Returning To The System With High Head Pressures to Replace Liquid Line! 

HVAC GUY
Подписаться 64 тыс.
Просмотров 26 тыс.
50% 1

In this video I return to the house with high head pressures in heat to replace the liquid line. #airconditioner #hvactechnician #hvaclife #hvacguy #hvac #acrepair #hvacinstall #hvactech #heatpump #furnace #lineset ‪@ruud‬ ‪@MilwaukeeTool‬ ‪@FieldpieceProducts‬ ‪@VetoProPacToolBags‬ ‪@KleinToolsVideo‬
Thrive Marketing: thrivehvac.com...
Merch Store : hvac-guy-2.cre...
HVAC LIFE FB Group: / 521086622906115
Here are links to the tools I use, And it costs you nothing extra to buy from this list:
Decked Storage System: amzn.to/3CPVeyq
Yellow Jacket 60278 Flaring Tool: amzn.to/3FPjlyY
Veto Pro Pac Tech MCT Blackout: Amzn.to/3iCieJK
DeWalt work table: amzn.to/3fKChoB
Inficon D-tek Stratus: amzn.to/3zNg7IO
3 Amp Lil’ Popper: amzn.to/3D5lt3e
Inficon D-Tek Stratus: amzn.to/3RvnXOl
Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
Fildpiece SVG3 Vacuum Gauge: amzn.to/3udursu
Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
Fieldpiece Blutooth Scale: amzn.to/3Gzveab
Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
Fieldpiece MR45 Recovery Machine: amzn.to/3cUFX5h
Fieldpiece 8CFM VP87 Vacuum Pump: amzn.to/3qC2wA2
Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
Milwaukee M12 Impact Driver: amzn.to/37xXkqk
Makita XDT16: amzn.to/3riXuaJ
Makita 18V Light: amzn.to/3Fw4GW4
Makita Wet/Dry Vacuum : amzn.to/3tw4dAL
Makita 18V Battery Mounts in Van : amzn.to/3GxpVID
Makita Jobsite Radio: amzn.to/3HuVp2u
DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
Klein Knee Pad: amzn.to/3cy6FB0
Klein 7in1 Flip Socket: amzn.to/3bpabwG
Klein Journeyman Pliers: amzn.to/3tvB60w
Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
Milwaukee Tool Box: amzn.to/322iyK9
Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
Milwaukee Hook Blade Knife: amzn.to/33F3m5T
Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
Western Nitrogen Regulator: amzn.to/3rmdKrx
Klein Canvas Bucket: amzn.to/3FyzKVf
Flag Velcro Patch Kit: amzn.to/3K8Eswx
Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
Milwaukee Magnetic Light: amzn.to/3FulCfF
Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
SS2 Float Switch: amzn.to/3K7LJMW
3-Amp Breaker: amzn.to/3nxaSXJ
Appion Valve Core Removal Tool: amzn.to/33CFArw
Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
Similar Small Tubing Bender: amzn.to/3fJsziJ
Fluke Twist Guard Test Leads: amzn.to/3216R6j
Fluke 975 Air Meter: amzn.to/3GwD9oM
Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
Quick Check Acid Test: amzn.to/3GA2XAy
Wiha Torqe Screwdriver : amzn.to/3u1swH6
Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
Compressor Tote: amzn.to/3H8xHst
Inspection Mirror: amzn.to/3r9PERV
Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Опубликовано:

 

20 янв 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 141   
@kens.3729
@kens.3729 Год назад
Thank GOD for Repairmen like you that definitely know what they’re doing. 👍 Unfortunately there aren’t enough young people getting into a number of Trades.🙏
@jthonn
@jthonn Год назад
Man I agree, these young folks don't want to work (there are exceptions). They have a Ruud awakening coming.
@craigbraswell4269
@craigbraswell4269 Год назад
Yup, for every 5 hvac techs retiring, there are only 2 to replace them.
@tekjunkie28
@tekjunkie28 Год назад
@@craigbraswell4269 Good Maybe yalls pay will go up and then I'll join the trade.
@ThePeavey23
@ThePeavey23 Год назад
So glad I am done with that work almost 20 years in the industry doing this daily and I’m done !!! Thank you lord!!
@tomwalker9184
@tomwalker9184 Год назад
Well if you made 6 figure + income like Curtis doe's it much nicer. Than working for the man.
