When adding refrigerant to an HVAC system, does the refrigerant tank need to be upside down to add as a liquid or is it okay to leave it upright to add it as a vapor? In this video I explain the difference between adding refrigerant in liquid and vapor form, I talk about blended and single component refrigerants, and I also explain how to properly add refrigerant as a liquid. I mentioned a vaporizer in the video, here is the one I was referring to on Amazon:
Kwik Charger Tool:
amzn.to/3Ly0Dhy
Basic Yellowjacket Gauges:
amzn.to/46c0WIq
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Check out these playlists for more repair videos:
🔌 • Dryer Playlist
🧺 • Washer Playlist
🔥 • Furnace Playlist
❄️ • Air Conditioner Playlist
💧 • Water Heater Playlist
🛠️ • HVAC Tools
🔋 • Capacitor Playlist
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
🔦 Awesome Camo Flashlight:
amzn.to/33uMECU
🛒 Full Amazon Tools List:
amzn.to/2Q3QTOA
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
🅿️ If you want to support the channel:
paypal.me/WordofAdviceTV
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
📷 Interested in What Gear I use to Film my Videos?
Sony A7SIII:
amzn.to/3oqIGDC
Sigma 24-70mm Lens:
amzn.to/3t9ZYID
GoPro HERO 8:
amzn.to/2Pi0JQO
Extra Batteries:
amzn.to/3c8QBj1
Memory Card (2):
amzn.to/34rcwQ1
60" Tripod:
amzn.to/2mLXrU0
Bird-Eye View Tripod:
amzn.to/3b3RWYy
Rode VideoMicro Microphone:
amzn.to/2Ol9KDp
Rode Wireless Go Microphone:
amzn.to/3ed5Wkv
Neewer Halo Light (2):
amzn.to/2LTANUK
Viltrox LED Light Panel:
amzn.to/39ZbSu4
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
🙏 We would greatly appreciate it if you considered supporting our channel while shopping on Amazon by buying anything you need on Amazon after clicking on one of the links above. This gives us a small commission at no additional cost to you and helps us continue producing more videos! Thanks a million for your support!!
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
This video is for educational purposes. All appliance and HVAC repair work should be done by a trained professional. Word of Advice TV is not responsible for any possible damages or injuries caused by the use or misuse of the provided information.
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
📥 SPONSORS / Collabs:
Would you like to partner with Word of Advice TV? 🤝
Email: WordofAdviceTV@gmail.com ✍️
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#furnace #airconditioner #appliancerepair #heating #airconditioning #hvac #wordofadvicetv #refrigerant #HVAC

Опубликовано:

 

5 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 137   
@WordofAdviceTV
@WordofAdviceTV Месяц назад
⬇ Other Videos You May Be Interested In: How to Check Freon Pressures: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-dExFtP-nXTw.html Adding Refrigerant as Vapor: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-T2s38Dg8s4g.html Example of Throttling Refrigerant in: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-GlS8aAkUBT4.html How Often Should Freon be Checked: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-NTQP0HfPbG4.html How to Do a Pump Down on A/C: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-nY5913wSvhQ.html Top 5 A/C Problems: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-GOXgdnRB840.html How to Check A/C Compressor: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-0aAj0iqP95A.html How to Read Superheat and Subcooling: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-pUYLmxOrfo0.html
@pinballrick6031
@pinballrick6031 Месяц назад
Another great informative video. You have a special knack for stating the obvious without sounding condescending, for going into detail without causing the viewer to become glassy eyed and for getting to the point without rambling. Love the channel!
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thank you! I appreciate the positive evaluation of the video and hope to make future videos in a similar fashion!
@darkenergy5686
@darkenergy5686 Месяц назад
What an informative video. Now if I could only find an honest and conscientious air conditioning tech.
@Boboftime69696
@Boboftime69696 Месяц назад
The safest option is avoiding the big companies👍
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Glad you found it useful! They're out there so don't give up. 😉
@Ratlins9
@Ratlins9 Месяц назад
You just listened and watched an honest, conscientious air conditioning tech.
@princezay3608
@princezay3608 Месяц назад
Just become one bro !!
@princezay3608
@princezay3608 Месяц назад
I’m digging the hat bro I went to UEI a few years ago and have been doing commercial hvac since!! Wonderful trade and you definitely helped me in the past get through a few brain farts 🤣🤣 like ohming out a compressor
@francom6230
@francom6230 Месяц назад
Excellent video & concise explanation.. I like this guy and his accent is easy to listen to.
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thank you! Glad you found the video useful and easy to follow along with.
