Тёмный

Really Odd Thing Happened to Me On This One!  

HVAC GUY
Подписаться 62 тыс.
Просмотров 44 тыс.
50% 1

In this video I visit a customer who’s heat pump wasn’t working. #hvacguy #hvaclife #hvactechnician #airconditioner #furnace #hvac #hvactrainingvideos #heatpump #hvacinstall #hvactroubleshooting #electrician #shocked ‪@ruud‬
Merch Store : hvac-guy-2.creator-spring.com
HVAC LIFE FB Group: / 521086622906115
Here are links to the tools I use, And it costs you nothing extra to buy from this list:
Appion AV760: amzn.to/3OkrwHC
Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
Fildpiece SVG3 Vacuum Gauge: amzn.to/3udursu
Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
Fieldpiece Blutooth Scale: amzn.to/3Gzveab
Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
Fieldpiece MR45 Recovery Machine: amzn.to/3cUFX5h
Fieldpiece 8CFM VP87 Vacuum Pump: amzn.to/3qC2wA2
Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
Milwaukee M12 Impact Driver: amzn.to/37xXkqk
Makita XDT16: amzn.to/3riXuaJ
Makita 18V Light: amzn.to/3Fw4GW4
Makita Wet/Dry Vacuum : amzn.to/3tw4dAL
Makita Jobsite Radio: amzn.to/3HuVp2u
DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
Klein Knee Pad: amzn.to/3cy6FB0
Klein 7in1 Flip Socket: amzn.to/3bpabwG
Klein Journeyman Pliers: amzn.to/3tvB60w
Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
Milwaukee Tool Box: amzn.to/322iyK9
Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
Milwaukee Hook Blade Knife: amzn.to/33F3m5T
Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
Western Nitrogen Regulator: amzn.to/3rmdKrx
Klein Canvas Bucket: amzn.to/3FyzKVf
Flag Velcro Patch Kit: amzn.to/3K8Eswx
Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
Milwaukee Magnetic Light: amzn.to/3FulCfF
Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
SS2 Float Switch: amzn.to/3K7LJMW
3-Amp Breaker: amzn.to/3nxaSXJ
Appion Valve Core Removal Tool: amzn.to/33CFArw
Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
Similar Small Tubing Bender: amzn.to/3fJsziJ
Fluke Twist Guard Test Leads: amzn.to/3216R6j
Fluke 975 Air Meter: amzn.to/3GwD9oM
Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
Quick Check Acid Test: amzn.to/3GA2XAy
Aims Power Inverter: amzn.to/3qOSc87
Wiha Torqe Screwdriver : amzn.to/3u1swH6
Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
American Flag Gator : amzn.to/3rKBl5u
Compressor Tote: amzn.to/3H8xHst
Inspection Mirror: amzn.to/3r9PERV
Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Опубликовано:

 

8 фев 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 126   
@Bryan-Hensley
@Bryan-Hensley 5 месяцев назад
There was a HVAC guy killed in our neighbor town about ten years ago because of this exact same thing. I used to think about the unit being "live" but I've gotten casual lately. This is a wake up reminder..
@davidca96
@davidca96 5 месяцев назад
I do work on CATV transmission lines, one time working on underground lines we had dug a hole and kept getting shocked by the dirt itself in the hole, enough to hurt like here but not enough to harm us thankfully. Turned out to be a street lamp nearby its wiring was energizing the ground itself, never expected it or ever ran into it again so far. You do this stuff long enough you run into all kinds of oddball situations, glad you werent hurt Curtis.
@HVACGUY
@HVACGUY 5 месяцев назад
Me too
@jimmy8653
@jimmy8653 5 месяцев назад
Cheaper to buy a unit they spent to much money lol
@bobboscarato1313
@bobboscarato1313 5 месяцев назад
@@jimmy8653 they may not have the money or are credit-worthy to buy a new system.- As along as Curtis is around, he'll keep unit going.- He doesn't have to give any extended warranties either!
@MariosACandRefrigeration
@MariosACandRefrigeration 5 месяцев назад
That is why we touch equipment with the back of the hand,and disconects should not be behind condensers.2 cents.
