In this lesson we'll examine hard wired relay based ladder logic and programmable logic controller or PLC based implementations of single step and staged secondary resistor reduced voltage starters used to reduce inrush current demand for wound rotor induction motors. (Part 2 of 2)
___________________
If you wish to support this project please visit the Patreon page at: / bigbadtech
___________________
Copyright information: Use this lecture. Use it at home, at work, or at school. Put it in a playlist, embed it in a website, share it with your coworkers, family, friends, and enemies. I made this lecture and posted it on RU-vid so users everywhere have free access to this information.
This being said, this RU-vid channel is meant to be the sole point of distribution for this lecture. Users are not authorized to download it, change it, or charge for access. Don’t even think of downloading it and uploading to your own channel and pretending it’s your own work. Not cool. Use this lecture and let your friends know this free resource exists.
Use it. Don't steal it. Be cool.
__________________
For more FREE online technical training check out the following playlists available at the bigbadtech channel:
DC Circuit Analysis • DC Circuit Analysis
Single Phase AC Circuit Analysis • Single Phase AC Circui...
3 Phase AC Circuit Analysis • 3 Phase AC Circuit Ana...
Hydraulics • Hydraulics and Electri...
Pneumatics • Pneumatics
Motor Control • Motor Control
Motors and Generators • Motors and Generators
Motor Drives/Variable Frequency Drives (VFD) • Motor Drives
Programmable Logic Controllers (PLCs) • Programmable Logic Con...

Опубликовано:

 

5 мар 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 5   
@marvintomol181
@marvintomol181 5 месяцев назад
nobody discover this solid channel...Its like my favorite food that i dont want to share...your motor configuration give me confident a lot in my work,no more worries everytime i change motor connection...
@cascadeanalog320
@cascadeanalog320 4 месяца назад
Once again, Thank you Jim !
@axenevermore
@axenevermore 28 дней назад
Thank you for enlightening me😊
@rowlandcrew
@rowlandcrew 5 месяцев назад
Hi J, it seems that invoking a programmable plc still requires buying a bunch of resistors that need to be wired in, regardless of hardwire contactors or programmable plc. Why not use 3 PTC's (or a resetable thermal fuse) and skip the PLC? it appears that there are X and y class PTC's. How much does it cost, did you pay, to buy the electrical and hydraulic famic software? It would be entertaining and educational to see you work through adjusting the excitation on the field (with mechanical rotor input) for the purpose of adjusting a generator output.
@bigbadtech
@bigbadtech 5 месяцев назад
Oh yes there are many more ways to skin this cat besides regular resistors ... ever heard of a liquid starter? Basically it's an electrolytic solution and as a contact is pulled in an out of it it changes resistance. As you mentioned cost is the primary concern for any application!