REFRIGERATION PUMP DOWN AND HOW TO CHANGEOVER COMPRESSOR? 

leckyjake
Подписаться 55 тыс.
Просмотров 55 тыс.
50% 1

Here is the step by step procedure on how to pump down the provision refrigeration system onboard as well as the correct way on how to changeover the compressor.
#reefer #refrigeration #refrigerationcycle #refrigerationequipment #seafarer #seaman #airconditioner #hvac #refrigerationandairconditioning #leckyjake #electrician #electric

Опубликовано:

 

14 июл 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 82   
@mahmoodhassan4537
@mahmoodhassan4537 10 дней назад
The best ETO on the planet 👌
@eduardcalong796
@eduardcalong796 Год назад
Thank you for this knowledge master lecky jake.. I had learn a lot.
@akarl6578
@akarl6578 Год назад
You are the best. Thank you from Greece
@pedrojardim1163
@pedrojardim1163 2 года назад
Thanks for the very helpful and very good explanation 👍
@scorpiomarine-electrocutio7460
@scorpiomarine-electrocutio7460 2 года назад
Goodjob.this is very informative sir lecky.
@arielcunanan4994
@arielcunanan4994 Год назад
Excellent tutorials
@dennisdumale5599
@dennisdumale5599 Год назад
Thank you so much sir jake for these video. More power sir. And keep safe always. God bless to u & to ur famly🙏
@princefernandes5789
@princefernandes5789 2 года назад
Excellent job 👏👏👏🛠🔧🛠🔨🔧 good explanation 😎😎😎😎
@dennisabad7862
@dennisabad7862 Год назад
full of information thank you sir for the free knowledge.
@LinkWrayisGod
@LinkWrayisGod 2 года назад
Nice one Lecky! Greetings from Spain.
@BernieQuinia-fl3ed
@BernieQuinia-fl3ed 3 месяца назад
T.y sir to gud explaination.gud bless
@antonioreyes7476
@antonioreyes7476 2 года назад
Another learning from my favorite RU-vid channel. Mabuhay po kayo leckyjake.
@edwardjackson8183
@edwardjackson8183 Год назад
😱🤯.. you blew my mind
@judebrosas4663
@judebrosas4663 10 месяцев назад
Thank you sir this is a big help to me...thank you❤
@markvillaspin6643
@markvillaspin6643 8 месяцев назад
Thank you Lect God Bless
@kiageungwirengrana5374
@kiageungwirengrana5374 Год назад
Many thanks my bro
@Tutorial_Ref_Aircon_more
@Tutorial_Ref_Aircon_more 2 года назад
Thank u for sharing sir
@leckyjake
@leckyjake 2 года назад
Thank you for watching
@aaronjettroehidalgo534
@aaronjettroehidalgo534 Год назад
Thank you sir!
@Winstly
@Winstly Год назад
husay sir!!!
@babaolowo35
@babaolowo35 Год назад
Thanks 👍
@mahboobKhan-uy7sm
@mahboobKhan-uy7sm Месяц назад
❤❤❤❤❤
@khuatamipatheihhuaithulehl4769
Good
@fenflyer
@fenflyer Год назад
Thanks for great videos 👍 Good video on twin compressor pump down 👍can you do video on inverter scroll refrigeration compressors , please 👍 I only worked on old twin 120 KW Sabroe piston compressors systems Amonia and R22 etc 😑 Thanks for great videos 👍
@paologringoescalante6916
@paologringoescalante6916 Год назад
Maraming salamat po. ❤
@joseenricoaguila5218
@joseenricoaguila5218 2 года назад
thank you
@leckyjake
@leckyjake 2 года назад
Thank you for watching
@yousefhaeiri360
@yousefhaeiri360 2 года назад
Hi Lecky,thanks a lot please make an introduction video about the Boilers
@willrobbinson1
@willrobbinson1 2 года назад
boilers??? anyway like vid thanx
@yousefhaeiri360
@yousefhaeiri360 2 года назад
Marine Auxiliary boilers
@dhruvrajchauhan4126
@dhruvrajchauhan4126 Год назад
Thank you
@leckyjake
@leckyjake Год назад
thank you for watching
@syedbasheer8210
@syedbasheer8210 2 года назад
👍👍👍
@leckyjake
@leckyjake 2 года назад
Thanks
@akarshanilkumar3461
@akarshanilkumar3461 2 месяца назад
@markpaulofacun
@markpaulofacun Год назад
👍
@rb1m426
@rb1m426 2 года назад
Present mr. Secretary 😊 about sa plc naman Sec.
@leckyjake
@leckyjake 2 года назад
Thank you
@man15h
@man15h 2 года назад
Hello sir can you please suggest a book for understanding single line diagram and learn about switch gear and Power systems protection, relay setting and fault current calculation
