Synopsis:
Do you find yourself replacing light bulbs too often? Are you worried about your TV & appliances operating correctly for their full life? Have you noticed that your phone & computer batteries have drained significantly, despite constant charging? All of these things may be good reasons for a whole home surge protector.
In this video Joel will demonstrate 2 types of surge protectors that install directly into a home’s electrical panel to provide protection for all circuits. This is a home upgrade with significant long-term benefit, especially in tandem with surge protector strips in outlet receptacles throughout the home.
Though step-by-step and widely available, we’d rank this as an intermediate-level DIY project due to the discomfort of some when working in their electrical panel. We hope to relieve your stress during and after the installation!
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance. Got a question or ideas for a future video? Leave a comment below and submit your idea here: forms.clickup.com/f/23xa9-70/...
Thank you for watching; we value your feedback and monitor this channel daily.
Products We’d Recommend:
*EPRO endorses pro-level tools & materials, and receives a small commission for purchases through our links through Amazon & other affiliate programs. We’d be happy to recommend more cost-effective products for DIYers and low-frequency users if you engage with us in the comment section!
[] Square D QO Surgebreaker: www.homedepot.com/p/Square-D-...
[] Eaton Universal Electrical Panel Surge Protector: amzn.to/3mUJQt0
[] Square D Electrical Panel Cover Screws: amzn.to/3sWDm0t
[] Klein Tools Insulated Screwdriver Set: amzn.to/3sUNkzF
[] Neiko 1/4" Adjustable Torque Screwdriver Set: amzn.to/3kCc5ek
[] HDX Eye Protection: www.homedepot.com/p/HDX-Indoo...
[] ATG Maxiflex Nitrile Gloves: www.homedepot.com/p/ATG-MaxiF...
[] Milwaukee Wire Strippers: www.homedepot.com/p/Milwaukee...
National Electrical Code (NEC) referenced in this video:
Free Access Here: www.nfpa.org/codes-and-standa...
[] Surge Protective Devices (SPDs) 1,000+ Volts [NEC 242, Part II]
[] Surge Protection Requirements For Dwellings [NEC 230.67]
Outline:
0:00 - Introduction
1:00 - First-Look Code Violations
2:00 - Electrical Panel Cover Removal
3:50 - Types of Surge Protection & Code
4:58 - Surge Protector Placement in Panel
5:29 - Safety While Working in an Electrical Panel
8:25 - Breaker-Style Surge Protector Installation & Wiring
10:32 - Purpose & Layering of Surge Protection
14:44 - External-Style Surge Protector Mounting
19:38 - External-Style Surge Protector Wiring
Connect With Us:
Jefferson Electric services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
www.jeffersonelectricllc.com/
/ jeffersonelectric
/ jefferson-electric-llc

Наука

Опубликовано:

 

5 июн 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 178   
@MrRustyjackson
@MrRustyjackson Год назад
I've watched a number of your videos. I like the details you talk about rather than glossing over those little items that usually go unmentioned. Well done and thanks.
@mrindependent1
@mrindependent1 Год назад
As an apprentice who is soon to take his journeyman exam, this man’s videos have been priceless!! Thanks Joel!!
@christopherwishing4636
@christopherwishing4636 5 месяцев назад
I urge you to obtain Mike Holt's Journey exam prep. As it is a value that will ensure you become priceless.
@SirBrass
@SirBrass Год назад
The reason twisted pair matters with surge protection is for protection against electromagnetic interference from the other lines. That twisted pair helps cancel out possible inductive interference.
@Jutilaje
@Jutilaje Год назад
On the working space requirement, the code doesn't say the panel has to be centered within that 30" working space, and it's widely accepted that a panel can be offset 1 way or the other, as long as the panel door is able to open to 90 degrees.
@christopherwishing4636
@christopherwishing4636 5 месяцев назад
Read the code's requirements for electrical installations. Never rely upon what someones tells you or you see someone do. Know by reading the code and studying the relevant theory as to the why.
@RossWardistan
@RossWardistan 4 месяца назад
Please cite the code chapter and verse. Shuts down arguments immediately.
@PowerPlay25kV
@PowerPlay25kV Год назад
Never rack the surge protector breaker into an energized panel (as done here) without FIRST connecting the neutral wire.
@bruceirvine3962
@bruceirvine3962 Год назад
Thank you for providing this info. Surge is now on my to do list!
@michaeldunn9018
@michaeldunn9018 7 месяцев назад
Thank you for this great video! Best explanation of SPD’s and NEC issues I’ve seen yet!
@harrydoherty8299
@harrydoherty8299 Год назад
i installed the ultra with a 50 amp breat as required in the instructions. i also put the surge protector directly across the 50 amp break so that the shortest twisted wires possible.
@vince6829
@vince6829 Год назад
Thank you for sharing your knowledge. Much appreciated!
@allencar5212
@allencar5212 Год назад
Good advise on adding whole house surge protection. People protect computers and TV's with Tripp Lites but forget that almost every appliance is now "computer" controlled. I don't have much faith in the Square D QO surgebreaker. The builder installed one (in the middle of the panel - wrong location which you also explain) and I lost 7 appliance controlllers over 5 years. I installed the largest Eaton CHSPT2-Ultra Whole House Surge Protector (~$140 plus a 50amp 240V breaker) 108K amps rating on the 1st breaker in the panel. In the 7 years since its installation; no more appliances have been lost.
@jovetj
@jovetj Год назад
SquareD QO are still my favorite. Despite the big recall. I always take the top screws of the panel off last.