@kens.3729
@kens.3729 Год назад
Sweet looking White Van, Curtis. GOD knows you’re a Hard Worker and Don’t Stop until the Job is Completed and the Customer is Satisfied. Thanks! 👍🙏
@jdere31760
@jdere31760 Год назад
I hope you get prospective clients from them just watching your HVAC videos which show how much of a great diagnostician and hard worker you are! It's impressive...
@HVACGUY
@HVACGUY Год назад
I hope so too!
@itsallaboutASL
@itsallaboutASL Год назад
Congrats on the new van! Please make a video of your build out!!!
@stephenbullock1443
@stephenbullock1443 Год назад
Great work curtis
@douglaskahane141
@douglaskahane141 Год назад
N2 tank looks great..
@georgeramirez5225
@georgeramirez5225 Год назад
Good news finally a Van to work from makes it easier on jobs.Good job
@robalexander7348
@robalexander7348 Год назад
Nicely done Curtis, if only there were more dedicated tradesmen like yourself 👍 All the best with setting up your new van 👍
@kens.3729
@kens.3729 Год назад
That’s Not Snow in Georgia but instead it’s Ice in Curtis’ (HVAC GUY) World. 😬👍
@michaelhediger9088
@michaelhediger9088 Год назад
Nothing ever goes right. Good job
@throttlebottle5906
@throttlebottle5906 Год назад
the dryer vent into the garage is super lol. I guess it would heat the garage in cool weather(re-lol). I could see doing that with an electric dryer in colder climates and a drafty garage (if not the humidity would be bad and mold everything/structure) watching more, I bet the dryer used to vent underground through the green SDR pipe and elbow sticking up behind the condenser! It surely clogged with lint/leaking water in and breaking clothes dryers(blowing thermal fuses and other), so someone's hack fix was dumping it into the garage!
@earlestes8649
@earlestes8649 Год назад
The moisture would not be good
@jamessanchez4411
@jamessanchez4411 Год назад
I had to pull a 3\8 line from a basement to 2 story and attic on my on Bosch Change out from a train that was 1\4 it went better than I expected I think tape had dried out through years holding the lines together and I had a helper feeding the line from the basement .
@Sctronic209
@Sctronic209 Год назад
I would of and often do braze the line first then cut in the filter dryer. Great job on that one.
@thathvacguy
@thathvacguy Год назад
You are one hard working dude, reminds me of my father. I’m glad u got ya work van! shes beautiful. Bless God u and yours 💪🏽
@ervingoss5442
@ervingoss5442 Год назад
Nice looking van. I bet it will be even better when you get all of your supplies in it.
@fernandoprieto2865
@fernandoprieto2865 Год назад
Oh wow, what a great observation.
@LuisC202
@LuisC202 Год назад
God Bless man. Keep the great videos coming
@billsimpson604
@billsimpson604 Год назад
That white van will stay nice and cool. Guard your refrigerant supply. A few days ago I heard on the police scanner that thieves broke into somewhere and stole refrigerant! You would think they would have just run that copper line into the wall, instead of putting it under the slab. That is how mine was done. It goes into the brick, into the attic, and comes down into the hall closet evaporator coil and heat strip resistance money burner heater.
@billybrown1979
@billybrown1979 Год назад
like the video. good work. nice van. i see you find your knee pad. i see they got shark bite out for cooper tubing. is your GREE HVAC working good.be bless and safe.we are going to have a polar system coming down so get ready.
@Chris-ru3ri
@Chris-ru3ri Год назад
I always remove my gauges and core before brazing. Plus wrap the valve.
@michaelharris1653
@michaelharris1653 Год назад
I commented earlier about the temperature sensor. I should have added, when forcing defrost.
@officerkrupke4966
@officerkrupke4966 Год назад
He said in video that he changed out the defrost board and sensor.
@thesilentonevictor
@thesilentonevictor Год назад
Good video tech
@hinspect
@hinspect Год назад
Wow, that house was assembled by the lowest bidder it looks like! That dryer vent in the garage is unacceptable but not as bad as venting next to a condenser. That will be hard to modify. Great job on the heat pump repair, thanks for the Video!😉
@Guillotines_For_Globalists
@Guillotines_For_Globalists Год назад
Mice dryer exhaust in the garage. Top notch!
@ishalljr
@ishalljr Год назад
Nice pull! You had it right the first time thanks be to GOD, not luck!
@YukonHawk1
@YukonHawk1 Год назад
Really well done
@michaelmartin5582
@michaelmartin5582 Год назад
Excellent job Curtis. Would love to be out there working, but due to health issues had to retire. Really enjoy watching your videos.