@kuldeepsingh8486
@kuldeepsingh8486 2 года назад
Thank you sir can you make video for same A.C change over . And can make video on main engine course in simple way.
@leckyjake
@leckyjake 2 года назад
Will keep on the list
@jishnur9770
@jishnur9770 2 года назад
Hi Lecky, Frst of all thank you for your wonderful easy explanation on each of your video. Im having a trouble on my ushio ref system, which is no 1 compressor is getting frosted if i let the system run. Now i changed over to no:2 not pumping down , but by charging no 2. What may be the probable reasons for the frosting, no fluctuation in suction and discharge pressure. R417A was charged on no:1 last week.
@leckyjake
@leckyjake 2 года назад
i always depend on the pressures. but most of the times if you have frost in the suction you might have an overcharged of refrigerant
@jishnur9770
@jishnur9770 2 года назад
Thank you and hats off for the dedication towards sharing your experience. Always waiting for your videos.
@stonecold1553
@stonecold1553 2 года назад
Hi just want to share my insight. The trouble is your compressor is getting frosted. One main reason, the refrigerant on the suction line all the way to the compressor is not in vapor/gas form. A lot of reason way this happened, most notorious one is overcharge, malfunctioning expansion device, dirty/clogged evaporator coil, and etc. But base on the scenario you have stated it is more likely overcharge.
@bt9604
@bt9604 2 года назад
Sir, plz do a video on insulated neutral system in ship 🙏🏻
@manzillegal1
@manzillegal1 10 месяцев назад
Leckyjake hello leck could you also make video of procedure of vaccum of the system too weather Aircon or reefer thanku you ver much in advance🙏
@erwinhutapea2091
@erwinhutapea2091 Год назад
Thank you so much sir .. sir I will ask about high pressure. if vegetable ekspnsi V/v open high pressure more up until 1.8 and then direct trip .. iwhat problem sir?
@amoscolod1519
@amoscolod1519 Год назад
a very good explanation sir. you said that we need to run the compressor two times so if during the first time the low pressure switch activates how can we restart again the compressor or how will the compressor start again? will the pressure increase itself due to remaining refrigerant on the system?
@ivanfmartinezm
@ivanfmartinezm Год назад
You can force to start pushing manualy the main contactor from the compressor about 3 or 5 seconds.
@studywithssr338
@studywithssr338 2 года назад
Sir please video on circuit diagram reading
@torohdelapan8352
@torohdelapan8352 Год назад
Please give education how to change oil the provision ref machine..thx
@jrahul8136
@jrahul8136 2 года назад
Please share how to trace electrical wiring diagrams...for example motor and starters circuit
@leckyjake
@leckyjake 2 года назад
I normally include the tracing on my troubleshooting videos
@Tech-NO-City
@Tech-NO-City 2 года назад
Next time please add "What not to do" I learn more by learning from others mistakes.
@cck1496
@cck1496 Год назад
Thanks but why do we need the system to be pumped down? Why we can't keep one compressor off (rather than isolating it)? Thanks.
@leckyjake
@leckyjake Год назад
normally the changeover is being done every month, you do not want any refrigerant in the line for the non running compressos as in will condense in the latter.you do not want liquid state refrierant to enter into your compressor.
@thantzinaung6650
@thantzinaung6650 11 месяцев назад
Sir, When you were pumping down the condenser of unit 1, the unit 1 was running in auto mode ?
@rafaelhijara9534
@rafaelhijara9534 Год назад
So the switch of compressor is off already before the closing the service valve? Am i right?
@elecbaskogpogi2086
@elecbaskogpogi2086 2 года назад