@bigd3104
@bigd3104 Месяц назад
I've always kept a Kwik Charge on my gauges for around 40 years now. Never wanted to risk damaging a compressor. Good explanation on blended refrigerants. Thanks!
@WordofAdviceTV
@WordofAdviceTV Месяц назад
You're welcome! Thanks for confirming that the Kwik Charge works good! On a side note.. You've used that adapter longer than I have been alive. 😅 It's an honor to have you frequent my channel sir! God bless you and may you have an amazing new week!
@bowlampar
@bowlampar 2 дня назад
It's noted, thank for your clear, easy to understand explanation Thump up!
@andresbarragan8595
@andresbarragan8595 Месяц назад
FROM CHICAGO IM YOUR #1 FOLOWING YOUR VIDEOS. EXELENT EXPLINATION THANK YOU SO MUCH
@WordofAdviceTV
@WordofAdviceTV Месяц назад
My #1 Following from Chicago!! I appreciate you sir! You're welcome and I bless you to have a spectacular new week!!
@llampallas66
@llampallas66 Месяц назад
Hey Jay, as your commented in the 7:54 mark with the unit off, I don’t believe you can open the suction side as you’re saying and leave it open if you’re putting liquid refrigerant because when the compressor comes on, you will also slug the compressor, you can open the high side or liquid side and yes, you can add all the liquid you want through there. But other than that, I love your videos. They’re all very educational. Thanks
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Yes, thank you for the correction! It is better to do it as you explained. Glad to hear you love the videos!
@eddiee2371
@eddiee2371 Месяц назад
The big problem now (just mho) is to find an hvac tech who knows this while he's screwing with your system. I'm sure you'll agree that standards have lowered a little bit across the board. Excellent video. Thanks for the education. Catch a cold? 🙄 oh boy. 😂
@saudiwave
@saudiwave Месяц назад
Perfect demonstration.. it’s the first time i new that information. Thanks.
@paulrozinski1488
@paulrozinski1488 Месяц назад
Great demonstration and simple, clear explanation . That beautiful background is also a great attention keeper. Great job as always, Jay. 👍👍👍
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thank you very much good sir! 🙂
@jungapo2
@jungapo2 Месяц назад
thanks for prompt reply. i also googled about this already. you are absolutely correct about your information. i am not hvac technician, but i have some background how ac and refrigeration systems work. thanks again.
@LeuCustomKnives
@LeuCustomKnives Месяц назад
Niiiice. Explains why an hvac tech I used to use added r22 both up and down.
@kenk3102
@kenk3102 Месяц назад
...thank you Jay for a very informative video.....very well explained and answered the question I've always had "why do I add freon R22 with tank upright and R410A upside down?"....and now I know.... 🙂
@WordofAdviceTV
@WordofAdviceTV Месяц назад
You're welcome! Glad I could clear that up for you. 🙂
@ttb6384
@ttb6384 Месяц назад
Thank you Jay if it s possible can you make an install video step by step thank you again for your efforts
@ali.7708
@ali.7708 Месяц назад
I offer you respect and gratitude for the information you provide on this useful channel, and I thank you very, very much with deep appreciation for you and your information.❤❤❤❤❤❤❤❤
@spelunkerd
@spelunkerd Месяц назад
If you're adding liquid refrigerant, would it be appropriate to add it to the high side so that there is. a longer path back to the compressor, allowing it to boil off before reaching the compressor?
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Yes you are right! It is better to do it that way. I stand corrected 🙂
@jimmyaber5920
@jimmyaber5920 Месяц назад
NO. Using vapor pressure of the storage tank to add to a partially charged running system requires low side charging. The high side will have more pressure than tank, and the pressure in tank may reach the safety release tab pop off range and is DANGEROUS. Adding to low side with tank inverted to get liquid for the mix refrigerants is the norm, and slow addition to allow vaporization is the method to avoid compressor damage.
@Mark-h2e5c
@Mark-h2e5c 27 дней назад
EXCELLENT VIDEO! THANKS! Catch a cold... LMAO!
@pellechi1
@pellechi1 Месяц назад
Very informative … thanks …
@WordofAdviceTV
@WordofAdviceTV Месяц назад
You're welcome! Glad you found the video useful!
@Eddy63
@Eddy63 Месяц назад
Great info explained very well ... I'm so slow , I couldn't catch a cold Aloha my friend ... Thx
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thank you sir! 🙂 Haha one of those times where being slow is actually beneficial right? 😄 Aloha Eddy, good to see you! Hope you have an amazingly great new week!
