Replacing My Whole Electrical Panel 

Electric Pro Academy
Подписаться 82 тыс.
Просмотров 134 тыс.
50% 1

Electric Pro Academy - Real skills to make real money.
Synopsis:
Joel and his family recently moved into a 1938 home in Indianapolis, Indiana. Unfortunately, they bought the property knowing that many electrical upgrades would need to be made, but fortunately, Joel was up to the challenge and willing to bring viewers along. In this video, Joel will be replacing one of several out-of-code electrical sub-panels throughout the home. He’ll run into several electrical issues, dated practices & components, and nightmares including back-fed neutral current, BX wiring, tinned copper, narrow stud cavities, wire connections in the panel, grounding circuits through conduit, AFCI breakers, and more! While our content is mostly targeted to electrical apprentices, we hope it can be helpful to DIYers, hobbyists, & home project enthusiasts as well.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: forms.clickup.com/f/23xa9-70/...
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
*EPRO endorses pro-level tools & materials, and receives a small commission for purchases through our links through Amazon & other affiliate programs. We’d be happy to recommend more cost-effective products for DIYers and low-frequency users if you engage with us in the comment section!
[] Dewalt 20V Max XR Brushless Sawzall (DCS367): www.amazon.com/DEWALT-DCS367B...
[] Gardner Bender Locknut Wrench Set: www.amazon.com/Gardner-Bender...
[] Knipex Lineman's Pliers: www.amazon.com/09-08-240-SBA-...
[] Fluke 117 Multimeter: www.amazon.com/Fluke-117-Elec...
[] Scotch Linerless Black Electrical Tape: smile.amazon.com/Scotch-Liner...
[] Non-Contact Voltage Detector: smile.amazon.com/Klein-Tools-...
[] Siemens 100-Amp 20-Circuit Electrical Panel: smile.amazon.com/Siemens-PN20...
[] ATG Maxiflex Nitrile Gloves: www.homedepot.com/p/ATG-MaxiF...
[] Klein Tools Folding Jab Saw: smile.amazon.com/Drywall-Lock...
[] Crescent Wiss Aviation Snips: smile.amazon.com/Wiss-M3R-Met...
[] Dewalt 20 Max VR Brushless Hammer Drill (DCD999B): www.amazon.com/DEWALT-FLEXVOL...
[] Milwaukee Folding Rule (Inside Reading): www.homedepot.com/p/Milwaukee...
[] ½” Bond Bushing: www.homedepot.com/p/1-2-in-Ri...
[] Irwin 3-Piece Tongue & Groove/"Channellock" Plier Set: www.lowes.com/pd/IRWIN-Groove...
[] Dewalt 20V Max XR Brushless Impact Driver (DCF887): www.amazon.com/DEWALT-DCF887B...
[] Milwaukee Wire Strippers: www.homedepot.com/p/Milwaukee...
[] Siemens 20-Amp Single Pole AFCI Circuit Breaker: smile.amazon.com/Siemens-QA12...
[] Gardner Bender Duct Seal: www.homedepot.com/p/Gardner-B...
National Electrical Code (NEC) referenced in this video:
Free Access Here: www.nfpa.org/codes-and-standa...
[] Mechanical best practice in an electrical panel [NEC 110.12]
[] Best practice for general electrical connections [NEC 110.14]
[] Maintenance & working space requirements [NEC 110.26]
[] Additional wiring equipment in enclosures [NEC 312.8]
Outline:
0:00 - Introduction
0:35 - Work Preparation
2:37 - Voltage Testing & Code Violations
4:39 - Identifying circuits
5:48 - Voltage Retesting
7:45 - Passthrough & Code Corrections
10:24 - Removing Locknuts
12:02 - 3 Safety Observations
15:29 - Measuring & Probing Wall For New Panel
18:00 - Cutting New Panel Wall Opening
23:05 - Identifying & Stripping BX Wire
28:10 - New Panel Knockouts
32:10 - Mounting The New Panel
35:19 - Grounding BX Conduit To The Enameled New Panel
39:30 - Securing New Panel
40:38 - Terminating Wires
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
www.jeffersonelectricllc.com/
/ jeffersonelectric
/ jefferson-electric-llc

Наука

Опубликовано:

 

28 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 262   
@Gruntled2001
@Gruntled2001 2 года назад
It is incredible how someone this good at his trade would be generous enough to share his knowledge ❤️
@leroylawrence4866
@leroylawrence4866 Год назад
A tremendous benefit for all levels of electricians.
@AndrewJamison79
@AndrewJamison79 Год назад
@@leroylawrence4866 I am not an electrician but i appreciate the content as an informative source
@WelcomeToLoco
@WelcomeToLoco 4 месяца назад
That’s because he’s a Christian
@aaavellone
@aaavellone 2 года назад
Chicago Sparky here. You are one of two American YT electricians actually worth watching. The other being Dustin at ElectricianU. Thank you for not only doing your job properly but also caring about craftmanship. I started watching British and German sparkies cause there was such a lack of actual good work being done by Americans here on YT. And in real life as I've long lost track on how many times I've been on a service call or a rewire and open a J-box and my first thought is WTF?! Thanks again.