@michaelbeckerman7532
@michaelbeckerman7532 Год назад
This is an excellent video that provides FAR more detailed information than most other videos you find on this subject. A really well-done presentation. The devices referenced here all appear to be shunt-mode, MOV/GDT-based, sacrificial surge protectors that can only absorb so much current before they are spent and need to be replaced. Are there versions of these same devices that can be installed at the point of service and the sub-panels that use inductance-based, series-mode surge protection methods that are non-sacrificial? We see these types of products from companies like SurgeX, ZeroSurge and Brickwall for use at the device/outlet-level inside of buildings, I'm wondering if those same technologies are also available for this type of application as well?
@satoshimanabe2493
@satoshimanabe2493 2 года назад
Thanks for the video! I didn't know that QO breakers can take two wires. But does this mean that I can add a universal protector onto an existing circuit? My panel is full, so that would be helpful. BTW, two things I noticed: (1) the black wire on your stove does not appear to be stripped properly, and (2) you used a 30A breaker, but the instructions seem to recommend 15A (though I can't think of a reason you would ever want it to trip during a surge).
@krg038
@krg038 Год назад
Great install video. As I read more about panel surge protectors I also see pictures of failed (burnt panels) with surge protection. As well the manufacturer gives a dollar amount for failed surge protection. The manufacturer has yet to pay for damages. Install is one thing with great green lights and actual proven protection is another. No one seems to show the product worked. Thoughts? Your EV trench video and panel redo us great.
@chucktrotter9699
@chucktrotter9699 Год назад
10.29.22 Very good video. Thanks for taking the time to make it. Question: What if your panel is full and no room to add extra breakers? Could one stiil use some kind of external SPD connected to an existing breaker closest to then main power coming in?
@michaelbedell6523
@michaelbedell6523 Год назад
You are the coolest electrician I’ve ever come across. Great presentation to get insight on how and why surge protection at the source and down stream are beneficial.
@kenlgraham
@kenlgraham Год назад
Good video, however we have a square D surge breaker and I can say with certainty they do not help with brownouts. We had a outage where our computer UPS showed a continuing voltage of 70 volts and lost Microwave, TV, LG Washer electronic board. However all items on brownout protectors that shut off at around 90 volts and stayed off for 3 minutes after power was restored survived so I have about 18 more of those brownout surge protection devices now. Thus I agree with layered protection but suggest it include brownout protection. It is unfortunate a whole house brownout protector is available that includes time delay restart.
@altep8148
@altep8148 Год назад
Great Video and detailed explanation. It looks like my Square D panel is the same as yours. Can you use the Square D SPD listed below? How would I know if I have a Plug-on Neutral panel? Square D QO 50 kA Plug-On Neutral Whole House Surge Protective Device. Thank You
@thedabbler2753
@thedabbler2753 Год назад
I have a 100A panel I'd to add a surge protector to. Unfortunately it's a) flush to the wall and b) uses old CH breakers, otherwise I'd just add an in breaker one such as the one by GE (which says it needs their panel so I guess I can't use it). As such, I've looked at the Eaton CHSPT2SURGE but there is no space inside the panel and I can't leave it in the wall cavity. If I went the Eaton route, what sort of conduit / parts would you recommend that I could break out from the wall and surface mount the SPD and be code compliant? If there's an easier way I'm all ears.
@jd415
@jd415 Год назад
Amazing video!! Watch out Electrician-U, this guy is coming for you!
@ranger178
@ranger178 Год назад
can you buy those plastic covers for the main lugs like they have on new panels I have the same panel at my house
@Handsome347
@Handsome347 6 месяцев назад
Thanks for a video! For myself siemens fs140
@ranger178
@ranger178 Год назад
If the lights are still on those surge protectors are still good? is there a lifespan mine is around 27 years old but lights are still lit
@jameskappel
@jameskappel Год назад
Hello Electric Pro Academy, power conditioner something to consider or recommendation or snake oil? Thank you.
@MrKen59
@MrKen59 Год назад
I was not able to use a space near the source without major surgery so I used the only space that was open which was near bottom. Truth be told, the response of the varistor is far slower than any time along a bus. Also, Siemens makes a dual 20 amp breaker that includes whole house surge so you don’t loose any spaces. I have a CH panel and all the top spaces are 240v and I don’t think Eaton makes a combo surge/breaker.
@ElectricProAcademy
@ElectricProAcademy Год назад
Ooo, can you share a link of that breaker?
@tomm8775
@tomm8775 Год назад
Thanks for the video. I have a Cutler Hammer panel That is seated between studs and surrounded by drywall. My understanding is to avoid interior panel mounts yet this panel cover has a knockout that is perfectly sized for my SPD at the top of the breakers. The two pole breaker that the unit will wire to is going to be at the very bottom near the inbound supply. I’m trying to minimize the wiring run but there doesn’t seem to be any other option than to have this mounted at the knockout position inside. Just wondered what your take is on the whole interior mounting thing. What’s the real downside versus mounting it just on the outside of the panel?
@harrydoherty8299
@harrydoherty8299 Год назад
give the breaker next to the main shut off. mount the surge protector outside the panel near the breaker and ground / neutral bus . thus keeping the wires as short as possible
@Trainman0401
@Trainman0401 2 месяца назад
If I install a surge protector in my subpanel then would you recommend installing another one at my mini split heat pump disconnect? I think the answer is yes from what I learned from your video. Thanks for sharing your knowledge.