@arturolara1417
@arturolara1417 Месяц назад
Great channel great video for new people to the trade
@harrydickson4575
@harrydickson4575 Месяц назад
Awesome explanation 👍👍👍
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thank you sir! Glad you liked it! 🙂👍🙏
@netalekh6443
@netalekh6443 Месяц назад
Thank you so much!👍
@WordofAdviceTV
@WordofAdviceTV Месяц назад
You are welcome! 🙂🙂
@netalekh6443
@netalekh6443 Месяц назад
God bless you!
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thank you! God bless you and yours as well!
@sheilam4964
@sheilam4964 Месяц назад
Thx for filming this and sharing it with us.
@WordofAdviceTV
@WordofAdviceTV Месяц назад
You're welcome! Thanks for stopping by for the new video!
@Ryan5Cool
@Ryan5Cool Месяц назад
Hey Jay! I love your channel and it’s very informative as a 19 yr old hvac apprentice. I’ve watched a lot of your vids and taken notes on them. However, I haven’t seen much on the metering device and would love to hear your take specifically on those. So, Could you make a video about the metering device and all the details about it? Thanks sm and God bless.
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Hey man! (great career choice btw!) There are already many videos on RU-vid explaining how the metering devices work so I didn't feel the need to make a video on it. Or were you asking for a more simplified, basic explanation?
@Ryan5Cool
@Ryan5Cool 19 дней назад
@WordofAdviceTV just a more simplified version because I like the way you teach. Other people are great too, but you make it a lot easier!
@Brian_L_5168
@Brian_L_5168 Месяц назад
Hi Jay, when you service customers AC system, do you prefer using blended or single-component refrigerant? The Hawaiian view behind you is so soothing to see on a Sunday morning. Always learning a lot from your vids ! 💯
@WordofAdviceTV
@WordofAdviceTV Месяц назад
R22 (single component) is my favorite as it is the easiest to work with. I wish this was the only refrigerant used, that would be amazing. 😄 Glad you liked the video and the Hawaiian view! This really is a beautiful state, we're blessed to be here. Enjoy the rest of your Sunday!!
@johnvictor2451
@johnvictor2451 Месяц назад
Very well done!
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thank you sir! 🙂
@DavidHernandez-gt9bo
@DavidHernandez-gt9bo Месяц назад
Nice explanation ! 🏝️
@tommyro5723
@tommyro5723 Месяц назад
Great explanation!!!
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thank you! 🙂
@TofuInc
@TofuInc Месяц назад
410a is near-azeotropic and studies have shown there is very little, less than 1% fractionation. Most heat pumps and also a lot of refrigeration equipment will have an accumulator before the compressor suction line. With these types of systems there is really no issue with flooding the compressor as you shouldn't be adding enough liquid refrigerant to overwhelm the accumulator. I know that it probably beyond the scope of this particular video.
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thank you for a more detailed explanation on 410a!! Much appreciated! 👍
@r410a6
@r410a6 Месяц назад
So you should charge with the cylinder upwards? And if so then why refer to the cylinders arrow at the side?
@kkovler1
@kkovler1 Месяц назад
What about adding oil to the system that lubricates the compressor. How and when?Maybe another video to answer this one!
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thank you! That's a good video idea but I'll have to leave this one for someone else since I've actually never added oil to a compressor before.. I don't think it is necessary to do that. I've seen 40+ year old units that worked great without any oil added through their lifetimes.
@WallaceRoseVincent
@WallaceRoseVincent Месяц назад
Do blended refrigerants eventually separate over time? Is this how the EPA is making the world better?!?!?!
@WordofAdviceTV
@WordofAdviceTV Месяц назад
As long as there is no leaks in the system, they shouldn't be separating. I understand the sentiment about the EPA though. I wish they never banned R22, it was the best.
@hubercats
@hubercats Месяц назад
Awesome video!
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thank you! 🙂
@westonwatts6606
@westonwatts6606 Месяц назад
Nice!
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thanks! 👍
@supernova8962
@supernova8962 Месяц назад
TY so much...this is very good info
@Barryd57
@Barryd57 Месяц назад
I would never add a blended refrigerant. If u invert the jug, you risk flooding the expansion valve. I always use weight, amps, and my gauges so I recapture first, evacuate second, and then charge. Buy a small scale so u can weigh the tank as it empties into the system. Make sure you have lots of air blowing over the condensor. Also, keep the windows open (when working on a car and leave recycle OFF).
@JOEDECESARE-xe9sz
@JOEDECESARE-xe9sz Месяц назад
That was a great video Keep up the good work
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thank you, will do!
@klabkebash
@klabkebash Месяц назад
Did you drop in a "Drop In" refrigerant into an R-22 system? Or did you convert the system by reclaiming any existing refrigerant and replace the filter driers, pressure test, pull a vacuum and charge up with the replacement "Drop In" freon?