@lua-nya
@lua-nya Год назад
There are also electricians doing sub par jobs here in EU, I just haven't found them in YT. Trust me, you should see the junctions I've seen...
@aaavellone
@aaavellone Год назад
@@lua-nya I belive you. I work in Hyde Park Chicago which is one of the 2 neighborhoods that the Chicago Wolrd's Fair that debuted electricity was at in the late 19th century. Sometimes I pull out 100 year old BX from a wall, see old gas lines (which no one ran wire through although that rumor is popular), and sometimes I'll get a panel that has pink, purple, and yellow wire in it.
@Makitafan
@Makitafan Год назад
I can't say Dustin's content has been any good for a while now. IMO. Check out United Tradesman Academy. He films his service call. Worth the watch . I think.
@buggsy5
@buggsy5 Год назад
@@aaavellone Multicolored hot wires are allowed in US commercial systems. I don't know if the same can be applied to US residential wiring. Nor do I know if the multicolored hot wires contain a single shared neutral or separate neutrals to go with each hot. I seem to recall that, in the USA, any colored wire can be used for hot conductors except white, bare, green or green/yellow. Besides having a much larger population in the US compared to UK - I think a higher percentage in the US think they know it all so have no qualms about making videos of what they do.
@aaavellone
@aaavellone Год назад
@@buggsy5 interesting. In residential the code where I work does not allow switch legs in a panel. I personally enjoy seeing more color (assuming the color doesn't change further down the raceway at another junction). We are suppose to have black and red to differentiate between the two phases.
@Kevin-ip8uf
@Kevin-ip8uf Год назад
you mention backfeeding: The very first panel replacement I ever did was a fuse to a breaker panel. when I put everything back and turned on the breakers, energizing one would trip another, and turning that on would trip the other. two different circuits feeding the same thing, back in the fuse panel they were on the same phase and had no issue by the end they were on opposing phases so turning them both on would trip one. just disconnected and capped one of them and left it fed from the other. It was 17 years ago and it's something I've never forgot.
@chrisruss7863
@chrisruss7863 6 месяцев назад
I run into that about once every 25 or 30 panel changeouts in residential. BOOM 240v short when reenergizing the branch circuits. I generally inform the homeowner of the issue and let them know it will be a separate service call/ charge to correct it, and cap one of the power feeds.
@cupdejello
@cupdejello Год назад
Here in nyc we still use bx all the time. It’s nice to work with. Don’t have to deal with any ground wires since the whole system is grounded using the armor and the bonding strip. Today’s bx doesn’t have cloth insulation. It’s all THHN in there with a paper moisture barrier
@geedagod9112
@geedagod9112 2 года назад
Real World installation, things may not go as planned but we adapt and over come. Great Video
@SavedByFaithInJesus
@SavedByFaithInJesus Год назад
32:28 "Slow is smooth and smooth is fast." Had a firearms instructor say this many years ago. Also, "If you can do it a thousand times slow, you can do it once, fast." Edit: I would have taped the damaged wire before putting in the panel.
@jameskappel
@jameskappel Год назад
Enjoyed the clarity statement - Electricity take ALL paths!! and primarily the path of least resistance.
@InnaciKorushka
@InnaciKorushka Год назад
I cannot tell you how many panel videos I watched. I searched replacing a panel, etc etc and never saw even 1 of your vids. The sad part, is that your vid is EXACTLY what I was looking for and all the others lacked in many ways. Not to mention yours is much higher quality and I very much appreciate that.
@tighecrovetti2844
@tighecrovetti2844 2 года назад
The amount of knowledge you are giving away on this channel is nothing short of amazing. "Make it easy on the next guy. Next guy might be you." - needs to be a shirt, STAT
@brendanlynch2138
@brendanlynch2138 2 года назад
“Electrician” that came to my moms house to fix a disaster from her kitchen contractor had 2 circuits back fed. I’m an electrician and I physically showed him look you have 2 hots tied together. I knew they were HR, he tells me that’s not possible. Would have fixed the electrical myself but he refused to give any sort of refund. Sometimes it’s just worth doing it yourself for piece of mind.
@branetraveler
@branetraveler 13 дней назад
What a great collection of tips and best practices. Really like the Siemens Plug On neutral panels.
@thenexthobby
@thenexthobby Год назад
Mad skills on the recip saw, but I think there's an oscillating saw in your future. I'll need to pick up a 4 1/4 circ saw because my walls and ceilings are all 3/4" or 1" hardwood tongue-and-groove. You can hang a picture frame anywhere you want -- no need to find a stud -- but any wall work becomes a woodworking project! We have early NM in our '39 house: The outer jacket is cloth and coated in varnish.Wires are the tinned copper wire, with the same failing cloth insulation as yours. At first I thought the wires were steel LOL. You were expected to solder connections inside of junction boxes and wrap with cloth tape soaked in who-knows-what. When I replaced a basement light fixture I had to cut the wrap off with a knife; it was rock hard. (And then I found the soldered connection and just cut the connection out.) Consider that prior to that, the first wire nuts were porcelain and later, Bakelite. Both likely cost more and took longer to deal with than simply soldering wires already tinned.