@bobboscarato1313
@bobboscarato1313 5 месяцев назад
Out in the country you can find all kinds of jobs.-
@billbrown1476
@billbrown1476 5 месяцев назад
I loved how you repaired the insulation by mounting sheet metal to hold it in place.
@HVACGUY
@HVACGUY 5 месяцев назад
Best way to do it.
@repetemyname842
@repetemyname842 5 месяцев назад
Curtis, you have a gift for turning a sows ear into a silk purse, your customers must be some happy people.
@mxslick50
@mxslick50 5 месяцев назад
That loose insulation looked like it was touching one of the hi limit cutouts. That was what most likely caused your shock. It would have also given you that resistance reading you got when testing the load side on the contactor. EDIT: Nevermind, commented before you found it on the dead motor.
@jimdarhower4945
@jimdarhower4945 5 месяцев назад
How did he get shocked though? How did he complete the circuit so to speak.
@mxslick50
@mxslick50 5 месяцев назад
@@jimdarhower4945 (Bear with the length of this answer, but it is a complex thing to fully explain.) The grounding of the unit might have been a bit weak, but the main reason is that electricity will take ALL available paths back to it's *source* (one path of which is through ground and/or neutral, and since Neutral is not present here, ground is the only other path.) How much of the current takes each path depends on the electrical resistance, and in this case Curtis, in contact with damp soil, made a path good enough to flow some of that current. There are videos on this topic that you can search for to get a more complete explanation.
@Losi5t20
@Losi5t20 5 месяцев назад
S''j*jxv;&hhhhh*j*
@jimdarhower4945
@jimdarhower4945 5 месяцев назад
@mxslick50 - that makes sense. Appreciate the reply.
@bobboscarato1313
@bobboscarato1313 5 месяцев назад
@@jimdarhower4945 I also seen the pulled liner sucked into the blower and causing the unit to ice up! Mostly on convenience-store rooftop units!
@user-ns3fl1tu4q
@user-ns3fl1tu4q 5 месяцев назад
There is most definitely an open somewhere in the grounding circuit of that system. What you experienced could have been a lot worse if your body would have been grounded more than it was. You might consider checking that out further or recommend an electrician get involved if you would rather not mess with it. PHEW!!
@johnathandye5244
@johnathandye5244 4 месяца назад
This does not happen often, usually the breaker will trip when you have a bad motor, that was a good explanation of the electrical issue though in the other comment. However I just wanted to say you offer quality service and care about fixing things the right way. Nice to see, this is coming from someone in the feild for 20+ years and I work on anything from 1 ton mini split to 1500 ton centrifugal chillers. Job well done my man.
@Paulie1232
@Paulie1232 5 месяцев назад
I thought you were going to say the lady of the house 🏠 came out naked when you were working on the unit, lol...😅
@549BR
@549BR 5 месяцев назад
I thought maybe an unclothed woman with coffee and donuts greeted Curtis; well, you said it was something that shouldn't happen, didn't you? Just a little levity for the end of the week.😎
@jthonn
@jthonn 5 месяцев назад
I thought the same thing at first. At least another underwear shot, lol.
@Bryan-Hensley
@Bryan-Hensley 5 месяцев назад
He was definitely shocked when she showed up.
@MetaphysicalEngineer
@MetaphysicalEngineer 5 месяцев назад
I recoiled instinctively when you got zapped, even though I knew it was coming! So glad you weren't hit harder! Had a kitchen exhaust fan almost get me like that. Just got a tingle, and thought to check with my meter. Found entire fan chassis energized at 120V because a wire had chafed through. Some genius had stopped the breaker tripping by unhooking the ground wire at the panel! Bonus points for no disconnect on the roof and each leg coming from a breaker in a different panel.
@tellmesomething2go
@tellmesomething2go 4 месяца назад
had a 220 almost get me, between a roof-top, and the trans. was a good jolt.
@dblungm
@dblungm 5 месяцев назад
Nice job Curtis, I was in HVAC for 36 years and still baffled by the lack of use of anti seize compound on motor shafts. Just makes it easier next time 👍
@CommercialGasEngineerVideos
@CommercialGasEngineerVideos 5 месяцев назад
Nice to see people good at their job caught on film
@38mullet
@38mullet 5 месяцев назад
if you have proper ground wire shouldnt happen
@jthonn
@jthonn 5 месяцев назад
You are right, but I have seen some crazy wiring.
