#single_phase_induction_motor is not a self-starting motor and is a #capacitor_start_motor.
It is also called #capacitor_start_capacitor_run_motor, because capacitors are involved here for its operation.
Generally, a rotor of a motor begins to rotate, with the torque provided by its conductors, when cut by the #rotating_magnetic_field created by its field windings.
A #3_phase_induction_motor is capable of generating a rotating magnetic field on its own, since its three individual phases are moving with 120 degree angle difference with each phase.
For a #single_phase_motor, you have to initially supply an additional phase with a different phase angle, to create the rotating magnetic field for your rotor to start turning.
This additional phase is created with the help of #start_capacitor, for the single phase #induction_motor.
Behavior of the capacitor current with its phase angle, is explained here nicely with fine animation work.
If this video is useful, please subscribe the channel.
Thank you.
#Capacitor_start_induction_motor #Capacitor_run_motor #starting_methods_of_single_phase_induction_motor #run_capacitor #start_run_capacitor #singlephase #inductionmotor #electromagnetic_induction #starting_of_induction_motor #parallel_plate_capacitor #starting_capacitor_and_running_capacitor
#capacitor_motor #motor_capacitor #capacitors_explained
More videos for you 👇
Surge Protection Device (SPD): Operation and Installation on a Single phase or 3phase DB, explained.
• Surge Protection Devic...
Safety Relay: Operation and installation explained.
• Working principle of S...
Automatic Start-Stop of generator with ATS / Automatic transfer switch / Automatic changeover switch
• How to design an ATS f...
Phase Failure Relay (PFR): Operation and Installation.
• Phase Failure Relay (P...
Emergency Stop Push button switch - Operation and Wiring Explained.
• Emergency stop push bu...
Star Delta Starter Power circuit wiring for 3Phase Induction Motor- Operation explained.
• Star Delta Starter pow...
VFD (Variable Frequency Drive) and Inverter Operation Explained.
• How Variable Frequency...
3 Phase Electricity operation: How it works and Power Calculations.
• What is 3 Phase Electr...
Motor speed (RPM) calculation: Synchronous speed & Fractional slip explained.
• Single phase Induction...

Опубликовано:

 

1 янв 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 26   
@ElectroAcademyEA
@ElectroAcademyEA Год назад
Hi everyone, Just a kind request to the viewers and professionals who can afford to sponsor or fund this channel, mainly for the benefit of the viewers all over the world.🌎🗺✈ It will also definitely be a motivation for me, to continue this channel with good explanatory educational videos for all of you. You can contribute by being a Sponsor of this channel using the following link, patreon.com/ElectroAcademy I made this request six months ago, but no one has come forward to help this channel yet.🤔💔 I know, many have become patrons of entertainment channels mainly, but look forward to seeing at least some supporters who understand the value of an educational channel like this. If you are not willing to visit a particular website for help, please contact me via email, sudarshan78@gmail.com Your kind gesture will be most welcome..!❤❤❤ Thanks and Best regards. Sudarshan, Creator of Electro Academy Channel.
@rajeshametikala1490
@rajeshametikala1490 Год назад
nice explanation
@ElectroAcademyEA
@ElectroAcademyEA Год назад
Thank you
@mdmiraj4690
@mdmiraj4690 Год назад
finally, I catch it! thank you sir
@ElectroAcademyEA
@ElectroAcademyEA Год назад
Thank you
@ZSec-ei4bv
@ZSec-ei4bv 4 месяца назад
how can some ceiling fans revert its direction? What is the logic behind the magnetic fields and capacitors that allow this?
@leejohnson197733
@leejohnson197733 Год назад
So I have a fountain and capacitor is blow, but wiring doesn't look correct as it has 3 connections from the capacitor but the drawing shows no live feed to the capacitor? Just a neutral in and 2 outputs. Is this correct? Single phase motor
@JeffMTX
@JeffMTX Год назад
A capacitor is a two terminal thing whose current through it is proportional to the rate of change of the voltage across it. That is , I= C* dv/dt. C just happens to be the “capacitance”. dv/dt is nothing more than the SLOPE of the voltage curve :)
@ElectroAcademyEA
@ElectroAcademyEA 11 месяцев назад
Thanks for your comment
@robinfrancis789
@robinfrancis789 4 месяца назад
Hi there...great video....but tell me...is this a 2 Pole or 4 Pole motor?...
@canalcaian2268
@canalcaian2268 2 месяца назад
Hello! Please! Would someone explain me how can the voltage be synchronized with current on principal coil? The coil reactance doesn't make current be late compared to the voltage? Thanks...
@DA-lq9kp
@DA-lq9kp 6 месяцев назад
What will happen if we use an inductor in place of a start capacitor in single phase induction motor? How could we get an inductor to work as a starter. I would love to see a video answering my question--I believe that this may aid my understanding of both capacitors and inductors.
@carultch
@carultch 5 месяцев назад
The reason we don't do that in practice, is that capacitance is significantly cheaper than inductance, per unit of energy storage. So usually when a design is indifferent to a capacitor vs an inductor, the capacitor is preferred. Another reason: the motor winding itself has inductance, which is especially evident at startup. You get a much more significant phase shift by pairing the motor winding with the opposite kind of reactive element, than you would get pairing it with the same kind of reactive element.
@DA-lq9kp
@DA-lq9kp 5 месяцев назад
Super--thank you@@carultch
@Le_vis254
@Le_vis254 4 месяца назад
Why voice synthesis?
@TG-ok4ty
@TG-ok4ty 3 дня назад
Cap should be on the RUN winding, not the start winding.
@heronimousbrapson863
@heronimousbrapson863 Год назад
So basically, a capacitor start capacitor run motor runs as a two phase motor all the time, both when starting and when running.
@ElectroAcademyEA
@ElectroAcademyEA Год назад
Yes.
@clenosaptyltd1980
@clenosaptyltd1980 9 месяцев назад
So it means the starting capacitor is bigger than the run capacitor right?
@ElectroAcademyEA
@ElectroAcademyEA 9 месяцев назад
Yes
@lovingit699
@lovingit699 Месяц назад
No. I my AC I have 2 x 3uf start capacitors, and the run capacitor is 50uf. But the 3uf caps can be cycled much quicker than the larger one. Lower capacitance means it fills quicker and dischargers quicker. With a start capacitor you're not dumping power like you would in a DC circuit, you're initiating a phase change, So those start caps aren't just dumping once, they're being charged and discharged thousands of times until the motor comes up to 75% of it's speed.
@andreamoses6248
@andreamoses6248 Год назад
Sorry sir why starting capacitor is dead many times?
@ElectroAcademyEA
@ElectroAcademyEA Год назад
Capacitors also have a general lifetime. However, If you connect a capacitor of acceptable brand with correct capacity, it will last longer.
@emmanuelmarope9391
@emmanuelmarope9391 Год назад
A start capacitor always worn out due to on n off it endures when motor is starting n it's subjected to high current on start up of motor LRA.
@bonifacekiprono2307
@bonifacekiprono2307 Год назад
Correct when you starting motor require high current
@Engineeringwithabhi
@Engineeringwithabhi 5 месяцев назад
🤡🥴🤪🤥😵‍💫
Далее
Викторина от ПАПЫ 🆘 | WICSUR #shorts
00:56
Capacitor and Hard Start Myths Busted
28:41
Просмотров 221 тыс.
Starting a single phase AC Motor
6:46
Просмотров 309 тыс.
How to Diagnose and Repair a Capacitor Start Motor
5:22
Get Your Motor Running: Testing A Start Capacitor
14:38
Run Capacitor Fundamentals Class
13:57
Просмотров 582 тыс.