Тёмный

Shallow Foundation: Numerical on Calculation of Safe Bearing Capacity and Permissible Load 

Curious Civil Engineer
Подписаться 7 тыс.
Просмотров 74 тыс.
50% 1

This video discribe the procedure of calculation of Safe Bearing Capacity of Shallow foundation and Permissible Load that can be carried by a footing. We have used Terzaghi's Method for calculating safe bearing Capacity
Terzaghi’s method is, in fact, an extension and improved modification of Pandtl’s (Terzaghi,1943). Terzaghi considered the base of the footing to be rough, which is nearer facts, and that it is located at a depth Df below the ground surface (Df ≤ b, where b is the width of the footing).

Опубликовано:

 

29 мар 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 31   
@rahmanrahmani2896
@rahmanrahmani2896 4 года назад
Normally the BCS (Bearing Capacity of Soil) is determined by soil investigation on site through boreholes. This value has to be divide FOS = 2 or 2.5 ! Thank You!
@nidheeshkp9881
@nidheeshkp9881 2 года назад
Please can you tell me how can we calculate bearing capacity using N values (SPT)
@sambhavtakkamore6081
@sambhavtakkamore6081 3 года назад
What is the ultimate bearing capacity of a circular footing of 1 m diameter resting on the surface of a saturated clay of unconfined compression strength of 100 kN/m2? What is the safe value if the factor of safety is 3?
@rohitmeena6368
@rohitmeena6368 3 года назад
sir please tell how calculate depth correction factor asper IS 8009 for SBC asper SPT
@ayazsiddiqui3263
@ayazsiddiqui3263 3 года назад
Thanks sir...!! 🙏
@MDHasan-no9vd
@MDHasan-no9vd Год назад
Sir how to calculate Ng?
@wruwan
@wruwan 3 года назад
Thanks
@CuriousCivilEngineer
@CuriousCivilEngineer 3 года назад
Your welcome Ruwan
@milankarkee
@milankarkee 3 года назад
confused how to calculate Area of footing
@ceo31122
@ceo31122 Год назад
Excuse me Sir Here this is Local Shear Failure Phi < 26 ° so we have to assume it local shear failure For that Cm = 2/3 × C is to be considered but u have taken here directly C how can it be possible ?? Please reply sir 🙏🙏
@CuriousCivilEngineer
@CuriousCivilEngineer Год назад
It was not mentioned in the statement but ur right
@048-ritikkumar9
@048-ritikkumar9 Год назад
haan ye wrong hai
@chandrashekar5933
@chandrashekar5933 2 года назад
Sir can upload pdf
@alial-araji222
@alial-araji222 3 года назад
Why are you adding gamma x Df and calculating qsafe? Why can’t you just use qns? Thanks
@CuriousCivilEngineer
@CuriousCivilEngineer 3 года назад
Because in the numerical it was asked to determine q safe not the net safe bearing capacity.
@alial-araji222
@alial-araji222 3 года назад
Thank you!
@shubhamnikumbh6948
@shubhamnikumbh6948 3 года назад
Shubham Bhalchandra Nikumbh B-12
@TRAVELAIRDROP
@TRAVELAIRDROP Год назад
very tanckfull
@nasirmanzoor3425
@nasirmanzoor3425 2 года назад
how to calculate ultimate and allowable load
@CuriousCivilEngineer
@CuriousCivilEngineer 2 года назад
Divide the SBC with Area of the footing.
@ninjamele1925
@ninjamele1925 2 года назад
Do we need the bc factors or memorise the values?!!
@CuriousCivilEngineer
@CuriousCivilEngineer 2 года назад
Factors are available along with code. If codes are not allowed in the exam then you will need to remember them.
@ninjamele1925
@ninjamele1925 2 года назад
@@CuriousCivilEngineer but how?? there are so many values....any short trick to memorise it
@CuriousCivilEngineer
@CuriousCivilEngineer 2 года назад
Sorry no other way. You just have to practice a lot.
@ninjamele1925
@ninjamele1925 2 года назад
Thankyou for replying anyways sir....next rime i will practice....tomorrow i will just leave the question if by chance it is asked cuz i cant memorise the bc factors at one night....thanking you sir😘😘😘😘😘😘
@CuriousCivilEngineer
@CuriousCivilEngineer 2 года назад
Sure best of luck.
@parthasarathi2767
@parthasarathi2767 Год назад
Once again to tell how to compute the value of length of footing
@CuriousCivilEngineer
@CuriousCivilEngineer Год назад
For calculating bearing capacity, length of the footing is assumed as 1 meters. It is not calculated. If you're asking about design of the footing, the length comes from loading and flexural requirements.
@your_study_buddy1999
@your_study_buddy1999 Год назад
It is local shear ,,,c should be 13.33 times
@pratikshadarade09
@pratikshadarade09 3 года назад
Pratiksha darade A-27
@CuriousCivilEngineer
@CuriousCivilEngineer 3 года назад
What ?
Далее
ВОТ ЧТО МЫ КУПИЛИ НА ALIEXPRESS
09:35
Shallow Foundation - 05 Eccentric Load
29:01
Просмотров 35 тыс.
CEEN 341 - Lecture 25 - Bearing Capacity Part I
38:49
Shallow Foundation - 02 Example of Terzaghi's Equation
21:51
Soil Bearing Capacity
16:26
Просмотров 16 тыс.
The Incredible Strength of Bolted Joints
17:58
Просмотров 3 млн