School emergency diesel generator and automatic transfer switch test with real power failure test 

NIC’S - SYSTEMS & ELECTRIC
Подписаться 30 тыс.
Просмотров 9 тыс.
50% 1

Опубликовано:

 

28 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 48   
@spykillergames8402
@spykillergames8402 Год назад
wow...a 4 cyl perkins...made in the UK..funny to see it all the way over in canada esp mated to a generator head....over here they were a go-to for small minibuses and tractors
@RDC_Autosports
@RDC_Autosports Год назад
caterpillar bought em
@boostaddict_
@boostaddict_ 11 месяцев назад
they were common over here for tractors from the 50s to the 70s too
@billyfowler9423
@billyfowler9423 8 месяцев назад
That generator will last for many more years, runs smoothly, could probably power a lot more of the building with it.
@jimmyssnowremoval1075
@jimmyssnowremoval1075 11 месяцев назад
The place where I do facility maintenance at with 5 other engineers, we have 6 generators. The oldest one have is diesel the rest are natural gas and I asked when I first started is if there’s a disaster they’ll probably turn off the natural gas but on grounds we have a 200 gallon diesel tank to fill equipment wouldn’t it be better to run off diesel.
@hqgirl567
@hqgirl567 Год назад
The way the generator came on, it sounded like a truck turning on. But nice video
@GaryBeltz
@GaryBeltz 9 месяцев назад
Why does that school have two Fire Alarm panels? I see a Simplex at the beginning of the video then when you turn the power off I can see the EST fireshield.
@nics-systems-electric
@nics-systems-electric 9 месяцев назад
There's three panels in total the simplex 4100 Plus is the main panel and the EST fire shield is the theatre panel that opens the roof and there is another panel in the commercial kitchen for the suppression system
@henrydoesstuff213
@henrydoesstuff213 3 месяца назад
3:01 startup (sounds like a propane bus)
@BC_OPERATOR
@BC_OPERATOR День назад
International icce
@marksmith-ew7ir
@marksmith-ew7ir Год назад
I think the same engine is in narrow board here in the uk.
@petra7306
@petra7306 3 месяца назад
I love you nic
@bradwilmot5066
@bradwilmot5066 Год назад
The ammeter on the transfer switch is definitely pooched, as it didn't even twitch when it transferred over. The one on the genset itself is also likely bad... I imagine the transformers alone account for 10 amps or so, so sitting at essentially zero is bollocks.
@nics-systems-electric
@nics-systems-electric Год назад
Yep it's definitely done
@GaryBeltz
@GaryBeltz Год назад
What does pooched mean?
@nics-systems-electric
@nics-systems-electric Год назад
@@GaryBeltz no good, dead, fucked, broken, done, defective etc.
@thestihladdict1743
@thestihladdict1743 Год назад
Looks like it transfered power before if even got up to operating speed(60hz) . Definitely weird 😆
@nics-systems-electric
@nics-systems-electric Год назад
Yeah it was pretty fast if it wasn't below 60 it had barely just got there this one doesn't wait around to make sure things are stable it just throws load at it lol
@thestihladdict1743
@thestihladdict1743 11 месяцев назад
@@nics-systems-electric yeah. It just wants to comply with nfpa110 😂😂😂😂😂😂😂😂
@nics-systems-electric
@nics-systems-electric 11 месяцев назад
@@thestihladdict1743 yeah which it doesn't even need to as it's a school lol
@ebelray6890
@ebelray6890 Год назад
I need one of these
@leafmk
@leafmk Год назад
Huh Interesting stuff.
@ТоваришБандар-п2т
@ТоваришБандар-п2т 7 месяцев назад
فاااااااك بيب 😂😂😂😂ههههههههااي 🎉❤🎉❤
@peterryan7340
@peterryan7340 11 месяцев назад
I am a hospital engineer in Australia. The generators we use take between 10 and 20 seconds to start for a black start (zero grid connection). 305kw turbo diesel Yanmar.
@nics-systems-electric
@nics-systems-electric 11 месяцев назад
That's not bad at our local hospital here we have 4 caterpillar diesels 1500 KW each which the original contractor hired had them starting within around 12 to 18 seconds but the hospital complained it was too slow and had the generator company we deal with at the school district come in and make some changes and has them all starting and synchronized within eight seconds which is pretty impressive only three of the generators are needed to run the building so after a period of time the fourth will shut down
@peterryan7340
@peterryan7340 11 месяцев назад
@@nics-systems-electric so no load shedding with that much power on tap?
@nics-systems-electric
@nics-systems-electric 11 месяцев назад
