Siemens S7 1200 "Modbus RTU" Sinamics V20 VFD 

plc247 Automation
Подписаться 17 тыс.
Просмотров 35 тыс.
50% 1

PLC Siemens & Siemens Sinamics V20 Modbus RTU via RS485
Guide Link: plc247.com/siemens-s7-1200-mo...
Please share and subscribe to the channel if you find it useful !

Опубликовано:

 

3 май 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 30   
@strat_egi
@strat_egi 5 месяцев назад
I wanted to use your guide for setting up the device. but unfortunately it does not have such parameters. how to find them? Unfortunately I can’t configure it through macros. sinamics v20 fsc
@murilohenriquepereira9771
@murilohenriquepereira9771 Год назад
Goodnight! to make modbus communication with several inverters in cascade as you would indicate?
@Kazimroza4u
@Kazimroza4u 16 дней назад
Hi i am having two v20 drives connected to cpu 1214. They are running in auto mode with analog input controlling frequency. Also the inverters are connected to cpu thru modbus. Currently i had a drive issue and replaced with new drive. Now the drive is running but the rpm, current data not coming in cpu. Kindly guide
@ahmedsami2270
@ahmedsami2270 10 месяцев назад
How to cancel the negative sign, as the speed value appears on the inverter screen as negative؟
@user-ll9do3dv1i
@user-ll9do3dv1i 6 месяцев назад
i followed exactly your video and i still have no connection from my rs485 leds are off....i used both channel 10 and 11 to try modbus rtu connection but no connection do i miss something thats not on the video?
@global-tech3203
@global-tech3203 Год назад
Hello dear I got a fault 8180 on my master bloc or my id port is correct. Could you please helping me ??
@ajaydumka731
@ajaydumka731 11 месяцев назад
Thank for such a informatic video. I want a solution , after setting all parameters in sinamic v20 the drive frequency limited to 22.74 hz only . As i already provide min and max frequency. Please help
@devendrachowdary2333
@devendrachowdary2333 3 месяца назад
I have a doubt how can we assume and add those numbers to control word to control on and off or rev or fwd .i didn't see those numbers in manual Can you explain me sir
@rubentjuuu
@rubentjuuu Месяц назад
I'm using CB 1241 - 6ES7241-1CH30-1XB0 (rs485 module) but cannot get the communication to work using this tutorial. please help
@syedyasirhussain9302
@syedyasirhussain9302 9 месяцев назад
Do you have video on S7 200 & Micromaster 420 USS Protocol communication?
@adolfoleonhernandezabadia5360
Mucho gusto, una consulta referente al modulo RTU, que referencia tiene Industry Mall, muchas gracias.
@chandrajput9006
@chandrajput9006 Год назад
Not only show You will explain every point and every block of this program
@plc247automation6
@plc247automation6 Год назад
Please go to the article to read the details
@caonhumr4751
@caonhumr4751 Месяц назад
How to read faults via plc modbusRTU?
@DomenicoMadeo
@DomenicoMadeo Год назад
hello, if I change the frequency and it doesn't change on the v20 do I have a problem with communication? how can i check this?
@global-tech3203
@global-tech3203 Год назад
P1000 in you vfd must 5 for frequency control in modbus
@timschulle8238
@timschulle8238 Год назад
Can you make a video where you control the v20 with codesys? For Example with a Raspberry Pi. I am trying to control a v20 with modbus in codesys but i dont get the fault. I dont know what i did wrong. The videos with Siemens software exists often, but nowhere i found one with Codesys to control the v20. Thanks :)
@OOOMuhammadSyahrulKhoiri
@OOOMuhammadSyahrulKhoiri 2 дня назад
can you give me the program please? i cant download from your website sir
@mohammedrezk8072
@mohammedrezk8072 Год назад
why we use max for the scale o/p 16384 ?
@plc247automation6
@plc247automation6 Год назад
Sinamics V20 stipulates so
@mohammedrezk8072
@mohammedrezk8072 Год назад
@@plc247automation6 sorry i don't understand what you mean
@logicmindautomation1458
@logicmindautomation1458 7 месяцев назад
Hi, can you show your wiring on the plc from the drive?
@plc247automation6
@plc247automation6 7 месяцев назад
go to my website sir
@MehediHasan-es5et
@MehediHasan-es5et Год назад
+ Set Word 40100 = 1151 >>> Forward Run = 3199 >>> Reverse Run. How about 1151 & 3199, could you explain Please?
@henriqueteixeira1236
@henriqueteixeira1236 Год назад
Please go to the article to read the details
@global-tech3203
@global-tech3203 Год назад
1151 and 3199 there are hexadécimal code they was convert in décimal
@ronnelelpa6878
@ronnelelpa6878 Год назад
Make.a tutorial using factory Io..pick and place using analog signal
@josepintoferreira5454
@josepintoferreira5454 9 месяцев назад
vc pode enviar o projeto para o tia portal
@josepintoferreira5454
@josepintoferreira5454 11 месяцев назад
como baixar o projeto gostei muito
@Scheme_Match
@Scheme_Match 7 месяцев назад
#plc247Automation Sir I need to talk. How can i contact you
Далее
Siemens S7-1200 "Modbus RTU" TK4S Autonics Tutorial
8:13
ТЫ С ДРУГОМ В ДЕТСТВЕ😂#shorts
01:00
Sinamics V20 "Modbus RTU" via Modbus Poll
7:51
Просмотров 4,4 тыс.
S7-1200 V20 SÜRÜCÜ İLE  RS485 MODBUS HABERLEŞME
17:18
Siemens S7-200 "Modbus RTU" Siemens Sinamics V20
8:01
Просмотров 3,1 тыс.
Siemens S7-1200 Modbus RS422/485 Communication
23:37
Просмотров 130 тыс.