@franciscotejeda1461
@franciscotejeda1461 Год назад
Like always doing an excellent job Mr Curtis and have a good day. 😃
@DanO181919
@DanO181919 Год назад
Did I miss something but how did you pump it down without any gauges hooked up.
@David-lf2ne
@David-lf2ne Год назад
His hand is calibrated for temperature and pressure. It’s the new upgrade along with new van.
@yellowdeer7163
@yellowdeer7163 Год назад
So glad to see you got a van.
@catwrangler1613
@catwrangler1613 Год назад
Love ur new ride!
@andrewschultz678
@andrewschultz678 Год назад
Epic job man very well done!
@MRXDS1989
@MRXDS1989 Год назад
That's love the condenser being 10 ft away.
@THESNAKE8
@THESNAKE8 Год назад
Heat probably didn’t kill the seal, i find those tend to leak just from being used after installation even if you’re not using a torch near them
@Chainsaw600
@Chainsaw600 Год назад
360, 361; whatever it takes. Couldn’t resist. Nice job!
@keepthinking2666
@keepthinking2666 Год назад
For the leak of the service on I don't know if you noticed it when you went to Valve it off for a pump down you could see a little poof of liquid freon spray out more than I could just a bad seal once you open the valve it should seal it and the same goes with the cap unless you price it in to replace it and the freon which is a lot more as you know
@keepthinking2666
@keepthinking2666 Год назад
I came across something similar last night at I guess I could call him a friend's house or more like an acquaintance where it was a quarter inch liquid line where somebody had replaced the unit about 20 years ago and instead of pulling the line said they left it the quarter inch and at the ends about a foot before the unit they changed it to 3/8
@HiddenResolve
@HiddenResolve Год назад
Curious why they went under the slab with it when it looks like the lineset could have just wrapped around behind that water treatment and HWT and out the sidewall.
@jthonn
@jthonn Год назад
That would have been too easy.
@richardambrose3156
@richardambrose3156 Год назад
looks like the way folks here do it... change an old R-22 system out and put in a R-410 and try to use Old Line Set...
@jthonn
@jthonn Год назад
Glad to see you are getting the van back, will be nice and easier to work out of. Do you think once up on a time they had a smaller unit that used a smaller line or was it just incorrect from the start? Reason I ask is my unit is old, so when I do the change out, I may need to run a new line set. It won't be easy on mine. I guess check and see what the new unit calls for and go from there. I just answered my own question. Nice job Curtis.
@gregmiracle9560
@gregmiracle9560 Год назад
Looks like refrigerant shot out of liquid line when you first started to close it off so I don't believe you caused the leak from heat I believe it was existing! But great job getting all run and done! 👍👍
@kens.3729
@kens.3729 Год назад
I suppose they used a Hose Clamp on the Old Copper line for Unknown reasons. 🤔
@qyouwilber5734
@qyouwilber5734 Год назад
I have soldered electronic components in the past and if you did not want to over heat them you would use an alligator clip as a heat sink. You could have put the valve cap back on or get a large fitting with the same threads as the cap and put that on the valve to draw the heat away. Heat travels just like electricity and the bigger the wire the more current/heat it will carry away. I don't know if that would make a big difference with a torch in such a small distance but it couldn't hurt.
@cal3178
@cal3178 Год назад
I worked in electronics repair years ago. Now own a hvac company. I use my soldering skills to repair many control boards that develop cracked solder joints. Its very common on certain brands molex plugs. A soldering iron gets to around 700 degrees max. Oxyacetylene brazing can get between 6000 and 7000 degrees.
@qyouwilber5734
@qyouwilber5734 Год назад
@@cal3178 copper melts at 1900 degrees. If you are brazing at 6000 degrees it probably won't work. I looked up brazing temps and they say 850 to 1400 degrees. You can also solder the connections like a plumber would if the code allows. He might be able to use a large spring clamp with the rubber removed to help draw the heat from the valve.
@topher8634
@topher8634 Год назад
All that ice on the coil sure helped with the pump down no doubt. 410 systems usually buck and open the IPR.
@chrissipple1018
@chrissipple1018 Год назад
Just a note when ever you are pumping down a system always install gauges so you know what pressures you have. And never pump any kind of a compressor into a vacuum. With out gauges you never know if its in a positive or in a vacuum. Im sure that I'm wrong. Just do it the right way.