@mesochace
@mesochace Год назад
@ElectricProAcademy - Always great to watch your videos and to pick up the nuggets of real world experience! At 44:08 When you have a bare neutral in a 3-wire cable, how do you assure that this conductor does not come in contact with the panel which is bonded to ground? Thanks!
@suspicionofdeceit
@suspicionofdeceit Год назад
That bare neutral needs to have a new wire pulled,it’s a code violation. The neutral conductor must be insulated.
@jeffreyeaton5214
@jeffreyeaton5214 Год назад
@@suspicionofdeceit NEC allows for bare neutrals for SE cables. Always check municipal/state codes as well, but per NEC, bare neutrals are allowed in *very* few applications(In the case of this video, that would need a new cable pulled, just posting this for clarity that there are a few noted exceptions per the NEC)
@Doug-gp2qw
@Doug-gp2qw 2 года назад
Put some heat shrink over the fraying wires. It might prevent a panel fire until you can replace it. For cutting BX cable bend the cable and use a hacksaw or Dremel at the bend. Less chance of nicking a wire. If you select a Square D plug on neutral panel (QO or Homeline) you can get plug on neutral breakers for faster and neater installation. They also have a plug surge suppressor available. I use GFCI/AFCI combo breakers for all circuits with outlets regardless of location. A little extra insurance. Before my kids started crawling I put a GFCI on every circuit. One day when my son was about 1 years old I hear him giggling. He was sitting on the floor next to a hydronic baseboard heater. He was licking a plastic string from one of his toys and sticking it in the outlet. He tripped the GFCI a couple of times.
@BassStormSC
@BassStormSC Год назад
First off, I've enjoyed watching your videos for the past couple weeks. They've been very informative as I am a licensed electrician myself (as of this past Feb). There have been things that you've done that I would have differently and have learned a few things like the trick you did with using the piece of wood to keep your pilot bit in line of the hole for the feeder conduit. The only thing I'll state as you may have learned since this video being a year old now is that this panel appears to be a Plug-in neutral panel for AFCI and GFCI breakers. The copper buses on the sides you see can use those breakers for your neutral path and the breakers are probably $10-20 cheaper than the regular ones. They have no pigtail and just makes it look cleaner. Also I'd rather use a flat cutter for carving that panel out but your sawzall skills are very good. Nice job and looking forward to more videos.
@ronaldmahoney1283
@ronaldmahoney1283 Год назад
Your one of the best Teachers of electrical, practical theology that can really explain the tasks from the beginning of the job to the end. A lot of videos, whether its carpentry or pluming don"t know how to relate the information so it can be understood to the novice in detail! Your left wondering, what did I miss! Thank You! You make it look fun and interesting!
@thomasbrittinghamjr.8508
@thomasbrittinghamjr.8508 2 года назад
I ran into this same problem when I was replacing a Federal Pacific panel in my old house built in 1947. The lumber's actual dimensions were 1/4" larger than the studs nowadays. Ended up having to chisel out 5/8" out of one of the studs in order to fit the panel in with an 1/8" of play. Of course, this was after the meter had been pulled and my oscillating saw is 120V so hammer and chisel away.
@user-lf7en6rf8m
@user-lf7en6rf8m Год назад
Jefferson, as you know having space to work is very important, you could open the drywall up a little more and then re drywall, just a tip, score the pencil line with a razor knife, excellent work i learn so much from you, Arizona 👍
@devil262786
@devil262786 2 года назад
Nice job love the video on this step 31:33 what I would’ve done was cut a piece of wood that fit inside the panel horizontal to the bottom of the panel so the wood was evenly touching inside the panel avoiding the edge and that would prevent those two extra holes from popping out
@Pasrich
@Pasrich 2 года назад
Smooth delivery on the explanations! Thanks for showing us how you overcame the obstacles encountered in this installation.
@JR82
@JR82 2 года назад
I really like the level of instruction you provide with your videos. It's reasonable to assume that when a master electrician sees these kinds of videos that they will advocate that *only* a master/certified electrician should be doing this type of work, so covering the basics isn't necessary. That being said, you know as well as I do that a DIY'er is going to do the work whether they should be or not - so you taking the opportunity to educate is only helping to assure their work is getting done as safely and accurately as possible. Only constructive feedback I have is that you took us 95% of the way, then ended the video. Might be good to add-on testing, validation and reenergizing the panel. "Trust, but verify" - When it comes to electrical work, it's OK to trust the installers work, but better to verify it. Excellent video, great work. You get a like and subscribe from me!