@alanklipp9305
@alanklipp9305 8 месяцев назад
Excellent. Well done.😊
@wisdomwisdom817
@wisdomwisdom817 Год назад
Wonderful job thank you so much
@mrindependent1
@mrindependent1 3 месяца назад
Joel, what are your thoughts on using ferrules for stranded wires on your breakers? Do you ever use them? I’ve recently started using them. Seems to make a better connection. I use a crimper. But I don’t see them used often by other people and wondering if you have any experience.
@chrisruss7863
@chrisruss7863 Год назад
NEC 110.26(A)(2) The width of the working space in front of the electrical equipment shall be the width of the equipment or 762 mm (30 in.), whichever is greater. In all cases, the work space shall permit at least a 90 degree opening of equipment doors or hinged panels. Code does not state 15" being necessary to have left to right of the panel. You could have 1 inch to one side, 29 to the other side, and as long as the door is able to open 90 degrees or more it is not a violation. 15" is a good practice, but not listed in the NEC. In addition you stated you were using insulated tools, and then proceeded to tighten the terminal down with a tool that was not insulated. Now it is more than likely you will not get shocked on the handle, but the tool was never tested as insulated, is marked as uninsulated, and the shank of the screwdriver has no insulation or protection which is a requirement on insulated tools. I would definitely be careful with the language used, as someone assuming that just because a tool has the Klein name it is insulated could be a huge hazard for your viewers.
@chrisruss7863
@chrisruss7863 Год назад
@@ElectricProAcademy thank you my friend! Absolutely love your videos I've been binge watching them for days now :)
@csimet
@csimet 2 года назад
Great video... I did not know they were available in a simple breaker configuration (I always thought they were installed outside the panel). I'm picking one up today to install while I have the panel open to put in my new breakers. I see that Siemens even makes one that has two built in 20 breakers to save space and not eat up two extra positions (QSA2020SPD). Tx!
@robinfranzel4403
@robinfranzel4403 Год назад
Thanks for a great video, Joel! I will put an SPD on my panel shortly. (Not sure if I should go with the 108 kA or 36 kA device.) My house construction was finished in November 2020 and my neighbor's in 2022, and neither of us have an SPD on our service panels as required by NEC 230.67. When are electricians supposed to start following new code requirements?
@ElectricProAcademy
@ElectricProAcademy Год назад
All comes down to your AHJ, but Indy is currently in the process of transitioning from the 2008 NEC, which doesn't require SPD, to 2020 NEC, which does
@cquintana9326
@cquintana9326 9 месяцев назад
Are you saying the inside panel is a subpanel? Even though the outside main single breaker is just used for on/off for the inside panel?
@thenexthobby
@thenexthobby Год назад
If I'm understanding correctly, what these panel surge protectors do is shunt excessive supply voltage to neutral, re-establishing the ideal phase balance temporarily, until the utility company stops sending the surge. Is that correct?
@DIY_GuyNJ7
@DIY_GuyNJ7 2 года назад
So which device is best to have installed? Or is it both?
@JrGetty
@JrGetty Год назад
No surge yet andLED’s flicker sometimes. I’ll see if it helps thanks .
@johnschilling9211
@johnschilling9211 2 года назад
What is the torque screw driver that you use?
@MRSOSERIOUS7416
@MRSOSERIOUS7416 Год назад
In Minnesota alot of people just use surge protection extension plugs
@MrRerod
@MrRerod Год назад
Great video! I don't have a surge protector and replaced a SL22 thermistor in the ecm blower motor module of my two stage furnace a couple years ago. Did the thermistor burn because I don't? And second.. I don't have room in my breaker panel for a surge protector breaker and probably shouldn't put it in the sub panel. Can I protect my furnace with a device in the furnace? Or should I go the whole nine yards and replace my main panel? Thanks
@ElectricProAcademy
@ElectricProAcademy Год назад
It's quite probable that every premature failure of an electronic component in your house could be connected to small consistent or large occasional surges. Your options include: 1. Use tandem/space saving breakers in your panel if allowed by the panel listing (see inside cover of panel) 2. Land a "non-breaker style" surge device to your breaker if the breaker is rated for two conductors (see breaker data sheet) 3. Combine two loads, investigation and discretion required (there are codes that limit this). Here's a tip on how ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-tF4sVKf_D34.html 4. Use an SPD rated for the service equipment and locate it in your external disconnect (advanced solution)
@timlist4173
@timlist4173 3 месяца назад
So, how do you determine the size of spd you need?
@christopherwishing4636
@christopherwishing4636 5 месяцев назад
Site specific articles relating to each task including the reasons that a code change has been adopted. Always begin with the purpose of the code: "To protect life, and property from the hazards of the use of electricity." Omit all references pertaining to utilities.
@argekay1960
@argekay1960 Год назад
I do not know what your definition of insulated tool is however that flathead screwdriver was NOT insulated. It had an exposed conductive shaft. Electrical tools that are rated to work live specifically state the voltage rating (typically 1000v for the systems we are likely to encounter). You owe it to your viewers to be concise and truthful.
@ronbishop5609
@ronbishop5609 Год назад
The HANDLE was insulated.
@mikemccarthy6939
@mikemccarthy6939 4 месяца назад
Is that code used in Texas for surge protection I just bought a new house no surge protection
@mhavock
@mhavock Год назад
Nice video! Can you comment how a 30amp or 15amp fuse on the surge protector is going to allow a 200 amp panel to access its full current? I might have missed something or need to do research; Does the fuse hooked to the surge protector get tripped only by the surge protect, eg 100 amp can go thru it on normal usage but if the surge protector see a spike it trips the fuse? Thanks!