@David-lf2ne
@David-lf2ne Год назад
I noticed that too. I guess his hand is calibrated for temperature and pressure.
@chrissipple1018
@chrissipple1018 Год назад
@@David-lf2ne This guy is fun to watch
@c21meister
@c21meister Год назад
Wooowww congrats with the new van! Can you sell me your old one?
@Eddy63
@Eddy63 Год назад
Watch Steve Lav's vids on restocking his new truck ... He's a one man wreckin' crew ... Good vid , thx for sharing ...
@Ridehighfxdb
@Ridehighfxdb Год назад
Why wouldn’t you clean the bubbles and cool gel out the valve before you put the cap on with leak lock?
@bryanharayda1975
@bryanharayda1975 Год назад
Did anyone else notice the double trap in the drain line? Trap under stand and second trap when drain goes under slab and back up outside. Also I may have missed something but how were you able to pump that unit down into the condenser in heat mode? I see it now, it was a Rheem/Ruud, reversing valve is energized in heating, and you pulled the O wire off the defrost board. This is why I shouldn’t watch these videos at 3 am lol
@dalescott838
@dalescott838 9 месяцев назад
When you sucked down the system you should have your gages connected. That way you can see what you are doing.
@throttlebottle5906
@throttlebottle5906 Год назад
35:48 failed leaking o-ring, go figure! they either leak with age or once you touch them(turn to close/service) pretty much they're useless except for being new shipping from factory with pre-charge.
@jamesfitzsimmons381
@jamesfitzsimmons381 Год назад
I was betting the old line was ok even at 5/16
@cal3178
@cal3178 Год назад
That’s what I’m thinking. How old was that system? It’s worked for that long
@bobgallo3775
@bobgallo3775 Год назад
Not all repairs go nice and smooth
@jamesfitzsimmons381
@jamesfitzsimmons381 Год назад
I think I would have run the new line exposed
@Bass.Player
@Bass.Player Год назад
I always wondered why those access caps don't have some sort of seal in them.
@matthewclemons1574
@matthewclemons1574 Год назад
Its supposed to cut into the valve seat.
@craigbraswell4269
@craigbraswell4269 Год назад
Sometimes they have a rubber gasket in them, I've seen gaskets on certain goodman/Amana outdoor units.
@michaelharris1653
@michaelharris1653 Год назад
Should you not jump the temperature sensor?
@chuckquinn8026
@chuckquinn8026 Год назад
Gotta say 99% of techs, especially working alone, would have just drilled thru the wall vs pulling under the slab 🤷‍♂️ Congrats on the new van. Did the insurance company total your van?
@HVACGUY
@HVACGUY Год назад
No, but they are paying for repairs.
@Hvac-dude
@Hvac-dude Год назад
Hey Curtis this is a very odd question I should already know but how exactly do u pump down a condensor unit well ac
@d3adp94
@d3adp94 Год назад
Service valves on condenser. Front or back seat them to open/close
@jrtakesthesky27
@jrtakesthesky27 Год назад
Close your high side service valve by front seating it and keep your low side open. Run the system in cooling (aka just press the contactor down). You usually want to monitor the low side pressure but in this video's case the condenser is frozen so there is low to no risk of over heating the compressor windings. You wait for the Low side to get just under 0 psig, you want to lose as little refrigerant as possible. Remember the compressor needs refrigerant to cool it down so don't run it forever in this vacuumed state. Then you can close the low side service valve and you now have a condenser pump down.
@Hvac-dude
@Hvac-dude Год назад
@@jrtakesthesky27 thanku !!
@mikerodriguez1455
@mikerodriguez1455 Год назад
What’s the charge for the replacement of the 1/4 “ liquid line , I’m very interested in how much you charge for such a difficult job!!! 😱
@97Napkins
@97Napkins Год назад
I prob woulda gave up after not pulling and just ran it through the wall and to the unit
@bobrumpf2576
@bobrumpf2576 Год назад
great job on that one ,do you ream that pipe after you cut it?
@jimharmon3404
@jimharmon3404 Год назад
Great job Curtis. I don't know hardly diddly about HVAC. Finally I just have to ask... what's in that dryer you always replace? Can you open a "pre-enjoyed" old one so we can see whats inside? How do you know when they need replacement?
@chrisischill2693
@chrisischill2693 Год назад
Anytime system is opened.