@alfredorubio2233
@alfredorubio2233 Месяц назад
thank you for the video, what kind of vaporizer do you recommend?as far as what brand of vaporizer do you recommend?thank you very much i just read in your comments, on Amazon also thank you for the tool list recommendations.
@WordofAdviceTV
@WordofAdviceTV Месяц назад
I actually don't use a vaporizer at all so I can't really recommend one from my own experience. This one seems to be the overall favorite though: amzn.to/3Wze3Qv
@SmooveBee1
@SmooveBee1 Месяц назад
R410A should be charged as a liquid only - its written on the bottle.
@bobyeager6104
@bobyeager6104 Месяц назад
Great and informative video! Of all the drop-in replacements for R22. is Bluon TDX the best or a different one? Thanks
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Glad you found the video useful! I can't really give you a good answer for that since I've only ever used the TDX. 😇 It works good in R22 systems so I don't really want to experiment with a different one. But of course if possible, using the actual R22 is best if you can get some.
@bobyeager6104
@bobyeager6104 Месяц назад
@WordofAdviceTV thank you. It's always a pleasure
@erixgar4117
@erixgar4117 Месяц назад
Hey good to see you videos again! . Do you think that it’s necessary to replace the txv when replace r22 for tdx20?
@WordofAdviceTV
@WordofAdviceTV Месяц назад
In most cases it's not necessary. As far as I know. I haven't worked enough with TDX-20 to be confident about this.
@phoneblaster
@phoneblaster Месяц назад
...that is a great video man. I was looking for something like this as I am new to all this lak. Just a question if I can ask please. Say the airconditioner is off , not running. If I am charging the system say with the tank uprigt is that then the High Side ? or is it the other way round,? . Also how do you use guages then if the gas id 'blended'' like the tdx2 ? Many Thanks.
@Tko_Seven
@Tko_Seven Месяц назад
Should I shake the tank for vapor form refill, like so in car ac refilling?
@jhunacosta6621
@jhunacosta6621 Месяц назад
Thank u very much...
@dennismcnamara6377
@dennismcnamara6377 Месяц назад
The oil in the refrigerant doesn’t enter the system when you add as a vapor, right?
@WordofAdviceTV
@WordofAdviceTV Месяц назад
That's a good question. As far as I am aware, there is no oil in the new refrigerant so this would not be a concern.
@Olds_Pwr
@Olds_Pwr Месяц назад
From what I recall, adding as a liquid, it would always charge faster.
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Yes, there is that too. It does go in faster as a liquid. Thank you for pointing that out.
@beammeupscottsp7952
@beammeupscottsp7952 Месяц назад
Hey man! Question about hvac, we just a new one installed, the new ac will kick on if it goes past the 1 degree threshold(set for 76 and it’ll kick on at 77). Our old carrier lasted 20 years but had a 2 degree threshold (set for 76 but kicked on at 78). I’m just worried at 1 degree is worse for our compressor because it’ll kick on and off more often. What do you recommend? The 2 degree split meant longer run times which might easier on the compressor in theory?
@John-zz5gt
@John-zz5gt Месяц назад
Cool beans
@jungapo2
@jungapo2 Месяц назад
how do you know if blended refrigerant will change ratio as gas versus in liquid state? was there measurement done to confirm this? anyway, good info!
@WordofAdviceTV
@WordofAdviceTV Месяц назад
I have not done any testing of my own but the manufacturers of these refrigerants have. Some bottles will actually have instructions on them that specifically say to "add this refrigerant as a LIQUID ONLY".
@borshardsd
@borshardsd Месяц назад
I respect you and your channel. The content is made to generate views and comments. But really, the epa has a test for a reason... if you don't know you shouldn't be doing it for multiple reasons
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thank you, I appreciate your feedback. That is a fair assessment. I do want my videos to generate views and comments. But this video in particular I only made because I got asked this question many times in my other videos. But I do agree that when it comes to refrigerant, it is better to call someone out.
@borshardsd
@borshardsd Месяц назад
@WordofAdviceTV you're a gentleman and a scholar. It's your show and my opinion doesn't change that I'm a fan. Ty for the reply and keep doing you regardless of our opinions sir!
@marshallwright3875
@marshallwright3875 Месяц назад
Great video Bro
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thanks bro! 👊
@alexandershilling
@alexandershilling Месяц назад
Our 410 a will be replaced with our 54B and R 32 refrigerant
@anilpunj580
@anilpunj580 Месяц назад
In like 2035, 410a isn't being phased out, production/importation will only throttle down in the coming years
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Yes, it will be a slow fade. 😉
@hubercats
@hubercats Месяц назад
Am I correct to assume that refrigerants never come in containers that have a tube that runs from the valve to the bottom of the tank?
