Тёмный

Servicing Worcester System Boiler 

Hancock and Brown
Подписаться 2,4 тыс.
Просмотров 19 тыс.
50% 1

This video is to help new installers and apprentice’s. It’s our findings that the modern colleges sometimes have their hands tied by modern curriculum, leaving gaps in real life gas work. Hopefully youtube can help bridge gaps.. this is a bit long winded but should help you know what you’re up against.

Хобби

Опубликовано:

 

30 мар 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 47   
@charliefox6987
@charliefox6987 6 месяцев назад
Great video thanks for posting , learning a lot
@ChrisJoned
@ChrisJoned 3 дня назад
Is this what a decent gas engineer looks like 5 star service
@Carl-re6zb
@Carl-re6zb Год назад
Great upload.. Was thinking you made changing the bearing plate washer harder than it is. I Normally just unlock the connection to the fan and check and replace the washer if needed, but kudos to you as you also changed the fan seal and 'mixing tube' 'banana' washer also. Like anything the more your familiar with something, the easier it is, so I actually do these regularly, and find it straightforward . Thanks for your channel
@GHancock
@GHancock Год назад
Always room for different methods, think it’s imported to just to past info to the next generations… thanks for watching
@j.j8114
@j.j8114 7 месяцев назад
the bearing plate housing just twists off mate...
@monikanader9454
@monikanader9454 Год назад
Great video, thanks👍
@jellyboy123
@jellyboy123 Год назад
the guy who comes to my house to do my boiler is in and out in 10 minutes i be telling him next time he’s over.
@GHancock
@GHancock Год назад
Once the boilers are over 5 years old, it wants to book in for an overhaul like this. Don't wait for the gasket to go and melt everything or the baffle to stick. But he will need prior notice to allow more time.👍
@Cvbbj670
@Cvbbj670 Год назад
Proper pro mate Good run down how to do a service right
@Razz60
@Razz60 2 года назад
Brilliant video thanks
@GHancock
@GHancock 2 года назад
No worries, I know it’s long ..🙂cheers for watching
@waynehardiman5443
@waynehardiman5443 9 месяцев назад
What’s a service like this costing in todays market
@markprentice522
@markprentice522 6 месяцев назад
great video and would agree with all the other comments. however, be honest, how long did that take?
@GHancock
@GHancock 6 месяцев назад
Allow yourself a 3hr time slot just incase, you can strip them down in half hour when things go smoothly.. but sometimes everything bonded in so tightly
@45graham45
@45graham45 Год назад
How does the cost compare with servicing the heat exchanger & replacing it with a new heat exchanger?
@GHancock
@GHancock Год назад
Labour would be similar, big difference is the price of the cell, so about £500 more I guess.. but sometimes the baffles come straight out so the jobs a lot easily.
@esuohdica
@esuohdica 5 месяцев назад
Very useful! Do you rate these boilers over Baxi heat only?
@GHancock
@GHancock 5 месяцев назад
I do, but the Baxi is a great boiler and a solution for an application where a pump overrun is not possible
@mickclarke5741
@mickclarke5741 Год назад
You can get the baffle extraction tool from any woseley
@GHancock
@GHancock Год назад
I know they do the normal tool, but I’ve not seen them doing the puller..mines made by Dr pipe.. which you can buy from the Dr pipe website … free plug there 🙂
@djhvideo
@djhvideo Год назад
Wasn't there a memo from Bosch telling service engineers to replace the top seal every year as they fail around the electrodes. (Admitting there is a design fault?)
@GHancock
@GHancock Год назад
Every 5 years, not really a fault in design. They still have the same design now.. Just people are leaving them until they fail the depression reading and this was to long for the gasket lifespan
@Martindyna
@Martindyna Год назад
@@GHancock I'm in a bit of a dilemma, my 12Ri has never been serviced properly because it has always passed the flueway pressure drop test and it's now 18 years old. I thought they were wrong to never brush out the heat exchanger. It had a new fan assembley fairly recently so the red gasket would have been replaced but I'm worried that the baffles will be stuck in there. I wish you covered the South, you do a proper job.
@GHancock
@GHancock Год назад