@HVACGUY
@HVACGUY Год назад
Desiccant beads, or block, and fibrous filters on the ends
@officerkrupke4966
@officerkrupke4966 Год назад
@@HVACGUY Had a new install and techs didnt install filter drier. I called owner of company and he came out and said it was factory installed and pointed at the compressor muffler. Choose your hvac company carefully, and the cheapest price isnt always your best option.
@viper22304
@viper22304 Год назад
Thanks for sharing the video. Great work. Question: did you backseat the liquid line before or after the adding the seal lock? thanks again
@bamatractor
@bamatractor Год назад
I can tell you feel like crap today!
@patricspointofview7188
@patricspointofview7188 Год назад
When you change the liquid line, you don't need to evacuate the whole system? Where does the freon go?
@HVACGUY
@HVACGUY Год назад
Pumped into condenser
@karellodewijks4971
@karellodewijks4971 Год назад
👍👍😊😊
@benaskew1301
@benaskew1301 Год назад
I love watching your videos but it kills me when you don't ream those cuts.
@billyk5107
@billyk5107 Год назад
I wouldn’t of cut out the liquid line dryer I would’ve un sweated it so that you could use the fitting again on the service valve
@EverythingHVACR
@EverythingHVACR Год назад
I didn't see the previous video. An undersized liquid line was causing high pressure?
@HVACGUY
@HVACGUY Год назад
Yes
@jthonn
@jthonn Год назад
Yes
@jamesfitzsimmons381
@jamesfitzsimmons381 Год назад
In first video the pressure was fine in cool mode but high in heat mode. I would think the pressure would be high in both modes if the liquid line itself was too small
@EverythingHVACR
@EverythingHVACR Год назад
@James FITZSIMMONS Well, I thought about this, and restrictions or small liquid lines won't usually cause high pressure, that's why I asked. But your condenser coil gets smaller in heat mode, so it could affect you more so than in cooling mode.
@jamesfitzsimmons381
@jamesfitzsimmons381 Год назад
@@EverythingHVACR that’s one reason some of the early Rheem/ Rudd had charge adjusters in the indoor coils to kinda equal out the charge between heat an cool
@NoorRefrigerationsystem
@NoorRefrigerationsystem Год назад
Hello sir .. How are You
@FG-tg9uk
@FG-tg9uk Год назад
If anyone can turn Chicken Poop into Chicken Soup, it's you. Well done.
@keepthinking2666
@keepthinking2666 Год назад
But quick question did you tell him to cut the bushes around that unit to give it more air flow as well and did you test the defrost switch thermostat
@Brand14BJ
@Brand14BJ Год назад
I believe he replaced it.
@purtis99
@purtis99 Год назад
Oscillating saw
@gordonpotts753
@gordonpotts753 7 месяцев назад
Jesus was on ur side on this one
@billyk5107
@billyk5107 Год назад
I wouldn’t pull it out I would blow through it and see if it’s got a restriction with nitrogen if it goes through it super easy leave it
@matthewclemons1574
@matthewclemons1574 Год назад
As a reefer tech leak lock is garbage, best bet honestly is monster tape(very little) and nylog. Or just nylog and tighten it down.
@richardvisco6370
@richardvisco6370 5 дней назад
Ohm out defrost sensor see if its closed while ice is on coil
@richardvisco6370
@richardvisco6370 5 дней назад
Hope it's a biflow drier
@channelcatchaser9426
@channelcatchaser9426 Год назад
No guage on the pull back? Probably more the drier than line size...but probably line size is important as well. Good job
@jima3129
@jima3129 11 месяцев назад
Hole saw and s length of 1 inch pvc?
@TomLawson05
@TomLawson05 Год назад
This unit has suction line drier could it be stopped up?
@HVACGUY
@HVACGUY Год назад
I think that’s called a charge compensator. That’s not a suction filter - it’s not on true suction.m
@MrDookieDan
@MrDookieDan Год назад
where was the knee pad?
@HVACGUY
@HVACGUY Год назад
This call may be where I left it
@jamesfitzsimmons381
@jamesfitzsimmons381 Год назад
Curtis just curious did you check the drier like blowing your mouth through it just to see if it was restricted I know you didn’t have any frost on it but maybe your subcooling was too high at that time to show frost etc
@HVACGUY
@HVACGUY Год назад
No, i didnt
@jamesfitzsimmons381
@jamesfitzsimmons381 Год назад
@@HVACGUY thanks Curtis for getting back to me
@elijahgoodman3140
@elijahgoodman3140 Год назад
Just curious, what did your head pressure settle out at? By the way, excellent troubleshooting!