@Bob.W.
@Bob.W. 5 месяцев назад
Do you mean an equipment grounding conductor? I think current could be running on the EGC and the breaker would not trip. Seen that happen before.
@jthonn
@jthonn 5 месяцев назад
Exactly@@Bob.W.
@jimharmon3404
@jimharmon3404 5 месяцев назад
Well Curtis the frame and cabinet is not a ground in and of itself. It has to be grounded by way of the AC supply. There must be a ground bond at the Main circuit breaker panel only. For you to get shocked there has to be two faults, one looks like it is the insulation blanket falling onto an exposed heater connection making the cabinet hot. The second fault is in the ground system where the ground conductor is open between the Air Conditioner and the Main Circuit panel in the house. That too must connect to earth ground on the utility pole which may be faulty creating a shock hazard for the entire house. You should report that to the utility to have them check that out ASAP.
@gor312
@gor312 5 месяцев назад
Not the utility pole. The ground connection is normally done where the service enters the house, either with a grounding rod or a Ufer ground (rebar in concrete). Either this connection has failed (very dangerous but unlikely), or, more likely, the unit itself was never connected to safety ground by the installer.
@boomer9900
@boomer9900 5 месяцев назад
There is a break in the grounding somewhere in the unit, house, pole. The owner should call an electrician and have it checked out because if it the ground then other appliances could be energized too.
@vickslab4608
@vickslab4608 5 месяцев назад
That's one way of waking up in the morning.
@brushben22
@brushben22 5 месяцев назад
My bet. The insulation foil was resting on the motor breath/vent plate and caused your windings to thin the insulation. Very important for motors to breath and I’m surprised it lasted that long
@w.knudsen5570
@w.knudsen5570 5 месяцев назад
With that chassis being hot like that, I would be concerned about a high resistant connection on the bonding.
@dashcamandy2242
@dashcamandy2242 5 месяцев назад
Thank goodness you weren't standing on wet grass, or in a small puddle, or this video could have had a completely different ending! I was once working in another capacity for the newspaper I work for now, and I was out filling the metal newspaper vendor boxes in one section of a city. Every time it rained or it was foggy and I touched this one particular box, I'd get a definite tingle! The box was secured to a metal lamp post by a metal chain, so... Yeah. Fun times.
@davidnull5590
@davidnull5590 5 месяцев назад
I'm glad you survived, that was nasty. Try to stay safe.
@chrishoughton9306
@chrishoughton9306 5 месяцев назад
I have experienced this a few times as well, its one thing i always check for now with the NCV function before i get to testing, usually poor grounding, or backfed circuits. Glad you are ok, that could have been the last thing you ever did. Be safe out there brother.
@robalexander7348
@robalexander7348 5 месяцев назад
Well done Curtis, another A/C up and running, you may score a new install down the track soon 👍 Au
@MrAdamd83
@MrAdamd83 5 месяцев назад
From what I seen it looked like the aluminum outer coating of the cabinet insulation when blower was running got pulled down to the strip heat terminals causing the unpainted portion of the unit become energized
@stevencossaboon3237
@stevencossaboon3237 5 месяцев назад
Nice work Curtis.
@HVACGUY
@HVACGUY 5 месяцев назад
Glad you enjoyed it
@wmcomprev
@wmcomprev 5 месяцев назад
When you checked the fuse box in the unit after getting shocked, you said that it was grounded. Is the other end of the ground wire connected? You're right, you should not have gotten shocked by the case.
@Bob.W.
@Bob.W. 5 месяцев назад
Yikes. Thanks. Nice job.
@kg4muc
@kg4muc 5 месяцев назад
That was a shocking experience 😅 That motor must have had a winding grounding out on the frame. Probably an open or high resistance ground on the frame of that unit as well Glad it didn’t zap you too hard! Have a good Super Bowl weekend. None of mine made it so I doubt I’ll even try to search out a feed for the game
@stangaloski4208
@stangaloski4208 5 месяцев назад
Ya i had a hot unit once. Finally found a lighting circuit was rubbed through on the metal ductwork. No idea why it didn't trip but it was about 90 volts as well.
