Simulador ECG/EKG + PIC 

GRUPO BIOMEDICO
Подписаться 788
Просмотров 8 тыс.
50% 1

Este video tutorial propone una forma simple de implementar un simulador e ECG usando una base de datos y microcontrolador PIC16F877A.
Dato vectorizado
ekg[256]= {73,74,75,75,74,73,73,73,73,72,71,69,68,67,67,67,68,68,67,65,62,61,59,57,56,55,55,54,54,54,55,55,55,55,55,55,54,53,51,50,49,49,52,61,77,101,132,169,207,238,255,254,234,198,154,109,68,37,17,5,0,1,6,13,20,28,36,45,52,57,61,64,65,66,67,68,68,69,70,71,71,71,71,71,71,71,71,72,72,72,73,73,74,75,75,76,77,78,79,80,81,82,83,84,86,88,91,93,96,98,100,102,104,107,109,112,115,118,121,123,125,126,127,127,127,127,127,126,125,124,121,119,116,113,109,105,102,98,95,92,89,87,84,81,79,77,76,75,74,73,72,70,69,68,67,67,67,68,68,68,69,69,69,69,69,69,69,70,71,72,73,73,74,74,75,75,75,75,75,75,74,74,73,73,73,73,72,72,72,71,71,71,71,71,71,71,70,70,70,69,69,69,69,69,70,70,70,69,68,68,67,67,67,67,66,66,66,65,65,65,65,65,65,65,65,64,64,63,63,64,64,65,65,65,65,65,65,65,64,64,64,64,64,64,64,64,65,65,65,66,67,68,69,71,72,73};

Опубликовано:

 