@HVACGUY
@HVACGUY Год назад
Around 310 when I left
@earlestes8649
@earlestes8649 Год назад
@@HVACGUY what is it supposed to be? Ty
@EvesterGaming
@EvesterGaming Год назад
@@earlestes8649 All depends on outdoor and indoor temp for pressures
@earlestes8649
@earlestes8649 Год назад
@@EvesterGaming I repair appliances and furnaces and AC except for Freon anything electrical or plumbing. I’m handicapped but I wanted to take classes for it but they told me that with my history they wouldn’t pay for anything but a office job. So I took accounting and passed with b average . But couldn’t see me behind a desk, I love wiring houses and putting in meter bases etc, I’ve fixed my AC and furnace several times over the last 30 years it was installed in 92
@mattbilodeau2433
@mattbilodeau2433 Год назад
I got scared for you when it wouldn't pull outside. Do you ever use wet wrag paste for valves?
@richardvisco6370
@richardvisco6370 5 дней назад
Bad defrost sensor
@jamesfitzsimmons381
@jamesfitzsimmons381 Год назад
Common liquid line restrictions include clogged filter-driers or metering device restrictions. Many techs think that refrigerant will exit the compressor and back up against the source of the restriction, which would raise the head pressure. However, that’s not true. Our diagnostic sheet shows that liquid line restrictions cause low suction pressure and normal to low head pressure, not high head pressure. That’s because the compressor requires refrigerant of a specific density to pump refrigerant into the high side of the system; when the suction pressure is low, the compressor can’t move as much pressurized refrigerant to the high side, so a liquid line restriction doesn’t have a huge impact on the head pressure when you have reduced amounts of high-pressure refrigerant in the liquid line in the first place. Some thought experiments that can help you grapple with that idea include thinking about refrigerant in a tank and the pump down cycle (used to prevent refrigerant migration). Note: don’t pump down a microchannel condenser! However, when you have a restriction, its location has a significant effect on the head pressure. The amount of charge also matters, as overcharged systems are more likely to have a significant impact on the head pressure (raising it and causing hydrostatic pressure buildup within the system). The most common liquid line restrictions are clogged filter-driers, metering device inlet screens, a kinked liquid line, or a TXV with an empty bulb. These very rarely cause high head for more than a short period of time. The most common causes of high head pressure include high load, overcharge, and poor heat rejection (such as from dirty or obstructed condensers). One response to “Do Line
@davidgearardo1788
@davidgearardo1788 Год назад
damn you braze fast , god my weak point is brazing, been working on it but damn all the pro press guys need take note, brazing can be faster
@Mapdotgolf
@Mapdotgolf Год назад
Bad sensor for defrost
@gregwalker731
@gregwalker731 4 месяца назад
Worked in the business for a lot of years. This is one of the things that aggravated me the worst, poor installation. This unit never had a proper installation or start up done. The customer now has to pay someone to fix the installation that they have already paid for once. My second pet peeve is installation without considering serviceability.
@adrianfelix1592
@adrianfelix1592 Год назад
Is this your own business?
@robertwood9628
@robertwood9628 Год назад
I know you have many young followers that think everything you do is great and I truly hate to be a downer but...OK I'm not going to list the things I would correct after all. Just shaking my head.
@rugged1987
@rugged1987 Год назад
How can I even take you serious if you cant even use a pair of channel locks the correct way 🤔
@andrewszaniszlo9243
@andrewszaniszlo9243 Год назад
I was telling my hvac class that you are a very smart mechanic, but you do not protect your health, and over time it will kill you.please wear a mask when in dangerous atmospheres and don't breath in refrigerant.
@timrob0420
@timrob0420 Год назад
Did you look in manual? Some of those older rheems took 1/4in liquid line….
Далее
Gli occhiali da sole non mi hanno coperto! 😎
00:13
HVAC Is The Compressor Bad?
9:33
Просмотров 1,6 тыс.
AC Pressures, Subcooling and Superheat
29:52
Просмотров 255 тыс.
Goodman Condenser Pumping Down with a Piston
48:03
Просмотров 34 тыс.
Working On An Antique Going Out On Thermal
39:10
Просмотров 16 тыс.
Gli occhiali da sole non mi hanno coperto! 😎
00:13