Dear, Primax Galaxy 2500+ Max inverter, it's ampere range is 11 ampere but new latest solar panel produce 13 to 14 amperes. So this inverter can be burnt if constant 13 to 14 amperes are given
JAZAK ALLAH. SIR, KINDLY GUIDE FOR RUNNING 1.5 DC INVERTER AC IN NIGHT 8 TO 10 HRS. INVERTER & BATTERY. (OFF GRID). IN DAY TIME KW HYBRID SYSTEM ALREADY INSTALLED.
میرے پاس زیونک پی وی 6500ھے جنکو چھ پلیٹ 550واٹ پر پچھلے 10 ماہ سے دو بیثری پر بھترین چل رھا ھے اچھے زرلٹ کیلے میں دن کوالیکٹر ک کا بریکر بند رکھتا ھوں
Aoa Sir. I am big fan of your work. I havve a query and hope you will help me out with it. Sir we have an old locally made UPS of 1200watt at our home for the last 9-10years. it has been working very well. Due to extreme loadshedding, we installed a 585watt JA n-type solar panel alongwith a local MPPT, which was available in the market. Our battery is new and has 27plates, Phoenix 230 lead acid. We also replaced the old Cieling fans with 30watt inverter fans, and bought a TAMOOR BLDC pedestal fan. The system was working well for one 1month. However, for the last 3-4weeks, we are encountering a problem. The inverter cieling fan and the pedestal fan do not start on UPS until we have switched On the light. We have a load of 3lights and 3fans on the UPS. so when we turn on the light in the room, the fan gets switched on. If the fan is running on WAPDA,and the electricty goes and ups gets on, the fan will continue to work even without turning the light on. But if we have turned off the fan, and there isnt wapda, then we have to turn the light on for the fan to start. I called for 5-6 electricians to check if there is some wiring issue. But they said everything is perfectly fine. The UPS mechanic checked the ups and reductwd the voltage from 220 to 190, the fan started working without light. But after sometime, that measure also was futile and we had to reset the voltage to 220v. The UPS technician said the ups is working fine. The problem may lie in the fan circuits. we checked the fans with the retailer and he said the circuits are fine, however, check on the new circuits and then inform. we did it but still the problem persists. Please tell me where could the problem be since you are a very qualified person and understand these technical issues. Thanks sir. Will be waiting for your reply.
Dear Sir, mene ek 450 Watt ka solar panel lagaya he ek purane desi made UPS k 7 via PWM charger. ab me chahta hon k panel 2 krlon lakn 450 watt ka panel nahi lena chata . 585 watt wala panel lagana chahta hon. tu rehnumayi farmaaye. k me laga skta hon? awr kese lagaon. Plz detail me bataye,. Ap k hr clip me yahi comment dal ra hon but not ansered yet.... So plz respond with details.
Dear sir, can we bifurcate the coming from solar panels to apply inverter on one line and apply converter without battery on the other. Please make such video for low consumers
Assalam o alaikum aap ki videos bht informative hoti hy. Aur mujay ap se kuch malomaat chahiye. 1. Mairay ghar par single phase k 2 meter lagay hy kaya main on grid solar system lagwa sakta hon please rahnomaie farmaay aur. . 7 kw k on grid system par kaya cost aye gi.
Netrox 3kw IP65........No 1 Inverex 4kw IP21.......No 2 Itel 4kw. IP54.......No 3 itel acha inverter hae but new launch hwa hae istemal Mae pata chaligha . Specification Mae to inverex viron 4kw sae acha hae...
Boss ap ne bataya tha k ns70mppt inverter pr 585 ke do penal laga sakte hen men jab lene gaya to shop wale ne kaha k is pr 585 k nahi lagte chote penal 250 wale lagen ge. Kia ye us ki bat thik he
Asalamualikum Bhai ek aur masla aap ki Nazar ka montazar hai Bhai din ke time jab mppt use mood pe tha to mene battery ke volt check kare to wo kabhi 22 kabhi 33 kabhi to us se bhi zada show kar raha tha to kia ye koi masla hai ya Koch aur ?
Guzra kro bhai gareebi hy ab lakho k inverter nahi khareed sakty....8 solar panels pr 35000 ka inverter lagaya hy power 7 kilowatt hy. Hand made inverter hy. Boht achi performance hy. Kia zarorat hy 1 lakh 67 hazar inverter ka...😅
Bilkul sahi kaha.. Pishin Balochistan may ek banda China say electronics k original saman mangwa kar inverter banata hai.. pooray Pakistan may jis ko pata hai wo yahi mangwata hai.. 6kv 55, 60 hazar ka mil jata hai.
السلام علیکم سر میں 12 وولٹ کا پنکھا کے الیکٹرک سپلائی پے چلاتا ہوں اور جب میں سولر سے چلاتا ہوں تو 12 وولٹ والی سپلائی نکال دیتا ہوں کیا دونوں کو ایک ساتھ لگا کے چلایا جا سکتا ہے پلیز رہنمائی فرمائیے
السلام علیکم پیارے بھائی جان اپ جن سولر انورٹرز کی بارے میں بتا رہے ہیں کیا یہ سب ولٹرانک بورڈ ہیں اور پیور سائن ویو ہیں خاص کر 3۔6 کلو واٹ کا گلیکسی پرائمکس جواب کا منتظر رہوں گا شکریہ ۔🙏🏻🌹🌹
پچھلے ویڈیو میں آپ نے بتایا تھا کہ پرائیمسک 4.2 کلوواٹ dual out put کے ساتھ ہے اج statement بدل گیا کہ صرف 5 kw جو ہے وی dual out put کے ساتھ ہے۔ اور اپ نےاسکے wapda sharing کے probkem کا نہی بتایا تھا۔
Sunlife 1.5kw 2500pv price 65000 no battery attach and 5 Soler 580 watts and run electric load but battery attach good choice 1500 watts 6 Amp 220 volt load run my inverter is only Soler run best choice
آج میںPrimax 4.2 انورٹر خریدنے کئے market گیا۔ ایک تو قیمت 170000 روپت ہے ۔ اور دوسری اس کی وارنٹی کوئ نہی دے رہے ہیں۔ وہ کہتے ہیں یہ پائیدار نہی۔ please advise اور یہ دو قسم کے ہیں۔ ایک پاکستانی سرکٹ۔ اور دوسری چائنی سرکٹ والا۔ ہم confused ہو گئے اور واپس گھر آ گئے۔
پچھلے ویڈیو میں آپ نے بتایا تھا کہ پرائیمسک 4.2 کلوواٹ dual out put کے ساتھ ہے اج statement بدل گیا کہ صرف 5 kw جو ہے وی dual out put کے ساتھ ہے۔ اور اپ نےاسکے wapda sharing کے probkem کا نہی بتایا تھا۔