29 май 2017

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 34   
@sauldavidalonsopena3984
@sauldavidalonsopena3984 2 года назад
acabo de usar ese vector en el pic18f4550 y funciona muy bien, gracias por el video
@yennyrao3583
@yennyrao3583 2 года назад
Buena explicacion, gracias!
@alabanzassenor5569
@alabanzassenor5569 2 года назад
Buenos días amigo, una pregunta, qué valores les tienes asignado a las entradas de DC: R1(1) y C(1).
@jose6491
@jose6491 Год назад
como lograste obtener el dato vectorizado, vi otro video de tu canal que enseñaba como obtener el archivo .mat de un archivo .dat al igual que los pasos necesarios para graficarlo... pero como obtienes ese vector? es a caso el vector que obtienes luego de hacer la resta de la base con la división de la ganancia?
@leocafaro60
@leocafaro60 6 лет назад
La verdad que impresionante el tutorial. Claro, didáctico y con la información justa y necesaria, sin vueltas. Realmente te felicito y aprovecho para hacerte una consulta a ver si me podes orientar un poco. Estoy intentando armar un simulador de paciente para probar equipos de EKG de 10 canales, o sea, las 4 pinzas y los 6 electrodos precordiales. Si yo quisiera conectar los diez cables a mi simulador y ver digamos en la maquina un estudio "Normal" completo , entonces tendría que generar 10 señales diferentes al mismo tiempo ?? o sea, utilizar 10 microcontroladores para que cada uno me pase la señal correspondiente a cada una de las derivaciones ?? Si me podrías orientar te estaría eternamente agradecido. Saludos desde Argentina, y felicidades de nuevo, es genial el video.
@sthefanizambranoperez4494
@sthefanizambranoperez4494 5 лет назад
amigo en vez de implementarlo con ese pic lo puedo poner como arduino
@pablopaz5110
@pablopaz5110 4 года назад
Hola, tengo un problema y es que no me dale la señal en el osciloscopio
@nouraahmed7394
@nouraahmed7394 6 лет назад
1. is there a clear picture for the block diagram on proteus ?! 2. when i ran the proteus there is no indication that the pic works , it produces no signal ,can you help me to know where the problem is !!
@grupobiomedico5580
@grupobiomedico5580 6 лет назад
Hi Noura thats an unusual problem. could you send mi a mail to grubi.peruano@gmail.com with this subjet : Simulador ECG/EKG + PIC I will share the proteus. Also sent me the proteus that you have to chek it
@papisho23
@papisho23 6 лет назад
Buenos días amigo, una pregunta, qué valores les tienes asignado a las entradas de DC: R1(1) y C(1). Gracias.
@eliseofernandelpachas2776
@eliseofernandelpachas2776 6 лет назад
R1= 4.7k C1=100nF
@papisho23
@papisho23 6 лет назад
eliseo fernandel Pachas me refiero literal a esos puntos, no a los valores de la resistencia y el capacitor, sino los voltajes de referencia, pero gracias
@andreaa1005
@andreaa1005 3 года назад
Hola! me podrías decir ¿cómo sacaste los datos vectorizados que tienes en la cajita de información del video?
@grupobiomedico5580
@grupobiomedico5580 3 года назад
Hola andrea. Se puede obtener de una base de datos creada por tu cuenta o de una ya diseñada como physionet. Tenemos un video relacionado en el canal
@andreaa1005
@andreaa1005 3 года назад
@@grupobiomedico5580 muchas gracias checo tu canal!
@davidalejandrosanchezmoral6487
amigo tengo un problema al compilar el delay_ms(5) me marca error, alguna idea de porque?
@eliseofernandelpachas2776
@eliseofernandelpachas2776 5 лет назад
que dice el mensaje de error ?
@davidalejandrosanchezmoral6487
@@eliseofernandelpachas2776 dice error 76 ''main.c'' line 19 (4,5):expect
@eliseofernandelpachas2776
@eliseofernandelpachas2776 5 лет назад
@@davidalejandrosanchezmoral6487 verifica que tengas todos los punto y comas al final de cada linea de codigo y parentesis
@eliseofernandelpachas2776
@eliseofernandelpachas2776 5 лет назад
#include #device ADC=8; // cuantios bits hago la converion 8-10-12-16-32..... #fuses XT, NOWDT #use delay(clock=4000000) #include int i; const DOUBLE data[256]={1.00000000000000, 0.968430615605495, 0.936666992750084, 0.905012769165849, 0.873775353798092, 0.843263098616969, 0.813782419767884, 0.785634893671940, 0.759114354244523, 0.734504017728630, 0.712073661734557, 0.692076884935688, 0.674748473490100, 0.660301899640484, 0.648926977093305, 0.640787696697446, 0.636020264639742, 0.634731363859274, 0.636996657664916, 0.642859552634773, 0.652330235796343, 0.665384998849301, 0.681965859816470, 0.701980490012565, 0.725302451625084, 0.751771748529192, 0.781195690231171, 0.813350066076254, 0.847980624090299, 0.884804846074863, 0.923514007865937, 0.963775511021960, 1.00523546965049, 1.04752153363808, 1.09024592723702, 1.13300867980689, 1.17540102352897, 1.21700893112565, 1.25741676504345, 1.29621100821207, 1.33298404538720, 1.36733796323353, 1.39888833671673, 1.42726796905588, 1.45213055244746, 1.47315421701081, 1.49004493592370, 1.50253975551458, 1.51040982014915, 1.51346316308918, 1.51154723609965, 1.50455115242710, 1.49240761985323, 1.47509454282794, 1.45263627518832, 1.42510450765436, 1.39261877713832, 1.35534658788960, 1.31350313759683, 1.26735064475911, 1.21719727689232, 1.16339568242768, 1.10634113246125, 1.04646928179692, 0.984253561964122, 0.920202222057796, 0.854855036314850, 0.788779700282029, 