@ronaldwojtylko4375
@ronaldwojtylko4375 Год назад
The way that a surge protection device works is that it provides a short to ground for voltages over a certain limit (the clamping value). This is a fairly low current event (usually around 8 amps for a very short duration but can be higher). There are different types of SPD's, typical cheap power strips and some $30-$100 panel units, use MOV's (metal oxide varistors) wired between the hot and ground, this are disc like devices that actually breakdown at a certain voltage, this breakdown is destructive and you only get so many events before the MOV shorts out and and self destructs. After the damage occurs, you have a good power strip but not a surge arrestor. The other type is a gas tube device, these can take thousands of events and are self resetting. Devices with these can get pricey. We use these at the base of cell towers between the antennas and the very expensive cellular equipment and they handle direct lightning strikes. In a nutshell, a good SPD with gas tube will cost more, but you will probably only have to install it once. As to using multiple units, the only thing this does for you is that when the one closest to service fries, you still have protection. The electrician's assertion that downstream units will share the surge is not true, if the first one clamps above a certain voltage, then subsequent units will not see that clamping voltage and therefore they will do nothing. But as I said, having them there will provide protection if the first one fails. He is not joking, people have no idea that surges are shortening the lifespan of everything from LED lightbulbs to refrigerators and that things like refrigerators and air conditioners (inductive motor loads) also cause surges when the shut down. All of this "noise" takes it's toll over time.
@mhavock
@mhavock Год назад
@@ronaldwojtylko4375 Hi, and thank you for a detailed explanation. It also makes me curios about the short to ground that you mention in general. What do you mean by short to ground? In an AC panel does the ground be come the source as the current alternates, and limit the current and voltage also? Also is there some form or resistance always on the line (as a safety) to limit the max current flow (eg maybe on the line side before service comes to the location)? Thanks again!
@petercampbell4220
@petercampbell4220 Год назад
The fuse is a wire. Like any wire it can carry currents for a time. Like 4/0 protective grounds are good for around 40,000 amps for 15 cycles, and 20,000 amps for 30 cycles, prior to burn open aka fusing. So current times time -so 100,000 amps for 0.001 cycles will easily pass through fuses and breakers. A direct lightning stroke will blow the entire panel and everything connected. 2,000,000 amps for 1 cycle time?
@jovetj
@jovetj Год назад
@@ronaldwojtylko4375 Excellent description of how different types of surge protection operate.
@jovetj
@jovetj Год назад
@@mhavock You can think of a Metal Oxide Varisitor (MOV) as a _resistor_ (a discreet device designed to allow current to flow at a controlled rate) whose amount of resistance is indirectly proportional to voltage across it. Most surge devices have one or more MOVs connected across hot(s) and neutral and hot(s) and ground. At normal voltages, such as 120 or 240 volts, the MOVs are very high resistance, and little to no current goes through them. But, when a voltage spike comes along, especially above the MOV's rated "clamp" voltage, the MOV's resistance drops very low. This "shorts" the high voltage to ground. If the MOV survives the short, it will return to high resistance once the voltage drops back to normal. As Ronald mentioned above, such an event is usually still damaging to the MOV and multiple small surges can destroy it. The size and duration and total power of the surge that the MOV(s) has to handle (versus its design specs) determines how long it will last. "Short to ground" means diverted to the grounding system, or the _groundING conductor._ Remember that the typical US home electrical service has four wires: 1. Hot #1 (usually black) 2. Neutral (white) 3. Hot #2 (black or red) 4. Ground (bare or green). The ground wire, or _groundING conductor,_ is the safety wire that is used in all modern wiring. It's connected to the metal chassis of devices to ensure they're grounded. The ground wire is electrically connected to the Earth to ensure it shares the same voltage potential as the Earth. At the main disconnect, the ground wire is also connected to the neutral (the groundED conductor). This ensures that the neutral also has the same potential as the Earth, which makes it safer to humans since they walk on the earth, and also allows the grounding system to find a low-resistance path back to the power source. In turn, should a metal chassis become energized through accidental connection to a "hot", an alternate circuit will be created between the hot and ground wire which will cause a short that will quickly trip the breaker or fuse. The whole point of "short to ground" is to dissipate or cancel out the extra voltage before it reaches any of the circuitry further on. Unless you are dealing with superconductors, every wire acts as a resistor-that is just the laws of physics. The flow of electric current is subtly resisted by the conductor and is manifested as heat. Each substance has its own degree of acting as a better conductor or better insulator, but these properties also depend on temperature and voltage. Increasing temperature or voltage improves most any substance's ability to conduct electricity. Utility lines do have fuses to isolate and protect different circuits and also surge protectors.
@charlesmiller7861
@charlesmiller7861 Год назад
Great video, But just how does the Eaton actually work, Its trys to stop surge, but how does it do that. If lighting hits close enough, it does not matter what kind of protector you have.
@ElectricProAcademy
@ElectricProAcademy Год назад
www.dell.com/support/kbdoc/en-ie/000145629/information-about-surge-protectors-and-how-they-work-kb-article-120517#:~:text=local%20power%20provider.-,How%20Does%20a%20Surge%20Protector%20Work%3F,the%20excess%20current%20to%20ground.
@Guillotines_For_Globalists
@Guillotines_For_Globalists Год назад
How does the 15" working room translate to a recessed panel behind drywall?
