Тёмный

Smoke Control & Fire Exit Stairwell Pressurization Systems HOW IT WORKS?  

Arki-Knows
Подписаться 2 тыс.
Просмотров 5 тыс.
50% 1

The Smoke Control and Stairwell Pressurization Systems are vital building utilities of structures. These systems are life saving machines in the event of fire and emergency.
In the event of fire or "sunog" ang smoke evacuator of smoke control system ay malaking tulong para ma exhaust out ang mga "hazardous smoke" or usok while safely the occupants are evacuating to the nearest exit point where they are safe and secure.
The Stairwell Pressurization System in "fire exit" stairwell are used for evacuation in the event of fire. It restrict the entry of smoke and toxic gases inside the fire exit stairwell through the pressurized air going into the stairwell.‪@arki-knows‬

Опубликовано:

 

16 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 31   
@VinzSusana78
@VinzSusana78 13 дней назад
Nice Sir, very clear. Thank you for this helpful knowledge from you!
@arki-knows
@arki-knows 12 дней назад
@@VinzSusana78 Thank You😀Stay safe🙏
@ReaganTe-k7t
@ReaganTe-k7t 17 дней назад
thank you so much arki. this is really very helpful for us to plan our smoke control and stairwell pressurization system. thanks
@arki-knows
@arki-knows 12 дней назад
My pleasure po😀 Stay safe🙏
@imacs23
@imacs23 7 месяцев назад
just to add information, stair pressurization pressurizes the stairwell so smoke from adjacent floor on fire or hallway wont enter the stairwell. Pressure inside is controled by a differential static pressure controller to prevent over pressurization restricting fire exit doors from opening
@arki-knows
@arki-knows 12 дней назад
Indeed👍Its also somehow similar to air curtain separating different environments providing fresh air pressure in the fire exit and preventing smoke coming inside the exit
@mildredgolpeo6098
@mildredgolpeo6098 Год назад
Gogogo Arki- knows
@arki-knows
@arki-knows Год назад
Thank You sa support😀😀😀
@mildredgolpeo6098
@mildredgolpeo6098 Год назад
Wow thanks very informative
@arki-knows
@arki-knows Год назад
Glad it was helpful!😊
@iammiam4220
@iammiam4220 Год назад
Wow very informative 😊
@arki-knows
@arki-knows Год назад
Thank You Ma’am😀😀😀
@jeffreydaryllepascual9465
@jeffreydaryllepascual9465 Год назад
Wow Archi may caption kana. Very informative. Additional knowledge. Happy new year po archi
@arki-knows
@arki-knows Год назад
Hi!Engr Jeff😀Yah i indicate para may supporting codes.Thanks again ha😀
@jamesdomingo4224
@jamesdomingo4224 Месяц назад
Atrium smoke control din po sana next na i lecture po ninyo.. thank you
@likha360
@likha360 Год назад
Thank you sa kaalaman
@arki-knows
@arki-knows Год назад
My pleasure Sir.Thanks much for the support😀
@mildredgolpeo6098
@mildredgolpeo6098 Год назад
Wow
@luffysama12
@luffysama12 9 месяцев назад
thanks sir!!
@arki-knows
@arki-knows 9 месяцев назад
Much Welcome po🥹God bless.
@pinoymaster1067
@pinoymaster1067 Год назад
Thank you sa kaalaman sir
@arki-knows
@arki-knows Год назад
My pleasure Sir.Thank You that somehow it helps.Regards and Stay safe.
@OrlyCampana
@OrlyCampana 5 месяцев назад
@richardlipa6577
@richardlipa6577 7 месяцев назад
What about the make up air and controlling the pressure inside the staircase???
@jomareyac9938
@jomareyac9938 Год назад
Sir, tanong kulang, ano po mga materials, needed pag gumawa ng stairwell pressurization.
@arki-knows
@arki-knows Год назад
Hi!Sir Jomar how are you? For the pressurization ducting.We used gauge 18 G.I. plain sheet to formed a ducting for the air pressurization.Then we provide aluminum powdercoated louvered for the air pressurization.Yung bugahan ng hangin papuntang stairwell mounted sa wall.
@jomareyac9938
@jomareyac9938 Год назад
Ano po bah, kailangan sa HP cetrifugal fan sir..
@mildredgolpeo6098
@mildredgolpeo6098 Год назад
Watch nyo na promise
@arki-knows
@arki-knows Год назад
Thank You😀❤️
@noelpimentel6493
@noelpimentel6493 Год назад
Applicable po ba ang Smoke extraction system mga walang 2nd floor? kung ang area ko ay nasa 1200sqr meters need po ba?
@arki-knows
@arki-knows Год назад
Good Day Sir Noel.For the smoke evacuator it goes working together with the air pressurization system that’s used in high rise structures.For other structure like what you referring it must be equipped with dry stand pipe system.Depending on the used of occupancy as required in the Fire Code.
Далее
Stairwell Pressurization Systems
25:50
Просмотров 9 тыс.
Батя всех бургеров на 7000 ккал!
00:55
World’s Tallest Man VS Shortest Woman!
15:07
Просмотров 17 млн
Lift shaft smoke extraction
3:17
Просмотров 8 тыс.
Atrium Smoke Control Testing
4:09
Просмотров 6 тыс.
Basics of Window Wall Systems
3:21
Просмотров 1,3 тыс.
The Hidden Engineering of Landfills
17:04
Просмотров 3,5 млн
Fire Safety
2:50
Просмотров 1,4 тыс.
NOVENCO Clear Choice Pressurization System
3:22
Просмотров 50 тыс.