@rickwatkins3085
@rickwatkins3085 Год назад
Excellent video, a suggestion, if you dont have a MC cutter. Bend the wire, like you did, then twist both ends of the metal covering IN OPISITE DIRECTIONS, then a loop will pop up and it is much easier and faster to cut.
@steveloux4709
@steveloux4709 Год назад
A few items: I think I would have wrapped the SER cable (sub-feed upstairs) rather than leave it exposed with the potential to come in contact with equipment grounding conductors. Secondly, I didn't get any "closure" after the blowout of the adjacent knockouts and your ultimate solution to effectively close these items. I WAS expecting you to pull out a 4-S blank cover and bolt it up in this area, so that you could punch the knockouts you needed, but that didn't appear to happen. Finally, in addressing the conductor insulation that was frayed, I think I would have taken the opportunity to lap phase tape from the connector all the way down to the termination to encapsulate the insulation and allow for flexibility without worrying that the insulation would continue to crumble as it was manipulated into the new cabinet.
@ElectricProAcademy
@ElectricProAcademy Год назад
Good suggestions Loux! You didn't like my duct seal closure of the blown knockouts?
@steveloux4709
@steveloux4709 Год назад
@@ElectricProAcademy I think I commented before I saw you pull out the duct seal. Effective? Yes, I would readily concede that. But I probably would still favor the 4-S blank solution, to provide better grounding continuity. Obviously your use of the grounding bushing on the raceway eliminates any real concern in this specific instance.
@lua-nya
@lua-nya Год назад
I'm glad to see electricians that don't fall for the least resistance path.
@ed6837
@ed6837 7 месяцев назад
Excellent descriptions and work. I have been an electrician (42 yrs.) formerly licensed in 3 states now retired. I find that I agree with your work and explanations almost 100% of the time. (electricians have to argue about something). I think the only thing I would have done different was fixing the broken out KOs on the 1 1/4 conduit feed. I would have punched a 1 1/4 hole in a 4 x4 electrical box cover and put that inside or outside the panel of the panel and secured it with a couple of screws. But the bond bushing has you covered. Good Job!!
@workerofwood568
@workerofwood568 10 месяцев назад
Great idea with the wood block to guide your center drill bit on the hole saw!! Sometimes you have to get creative to get the job done:) Thanks for the slow and smooth tutorial 👍👍😎
@workerofwood568
@workerofwood568 10 месяцев назад
BTW, came here after I saw your work with The Stud Pack!!:)
@WilliamBurkard
@WilliamBurkard 2 года назад
you should use the blown up pliers for the locknut hammering!
@arkansasboy45
@arkansasboy45 2 года назад
Very well done! Thanks for explaining the code as you went because I learned a lot of good information.
@mikewalck3777
@mikewalck3777 Год назад
Live - Dead - Live check/verification for absence of voltage is the best practice to ensure that you do in-fact have an absence of voltage. The chicken-stick (non-contact voltage tester) is a good way to recheck or locate a possible live wire(s). However, I would not trust my life or someone else's life on the final determination of the absence of voltage. By the way, I like your videos and explanation/how to/why. Respectfully, Mike
@alantorrance6153
@alantorrance6153 2 года назад
At 10:35 it would surely have been advisable to check if that red wire is live. Yes?
@dwaineruthannarmentrout1811
@dwaineruthannarmentrout1811 5 месяцев назад
Thank you Joel for your detailed step-by-step instructions especially how to verify everything before starting to remove the old sub panel. So key to prevent problems and frustration. Just recently my son and I replaced the old 100 A sub panel from his home built in 1940 using your techniques. We installed the new Eaton PON all-in-one AFCI/GFCI breakers where required which I'd highly recommend. I felt confident undertaking this project using your instructions.
@oleanderson3693
@oleanderson3693 2 года назад
You replaced a 60 amp panel with a 100 amp panel with 100 amp main breakers. Are the main incoming wires sized for 100 amps? I didn't hear you address that.
@kr-sq3gf
@kr-sq3gf Год назад
He said awg 4 so yes
@jimsvideos7201
@jimsvideos7201 Год назад
Thank you both for the work it takes to film this. I think if I was into the drywall anyway I'd open enough room to get another 2x4 on the outside of the one on the right side of the panel. Run the new one down to the plate, glue and screws, notch the original one further.
@ElectricProAcademy
@ElectricProAcademy Год назад
Would definitely add some structural support! I opted out because 1) this was just a "honey-do" job, 2) I didn't know when I'd get around to patching it and I wanted to keep my kids out of the mess, and 3) I'm not much of a drywallers so less was more 😅 More power to you though!
@A2ZGeek
@A2ZGeek 10 месяцев назад
I'm a Handyman and have obsoletely loved watching your stuff and learning more and more. I pride myself on doing things the right way! It helps me sleep at night knowing I haven't made a dangerous mistake that could cause my clients to lose their home or even worse. I'm doing my part to erase that stigma that handymen are just fly by night hacks with no real knowledge or concern for the proper way of doing things. Thanks for taking the time to teach, this is something that future generations will require as people entering the trades become less and less and the need to protect and distribute this kind of knowledge becomes more important then ever.