@Guillotines_For_Globalists
@Guillotines_For_Globalists Год назад
@@ElectricProAcademy Many homes have them installed that way if in a garage. Same with the sub-panel you replaced in your home in another video. The cover is essentially flush with drywall.
@ChaplainDaveSparks
@ChaplainDaveSparks 3 месяца назад
Is there anything you would recommend for a *_TENANT_* who doesn't own or have permission to modify the electrical panel, other than just a _secondary_ surge protector to protect electronics? BTW, the angles on bending/twisting wires *CAN* be important at higher voltages (like during a lightning strike). Twisting wires can also add some slight inductance which I would *GUESS* might be helpful in blocking an electro-magnetic pulse (EMP).
@MrKen59
@MrKen59 Год назад
Question - are there any methods of protecting a home from a sudden break in the neutral or damage from the utility? My mother in law lost a bunch of appliances when a dump truck hit the line outside. I get how the surge protector uses varistor to clamp voltage spikes but I’m not sure it will save you from this.
@ElectricProAcademy
@ElectricProAcademy Год назад
A customer actually told one of our guys recently that in a similar catastrophic event, the surge protector split in 2 but only 1 outlet receptacle was fried in the house! We may try to get him in front of a camera...
@AnthonyFarrer_TPG
@AnthonyFarrer_TPG 10 месяцев назад
What’s the difference between this surge protection and the ultra?
@Dennis-ys8ho
@Dennis-ys8ho 11 месяцев назад
Hey Joel: I just watched this video. As with all of your videos, I learned a bunch of new stuff. You are a rock star! Anyway … My main Murray panel has a Siemens QSA2020SPD circuit breaker/surge arrestor. My Crouse-Hinds sub panel has no protection … and also no spaces left. I do have a double pole 30amp breaker for a 240 volt garage heater (10/2 Romex). Can the Eaton CHSPT2SURGE you referenced in the video somehow be used in conjunction with this breaker?
@ElectricProAcademy
@ElectricProAcademy 11 месяцев назад
Many thanks! Firstly, the SPD in your main panel is providing protection to your sub panel. If you'd still like to get an SPD in your sub the consider whether your breaker is only rated for 1 terminal per lug. If so then, allowed by many jurisdictions but not all, you can pigtail off your breaker and junction to your load and SPD leads inside or adjacent to your sub panel within an enclosure.
@Dennis-ys8ho
@Dennis-ys8ho 11 месяцев назад
@@ElectricProAcademy Thank you for your timely reply, Joel. A happy and safe July 4th to you and your large family! I am almost certain that you said an SPD has to be provided at each “level?” If the SPD I have in the main panel covers the sub-panel then I am good with that. For my edification, how do you tell if breaker allows more than one wire per lug?
@gatsbylight4766
@gatsbylight4766 6 месяцев назад
*QUESTION:* An electrical surge is a *physical* phenomenon, in the same way that the amount of power in a battery is a physical phenomenon. A battery with *6 amp hours* of energy will be *larger* than a 2 Ah battery - the laws of physics dictates this. My question is: Are circuit breaker surge protectors inferior to standalone surge protectors since the circuit breakers are not only smaller than an externally mounted SPD, but remember that the circuit breaker components take up a lot of space inside the circuit breaker (obviously), which leaves even less room for the physical components which protect from surges. The laws of physics certainly must dictate that the level of surge protection is directly related to the size of the physical components that "absorb" the surge. Yes?
@jankuehl4207
@jankuehl4207 2 года назад
Surge protection: Best wiring practice? If an appliance (Dishwasher) requires 13.5 Amps or less. Is it best to use the minimum code: 15A, 14Awg circuit and wire, or to upgrade (Future Proof) to 20A,12Awg circuit and wire. If a surge should occur does the 15A or 20A circuit provide more protection to the Dishwasher? Does the smaller 15A circuit provide better Appliance protection by limiting the current and amperage from breaker to Device?
@jovetj
@jovetj Год назад
Also remember that circuits are commonly thought-derated to 80% of their ampacity. 13.5 amps is greater than the ( 80% of 15A = *12A* ) continuous expected ampacity of a 15 amp circuit. Right, Joel?
@RB-nm3ko
@RB-nm3ko Год назад
While a voltage surge is considered an issue, how does this relate to amps? Isn't it amps that would eventually infiltrate devices and wreck them or could it be said that if voltage meets little resistance then the amps would almost equal the voltage? Thanks
@jovetj
@jovetj Год назад
Keep in mind that: watts (power) = volts × amps To compare to water: gallons_per_minute = pressure × capacity_of_tube If the pressure in your home's plumbing is 40 psi... and a sudden surge of 4000 psi enters your home, some pipes are going to explode. Voltage spikes literally burn out delicate circuits such as electronics that cannot handle the voltage. The instantaneous amperage passing through doesn't exactly matter because the _power_ going through is more than the device can bear. The device is damaged, and will either fail instantly or slowly degrade over time until it does fail. Another thing that equation above tells us is that voltage and amperage are inversely proportional for the same amount of power. While keeping power constant, reducing the voltage increases the amperage, and vice-versa. Power lines are such high voltages so that the conductors can be small enough to be practical while still delivering the desired amount of total raw power.
@xjm40
@xjm40 4 месяца назад
This old house has a kitchen light switch with load line in and load out that's it. No neutral and no ground. Help
@jeff245245
@jeff245245 Год назад
Question, you said that the breaker can have two conductors under the terminal, could you have left the range breaker in place and added that surge suppressor? I was told no before and wondering what you think?