Good day lec. I have a question I experience during pumping down discharge pressure is increasing until high pressure trip activated and suction pressure is not decreasing hard to activate the low pressure switch. What is the cause? For that reason I cannot properly pump down and changeover to another one compressor. Hope it will answer Thank you in advance.
@leckyjake
@leckyjake 2 года назад
first, the cooling should still be present during pump down. you can adjust the setting of your discharge pressure switch as per your manual max limit. 3rd. check for leak test on your suction side. the pressures you may be getting is the air that is goibg through your system
@elecbaskogpogi2086
@elecbaskogpogi2086 2 года назад
@@leckyjake thank you. Have a good day ahead.
@antenehberhanu4467
@antenehberhanu4467 4 месяца назад
My dear what is the problem of freezer room start and stop again and again even if refrigrant gas is infe amount in the system
@freemind6231
@freemind6231 Год назад
sir. acceptable npoba yung negative 17 s meat storage? gusto kc nila negative 20 medyo naggalangan ako galawin . tnx
@JerinMathew-rr6qs
@JerinMathew-rr6qs Год назад
Why crack open for suction side valve ??
@davidosei9560
@davidosei9560 2 года назад
Hello sir , I’m having a bachelors degree in Electrical and Electronic engineering and I will like to work on board . What are the steps I to go through before getting a seagoing job
@leckyjake
@leckyjake 2 года назад
It actually depends on your country if you are asking about requirements
@yaswanthsri2524
@yaswanthsri2524 2 года назад
u can do course called ETO
@bhongtorbs5685
@bhongtorbs5685 Год назад
Crack open lng ba talaga yan sir yong suction normaly? Or i full open mo rin yan.
@joalpsengineman4717
@joalpsengineman4717 2 года назад
Sir asan maganda .mag training sa pilipinas about electrical and reefer dto ako sa US as a Merchant Marine sa APL mahal ang training dto nasa $20k per training ng reefer at electrician and it takes 6 months
@nelsonramirez7586
@nelsonramirez7586 2 года назад
Hello sir.. i just ask if you need to deactivate first or set some setting in the control to not activate the pressure switches while doing pump down??? Thank you in advance
@leckyjake
@leckyjake 2 года назад
good question, if the suction pressure switch is more than zero bar/MPa then adjust it to zero.
@nelsonramirez7586
@nelsonramirez7586 2 года назад
@@leckyjake Thank you sir.. God bless you always and takecare... one of your subscriber here 😊
@teslapower220
@teslapower220 Год назад
Haven't reefer containers made these systems obsolete?
@royceroneilramos
@royceroneilramos Год назад
Ano po yung dahilan bakit need munang naka crack open lang ang service valve ng suction side sa compressor 2? Thank you idol 🙂
@ninogonzales4621
@ninogonzales4621 11 месяцев назад
Sir leckyjake patulong naman yong fish room namin ayaw mag reach sa -18 ,hanggan-13 lang sya. Palaging nakabukas yong expansion valve kaya nag ice na yong evaporator. Kahit nag depros na kami ayaw pa din talaga tumaas . Patulong po. Salamat idol
@adepojuadewale1567
@adepojuadewale1567 19 дней назад
please can u send this unit diagram
@asifraza1663
@asifraza1663 5 месяцев назад
I want to join criuse line i have 5 year experience in Dubai can you help me
@kaden2985
@kaden2985 2 года назад
ρгό𝔪σŞm
@randygalang4994
@randygalang4994 2 года назад
Chinese ka sir?
@leckyjake
@leckyjake 2 года назад
noypi ako
@randygalang4994
@randygalang4994 2 года назад
@@leckyjake Salamat sir....
Далее
ШОКОЛАДКА МИСТЕРА БИСТА
00:44
Просмотров 1,2 млн
Good dad 🥰 #demariki
00:17
Просмотров 9 млн
AUTO PILOT POWER FAIL AND HOW TO READ WIRING DIAGRAM
11:52
AUXILIARY BOILER NOT FIRING, TROUBLESHOOTING
9:38
Просмотров 36 тыс.
Burnt VFD, Why?????
8:45
Просмотров 22 тыс.
DIY Cascade Refrigeration System (Part I)
19:15
Просмотров 255 тыс.
GENERATOR TROUBLESHOOTING, NO STOP OPERATION
9:53
Просмотров 29 тыс.
How to pump down refer compressor unit
5:19
Просмотров 3,3 тыс.
ШОКОЛАДКА МИСТЕРА БИСТА
00:44
Просмотров 1,2 млн