@user-lf7en6rf8m
@user-lf7en6rf8m Год назад
Fantastic, ive been installing voice, data, fiber optics, I understand the basics of electrical installs, your awesome, excellent video,
@outlet6989
@outlet6989 2 года назад
I enjoyed your video. Being a DIYer, I can never learn enough, especially concerning electrical work. My comments are in no way meant to detract from your commentary. They are just meant to let you know that I might do things differently. I never make a 'mental note' when doing a DIY project. As far as I'm concerned, all notes must be written down and a diagram, if needed, made. There is no paper in my brain, I think. When probing inside a wall, I use my endoscope. This allows me to 'see' what's there. When cutting drywall, I use my multitool. I wrap red electric tape 1/2" from the teeth to guide me while using the tool. If I need to join wires, I always use WAGO connectors. To me, wire nuts are past history. Those wires look so old. I would wrap white tape on all the common wires. When tightening screws, I use a 3/8" torque wrench. I have a few other comments. So, come over, and we'll sit on my patio, talk electrical, and have some cold ones. P.S., please bring along the wife.
@mackfisher4487
@mackfisher4487 2 года назад
Use magnet to remove metal shavings, bullet level magnet etc.
@michaelquillen2679
@michaelquillen2679 2 года назад
Great Video!!! Everything I've seen on 'tube videos deals with a "perfect" situation, Yours shows a few challenges one might experience. Kudos!!! Thanks for the video!
@dwightharmon9374
@dwightharmon9374 Год назад
Great job Jefferson Electric!! Keep up the great work Joel!!
@Vchat20
@Vchat20 Год назад
As just a simple homeowner, I am loving your channel and the way you educate about everything as you go along is amazingly well done. Definitely getting a subscribe from me. Probably won't tackle most of the stuff and will still rely on professionals, especially living in the city and trying to navigate all the code nuances. But still fun to learn some of the ins and outs. Bonus points: Loving some of the van/camper videos you've done as someone who has that kind of thing on his bucket list. Those are definitely good education material for that DIY project in the future.
@circuitbreaker9001
@circuitbreaker9001 2 года назад
I prefer knock out punch instead of hole saws. Nice video.
@dustina6261
@dustina6261 2 года назад
Agreed hydraulic knockout is the only way to go, been doing that over a decade for mine and allows to make holes line up where kos don’t presently exist
@kbfg-hfjy4872
@kbfg-hfjy4872 Год назад
Thanks for sharing this to keep us safer as we try to fix an electrical problem, you are the man!
@Noah-qt3rq
@Noah-qt3rq Год назад
I appreciate your enthusiasm for teaching.
@Jutilaje
@Jutilaje 2 года назад
You gotta get one of those roto-split armored cable hand saws. They're incredibly convenient and not expensive at all (maybe $30-$40). Screw using tin snips to try and strip armored cable! I've only ran into armored cable maybe a dozen times and it's still more than worth it!
@stephenrichard9278
@stephenrichard9278 Год назад
Really very helpful Sir. Replacing old federal pacific panel right now. Subscribed
@xaviermcgraw6865
@xaviermcgraw6865 Год назад
Just commenting on a random video of yours. Coming in contact with the trade as a Utility designer your videos have helped me tremendously on understanding what type of work is done and needed on the other side of the meter. Thank you!
@eddiewillis9182
@eddiewillis9182 2 года назад
Thank you for doing these videos. Very helpful…
@jafarhatami6567
@jafarhatami6567 Год назад
well done and very nice explanations. Thanks
@bestshrooms3283
@bestshrooms3283 2 года назад
Wow, awesome videos. It's like your actually a licensed electrician.
@Jonacarpenter
@Jonacarpenter 5 месяцев назад
Thanks for the great video and tut!👍 keep up the good work!
@d.t.3495
@d.t.3495 Год назад
15 min in and noticing how thorough you are. Amazing!!
@chrislewis1967
@chrislewis1967 2 года назад
Real world job, nice explanations. I call the anti short bushings red heads. Always have extras from when working on mc cable jobs. Amazing how many old bx and mc connectors on older homes don't have them.
@edwardpetty5401
@edwardpetty5401 2 года назад
Thank you for sharing. I enjoy and learn from your videos.
@Leonitus485
@Leonitus485 11 месяцев назад
You need to get yourself a multi tool. They are so awesome to have and it literally pays for itself.
@ElectricProAcademy
@ElectricProAcademy 11 месяцев назад
Are you referring to an oscillating multi-tool or a Swiss Army Knife/Leatherman? Got a link to share your favorite?
@gunlover1955
@gunlover1955 Год назад
Can you use heat shrink over the bad wire insulation in the places it's weak seem like it would be a good repair?
@buggsy5
@buggsy5 Год назад
Maybe. It might require reducing the temperature rating of the wire.