@@peterryan7340 not exactly sure how much they are running there but assume pretty much everything with that large of a emergency supply the UPS's I'm sure only do critical loads to cover the start up time but I would have to assume other loads are likely almost all on generator power I haven't had a detailed walk-through on their system though so I couldn't tell you exactly just from what I've seen and heard
@peterryan7340
@peterryan7340 11 месяцев назад
@nics-systems-electric we load shed our chiller units, have 80kwh storage for UPS until generator supply initiates. The only AC we have during grid failure is Operating Theatres and Communications Rooms. Our total load is actually very low as energy efficiency is critical nowadays
@nics-systems-electric
@nics-systems-electric 11 месяцев назад
@@peterryan7340 that's interesting I'm assuming we keep our HVAC system running as well as elevators which are another huge load and all lighting that leaves me wondering what actually isn't kept going not sure if the generators there are 1500 KW at 600 V or at 208 V but either way it's a large supply it is pretty impressive that they have them starting in around eight seconds now I'm not sure why the hospital complained that the 12 to 18 seconds before was too slow as the UPS's should be more than capable of covering that time other than you may lose your general lighting for a short period of time
@AtticusMinecraft123
@AtticusMinecraft123 11 месяцев назад
The power generator looks like hooting the car engine
@GaryBeltz
@GaryBeltz Год назад
That generator looks like it will need to be fueled soon that fuel gauge looked like it was at half or maybe a little over.
@nics-systems-electric
@nics-systems-electric Год назад
If the gauges is true I wasn't paying attention I didn't see one who knows if it's accurate
@petra7306
@petra7306 3 месяца назад
Why is the generator so rusty
@BeezyKing99
@BeezyKing99 Год назад
you weren't sure about the year of that generator, it's right on the tag you were looking at @10:16 May 1996, is when it was built.
@nics-systems-electric
@nics-systems-electric Год назад
Yep I saw that afterwards
@Granth_Man
@Granth_Man Год назад
Loves the 60hz sound at the beginning by the way the video is school
@joaquinfernandesgarcia996
@joaquinfernandesgarcia996 11 месяцев назад
7:55 The generator has now entered its cool-down period
@jcc3279
@jcc3279 11 месяцев назад
Nic, what model is that simplex panel in the backround. i heard it's trouble alarm go nuts during the transfer to emergency power. is it still being used or is it getting replaced with a new system sometime. just curious and greetings from Orlando, Florida.
@nics-systems-electric
@nics-systems-electric 11 месяцев назад
4100 plus. no replacement planned yet
@jcc3279
@jcc3279 11 месяцев назад
@@nics-systems-electric Thanks nic, also about your generator situation at home. I also don't have natrual gas service where i live in Florida but i do have a whole house generator but mine runs on a big propane tank in the backyard. just a thought for you at home dude. Came in handy when Hurricane Ian and Nicole hit my area. Power went out and less then 2 minutes max i was back online. My whole house gen is a 20kw kohler. Runs everything including my well, pool pumps etc.
@nics-systems-electric
@nics-systems-electric 11 месяцев назад
@@jcc3279 yes that is an option if you have propane however due to the cost and limitations on how it's allowed to be stored gasoline was my only option
@jcc3279
@jcc3279 11 месяцев назад
@@nics-systems-electric oh i understand but you could have a tank put in depending on costs but i know about how it's stored etc. we had our tank put in when we bought this place. wasn't cheap but it was so worth it.
@luiscoelho4151
@luiscoelho4151 10 месяцев назад
A ceiling light made by holophane 2 on and one off
@jeremiahhively3025
@jeremiahhively3025 11 месяцев назад
Love these videos
@UKsystems
@UKsystems Год назад
Do the generators also get serviced?
@nics-systems-electric
@nics-systems-electric Год назад
Yes every year at the 2 hour load bank test
Далее
Generator load bank testing at my high school
15:55
Просмотров 8 тыс.
Brilliant Budget-Friendly Tips for Car Painting!
00:28
Kenji's Sushi Shop Showdown - Brawl Stars Animation
01:55
Diesel Engine Rotting in the Woods, WILL IT START?
32:17
Why smaller generators are better for power outages.
12:55
How 3 Phase Power works: why 3 phases?
14:41
Просмотров 1,1 млн
Fife hospital hv room blackstart
3:01
Просмотров 34 тыс.
USS SLATER...Start Your Engine
13:05
Просмотров 573 тыс.