@jovetj
@jovetj Год назад
No. Surge protectors like this need their own individual circuit breaker that serves nothing else.
@jeff245245
@jeff245245 Год назад
@@jovetj Thank you for the response I was thinking that since you did put it in own breaker but was not sure
@rb8049
@rb8049 Год назад
50A is plenty for an EV. For 5 EVs you can service them with 200A with Tesla wall connectors which share. You don’t need to charge all the cars at the same time the whole night. This is crazy. In addition to panel surge protectors, and APS with surge protection on each computer and router.
@outlet6989
@outlet6989 Год назад
The last time I tried to hold a panel cover with my shoulder, it fell on my foot. Ouch! I like to watch electrical-themed videos where I learn about codes. My house is 35 years old. I have seen many examples of work that do not seem to pass the current regulation. If this work was done many years ago, am I covered by some form of 'grandfather' clause.' My electric company offered me an option to have a whole-house surge protector installed. The electric company replaced the meter with a surge protector type. Is my whole house now surge-protected? BTW, my electric bill shows a 'Surge' fee.
@anthonymickle4103
@anthonymickle4103 18 дней назад
Ain't no electrician that never got shocked...
@jovetj
@jovetj Год назад
I'm a bit disturbed that the LED indicator on the in-panel surge device lit up before the neutral was connected to the bus.
@rlvtrader
@rlvtrader Год назад
Great video. I know you know what your doing, but man I can't help but wince in fear when you are messing with the live panel.
@ElectricProAcademy
@ElectricProAcademy Год назад
Very fair. We highly endorse killing power whenever possible.
@Ryan-ji6wk
@Ryan-ji6wk 16 дней назад
What's the benefit of using a power conditioner as well? What is it? Is it worth it?
@christopherwishing4636
@christopherwishing4636 5 месяцев назад
The Klein screwdriver you are using is not an insulated tool. The handle is designed for comfort and fatigue reduction.
@picklerix6162
@picklerix6162 2 месяца назад
That $50 whole house surge protector now costs $94. I paid $47 when I installed mine.
@christopherwishing4636
@christopherwishing4636 5 месяцев назад
And simply state that the surge protective device be installed per instructions as the code requires.
@SteveStowell
@SteveStowell 9 месяцев назад
There are shareable EV charging solutions. You can easily charge 5 - 15 vehicles easily on one 50 amp circuit.
@HappyDiscoDeath
@HappyDiscoDeath Год назад
Jeez, landline Cat 3 grey jacketed telephone wiring (and 66 blocks) isn't that old. "Old" would be like a phone I have that predates rotary dialing. (it has no dial)
@christopherwishing4636
@christopherwishing4636 5 месяцев назад
I am a Fifty plus year master and retired instructor. Stay on the journey...
@karlfife
@karlfife Год назад
IMO the surge protector should only live INSIDE the metal enclosure of the load center. A longer-duration surge (non transient, such as a neutral fault) can cause the SPD to pass more power than it can handle (more than it can dissipate the heat for/of), and literally burn. You definitely don't want a smoldering/burning thing outside your panel (e.g. on that plywood backer board). l wish SPDs could be coupled with a shunt trip main breaker to disconnect the entire pane for these types of surges that it can't protect from. Instead, some have famously failed to protect while burning down the house (Sycom).
@karlfife
@karlfife Год назад
​@@ElectricProAcademy Yeah, it's a big deal. I'm not an expert in SPD design, and maybe not all SPDs fail in an unsafe way (e.g. can't catch fire due to overloading because they have been carefully designed with internal fusing etc), but open neutrals definitely create an overload condition for SPDs, so you're definitely relying solely on any safety features the SPD has (or doesn't have). As you know, open neutrals are dangerous enough, and are enough of a foreseeable event (tree falling, improper ground rod etc.) that it seems kind of a shame that SPDs offer zero protection for this event, when they could so easily do so.
@rickwatkins3085
@rickwatkins3085 Год назад
Surge protection is mandated under the 2020NEC, Indiana is under the 2008 NEC, how is this mandated in Indiana?
@mnleber
@mnleber Год назад
Canadian code requires that power be removed before working a device in this case a panel. In this case you have a live panel. Also you are not wearing approved arc fault clothing.
@Mike1614b
@Mike1614b Год назад
He takes far too many chances. I hope he doesn't get injured.
@jovetj
@jovetj Год назад
Is 240V arc fault anything to compare to a _real_ power arc fault?
@jimk301
@jimk301 Год назад
Greetings Joe, Enjoyed your video. I have a couple questions that you might be able to shed some light on. There are various Surge Protection Device (SPD) Type levels, 1, 2, etc.. I am interested in Type 2 & 1. Briefly, Type 2 is for the load side of the electrical box and Type 1 is typical for for the Utility side installations; I think the Type 1 can be used for the Type 2 load side as well. Do normal residential electrical panels have the capability to incorporate, in series in the panel, a Type 1 SPD before the MAINS breakers in the panel. If so, why would it be necessary to install a Type 2 SPD in the panel when the meter is on the outside meter 8" away. Couldn't the Type 1 perform both the functions of Type 1 and Type 2? Lastly, isn't there a minimum distance required for installing SPDs? Too close together could have the the Utility side SPD surge take out the loadside SPD? Thanks for your insights :^)
@jovetj
@jovetj Год назад
_“I think the Type 1 can be used for the Type 2 load side as well.”_ I don't think so. The electric utility owns the meter and controls access inside the meter enclosure, but all the rest belongs to the customer. "Utility" surge devices could include a surge-protecting meter, but could also be on the utility pole or pad transformer.
