Тёмный
No video :(

Stairmaster Steppers Resistance Troubleshooting 

Sportsmith
Подписаться 6 тыс.
Просмотров 21 тыс.
50% 1

This Video Shows The Testing Of A Stairmaster Stepper Alternator.
Need More Support For Your Stairmaster? spsmth.com/sprt...
Looking For A New Alternator? Shop spsmth.com/lterna

Опубликовано:

 

29 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 10   
@GHOSTGXZ
@GHOSTGXZ 4 месяца назад
thanks for the 240p quality FUCCFACE
@jackccharity
@jackccharity Год назад
I have exactly the same problem with my 4600CL as the two respondents below. (GreekG91 and noscgag) It was working perfectly before I went to Europe for six months, during which time the battery went flat, giving me the "no resistance" condition and a non-working consul. I did a slow recharge of the battery and it responded well with a constant reading of 6.6 volts, steady over 24 hours. I cleaned the terminals. When I put the battery back into the machine, the consul now appears to be working normally, but I have gone from "no resistance" in the pedals, to "constant Level 1 resistance", no matter what I set the intensity level to on the consul, for any of the programs. The programs cycle through normally, but the pedal resistance does not change as the program progresses. Any suggestions on how I can fix this problem?
@ashwells6949
@ashwells6949 3 года назад
I have 4600 cl and no resistance problem. Changed the brushes on alternator, now changed the pc board and the battery and still nothing. Any ideas / help please?. Thanks. Ash
@GreekG91
@GreekG91 10 лет назад
I have an issue with too much resistance. Whether the intensity level is at 1 or 20, it stays at the same resistance level (which is probably a 1). Can you assist me in troubleshooting this issue?
@sportsmith
@sportsmith 10 лет назад
It depends what models your machine is, 7000pt, 4000pt or one of the cl models.
@gagnosc
@gagnosc 8 лет назад
+GreekG91 I had the same problem with my 4400 CL - constant resistance. The alternator was working fine, the battery was fine, and the big load resistor was fine. All the connectors were plugged in. I finally did a visual inspection of the lower PC board (the one near the alternator) and found a cold solder joint for diode D10, a 1N5349B 12V 5W Zener. After removing it and testing it I found that it was shorted completely through (acting like a wire instead of a diode). I replaced that and it works again.
@garygilbreath2218
@garygilbreath2218 8 лет назад
+noscgag I spoke too soon. Turns out the there was an additional problem. Transistor Q6 (a TIP105 Darlington transistor) was fried, the collector and emitter were shorted. I've ordered a replacement, so hopefully that will fix it.
@garygilbreath2218
@garygilbreath2218 8 лет назад
+Gary Gilbreath Well, of course that didn't fix it, but it was closer. After replacing the diode and transistor, the resistance would vary, but after 2 - 9 minutes the console would reset. I took it apart again and checked the other components. I found that the 15 W 20 ohm resistor (R16) between Q7 (TIP36C) and Q3 (RFL1N08) was open (infinite resistance). After replacing that, it works fine again.
@mathewpruett57
@mathewpruett57 3 года назад
I'm having the same exact issue..I have the I have 4600cl model
Далее
Stairmaster Steppers  Resistance Troubleshooting
2:25
StairMaster not working correctly? | Diagnosing Issues
11:34
MANTENIMIENTO A ESCALADORA STAIRMASTER
4:34
Просмотров 11 тыс.
StairMaster StepMill - Preventative Maintenance
10:00
Elon Musk: We're in deep trouble if Trump loses
4:48
Stairmaster 4000PT
2:02
Просмотров 12 тыс.
How To Set-Up & Use a Stairmaster
4:39
Просмотров 231 тыс.