@BrianIrwin
@BrianIrwin 2 года назад
I am really enjoying the videos at your house and how clearly you explain things as you go along. Our house was built in 1911 and I am (very) slowly upgrading the electrical. Going to switch out the main breaker box here soon from the current split-bus setup (need to verify if my QO Box is impacted with the new recall) but the piece that spoke to me most was your take on BX. We have a lot of BX and some old cotton wrapped romex. I have what I guess is an irrational dislike of BX, I really want to remove it but if you are not considering it a top priority then I guess I need to take that into account. So maybe I will focus on the cotton stuff first since it is not contained within the armor. Some of my circuits are wild, one runs a few downstairs electrical outlets, then a couple of upstairs electrical outlet and then the upstairs ceiling sconces. This is too much stuff on one circuit I feel, and an outlet blowing at night taking out my lights seems unacceptable. How do you tackle wild situations like that, do you just start a new circuit and move the outlets over one at a time until you find some sort of Franken-connector?
@microcolonel
@microcolonel Год назад
My favourite way of explaining the "path of least resistance" misunderstanding is to say that THERE IS NO SUCH THING AS AN OPEN CIRCUIT. The path of least resistance experiences the greatest current.
@terrylewis5786
@terrylewis5786 7 месяцев назад
I appteciate your content. There are very reasonably priced knock out kits to avoid drilling panels. They are worth every cent to get precise holes without blowing other KOs out. Great video ❤
@harveypaxton1232
@harveypaxton1232 Месяц назад
Another excellent video Joel!
@EliasRodriguez123
@EliasRodriguez123 Год назад
Thanks for the great video!
@ozzyorevir9033
@ozzyorevir9033 2 года назад
NICE VIDEO AND VERY GOOD EXPLANATION.
@biggoomba2066
@biggoomba2066 Год назад
Excellent video! Thanks a lot
@robertrodriguez2218
@robertrodriguez2218 2 года назад
This guy is really really good I like the way he talks hes a human hes real responsible he can communicate good he is an arrogant
@andrewsalazar98
@andrewsalazar98 Год назад
Those anti short bushings are called Red Devils where I’m from!
@MegaJacd
@MegaJacd Год назад
39:18 Love your content! I'm not yet an electrician, but I work in solar. I do prep work on solar and battery systems for inspection and then host them. I've had many an inspector call out that 2nd screw you left off the bond bushing. The reason I've been given is the 2nd screw is what bites into the threaded conduit and actually bonds it, without the ground screw it is simply the bushing that is bonded, not the actual conduit. Curious to know your thoughts?
@jacob9340
@jacob9340 Год назад
43:34 I'll tell you exactly what happened. Someone bought the breakers in order to pass inspection then once they passed, they returned them and replaced them with regular breakers
@buggsy5
@buggsy5 Год назад
From my understanding AFCIs are still unreliable. I have GFCI breakers in just about every circuit in my house - but I will resist installing AFCI breakers unless forced to install them sometime in the future by my house insurance company.
@jacob9340
@jacob9340 Год назад
@@buggsy5 I personally hate Arc faults...
@RonSch123
@RonSch123 Год назад
Licensed Illinois sparky here. Love your videos as well as Dustin's from EU. The only thing that scared me was the position of your finger when using the Sawzall at around 21 minutes. So easy to slip. Keep your fingers as well as the videos coming!!
@MadMax-pu1kj
@MadMax-pu1kj 2 года назад
Excellent video! My only comment is that you stressed (a lot) to separate the Neutral and Ground; almost to the point where one might believe you always do that on every panel. If fact, the Neutral and Ground bars ARE connected in the First panel past the Meter (and nowhere else). You DID quote the code (in code-speak) when you mentioned this but the emphasis to Not connect them was so great, we may have lost the fact that they are to be connected just past the meter. Loved the video!
@denisouellet6518
@denisouellet6518 2 года назад
You too often struggle with the wrong tools (as DIY guys often do)... what about a "new tools" series showing more appropriate tools for these jobs (no need to go crazy fancy). I always enjoy your videos 👌😄
@phillipyangmusic
@phillipyangmusic 2 года назад
thanks for sharing, I liked and submitted!
@tclucke
@tclucke 2 года назад
Same gloves I use. Best ones I've found.
@Byron88
@Byron88 Год назад
I suggest carbide holesaws designed for knockouts spring loaded and eject the slug, also just a knock-out tool makes the larger holes so much easier
@buggsy5
@buggsy5 Год назад
Yep - proper tool for the job. Knock-out punches are not expensive and make the job easy.
@kevingarvey4887
@kevingarvey4887 7 месяцев назад
Great video, and I learned a lot. I am in the process of doing the same thing but have a few more problems not covered in your video. My electric is all piped and all terminating in the top of the panel. The new panel is wider and longer than the existing panel. My primary feed conductors are short by 4" as well and the rest of the conductors will be short as well. To compound those issues, the existing panel is mounted between metal studs. I need to modify the studs in the wall to accommodate the new panel. Just an observation, when you drilled the hole for the primary feed, the wood was not flush to the top of the panel resulting in the knock-outs breaking. Thanks for sharing your knowledge.