@mxslick50
@mxslick50 5 месяцев назад
Too high of resistance through that duct path for enough current to flow, which means the breaker didn't see it as a fault, but as a small portion of the load. Same principles applied here with this AC unit.
@Aerospace_EdC
@Aerospace_EdC 5 месяцев назад
Curtis, that should not have happened if the chassis bonding to the supply ground was intact but I guess over the years the metals got corroded and lost a good bonding ?
@user-rj6eq2jk4f
@user-rj6eq2jk4f 5 месяцев назад
I think it was the foil back insulation touching the heat kit. It 9nly did it in Heating correct?
@BamaRailfan
@BamaRailfan 4 месяца назад
Heat strips almost killed me once. Was checking for cold air across the evaporator by feeling it through a small access hole. My knees were in the condenate water. Brushed the back of my hand across the heat strips accidentally and got knocked back about 5 feet. Scary lesson learned!
@pstiegman
@pstiegman 5 месяцев назад
I think that foil insulation lying on the terminals was just enough to tickle you.
@loft306
@loft306 6 дней назад
I had my kitchen sink countertop get me like that, just to make it short, the 1950s remodel buried 12 electrical boxes in plaster. They were all live, no covers. Just filled with plaster.
@joehead1294
@joehead1294 5 месяцев назад
High resistance equipment ground? Not bonded in the load center? That draw bar barking up your shins? Reversing leads baking in the sun. 👍👍
@billnahorn3939
@billnahorn3939 5 месяцев назад
Didn’t know how you were going to get that insulation back securely,excellent macgyvering . And I told you before don’t ever touch anything with the front of your HAND, always use the back thank you😮
@steveurbach3093
@steveurbach3093 5 месяцев назад
Foil backed insulation near open terminals. Duct tape
@samuelschrader6568
@samuelschrader6568 5 месяцев назад
Thank you for talking about your thought process as you troubleshoot. Thanks also for discussing why you take certain steps.
@HVACGUY
@HVACGUY 5 месяцев назад
Glad it was helpful!
@woodystokes1543
@woodystokes1543 5 месяцев назад
I like to use the OEM just makes it easier and no risk of overdraw amps in my opinion 😊
@mitchellroberson
@mitchellroberson 5 месяцев назад
Lately been testing any metal box with electrical equipment in it. Been shocked several times for weird stuff like this. Even like to check before I leave a site
@jthonn
@jthonn 5 месяцев назад
Voltage to ground, I always worry about that on older homes. I have seen many times where the ground wires for a light fixture or whatever will be hooked to the common. I have even seen it on 220 appliances. So we have a 20 year old unit with all new parts. I guess if you think about it, the rest is just sheet metal. The furnaces worry me though, like the last one being so rusty. Anyhow, nice work. Also, I don't think .3 amps on a motor like that would make any difference, especially being lower.
@Bryan-Hensley
@Bryan-Hensley 5 месяцев назад
I used to work for a satellite company and was sent to Lowe's to diagnose hum bars in the monitors. I disconnected the coax going outside to the satellite dish and it knocked me off a ladder. Long story short, the building was energized. I think it was something like 70 volts. Their maintenance didn't believe me so I ended up calling the light and power inspector. They found a main ground connector had high resistance somewhere. However the building was being energized by some bad lighting ballasts.
@Frosty_RizzerYT
@Frosty_RizzerYT Месяц назад
I can’t stand when homeowners awkwardly stand right behind me and ask a million questions
@hinspect
@hinspect 5 месяцев назад
If it was properly grounded it *_COULDN'T_* shock anybody 🤔
@mxslick50
@mxslick50 5 месяцев назад
Yes...and no. As I explained in another comment, since electricity will take all paths, it will divide amongst them, and Curtis just happened to be a part of it. But in this case the unit (or the house in general) most likely has grounding issues. A proper low resistance grounding path would make that current that Curtis experienced so small that it would not have been felt. (Or in the ideal world, totally eliminate it.)
@2pugman
@2pugman 3 месяца назад
I had a similar problem a few years ago. I lost power to my garage and I was using a "Tic Tac Tracer" lookin' for power. Nothing. I stepped outside the garage and lit up a smoke and the Tracker touched the bush and I got power ! After digging, I found the roots ate the underground wiring and the bush was "HOT" ! The bush died after a year w/o power !