@christopherwishing4636
@christopherwishing4636 5 месяцев назад
And you should mention that when grounding and bonding 90 percent of fault current is carried by the neutral back to the source. Always do the math!
@js6159
@js6159 Год назад
Great informative videos, easy to understand. But please…do not wear rings or jewelry when doing electrical work- even if power is off.
@mcloude1
@mcloude1 Год назад
Is there any difference between breaker type vs regular breaker and 1 that sits outside of panel
@jovetj
@jovetj Год назад
Can you be more specific? Not sure what you mean.
@mcloude1
@mcloude1 Год назад
@@jovetj in the video the 1st 1 is breaker type spd and the 2nd 1 being regular breaker/ spd on outside of panel just wondering if there is a difference between the 2 in protection wise
@jovetj
@jovetj Год назад
@@mcloude1 Not really. The external surge devices can be more robust since they can be larger than a circuit breaker space. It really comes down to the specs an individual device is designed around. The more surge current it can handle, the better.
@mcloude1
@mcloude1 Год назад
@@jovetj thank you for ur help am going with 1 outside the panel the eaton chspt2ultra has higher Ka then the breaker style 1 from eaton
@jeffreysmith6611
@jeffreysmith6611 9 месяцев назад
Why take a chance? really, no insulated gloves, working with a live box? even a master will get complacent at some point! The teaching aspect with explainations was one of the most complete on surges and main vs sub panel installation that I've watched so far!
@bjornahh87
@bjornahh87 Год назад
hwat if that customer needs a replacement cabinet then u cannot use that surgeprotector on a new subpanel sice you cut the cable that short... not a negative comment just an observation.. love your videos btw..
@christopherwishing4636
@christopherwishing4636 5 месяцев назад
Surge protection is a requirement as types 1 or 2.
@nancyhentschel815
@nancyhentschel815 9 месяцев назад
Could flickering lights mean I needed a surge protector?
@MosinMan76254
@MosinMan76254 8 месяцев назад
Perhaps a loose connection in the neutral.
@rogerdevero8726
@rogerdevero8726 10 месяцев назад
Joel, I've seen about every electrical video, and you give the VERY BEST overall explanation of the process. You have a fine teaching ability. Kudos and Thank You - John 3:16
@michaeljavert4635
@michaeljavert4635 Год назад
You might have a "Grandfather" clause which means, at least in my area, is that if a house was built during the time that a specific violation was allowed, that you do not have to address it. That's how I got "bit" buying this house, not realizing there was no grounding outlets and only seeing 4 cloth Romex cables, with everything else being more modern, not realizing that the idiot that put the wiring in, cut all the grounds out of the wires, when he could have easily grounded them. It is as if he doesn't believe in ground wires or something, and it's made nothing but a big headache and grief for me. At least MOST of the electrical and gang boxes are metal and not that awful plastic, so If I can at least get those bonded to a ground wire, I have some protections. All the outlets I buy, the yoke and ground hole and plate screw all have continuity so even if a grounding outlet was installed, but no ground wire, if the metal box was grounded, there would still be ground protection. Unfortunately, that wasn't the case here, and the crooked realtor cited the "Grandfather" clause. I go out of my way to not have LED bulbs. I hate the damn things. Yes, I have been shocked before. When I was a kid, maybe 3 or 4, yes, I remember that, I used to take the bulb out of my nightlight and stick my finger in there. After about the third time, and my arm feeling tingly, I got the idea to not do that anymore. I didn't soon forget that feeling either. Another time, I was poking around a power supply, that was not plugged in. I touched a capacitor lead with a non insulated screw driver and it accidentally touched the housing. Got a big spark, a loud pop, and a lot of pain and I was stunned for several minutes. Another time, I was working with a fuse box in my car and got burned... I am betting you have been shocked before. Also, an inexperienced person should ABSOLUTELY NOT be in their panel. The horrors I have in this house, the person was not qualified to change a light bulb.
@Doug-gp2qw
@Doug-gp2qw Год назад
For the DIYers watching this, he is being extremely reckless in working with a hot panel. He has gloves that are not electrically rated, with missing fingertips, etc. There can be wires in there that might have nicks or split insulation. He tightened screws on a hot breaker. If you are not sure about a box or panel, work with one hand behind your back and don't lean on anything that's a potential ground (panel box, water pipes, etc).
@petercampbell4220
@petercampbell4220 Год назад
Things that are an owww that is live on residential, rarely kills. Some guys do roll snake eyes. When you move to commercial, 480/277 there are no learning experiences, that do not result in injury or death. The ones thst die are the seasoned residetial electricians that go to commercial or industrial. Nuclear code will allow the designer to burn down a small fault to maintain power to important equipment. The electrian can be the small fault.
@Doug-gp2qw
@Doug-gp2qw Год назад
@@petercampbell4220 Personally I have never felt more than a slight tingle when accidently touching a live 120v wire. But when working around a potentially live circuit I make sure I am not grounded. If I would have been gripping a grounded box or pipe with the other hand when I touched a live wire the shock would have been far more severe. DIYers and new electricians should learn to recognize the tingle as a potentially deadly situation if they happen to ground themselves.
