Siemens Micromaster 420 remote control, 2 wire, 3 wire control and potentiometer. Looking in to how to set up potentiometer with parameter changes and also wiring both types of controls. For manuals, part numbers and related videos please see below.
Direct contact on Linked in: / ingus-sudints-1b2a2517a
Website: igselectronics.co.uk/
E Bay store: www.ebay.co.uk/str/IGSElectro...
Siemens Micromaster 420: igselectronics.co.uk/products...
Siemens potentiometer: igselectronics.co.uk/products...
Siemens Micromaster 420 commissioning, local control, factory reset, parameter set up: • Siemens Micromaster 42...
Run a 3 phase motor on single phase power, basics: • Run a 3 phase motor on...
Single phase to 3 phase VFD drive home setup: • Single phase to 3 phas...
Siemens Micromaster 420 manual: cache.industry.siemens.com/dl...
There is more examples to look at for 3 wire set up, but you will need Siemens account to be able to download the file. Account is free, just needs setting up and waiting for approval. Please see the one without the account needed in link below.
Siemens MICROMASTER 420 (MM4): 2-wire 3-wire control: support.industry.siemens.com/...

Опубликовано:

 

16 окт 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 21   
@davianplaatjies-tq1dl
@davianplaatjies-tq1dl Год назад
Good basics to use the drive
@sumeshanmk8182
@sumeshanmk8182 2 года назад
Can you pls advise how to operate from key pad.before it was operating from key pad .now when i switch on the main breaker VFD automatically start
@chrisredfield8698
@chrisredfield8698 7 месяцев назад
I NEED HELP !!! 😢😢😢 I used an S7 300 PLC with a DIGITAL OUTPUT MODULE. I made a very simple program with Q0.0 as an output. I plugged a cable from Q0.0 to DIN1 (terminal 5), P700=2 to enable using terminals, P701=1 to use DIN1 as ON/OFF, P1000=1 for MOP setpoint. The program works, the Q0.0 Led lights up and i tested a 24vDC in terminal 5 STILL !!! the Drive doesn't start 😡.
@glynbrandon861
@glynbrandon861 3 года назад
I found this video and your previous video on 2-wire control very helpful. Have you ever tried to use the drive with an external JOG button? I am struggling to interpret the manual as to how to incorporate an external JOG!
@IGSElectronics
@IGSElectronics 3 года назад
Hi There. How far have you gotten with particular task you are trying to achieve. Have you assigned the jog function to any of the inputs. Manual page 46 onwards?
@glynbrandon861
@glynbrandon861 3 года назад
@@IGSElectronics Hi. I am not sure which input I can assign the jog function to. I may have to forget about trying to incorporate a JOG button and stick with the basic 2-wire configuration.
@IGSElectronics
@IGSElectronics 3 года назад
@@glynbrandon861 Ok, lets se if we can make this work. For the 2 wire control you are using input 1 to go forwards as def, input 2 is set for reverse and input 3 is reset. So if you go to par 703 and change input 3 to 10 for jog forwards or 11 to job backwards, your input 3 will be changed to jog now so you should be good to go. Let me know how it go.
@ajoykumar2604
@ajoykumar2604 3 года назад
Analog out put 4_20Ma not coming from the inventer to syncroinsn with other to decrease the speed
@IGSElectronics
@IGSElectronics 3 года назад
Hi there. It would be hard for me to pinpoint the problem without having the drive in front of me for this kind of problem. So don't think i be much help to you.
@nguyenminhkhanh3509
@nguyenminhkhanh3509 2 года назад
Der Sir.how to convert local/remote by DI & control frequency with 4-20mma . signal
@eslilopes6101
@eslilopes6101 2 года назад
Tem o esquema elétrico para passar...
@rajsinhchavda3061
@rajsinhchavda3061 3 года назад
can you please suggest me how to increase torque ?
@IGSElectronics
@IGSElectronics 3 года назад
Best way is to upgrade your drive to handle bigger torques.
@Matt1Up
@Matt1Up Год назад
7:20
@mgp9863
@mgp9863 3 года назад
Sir pls give me the diagram hor to connect those wire and how to set the parameter to run it with reverse and forward direction pls.
@IGSElectronics
@IGSElectronics 3 года назад
Hi There. I don't have wiring diagrams, please fallow the video instructions.
@SatishYadav-tl6xc
@SatishYadav-tl6xc 2 года назад
Sir can we programe it in BICO
@IGSElectronics
@IGSElectronics 2 года назад
What is BICO?
@user-hw4rp2gq4w
@user-hw4rp2gq4w 2 года назад
อินเวอร์รุ่นนี้ที่เป็นรุ่น30HPสามารถใช้กับมอเตอร์20HPได้ไหมครับ
Далее
Китайка и Шрек в Домике😂😆
00:20
Motor Control: Forward Reversing Starter
13:55
Просмотров 156 тыс.
Starting a VFD with 2-wire Start
7:08
Просмотров 39 тыс.
siemens micromaster 6SE9215 8DB40
9:25
Просмотров 6 тыс.
Китайка и Шрек в Домике😂😆
00:20