@junior-hk2jt
@junior-hk2jt 4 месяца назад
it's only happened to me once, also on a package unit for a trailer, blower motor was the culprit
@arthurmario5996
@arthurmario5996 4 месяца назад
you're a nice, "chill" guy ! 🤣
@thesilentonevictor
@thesilentonevictor 5 месяцев назад
Good work Curtis
@HVACGUY
@HVACGUY 5 месяцев назад
Much appreciated
@kens.3729
@kens.3729 5 месяцев назад
RHEEM and RUUD are the two (2) “R’s” that Pay HVAC Tech Mortgages. 😬👍
@jeffreywhisnant6997
@jeffreywhisnant6997 5 месяцев назад
More problems out of rheem than any other brand seems like Curtis is all he works on in videos crazy
@JohnSmith-ug5ci
@JohnSmith-ug5ci 5 месяцев назад
Good job.
@HVACGUY
@HVACGUY 5 месяцев назад
Thanks!
@jameswood9764
@jameswood9764 5 месяцев назад
You added some real nice cut your arm open insulation repair screws!!!
@Mexicano955
@Mexicano955 5 месяцев назад
That would definitely charge you up in the morning 🔋 😮 for a day's work dude 😂
@HVACGUY
@HVACGUY 5 месяцев назад
You got that right!
@mattliebenau9083
@mattliebenau9083 5 месяцев назад
Yeah, home warranty companies will band aid things perpetually if possible. The last HVAC company I worked for did repairs for one of those places. Everyone thought they were going to get a new system for free. I think we might have replaced one furnace.
@francisbriggs76
@francisbriggs76 5 месяцев назад
It appears that the unit was not properly grounded.
@garypoplin4599
@garypoplin4599 4 месяца назад
4:18 - _There’s_ your high voltage to ground! The foil backed insulation is touching one of the heat strip overloads. Put the insulation back into place and _Viola!_ No more short. Since it was not a solid contact, the breaker doesn’t trip; nor, does the point of contact burn. EDIT: After watching the rest of your video, I see you concluded the motor was causing the short (8:36); but, notice here also the foil side of the insulation was no longer in contact with the terminal below. The motor _did_ need to be replaced because of the sloppy shaft; but, I suspect if you check the motor windings, they will ring true and will not be shorted to ground! If you still have that motor, check it. You may find that the short was cleared as soon as you moved the insulation off the heat strip terminal and not from pulling the leads from the blower motor.
@jamesoestrike2517
@jamesoestrike2517 5 месяцев назад
Likely the replacement motor was more efficient, so therefore less amp draw.
@ntsecrets
@ntsecrets 5 месяцев назад
Could that insulation that fell over inside have caused a problem? Couldn’t tell if those were just limit switches or something higher voltage in there after the blower.
@HVACGUY
@HVACGUY 5 месяцев назад
Oh, that’s high voltage! Could cause it to throw sparks.
@talk2azs
@talk2azs 5 месяцев назад
WHAT??? A home warranty company that actually pays to repaire home HVAC units? "Ain't No Way!" You need to promote this company or at least give them a shout out!
@richardyates1033
@richardyates1033 Месяц назад
If you got shocked on the shell of that unit, the ground path has been lost somewhere between the unit and the electrical panel. Perhaps the electrical panel itself is no longer grounded.
@rcstl8815
@rcstl8815 19 дней назад
I never touch a unit until I wand it. The beep will warn you every time.
@user-yd9li8oi7r
@user-yd9li8oi7r 5 месяцев назад
I stay away from those home warranty companies.
@BrianBowles19
@BrianBowles19 2 месяца назад
Nice watch
@robertAWA
@robertAWA 4 месяца назад
It seems the unit isn’t properly bonded/ground. Next time you’re there, with the disconnect off, measure voltage from L1 at the disconnect to the chassis of the unit, you should read full L1 voltage if the unit is properly grounded back to panel/ ground. If you dont read full voltage you may have a grounding problem.
@rjtantillo
@rjtantillo 4 месяца назад
the new anti-theft device!
@user-sn2gd5dn8q
@user-sn2gd5dn8q 5 месяцев назад
The problem was the insulation
@user-hw3lq4df2w
@user-hw3lq4df2w 5 месяцев назад
Did you feel a tingle when touched the outside of the unit? Glad you are OK!!
