года назад
IWL Electrical Limited Ian Lawrie Nice
@twasb2000
@twasb2000 3 года назад
Is that complete including zappi and hub?
@muicsboxsreview2214
@muicsboxsreview2214 2 года назад
Hi mate how are u OK mate keep up the good work on here mate keep up the good work work on here mate keep up the good work on here mate hove a good day mate form Greg bouchard u do a raelly good job on here mate keep up the good work on here mate form Greg bouchard
@chriscain7463
@chriscain7463 4 года назад
Pretty sure that's your house......
@artisanelectrics
@artisanelectrics 4 года назад
Yes! 👏
@muzikman2008
@muzikman2008 4 года назад
If they can afford a Tesla, they can afford a price of £4k install :-)
@barryturner1146
@barryturner1146 3 года назад
10000
Далее
Installing my own Electric Vehicle Charger
33:32
Просмотров 242 тыс.
Мой инстаграм: v1.ann
00:13
Просмотров 117 тыс.
google callout in Detling
1:13
Просмотров 31
EV Charger Installation UK - No Earth Rod Needed!
41:52
EO Mini Pro Car Charger Installation UK
17:24
Просмотров 43 тыс.
Новые iPhone 16 и 16 Pro Max
0:42
Просмотров 2,4 млн
КАКОЙ SAMSUNG КУПИТЬ В 2024 ГОДУ
14:59