@francom6230
@francom6230 Месяц назад
Yes, to my knowledge none have a dip tube. Btw,, He very well explained what took me years to gleen from hiring many ac techs being a building manager.
@hubercats
@hubercats Месяц назад
@@francom6230: Thank you!
@wholeNwon
@wholeNwon Месяц назад
@@francom6230 Actually some do. Simply Google for a list, if you're interested.
@sensismell42
@sensismell42 Месяц назад
Recovery tanks will have a dip tube but illegal to charge with them unless it's the same equipment being recharged after a repair.
@hubercats
@hubercats Месяц назад
@@sensismell42 : Thank you!
@rightlydivided
@rightlydivided Месяц назад
I appreciate you. Fairly new sub but you are very good
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Welcome to the channel! Glad you liked the video!
@elgordo8784
@elgordo8784 Месяц назад
Good stuff 👏
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Thank you! 👍
@acemenace7411
@acemenace7411 Месяц назад
there is no drop in replacements for refrigerants
@bigd3104
@bigd3104 Месяц назад
@@acemenace7411 R-424a can be used as a drop in replacement for R-22
@LeonSKennedy7777
@LeonSKennedy7777 Месяц назад
What would go wrong if you use a so-called “drop in replacement”, like the tdX20 he shows in this video?
@bigd3104
@bigd3104 Месяц назад
@@acemenace7411 R424a
@WordofAdviceTV
@WordofAdviceTV Месяц назад
This is a debated topic so I don't want to claim anything.. Refrigerants should not be mixed but I have added TDX-20 to a R22 system before and it worked great. (I did not mix it with R22) You just need to make sure that the refrigerant oils are compatible.
@acemenace7411
@acemenace7411 Месяц назад
@@WordofAdviceTVgotcha 👍
@waynelam550
@waynelam550 Месяц назад
Tank up for vapor , tank down for liquid
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Yes. 👍
@mikeadler434
@mikeadler434 Месяц назад
👍👍
@65cbtengr
@65cbtengr Месяц назад
Up is vapor, down is liquid
@juliopla1611
@juliopla1611 Месяц назад
👏👏👏
@poncedeleonrefrigeration9197
@poncedeleonrefrigeration9197 Месяц назад
You forgot R12 as single component refrigerant
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Yes, thank you! R12 is also a pure refrigerant.
@tryntingoering9896
@tryntingoering9896 Месяц назад
can’t buy this if ur a homeowner, against epa regulations
@user-zj3xl4nk1g
@user-zj3xl4nk1g Месяц назад
And when your only halfway up your neither up or down😂😂😂😂
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Lol yeah, something like that. 😅
@scpatl4now
@scpatl4now Месяц назад
Technicians are all about redundancy ... thus, the soda can bottle 😛
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Practice and repetition are great teachers! 😉
@steve6631
@steve6631 Месяц назад
I guess... if you have a poor memory... you'll always be OK. If you turn the bottle upside down.
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Yes, exactly! That's why some technicians are only taught to add refrigerant as a liquid. That way they will never mix things up. 😄
@bills6946
@bills6946 Месяц назад
This is precisely why you must possess a license to buy and handle refrigerants. You must have proper training to pass a licensing exam.
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Yes, when it comes to refrigerants it's best to leave it to the technicians if possible.
@diesel-legend
@diesel-legend Месяц назад
You don't need a license to buy refrigerant
@alanlacosse8850
@alanlacosse8850 Месяц назад
Just leave on its side to get the best of both worlds ....jk
@WordofAdviceTV
@WordofAdviceTV Месяц назад
Lol, now that you mention it... I totally forgot to talk about the the third, side option. 😄
Далее
How to Check AC Freon Level
16:52
Просмотров 2,1 млн
Air Conditioning isn't free... but we're close.
25:45
ЭТО мне КУПИЛИ ПОДПИСЧИКИ 📦
22:33
Timings hated him #standoff #timing #meme
00:14
Просмотров 469 тыс.
#1 Best AT HOME Test to Find Clogged Arteries
12:23
Просмотров 591 тыс.
How To Add Refrigerant To Air Conditioner
22:08
Просмотров 1,8 млн
Why Heat Pumps are now leaving people COLD
5:31
Просмотров 230 тыс.
COMMUNISM vs CAPITALISM: Who Made Better Power Tools?
24:39
How to Read SUPERHEAT and SUBCOOLING
11:43
Просмотров 599 тыс.
ЭТО мне КУПИЛИ ПОДПИСЧИКИ 📦
22:33