@HVACGUY
@HVACGUY 5 месяцев назад
No. I didn’t feel anything until it bit me
@timmcclannahan8309
@timmcclannahan8309 23 дня назад
That Darn inso is conductive
@beacjere284
@beacjere284 5 месяцев назад
thats scary!!!!!!
@mikeanonymous669
@mikeanonymous669 4 месяца назад
Tech gets shocked and then goes home when finished for the day. Eats dinner, watches TV and what not. Goes to bed for the night and never wakes up again. Dead. What happened? Electrical shock disrupted the heart''s natural rythym and causes cardiac arrest in the middle of the night. This is why when you get shocked, you should goto the hospital to check your rythym via an EKG. Especially if it happens on work hours.
@willwise9445
@willwise9445 5 месяцев назад
I guess I don’t understand. How can something energize ground without tripping the breaker?
@HVACGUY
@HVACGUY 5 месяцев назад
Not supposed to happen
@jamierushing
@jamierushing 5 месяцев назад
Hi bro from west Alabama
@HVACGUY
@HVACGUY 5 месяцев назад
Evening
@jamierushing
@jamierushing 5 месяцев назад
@@HVACGUY what up
@deweyabbott5310
@deweyabbott5310 4 месяца назад
Suprised you didnt get shocked when you first touched it
@codeman0311
@codeman0311 5 месяцев назад
Could it have been the foil on the insulation?
@karellodewijks4971
@karellodewijks4971 5 месяцев назад
👍👍😊😊🔊🔊
@Dmcbigboy8687
@Dmcbigboy8687 5 месяцев назад
The insulation was touching the limits of the heat pack. That probably how you were shocked.
@bradjones2480
@bradjones2480 4 месяца назад
No question that unit is not grounded correctly or at all. I would not have just swapped a motor and ran. If they have a home warranty, let them get the electrician out to comb the rest of the circuit.
@bobbychaney8372
@bobbychaney8372 5 месяцев назад
Obviously the ground was not connected or you would not have got shocked
@kimballwhite787
@kimballwhite787 5 месяцев назад
Just as a question, why wouldn’t the breaker powering the unit trip if the shell had become live with 94 volts? I don’t understand why it wouldn’t travel back on the ground wire and trip it.
@drodriguez394
@drodriguez394 5 месяцев назад
put that drill on max chooch!!!! you spin her slow.
@joedirt5521
@joedirt5521 3 месяца назад
It was the insulation
@kpdvw
@kpdvw 4 месяца назад
Never trust anything electrically, always test,test, test and wear your gloves!
@kpdvw
@kpdvw 4 месяца назад
the entire unit is NOT poperly grounded!
@captain3xtreme
@captain3xtreme 3 месяца назад
Pretty sure that case is not grounded or it should have tripped the breaker
@babakmahour
@babakmahour 4 месяца назад
Cheap costumer... I hate them... I would change the complete unit this is disaster
@mikestevenson1819
@mikestevenson1819 5 месяцев назад
Old Republic?
@HVACGUY
@HVACGUY 5 месяцев назад
Yes
@Paul-nt2bz
@Paul-nt2bz 4 месяца назад
After 20 years doing hvac ive decided theres no point. Its an abusive way to make money, nearly everyone i know in the business is poor, its just a no win job. The customers are terrible, everyone assumes your ripping them off. Your supposed to do everything free and if you work for someone else its feast and famine. The pissing macth between guys never ends. Arms folded home owners lurching over your shoulder all day. The job sucks so badly.
@user-hi4sh9um7x
@user-hi4sh9um7x 4 месяца назад
Hi sir I am AC technician I need job you are have ac technician job now i am Saudi Arabia I have experience 15 years
@Kevin-wj4ed
@Kevin-wj4ed 4 месяца назад
Unit is junk!!!!!!!!!
Далее
Odd Complaints Lead to Scary Find! #hvacguy #hvaclife
29:11
Drive through the color🚗❓
00:13
Просмотров 1,7 млн
3 PROVEN Methods To Getting Colder Air From HVAC Vents.
10:45
Industrial Cooler Major Problems
22:53
Просмотров 12 тыс.