@jovetj
@jovetj Год назад
@@Doug-gp2qw The best protection is to shut off the power, and test to make sure it's off. A lot harder to get shocked on a dead line. (Unless you're a utility line worker.) It's no different than getting hit by a train. Stay off the railroad tracks, and you won't get hit by a train. It's a pretty simple concept.
@bp9854
@bp9854 Год назад
🥱🥱🥱
@timcbollin
@timcbollin Год назад
A lot of comments here from people who have obviously never worked in the electrical trades. Yes, you should always observe all safety rules. However, there are times when you cannot denergize a building or panel.
@kurpal8904
@kurpal8904 Год назад
How much does it usually cost for the parts and labor from a electrician?
@mikemccarthy6939
@mikemccarthy6939 4 месяца назад
Just hired a electrician 750 dollars
@mikemccarthy6939
@mikemccarthy6939 4 месяца назад
It’s worth it
@kurpal8904
@kurpal8904 Год назад
I was quoted $250, is this reasonable?
@JoseRodriguezFrio
@JoseRodriguezFrio 4 месяца назад
Even a big squirrel lmmaaoooo
@MoonbeamAcres
@MoonbeamAcres Месяц назад
Why can't we save your video's for later reference? There's no save button available above.
@ElectricProAcademy
@ElectricProAcademy Месяц назад
It appears in the 3-dot menu next to the "Share" button for us.
@MoonbeamAcres
@MoonbeamAcres Месяц назад
@@ElectricProAcademy THANK YOU SO MUCH!!! I really appreciate it!
@michaelbedell6523
@michaelbedell6523 Год назад
Great job to convince me to hire a professional that I will spend some of my kid’s inheritance, LOL
@timmark4190
@timmark4190 8 месяцев назад
Why cant you connect neutral and ground on the same screw?
@ElectricProAcademy
@ElectricProAcademy 8 месяцев назад
Neutral and ground are 2 different electrical paths and destinations. One is "seeking" to correct imbalance within the grid, and 1 is "seeking" to correct the imbalance with the earth. By connecting both, the electrical paths will both behave inconsistently, driving up cost, resistance, and danger.
@timmark4190
@timmark4190 8 месяцев назад
@@ElectricProAcademy In some panels I have seen only one. So what do you do?
@ElectricProAcademy
@ElectricProAcademy 5 месяцев назад
Buy a ground bar from the manufacturer and screw it into the panel casing. There are normally several pre-drilled spots to choose from.
@buddyadelsberger5083
@buddyadelsberger5083 Год назад
must be a millionair if getting 5 telsas
@arthendrickson4860
@arthendrickson4860 2 года назад
Have you ever been shocked before?
@christopherwishing4636
@christopherwishing4636 5 месяцев назад
Instruction is not entertainment. A good instructor is engaging... Not a comic.
@slickrx6908
@slickrx6908 Год назад
Wow he was really flexing about his home. Wow 8000 square feet. Gotta reconsider my career choices.
@simbatortie9684
@simbatortie9684 Год назад
You are a very geeky electrician, even tighten and loosen, tighten and loosen ...etc, I've seen. LOL!!
@helmanfrow
@helmanfrow Год назад
20:00 FERRULES!
@helmanfrow
@helmanfrow Год назад
@@ElectricProAcademy Okay, I retract that. I panicked a little when you said the wire was finely stranded, but upon reflection I realize that pretty much every circuit breaker these days uses clamp terminals and not set screws. BUT if you do find yourself needing to seat a finely-stranded conductor under a set screw then please use a ferrule otherwise the screw will tear up the strands, deform the conductor and create an unreliable or even unsafe connection.
@jovetj
@jovetj Год назад
@@helmanfrow Ferrules are quite the European thing.
@davidpierre8465
@davidpierre8465 Год назад
My Brother, need to wear a hot suit when you going to work in a hot panel.
@JohnThomas-lq5qp
@JohnThomas-lq5qp Год назад
Do not need what you call a hot suit for 120/240 volt panels but approved PPE. We always used a 11Cal long sleeve shirt and a 11 Cal blue jeans along with hard hat w/ tinted visor and ear plugs . Had heavy 40 & 50CAL suites for switching & racking 13,200 volt equipment. Only good thing high Cal jump bags had hard hats with a battery operated cooling fan. Too many guys do not bother sending their 600 & 15,000 volt rubber & canvas gloves out to be tested every 6 months.
@vcubed7275
@vcubed7275 Год назад
8000 sqft? That is no house, sir. It is a mansion.
@Youcanthandleme319
@Youcanthandleme319 Год назад
You could make a cover & gasket. Not that you want to or it recommended but you totally could with new cover, gasket material & tap
@jovetj
@jovetj Год назад
8 kids??? Now we know what you do in your off time 😛
@donkeyearrs
@donkeyearrs 4 месяца назад
8000k home?
@christopherwishing4636
@christopherwishing4636 5 месяцев назад
An electrician's life is the code, never omit it, and ever reference it.
Далее
The Best Smart Sub-Panel We've Ever Installed
22:17
Просмотров 50 тыс.
Recommended Whole House Surge Protectors
11:13
Просмотров 81 тыс.
This Old Panel had WAY TOO MANY Circuits!
33:11
Просмотров 18 тыс.
Where Should We Be Using Dual Function Breakers?
15:32
Просмотров 101 тыс.
КАК НАЧАТЬ ПОНИМАТЬ LINUX (2024)
21:10
КАК НАЧАТЬ ПОНИМАТЬ LINUX (2024)
21:10
Полезные программы для Windows
0:56