0.722567940219496, 0.656831362997895, 0.592197076161209, 0.529303110021735, 0.468793675606999, 0.411314293973533, 0.357506833822985, 0.308004495488381, 0.263426780190873, 0.224374483991075, 0.191424756067375, 0.165126260842664, 0.145994483049138, 0.134507214069785, 0.131100256828610, 0.136163385126296, 0.150036591643030, 0.173006656867312, 0.205304068972934, 0.247100322172461, 0.298505618343126, 0.359566993770924, 0.430266889713476, 0.510522182166339, 0.600183682756797, 0.699036119110977, 0.806798599372757, 0.923125561825525, 1.04760820681023, 1.17977640437544, 1.31910106736790, 1.46499697600484, 1.61682603639298, 1.77390095200172, 1.93548928378864, 2.10081787154100, 2.26907758606342, 2.43942837913357, 2.61100459568704, 2.78292051050067, 2.95427604973839, 3.12416265612131, 3.29166925519940, 3.45588827924456, 3.61592170466556, 3.77088705856774, 3.91992335014932, 4.06219688304096, 4.19690690545412, 4.32329105610094, 4.44063056527581, 4.54825517223674, 4.64554772207807, 4.73194840763071, 4.80695862454289, 4.87014441056330, 4.92113944314658, 4.95964757280449, 4.98544487310832, 4.99838119188207, 4.99838119188207, 4.98544487310832, 4.95964757280449, 4.92113944314658, 4.87014441056330, 4.80695862454288, 4.73194840763071, 4.64554772207807, 4.54825517223674, 4.44063056527581, 4.32329105610094, 4.19690690545413, 4.06219688304095, 3.91992335014932, 3.77088705856774, 3.61592170466556, 3.45588827924456, 3.29166925519940, 3.12416265612132, 2.95427604973839, 2.78292051050067, 2.61100459568703, 2.43942837913357, 2.26907758606342, 2.10081787154100, 1.93548928378864, 1.77390095200172, 1.61682603639298, 1.46499697600484, 1.31910106736790, 1.17977640437544, 1.04760820681023, 0.923125561825525, 0.806798599372757, 0.699036119110978, 0.600183682756799, 0.510522182166338, 0.430266889713475, 0.359566993770924, 0.298505618343126, 0.247100322172461, 0.205304068972934, 0.173006656867312, 0.150036591643031, 0.136163385126296, 0.131100256828610, 0.134507214069785, 0.145994483049138, 0.165126260842664, 0.191424756067375, 0.224374483991074, 0.263426780190873, 0.308004495488381, 0.357506833822986, 0.411314293973533, 0.468793675606999, 0.529303110021735, 0.592197076161209, 0.656831362997894, 0.722567940219495, 0.788779700282029, 0.854855036314850, 0.920202222057796, 0.984253561964122, 1.04646928179692, 1.10634113246125, 1.16339568242768, 1.21719727689232, 1.26735064475911, 1.31350313759683, 1.35534658788960, 1.39261877713832, 1.42510450765436, 1.45263627518832, 1.47509454282794, 1.49240761985323, 1.50455115242710, 1.51154723609965, 1.51346316308918, 1.51040982014915, 1.50253975551458, 1.49004493592370, 1.47315421701081, 1.45213055244746, 1.42726796905588, 1.39888833671673, 1.36733796323353, 1.33298404538720, 1.29621100821207, 1.25741676504345, 1.21700893112565, 1.17540102352897, 1.13300867980689, 1.09024592723702, 1.04752153363808, 1.00523546965049, 0.963775511021960, 0.923514007865937, 0.884804846074864, 0.847980624090300, 0.813350066076254, 0.781195690231171, 0.751771748529192, 0.725302451625084, 0.701980490012565, 0.681965859816470, 0.665384998849301, 0.652330235796344, 0.642859552634773, 0.636996657664916}; void main() { while(1) { for (i=0;i
@ulises4312941
@ulises4312941 6 лет назад
Tengo una duda,, ese simulador, puede simular arritmias cardiacas?
@grupobiomedico5580
@grupobiomedico5580 6 лет назад
Hola Ulysses, si, puedes hacerlo. Tendrias que descargar la base de datos de las arritmias en physionet. Para complementar este video te recomiendo el video que subimos de physionet con matlab: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Zl68FvpEMWE.html
@ulises4312941
@ulises4312941 6 лет назад
gracias amigo
@1-febriahelena565
@1-febriahelena565 2 года назад
Could you sent me the proteus ?
@reinardk.m1841
@reinardk.m1841 5 лет назад
como convertiste el archivo.dat a txt
@eliseofernandelpachas2776
@eliseofernandelpachas2776 5 лет назад
Hola, En realidad convertir como tal no lo hice. Aqui te adjunto el enlace de otro tutorial donde puedes abrir el archivo .mat en matlab y hacer ahi la extraccion de la data. Saludo ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Zl68FvpEMWE.html
@ivasanjines4525
@ivasanjines4525 3 года назад
puedes compartirme el .hex? Por favor:(
@kaguyaxhagoro2893
@kaguyaxhagoro2893 4 года назад
no me sale la simulacion :c
@eliseofernandelpachas2776
@eliseofernandelpachas2776 4 года назад
Hola, comenta me que dificultad exacta tienes con la simulación...
@kaguyaxhagoro2893
@kaguyaxhagoro2893 4 года назад
@@eliseofernandelpachas2776 ya lo solucione jaja. tengo una duda como obtuviste tal vector??
@eliseofernandelpachas2776
@eliseofernandelpachas2776 4 года назад
@@kaguyaxhagoro2893 te recomiendo que veas este video para que tengas una idea ;) No te olvides darle dedito arriba y suscribirte :D ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Zl68FvpEMWE.html
Далее
🎸РОК-СТРИМ без ФАНЕРЫ🤘
3:12:10
Просмотров 1,4 млн
Analog sensor to monitor heart rate (ECG) with AD8232
21:00
PROCESAMIENTO ECG 2022 MATLAB | HRV - VFC | Parte 1
17:07
ECG circuito
14:58
Просмотров 9 тыс.
Don’t Buy Ryzen 9000
6:56
Просмотров 23 тыс.
How does an Electric Motor work?  (DC Motor)
10:03
Просмотров 17 млн
ECG ARDUINO  - Taquicardia y Bradicardia || JLCPCB
5:52