@@Martindyna chances are this baffle will be stuck solid..you need a independent installer who doesn’t have to get around 8 jobs a day.. someone who likes the challenge of getting them out. Buy yourself a pot of Bicarbonate ready to lend them.. failing this start saving for a new boiler with 10 year guarantee. Sorry I don’t travel very far as I never have the need to..most my jobs are in a 5 mile radius 🙂
@Martindyna
@Martindyna Год назад
@@GHancock Thanks for your response & advice.
@Maciejowicz
@Maciejowicz 10 месяцев назад
0:08 soscket and plug for extra protection LOL
@charliewillis8527
@charliewillis8527 5 месяцев назад
We all like todo things roperly but when you tell them what a full strip down costs they go else were. On a cd you have a £100 on parts so its a £200 job
@GHancock
@GHancock 5 месяцев назад
You’d only have to do this every 5 years…so it’s not to bad to sell..beats them having a new heat exchanger
@charliewillis8527
@charliewillis8527 5 месяцев назад
@@GHancock yes that is correct I normally do it every 4 years
@k20aa
@k20aa 2 года назад
I dont care what anyone says they a horrible to work on
@mickclarke5741
@mickclarke5741 Год назад
The worst.
@glenmilner9828
@glenmilner9828 5 месяцев назад
They look like a right pain in the arse.
@glenmilner9828
@glenmilner9828 5 месяцев назад
Been asked to service one of these in a loft space. Thinking about jogging it on after watching this
@forsyth2842
@forsyth2842 4 месяца назад
just had ovo service boiler all he did WAS A FGA AND LEFT
@GHancock
@GHancock 4 месяца назад
Should clean the trap, and set co2 minimum.. but every 5 years make sure you get a full strip down.. but expect to pay more. If it’s left to long the baffle will not come out or burner gasket will fail.
@mgbroadsterJ
@mgbroadsterJ Год назад
They are a lovely boiler to fit , servicing these boilers nearly gives me a reak down .What a terrible design . Worcester should of designed a smaller version of the CDI .
@GHancock
@GHancock Год назад
I do like the cdi better...mind you these boilers seem to keep on going once cleaned out
@mgbroadsterJ
@mgbroadsterJ Год назад
@@GHancock I think a day at Worcester training would give me more confidence . Ha e you fitted the 800 with diverter ,to change it to priority hot water ? The instructions blow my mind .
@GHancock
@GHancock Год назад
@@mgbroadsterJ get yourself down there the courses are good.. I’m there next week. I don’t install anymore the lads have that covered
@matthewbullock3035
@matthewbullock3035 2 года назад
Great thorough job 👏 but what an awful design like most worcesters
@GHancock
@GHancock 2 года назад
You get used to them.. glad you like it.
@rognevs5695
@rognevs5695 Год назад
Bet you didn’t cut your hands 😂
@johncummins3860
@johncummins3860 7 месяцев назад
Aways cut mine getting the electrode leads off - the new model is even worse !!!
@milkman100001
@milkman100001 6 месяцев назад
one of the worst designed heat exchangers ever. will never beat the baxi boilers.2.5 mins and your into the chamber.these boilers are difficult, take ages and are maid of ali. salts up all the time. ive no idea why people thing these are the best boilers.
@GHancock
@GHancock 6 месяцев назад
Mainly the CDI and He that built there reputation, but I have a lot of these ticking over at 16plus years without to much trouble, plus Worcester was the first to make a down loading burner whilst all the others messed around with condensing exchanger added to up existing design, I like Baxi too..but I can pick fault with every manufacturer.. so after service becomes the key as well as good manufacturing. Every Engineer has to push the product he believes in.
@ChrisJoned
@ChrisJoned 3 дня назад
British Gas and homeserve do minimal in and out in 10 minutes and the worst thing they charge £110
@GHancock
@GHancock 3 дня назад
I think there is a lot of pressure on there workers to get around a lot of jobs. Thanks for the feedback 👍🏻
Далее
Worcester Greenstar Return manifold
28:16
Просмотров 10 тыс.
ПОДВОДНЫЙ ГЕЙМИНГ #shorts
00:22
Просмотров 658 тыс.
Retirando rejunte antigo
10:05
Просмотров 2
Worcester Bosch CDi Compact ERP Full Service
19:01
Просмотров 17 тыс.
Servicing, fault finding Worcester Bosch
32:16
Просмотров 11 тыс.
Regulation 26.9 Gas Engineer Safety Checks | NGCFE
17:04
I Wouldn't Do This For A Customer.....
36:36
Просмотров 29 тыс.
Worcester Bosch CDI full service
6:59
Просмотров 36 тыс.
АРТ-ОБЪЕКТ СО СМЫСЛОМ
0:23
Просмотров 9 млн
РЫБАЛКА ДОМА
0:17
Просмотров 2,9 млн
I lost my kitten on the street😭 #cat #cats
0:32
Просмотров 157 млн