@phoenixhvac-r828
@phoenixhvac-r828 Месяц назад
What I've seen here in phoenix is many ac companies don't increase return air when upgrading from 22 to 410a, also alot of undersized systems, good to see there are companies like yours still out there
@HeavyPressureHvac
@HeavyPressureHvac Месяц назад
@@phoenixhvac-r828 Many guys just change the box and dip out. Those installs are a hit or miss😬 Im afraid of callbacks bro thats my problem😂
@everythinghomerepair1747
@everythinghomerepair1747 Месяц назад
Yes I agree. I had two four ton systems for a two story 4,000 sqft house. I think that’s pretty undersized. There were only two returns in the house one upstairs and one downstairs and no zoning/ jumper ducts or anything of the sort. The house was built in 1997 and I think that was common for the time.
@HeavyPressureHvac
@HeavyPressureHvac Месяц назад
If i go to bid an older house, they will come out with some sort of duct modification, its a must with a new system. 💯
@Straycurrent
@Straycurrent Месяц назад
The previous company’s failure to revamp the curb and ducting is shameful. Your work is impressive….neat and thorough. I hope you showed some before and after photos to the owner!
@HeavyPressureHvac
@HeavyPressureHvac Месяц назад
@@Straycurrent always 😎 thats my proof work was completed properly💯Thank you sir 😇
@tommymatthews4984
@tommymatthews4984 Месяц назад
Went to a call once where people installed a unit 3 years back before i was there and both units of the house was down one was the capacitor and the one they installed 3 years ago never actually ran. The service valves was still closed. The home owner had no clue and just assumed it worked lol
@HeavyPressureHvac
@HeavyPressureHvac Месяц назад
@@tommymatthews4984 I got a friend that does tech support for our town, He says majority of the installers/techs that call dont even the know the basics 😬
@thejnelson88
@thejnelson88 Месяц назад
That flashing you did! 🤩🤩🤩
@seangriffon6502
@seangriffon6502 7 дней назад
I ll take that rheem unit. Hope he can sell it and recoup some of his money and its still u der warranty as well. Great job on the new install.
@HeavyPressureHvac
@HeavyPressureHvac 6 дней назад
Yeah i think he sold it online , he got some of his money back atleast 😎
@everythinghomerepair1747
@everythinghomerepair1747 Месяц назад
Wow that termite stuff is scary/ disgusting. I don’t think I’d stick my hand into that lol. Termites are super common and aggressive in the valley but wow to let it get that bad that they are on the roof sheathing of a sloped roof is crazy. You’d think there would be obvious signs in the house before it ever got that bad but since you said it’s a rental that makes sense.
@HeavyPressureHvac
@HeavyPressureHvac Месяц назад
@@everythinghomerepair1747 luckly the owner was aware, he had dealt with termites before. I had never seen damage like that before 👀👀
@amsoiltek
@amsoiltek Месяц назад
I used your recommomdation when I went to replace my HVAC. I had a 20 plus year old RUUD package unit R-22 and probably R-1 ducting and went with R-8 and a Bosch IDP 5 ton inverter unit. I also removed my Mastercool ADA70 swamp cooler, my wife was not happy with all the moisture. We live in the high desert near Victorville, Ca. I do love my Bosch heatpump.
@HeavyPressureHvac
@HeavyPressureHvac Месяц назад
@@amsoiltek Thank you for considering and congrats my friend 😎 with R8 ducts and a Bosch, that power bill is about to go way down! 👀👀🤩 If you have any questions in the future reach out to me on here💯💯💯
@WilsonRebuilds
@WilsonRebuilds Месяц назад
Nice work!!❤
@HeavyPressureHvac
@HeavyPressureHvac Месяц назад
@@WilsonRebuilds Thanks man! 💯💯
@gordonpotts753
@gordonpotts753 Месяц назад
Nice work
@HeavyPressureHvac
@HeavyPressureHvac Месяц назад
@@gordonpotts753 thanks! 💯💯💯
@rudycorraudio9089
@rudycorraudio9089 Месяц назад
Great channel. I Just subscribed. I'm learning a lot.
@HeavyPressureHvac
@HeavyPressureHvac Месяц назад
Thank you! If you got questions reach out on here, ill help you out if you need help 💯💯😎
@rudycorraudio9089
@rudycorraudio9089 Месяц назад
@@HeavyPressureHvac Actually I do. The blower motor on a Rheem 5 ton package unit won't stop running. It seems I need a new $ 400 motor it's the x 13 motor. Where else should I check. The wires are good and so is the board. It has a new capacitor too.
@HeavyPressureHvac
@HeavyPressureHvac Месяц назад
Cut the power and unplug the low voltage from the motor, bring power back, if the motor spins without the low voltage hardness then yeah you will need to replace it 😞 Check that the thermostat is not sending 24v to the G all the time. Some of those have a relay, check that its not stuck closed. 9 out of 10 on those x13, its the module 😑
@rudycorraudio9089
@rudycorraudio9089 Месяц назад
Will do. Thank you.
@Jets-and-airconditoning
@Jets-and-airconditoning День назад
Bruh only 6 months old? That’s very new you should scrap a lot of things or the whole unit
@HeavyPressureHvac
@HeavyPressureHvac День назад
@@Jets-and-airconditoning The owners ended up keeping it, and i think they sold it within a few days😎
@bgreenwood9730
@bgreenwood9730 Месяц назад
Damn the 24 volts was not being sent through because of a loose wire nut really😮new system wtf ?
@HeavyPressureHvac
@HeavyPressureHvac Месяц назад
If you pause the video you will see the blue wire from tstat tighted to the Yellow from the AC, that was not the issue.
@bgreenwood9730
@bgreenwood9730 Месяц назад
@@HeavyPressureHvac what was problem in the 1st place? It looked like re- wiring an a fuse might have got them cooling.
@HeavyPressureHvac
@HeavyPressureHvac Месяц назад
Unit ran 24/7 never satisfied. It was pulling heat from return/ ductwork and under curb .
Далее
You're wasting money on heating! Use your A/C!
17:11
Просмотров 460 тыс.
Ajdarlar...😅 QVZ 2024
00:39
Просмотров 267 тыс.
拉了好大一坨#斗罗大陆#唐三小舞#小丑
00:11
Testing The Burn Ability Of Insulation In Wall
19:45
Просмотров 2,6 млн
Underfloor Heating as First Time Builder
17:28
Просмотров 79 тыс.
Converting a split system to a roof packaged unit.
12:18
Mapping Your Home to Optimize Air Sealing
6:45
Просмотров 41 тыс.
Air Conditioning isn't free... but we're close.
25:45
Clogged AC P Trap worst ever
20:33
Просмотров 15 тыс.
This 84 Year Old Widow Was NOT Expecting This!
22:32
Просмотров 60 тыс.
Ajdarlar...😅 QVZ 2024
00:39
Просмотров 267 тыс.