@ElectricProAcademy
@ElectricProAcademy 7 месяцев назад
Guh, sounds TEDIOUS! Sorry to hear it. Are you a sparky or just an advanced DIYer?
@superspecialty5169
@superspecialty5169 Год назад
Oh, oh, two non word in 46 seconds, 3 more & “good by”. It’s just in my top 3 peeve’s!
@en2oh
@en2oh Год назад
your channel is beyond great! Thank your for sharing this information, even if only to help understand the difference between good and bad contractor work. I have a question related to panel replacement. I needed to have my panel upgraded (100 to 200amp service) for my Tesla charger. The solution was to simply put a primary 200amp panel in the garage to feed the original 100 amp panel in the basement (fully loaded with circuits). I'd like to off load the basement panel to use more of the 200amp service. As well, I have an inverter/battery pack in the garage that I'd like to feed some circuits in the whole house through a transfer panel. Any suggestions? My big problem is that the service stack is on the outside garage wall, with a concrete slab between it and the basement panel. I don't want to have to break the slab if there is another way. Thanks folks. Doug
@erics9213
@erics9213 Год назад
When I was a kid in the 60s, I saw the electric in an use a hack saw to cut metal BX cable ssd sheathing.
@machone1757
@machone1757 2 года назад
Use hacksaw on BX and be sure to install anti short bushings
@madman432000
@madman432000 Год назад
Replaced the original panel in my house a few years ago, it had 2 breakers(40 & 50 amp) on either side of the mains coming in, so they were not on the main breaker. A couple shared breakers, and a power shedding box above it with the range, dryer, and water heater on mercury switches. It was 200A service but only about 10 circuits available, not much bigger than the panel you have here.
@jzrgrmm
@jzrgrmm Год назад
It's funny that here in Brazil we used to have "NEMA breakers" in the past, at least everybody calls them that, but I've NEVER seen this type of "snap on" breaker in my whole life. Indeed, they look very "NEMA", but they had connections in both ends, meaning you had to energize every single breaker on the panel.
@michaeljavert4635
@michaeljavert4635 Год назад
Not happy that you have problems, however, I am glad to see I am not the only one that does. And I like seeing that it happens to an electrician so we can see how they deal with it. So there might be some slight feelings of "Schadenfreude". Not as in joy or happiness, but in some self satisfaction knowing I am not the only one that experiences these snafus. Now if I could just figure out where my screw driver walks off to, the minute I set it down, that would be one of my many problems solved. Takes me 2 hours to install one GFCI, even when the box is surface mounted and not flush because of little issues along the way, that quickly become a big headache and disappearing tools that are NO WHERE to be seen around where I was just working. Then I find out that my Romex, coated with a cloth like silver sheathing is asbestos. With my luck, I probably inhaled it and now I know why the electrician talked me out of rewiring my home after seeing it. THEY did that change order but, it favored me because I didn't have to spend $28,000 on a rewire. I plan to rewire it myself some day and I'll probably have the industrial look throughout with conduit and extension boxes over the wall boxes, as I don't plan on tearing down walls. One trick I learned when securing something with threading that's fighting you, is to use some Dawn dish soap as lubrication. It's non flammable like oil would be. I learned the hard way... Like don't spray a bug zapper with WD40 when the grid is rusted. I was 10 years old and thought I knew everything.
@thecurious6721
@thecurious6721 2 года назад
Thanks a lot! 👍🙏
@markxx90
@markxx90 2 года назад
I like your reference to the #4 or larger needing a plastic bushing, although technically I believe any size rigid pipe or connector needs a plastic bushing regardless of size. Bummed you cut out the hardest part of the video! Wanted to see how you got the panel in there with such a narrow studbay
@Nonsense62365
@Nonsense62365 Год назад
My previous house was built in 1949 its the same 1/2 (inside diameter) flexible thick walled metal conduit!
@Russianmafia10
@Russianmafia10 Год назад
Any reason you didn't take the extra minute to wrap the compromised section of insulation with some electrical tape?
@jacob9340
@jacob9340 Год назад
22:03 "You'd be bleeding out the knuckles @ this point if you're not wearing gloves" So true..
@SidebandSamurai
@SidebandSamurai 2 года назад
This was a great video demonstrating what pit falls you can encounter with such a project. Can you replace a 100 amp panel with a 200 amp panel?
@HBLOS14
@HBLOS14 8 месяцев назад
Just came off a side job doing this. I felt that when you said “ you’d be bleeding at the knuckles without gloves “ …that was me …bleeding 😢
@ElectricProAcademy
@ElectricProAcademy 8 месяцев назад
Sorry to hear it! Thanks for hanging in there anyway and getting the job done.
@sgarson
@sgarson Год назад
Excellent video. Only question is the uninsulated neutral to the other subpanel: won't it be grounded simply because it will touch the panel casing?
@steveloux4709
@steveloux4709 Год назад
"BX" is a trade name for Type AC cable. This cable type is not discontinued as you say, but Type MC cable has become vastly more popular for its dedicated copper EGC.
@ElectricProAcademy
@ElectricProAcademy Год назад
Oh very interesting! Despite the vastly varying properties of the insulation they're still calling it the same thing?
@steveloux4709
@steveloux4709 Год назад
​@@ElectricProAcademy Type AC cable is covered by Article 320. The conductors contained within can be anything listed in Table 310.4(A). Obviously the rubber-covered RH insulation within Type AC cable is unlikely to be for sale anymore, but it does not change the designation of the cable type. Type AC cable is subject to adjustment factors, de-rating, and temperature correction depending on whether it is encapsulated in insulation, and depending on the type of conductors within the interlocking tape. I would not be inclined to replace this wiring method in your house based merely on the conductor condition inside the cabinet. You have a robust cable with a first-generation ECG built in! And I would be fairly judicious in eliminating any K&T depending on its condition, proximity to insulation, and the load served. I have a little bit left in my bedroom lighting and receptacle outlets, and I'm not in any big hurry to replace it. They route back to a 120V fuse block equipped with Type S fuse adapters, and the line side of the fuse block is fed by a dual-function circuit breaker at the main panel.
@burts6896
@burts6896 Год назад
Around 20:00, the wall is made of…? lath & plaster? With drywall, I like to use a utility knife to score the outline outline early on. This gives a nice edge and prevents tearing the paper further.
@dhh488
@dhh488 6 месяцев назад
Thanks for the video. I'm two years behind, did you ever do the whole house electrical upgrade?
@brixtar
@brixtar 2 года назад
0.9mm PENTEL is my favourite pencil…always sharp and thick enough lead not to break easily.
@johnsandlinjr
@johnsandlinjr 2 года назад
By far my fav pencil.
@ItsCoolinn
@ItsCoolinn 2 года назад
I've always heard them called anti-shorts. The red head that inserts into the MC to prevent the wire from being nicked and shorted out.
@mfiels
@mfiels 2 года назад
Awesome video! Is there such a thing as an AFCI breaker that works as a replacement for a two pole breaker feeding a multi-wire branch circuit with a shared neutral and 2 hots across phases?
@exile9237
@exile9237 2 месяца назад
For a small service i believe its best to upgrade the panel with equipment having similar dimensions
@JohnThomas-lq5qp
@JohnThomas-lq5qp 2 года назад
Only wish they had the larger capacity panels ( like a 84 circuit panel ) when I upgraded my panel to a 40 circuit panel years ago. Being a sparky of course I had to run a few pieces of conduit out to feed near by washer & dryer , burglar alarm & some other circuits. Have natural gas for everything but still max'ed out the panel and ended up installing a sub panel in the garage. Have central air conditioning but ran a dedicated 20 amp receptacle under every bedroom window in case I have to throw in a window Air conditioner if the central AC took several days to be replaced. Luckily panel was on concrete basement wall so all I had to do was install a piece of 3/4" painted plywood. Hated changing panels inside of finished walls. In one area they mounted a 8 circuit main panel under a bedroom window where they had no basements. Of course they had wires entering old panel from top, bottom and 1 side.
@Multidimensionaltravel
@Multidimensionaltravel 2 года назад
Thanks!
@imark7777777
@imark7777777 Год назад
Awesome explanation about neutral and ground currents. And PS that's an inside wall shouldn't necessarily be loadbearing but not an expert.
@Sparky-it4gx
@Sparky-it4gx 2 года назад
I really enjoy seeing how other professionals in the electrical trade perform! There was one thing that concerned me at the start of your video. You talked extensively about safety of the homeowner. How about your safety while doing the work? OSAH states that when working on exposed 240V and below that the minimal PPE required is: FR long sleeve shirt, FR long pants, safety glasses, hard hat, voltage rated gloves, and voltage rated tools. I was glad to see you verify that there was no power present after turning off the breaker. You should always wear the proper PPE UNTIL you verify no voltage is present. Keep up the professional work and keep safe!
@illestofdemall13
@illestofdemall13 2 года назад
I've dealt with the aluminum Romex. That stuff sucks. Replaced everything with new copper cables.
Далее
A Master Electrician's Worst Nightmare
36:52
Просмотров 315 тыс.
Protecting My Whole Home From Electrical Surge
23:47
Просмотров 66 тыс.
ВОТ ЧТО МЫ КУПИЛИ НА ALIEXPRESS
09:35
Просмотров 475 тыс.
An Electrical Panel Installation, But Sexier
31:34
Просмотров 168 тыс.
FULL 200 AMP SERVICE UPGRADE | CLARK, NJ
51:14
Просмотров 119 тыс.
MSI сделали свой Steam Deck
12:54
Просмотров 40 тыс.